| 1 | 1 | Dressing bed and preparation of sub-grade for lining | BI01010001010000000000000515BI0100001120 | 212.165 | Sqm. |
|---|
| 2 | 2 | Supply of 100 micron thick polythene sheet to be laid under bed lining as per approved drawing & design section (As per CAD Authority) | BI01010001010000000000000515BI0100001121 | 20 | Kg |
|---|
| 3 | 3 | Laying of 100 micron thick polythene sheet under bed lining as per drawing & design (N.S.item) (As per CAD Authority) Complete in all respact. | BI01010001010000000000000515BI0100001122 | 212.165 | Sqm |
|---|
| 4 | 4 | Laying of 7.62 cm. thick Ist.class brick work in 1:5 cement sand mortsr in bed over 100 micron polythene as per approved design,drawing & PWD Specification i/c supply & carriage of material Complete in all respact.\n | BI01010001010000000000000515BI0100001123 | 212.165 | Sqm |
|---|
| 5 | 5 | Laying 1st class brick work in 1:5 cement sand mortar in foundation and plinth as per approved design,drawing & PWD Specificationi/c supply & carriage of material Complete in all respact. | BI01010001010000000000000515BI0100001124 | 41.936 | Cum |
|---|
| 6 | 6 | E/Work in excavation in foundation,trenches,etc,in all kinds of soils, not exceeding 2 metres depth i/c dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, i/c disposal of all surplus soil, as directed within a lead of 30 metres. | BI01010001010000000000000515BI0100001125 | 6.65 | %Cum |
|---|
| 7 | 7 | Kassi work undressed involving an average horizontal throw upto 2 metres, and an average vertical lift up to 0.50 metrei/c breaking of clouds. | BI01010001010000000000000515BI0100001126 | 54.048 | %Cum |
|---|
| 8 | 8 | Cement concrete 1:4:8 with brick ballasts of 40mm nominal size in foundation and plinth as per approved design,drawing & PWD Specifications i/c supply & carriage of material Complete in all respact. | BI01010001010000000000000515BI0100001129 | 2.13 | Cum |
|---|
| 9 | 9 | Laying 1st class brick work in 1:3 cement sand mortar in foundation and plinth as per approved design,drawing & PWD Specification i/c supply & carriage of material Complete in all respact. | BI01010001010000000000000515BI0100001130 | 1.11 | Cum |
|---|
| 10 | 10 | Extra for brick work in arches including cost of shuttering up to 1.5 mtrs. Span Complete in all respact. | BI01010001010000000000000515BI0100001131 | 1.11 | Cum |
|---|
| 11 | 11 | 10 mm thick cement plaster in 1:4 ratio cement sand mortar as per approved design,drawing & PWD Specification i/c supply & carriage of material, water supply of arrengement & curring Complete in all respact. | BI01010001010000000000000515BI0100001132 | 85.18 | Sqm |
|---|
| 12 | 12 | Supply of RCC pannels of required size 27\"X27\" at site of work as per approved drawing & design (As per CAD Authority) | BI01010001010000000000000515BI0100001133 | 9 | Nos. |
|---|
| 13 | 13 | Fixing of RCC pannels of required size 27\"x27\" at site of work as per approved drawing & design (As per CAD Authority) | BI01010001010000000000000515BI0100001134 | 9 | Nos. |
|---|
| 14 | 14 | Supply of RCC lid of required size 21\" dia at site of work as per approved drawing & design (As peer CAD Authority) | BI01010001010000000000000515BI0100001135 | 5 | Nos. |
|---|