Special Repair To Replacement Of Ber Window Or Split Type Air Conditioner And Summer Appliances Under Ge U P And M Delhi Cantt 10, Delhi Cantt-Delhi

Military Engineer Services-MES has published Special Repair To Replacement Of Ber Window Or Split Type Air Conditioner And Summer Appliances Under Ge U P And M Delhi Cantt 10. Submission Date for this Tender is 16-01-2020. Air Conditioner Tenders in Delhi Cantt Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

22733276
Corrigendum : Special Repair To Replacement Of Ber Window Or Split Type Air Conditioner And Summer Appliances Under Ge U P And M Delhi Cantt 10
Open Tender
Indian
Delhi
Delhi Cantt
16-01-2020

Tender Details

Special Repair To Replacement Of Ber Window Or Split Type Air Conditioner And Summer Appliances Under Ge U P And M Delhi Cantt 10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Jan-2020 date amdt 09 Jan Date 16-01-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 86800.0 /-
Tender Value
INR 43.40 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR TO REPLACEMENT OF BER WINDOW/SPLIT TYPE AIR CONDITIONER AND SUMMER APPLIANCES UNDER GE (U) P&M DELHI CANTT-10.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 “Supply, installation, testing and commissioning of Inverter Technology, Hot & Cold, Split Type Wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Cap 1.5 TR , BEE 5 Star rating, fitted with rotary compressor (5 year Warranty), Refrigerant type R-410A/R-32, cooling capacity nominal (4500 Kcl/Hrs) including , PVC FRLS grade multi stranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall with cement mortar, white cement and painting works to match the existing surfaces of walls complete all as specified and directed. Model No. ASGG18LFCD of O-General , Model No. FTXF50TV16 of DAIKIN, Model No. RMB517ABXA of Hitachi and equivalent model in VOLTAS, CARRIER, FEDDERS LLYOD .\nNote:-(i) PVC drain pipes of suitable size & heavy duty Copper connection pipes including suitable insulation upto 3 Mtrs are deemed to be included in above quoted rate. \n(ii) PVC drain pipes of suitable size & heavy duty copper connection pipes including suitable insulation exceeding 3 Mtrs shall be measured and paid separately under relavent item. 15 Each
2 2 Supply, installation, testing and commissioning of Inverter Technology, Hot & Cold, Split Type Wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Cap not less than 2.0 TR minimum BEE 4 Star rating, fitted with rotary compressor (5 year Warranty), Refrigerant type R-410A/R-32, cooling capacity nominal (6000 Kcl/Hrs) including PVC FRLS grade multi stranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, clamps, nuts, bolts, washers, drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall with cement mortar, white cement and painting work to match the existing surfaces of walls complete all as specified and directed. Model No. ASGG24LFCD of O-General , Model No. FTXF71TV of DAIKIN, Model No. RMB422ABXA of Hitachi and equivalent model in VOLTAS, CARRIER, FEDDERS LLYOD .\nNote:-(i) PVC drain pipes of suitable size & heavy duty Copper connection pipes including suitable insulation upto 3 Mtrs are deemed to be included in above quoted rate. \n(ii) PVC drain pipes of suitable size & heavy duty copper connection pipes including suitable insulation exceeding 3 Mtrs shall be measured and paid separately under relevant item. 1 Each
3 3 Supply, installation, commissioning & testing of water cooler fully stainless steel body (Top lid ,front top/bottom, rear top/bottom, dip tray, side panel etc) and chiller tank(SS-304 food grade minimum 0.80mm thickness of stainless steel sheet) ,Chiller tank with PUF insulation( thickness not less than 0.6mm), including float ball valve of make prayag/ of suitable sizes as per manufacturer's design & specification with Non CFC Refrigerant (R-134a) ,energy efficient reciprocating compressor of make Emerson/Tecumseh , suitable for operation on single phase 230V, 50 Hz, AC supply, having storage capacity of 80 litres and nominal cooling capacity of 40 litres per hour , insulated top cover and fitted with hinges, gasket on all four sides, lock and key arrangement, full width single sheet moulded drain tray , Brass(CR plated) push type single faucet , motor and condenser standing base made by stainless steel of minimum thickness 1.5 mm , minimum thickness of copper tube of condenser not less than 0.50 mm, and minimum one year replacement warranty (Machine & Compressor) complete all as specified and directed. Model No. SR 40/80 of Sidwal / Model No. SRA 4080G of USHA or equivalent model of BLUE STAR and VOLTAS 25 Each
4 4 Supply, installation, commissioning & testing of water cooler fully stainless steel body (Top lid ,front top/bottom, rear top/bottom, dip tray, side panel etc) and chiller tank(SS-304 food grade minimum 0.80mm thickness of stainless steel sheet) ,Chiller tank with PUF insulation( thickness not less than 0.6mm),including float ball valve of make prayag/ Polytuff of suitable sizes as per manufacturer's design & specification with Non CFC Refrigerant(R-134a) ,energy efficient reciprocating compressor of make Emerson/Tecumseh , suitable for operation on single phase 230V, 50 Hz, AC supply, having storage capacity of 150 litres and nominal cooling capacity of 150 litres per hour , insulated top cover and fitted with hinges, gasket on all four sides, lock and key arrangement, full width single sheet moulded drain tray , Brass(CR plated) push type double faucet , motor and condenser standing base made by stainless steel of minimum thickness 1.5 mm , minimum thickness of copper tube of condenser is not less than 0.50 mm, and minimum one year replacement warranty (Machine & Compressor) complete all as specified and directed. Model No. SR 150/150 of Sidwal, Model No. SRA 150150G of USHA or equivalent model of BLUE STAR and VOLTAS\n 8 Each
5 5 Supply, installation, testing and commissioning of BEE 4 star rated frost free refrigerator double door, electric driven (single phase, 230 V, 50 Hz, AC supply) of capacity not less than 308 Ltrs with non CFC refrigerant inverter based compressor complete all as specified and directed Make -LG, Model No- GLT322RHPN/ Make - SAMSUNG, Model No-RT34M3954U7 Make- WHIRLPOOL, Model No- 355ELT4S or equivalent model of VIDEOCON, KELVINATOR and VOLTAS 12 Each
6 6 Supply, Installation, testing and commissioning of Deep Freezer having hard top double door with locking arrangement, electric driven (single phase, 230 V,50 Hz AC supply), not less than 320 Ltrs with temperature range (-18°C) working with Non CFC refrigerant, energy efficient compressor, puff insulation, heavy duty castor wheels and complete all as specified and directed, Make-Voltas, Model No. 5210395 or equivalent model Blue Star,SHRIRAM(USHA) 4 Each
7 7 Supply, installation testing and commissioning desert cooler electric driven (single phase), 230V, 50 Hz, AC fitted with three speed motor, copper wounded, submersible pump of suitable capacity, rotary switch, swing operation, three core flexible copper conductor wire, honey comb pads on three sides, water level indicator, thermal overload protection for pump and motor and fixing including Plywood work and certain modification work to the existing ground support for installation of desert cooler as per site requirement complete all as specified and directed. Make Model or equivalent Models in Symphony/Kenstar/Khaitan \nNote :- Plywood as required for covering up void portion after taking out window AC/ desert cooler and angle iron/flat iron as required at site for modification work to the existing ground support will be measured and paid separately under relevant item . 31 Each
8 8 S&F in replacement single pole and neutral steel metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of 32 Amps.complete all as specified and directed. 16 Each
9 9 Material & labour for AC Sub main wiring ISI marked with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (Conforming to IS-694) multi stranded, unsheathed 1100 volts grade in PVC casing Capping (medium grade) of adequate size on surface of wall/ceiling with all fittings & casing capping accessories including one run 6 Sqmm single core unsheathed multi stranded, copper cable FRLS (Conforming to IS-694) as earth continuity wire complete all as specified and directed.\nNote :-1. Two runs of cable with one run of earth wire and PVC casing capping shall be measured as one unit length.\n2. Extra length of cable required for connection of DB shall be deemed to be included in the quoted rate and shall not be measured separately.\n3. Earth wire shall run inside the casing capping. \n4. Suitable colour code of wire must be ensured for phase/neutral/earth. 60 RM
10 10 Supply & fixing in replacement heavy duty copper pipe 1/2" dia/bore complete including suitable insulation, brazing, welding, nut bolts and screws of reqd size complete all as specified and directed. 25 RM
11 11 Supply & fixing in replacement heavy duty copper pipe 1/4" dia/bore complete including suitable insulation, brazing, welding, nut bolts and screws of reqd size complete all as specified and directed. 20 RM
12 12 Supply & fixing in replacement heavy duty copper pipe 5/8" dia/bore complete including suitable insulation, brazing, welding, nut bolts and screws of reqd size complete all as specified and directed. 5 RM
13 13 Supply, Installation, testing and commissioning of 80 Ltrs/Hr RO Water Purifier system comprising of carbon block, filter with 5 micron rating, RO pump PSI 250GPD, 220 Volts, 50 Hz adaptor with 48 Volts, four Nos of membrane, low pressure switch, SV switch, sediment/pre filter of suitable capacity complete all as specified & directed . Model No of Kent or equivalent moldel of Aquaguard/ Bluestar/ Voltas 5 Each
14 14 Supply & fixing exterior grade ,Veneered decorative plywood 4mm thick grade-I (with BWR resin) with decorative face veneers on both faces fixed with screws to timber frame work including teak wood beading of suitable size as required at site to cover up void portion left after installation/Removing of Window type Air Conditioner/Desert cooler complete all as specified and directed., 20 Sqm
15 15 M&L for Framed brackets of angles or tees with web and flanges cut to shape ,drilled and countersunk for screw , including bending and welding angles, as necessary, gusset plates, riveting etc, n.exc 10 kg each brackets conforming to Fe-290, Gde-E-165, including necessary grouting in wall/ground support etc.complete all as specified and directed. 20 Kgs
16 16 Supply & fixing powder coated brackets for outdoor unit complete with fixing nuts bolts, washers, driling holes/grouting on wall complete all as specified and directed by Engineer-in Charge 10 Set
17 17 Supply & fixing in repair /replacement PVC connection pipe heavy duty 15 mm dia bore with PTMT nuts of length 450 mm complete all as specified & as directed. 30 Each
18 18 Supply & fixing in repair /replacement PVC flexible waste water drain pipe of size not execding 50 mm dia including fitting (bend/nipple) length not less than 1.0 RM complete all as specified and directed. 20 Each
19 19 Taking down sub main wiring complete, including sockets etc, and removing taken down materials from site and making good disturbed surfaces of wall, ceiling, floors etc complete all as specified and directed. 25 RM
20 20 Taking out after disconnection the old /BER Window/Spilt AC of any capacity and transporting/depositing to AGE AC(OTBH) store complete all as specified and directed . 10 Each
21 21 Supply and fixing in repair/replacement (Drain Pipe) Low density Polyethylene (LDPE) pipes of Pressure rating 6 kgf/sq. com of size 20 mm dia including all fittings 20 RM