Agmc Of Sub-Station Panels , Internal Work Including Operation Of Gd Set , Lifts And Water Pumps Agmc Of Sub-Station , Internal Electrification Work And Associated System Including Operation Of Dg Set , Water Pumps And Lifts Installed At Csir Hq , Csircx , Csir Naraina And Csir Scientist Apartments New Delhi , Schedule A - Csir Hq And Science Centre , Sub-Head- I :- Operation , Preventive And Routine Maintenance Of Electrical Systems . , Operation And Maintenance Of Entire Electrical Installation Including Distribution Boards , Lt Panels , Operation Of Various Dg Sets , Waterpumps And Lifts At Csir Hq And Csir Vigyan Kendra , New Delhi . The Scope Of Work Including The Deployment Of Manpower Is As Per Annexure -I , Schedule B - Csir Complex And Guest House , Sub-Head- I :- Operation , Preventive And Routine Maintenance Of Electrical Systems . , Operation And Maintenance ( Routine/ Preventive/Breakdown ) Of Entire Electrical Installation Including Distribution Boards , Lt Panels , Operation Of Various Dg Sets , Substation , Waterpumps , Lifts And Comprehensive Maintenance Of 300 Kvar Capacitor Bank At Csir Complex , New Delhi . The Scope Of Work Including The Deployment Of Manpower Is As Per Annexure -I , Schedule C :- Naraina , Sub-Head- I :- Operation , Preventive And Routine Maintenance Of Electrical Systems . , Operation And Maintenance ( Routine/ Preventive/Breakdown ) Of Entire Electrical Installation Including Distribution Boards , Lt Panels , Operation Of Various Dg Sets , Substation , Waterpumps And Comprehensive Maintenance Of 200 Kvar Capacitor Bank At Csir Naraina Complex , New Delhi . The Scope Of Work Including The Deployment Of Manpower Is As Per Annexure -I , Schedule D :- Mbsa And Ipu At Niscair , Sub-Head- I :- Operation , Preventive And Routine Maintenance Of Electrical Systems . , Operation And Maintenance ( Routine/ Preventive/Breakdown ) Of Entire Electrical Installation Including Distribution Boards , Lt Panels , Operation Of Various Dg Sets , Waterpumps , Lifts And Comprehensive Maintenance Of 100 Kvar Capacitor Bank At Csir Mbsa , New Delhi . The Scope Of Work Including The Deployment Of Manpower Is As Per Annexure -I , Sub-Head - Ii :- Replacement Of Electrical Components & Accessories . , Replacement Of Defective Of Following Rating And Breaking Capacity And Pole Mccb Including Supply With Thermomagnetic Relaase And Terminal Spreaders In Exiting Cubicle Panel Board Drilling Connections Etc As Required . , 100 A , 16 Ka Tpmccb , 125 A , 16Ka Tpmccb , 200 A , 25Ka Tpmccb , 125 A , 36 Ka Fpmccb , 200 A , 36 Ka 4 Pole Mccb , 630 A , 50 Ka 4 Pole Mccb , Replacement Of Defective 5 Amps To 32 Amps Rating , 240/415 Volts , C Curve , Miniature Circuit Breaker Including Supply Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . , Single Pole , Single Pole And Neutral , Triple Pole , Triple Pole And Neutral , Replacement Of Defective 63 Amps Rating , 240/415 Volt C Series , Miniature Circuit Breaker Including Supplysuitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections , Testing & Commissioning Etc . As Required . , Single Pole And Neutral , Triple Pole And Neutral , Replacement Of Defective Fan Regulator On Existing Switch Box Cover Including Supply And Connections Etc Complete In All Respect . Switch Type Fan Regulator Of Anchor / Rider Make 100 Watt 230 Volts , Replacement Of Defective Dp Sheet Steel Enclosure On Surface/ Recess Along With 25/32Amps 240 Volts C Curve Dp Mcb Including Supply Complete With Connections , Testing And Commissioning Etc . As Required . , Replacement Of Defective Heavy Duty Exhaust Fan Of 300 Mm Sweep , Single Phase , 900/1400 Rpm Complete With All Accessories Including Their Connections Etc Complete In All Respect . , Replacement Of Defective Fluorescent Tube 20 Watt 230 V Including Supply In Existing Light Fitting Etc Complete In All Respect . , Replacement Of Defective Electronic Ballast 20 Watt , 230 V Including Supply In Existing Fitting Etc Complete In All Respect . , Replacement Of Defective Fluorescent Tube 36 Watt 230 V Including Supply In Existing Light Fitting Etc Complete In All Respect . , Replacement Of Defective Electronic Ballast 36Watt , 230 V Including Supply On Existing Fitting Etc Complete In All Respect . , Replacement Of Defective Starter Including Supplyin The Existing Fluorescent Tube 18/36 Watt 230 V Fitting Etc Complete In All Respect . , Replacement Of Defective Pl - L 36 W , 230 V Pl Tubeincluding Supply In Existing Fitting Etc Complete In All Respect . , Replacement Of Defective Of Following Rating Doble Pole ( Single Pole And Nutral ) , 240 Volt , Residual Current Circuit Breaker ( Rccb ) Having A Sensitivity Current Upto 300 Ma Including Supply In The Exiting Mcb Db Complete With Connection , Testing And Commissioning Etc As Req . , 40 Amps , 63 Amps , Replacement Of Defective Cfl 11 W , 230 V On Existing Fitting Etc Complete In All Respect . , Replacement Of Defective Capacitor 2 . 5 Mfd , 230 V A . C . Including Supply In The Existing Fitting / Fans Etc Complete In All Respect . , Replacement Of Defective Plug Top Including Supply , Connections Etc . As Required . , 3 Pin Top 6 Amp , 3 Pin Top 16 Amp , Replacement Of Defective Flexible 3 Core 2 . 5 Sq . Mm . Copper Pvc Insulated Unarmoured Round Cable 1 . 1 Kv Grade Including Supply , Connection Etc As Required . , Replacement Of Defective Gang Box On Surface Or In Recess With 5 Pin 5/6 Amps Socket Outlet And 5/6 Amps Piano Type Switch , Including Supply , Connections Etc . Complete As Required . , Replacement Of Defective Gang Box On Surface Or In Recess With 5 Pin 15/16 Amp Socket Outlet And 15/16 Amps . Piano Type Switch , Including Supply , Connections Etc . Complete As Required . , Replacement Of Defective Gang Box On Surface Or In Recess With 2 Numbers 5 Pin 5/6 Amp Socket Outlet And 2 Numbers 5/6 Amps Piano Type Switch , Including Supply , Connections Etc . Complete As Required . , Replacement Of Defective Pl - L 18 W , 230 V 2 Pin Tube Including Supply In The Existing Fitting Etc Complete In All Respect . , Replacement Of Defective Electronic Ballast For Pl - L 18 W , 230 V Pl Tubeincluding Supply Fitting Etc Complete In All Respect . , Replacement Of Defective Following Led Fittings On Surfac Complete With All Accessories Like Driver Including Supply , Connection Etc As Required . , Led Down Light 8 Watt , Philips , Havells , Led Fittings 18 Watt , 4 Fit Double Connection , Replacement Of Defective 9 Watt Led Bulbs , 230V , Ac , Including Supply Etc As Req . , Replacement Of Defective Piano Type Socket Fan Regulator Etc Complete As Required . , S / I / T/ C Of 40 Watt , Or Above 250V , Pure Polyster Uv Resistant Power Coated Die Cast Aluminium Housing With Pmma Opal Diffuser For Uniform Illumination . Post Top Led Fittings With Ip65 Protection Including Driver And Accesories Etc Complete As Req . ( Make - Philips Or Wipro-Lp02 ) , S / I / T/ C Of 7 . 5 Hp Open Well Submerisble Pump , 440 V Ac , Copper Winding , Discharge Flow 500Lpm , Horizontal Type , Single Stage , Outlet Size 75Mm , Kiriloskar Make , Etc Complete As Reqd . , S / I / T/ C Of 1 Hp , 250V , Make - Ksb Mlubi Sewage , Submersible Pump With Autometic Float Switch , Lfp2115f , Outgoing & Incomming Pipe Connection Etc As Reqd . , Supplying And Fixing Of Following Ways , Horizontal Type Three Pole And Neutral , Sheet Steel , Mcb Distribution Board , 415V , On Surface / Recess , Complete With Tinned Copper Bus Bar , Neutral Bus Bar Earth Bar , Din Bar , Interconnections , Power Painted Including Earthing Etc A