Overhauling Servicing Replacement Of Hp Lp Valves Of Turbine Side Of Unit 6 2X500 Mw D Tps Anpara, Anpara Thermal Power Station-Uttar Pradesh

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published Overhauling Servicing Replacement Of Hp Lp Valves Of Turbine Side Of Unit 6 2X500 Mw D Tps Anpara. Submission Date for this Tender is 16-12-2019. Valve Tenders in Anpara Thermal Power Station Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

22716451
Overhauling Servicing Replacement Of Hp Lp Valves Of Turbine Side Of Unit 6 2X500 Mw D Tps Anpara
Open Tender
Indian
Uttar Pradesh
Anpara Thermal Power Station
16-12-2019

Tender Details

Overhauling Servicing Replacement Of Hp Lp Valves Of Turbine Side Of Unit 6 2X500 Mw D Tps Anpara

Key Value

Document Fees
INR 1180 /-
EMD
INR 26000.0 /-
Tender Value
INR 13 Lakhs /-

BOQ Items

Name of Work: < Overhauling/Servicing/Replacement of HP/ LP Valves of Turbine side of Unit No. 6, 2X500 MW, ‘D’ TPS, Anpara >
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Servicing of Isolating Valve, Control Valve & NRVs of Condensate Line, TDBFP Extraction, Extraction-5 and Booster Pump Suction Line; Size: 400 mm, Class: 150 to 300. item1 22 No.
2 2 Servicing of Isolating Valve, Control Valve & NRVs installed on BFP discharge, Feed Discharge Line, HPH Inlet/ Outlet, HPH 50% Bypass and other similar valve; Size: 350 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC. item2 11 No.
3 3 Servicing of HPH 100% Bypass valve and Feed water inlet to Economiser of Size: 500 mm, Class:2850 item3 2 No.
4 4 Servicing of BFP Recirculation Line Control Valve; Size: 200 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC. item4 3 No.
5 5 Servicing of BFP Recirculation Line Isolating Valve and SCNRV; Size: 200 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC. item5 6 No.
6 6 Servicing of Isolating Valve and Control Valve from Main Steam Line to Auxiliary Steam Header; Size: 200 mm, Class: 2750 SPL Design press.: 188.5 Kg/cm2, temp.: 545 oC. item6 1 No.
7 7 Servicing of Main Steam Control Valve to Aux Steam Header; Size: 350 mm, Class: 3500 Design press.: 188.5 Kg/cm2, temp.: 545 oC. item7 1 No.
8 8 Servicing of Isolating, Control Valve and SCNRVs installed on Aux Steam, Extraction Steam to Deaerator, Extraction Steam to TDBFPs, Extraction Steam to LPH-3; Size: 500 mm, Class: 150 to 300 Design press. <40 Kg/cm2, temp.<330 oC. item8 9 No.
9 9 Servicing of Extraction Steam Valve or NRV to LPH-2; Size: 800 mm, Class: 150, Design Press.: Vacuum, temp.:135 oC. item9 1 No.
10 10 Servicing of motor operated control valve, motor operated gate/ globe valves, manually operated gate/ globe valves, check valves; Size:300~350 mm, Class: 150 to 300, Design Pr.< 40 Kg/cm2 and temp.:350 oC. item10 16 No.
11 11 Servicing of HP Bypass spray water control valves, spray isolation valves, NRVs on Turbine side. Size:100-150 mm, Class: 2500, Pr. : 320 Kg/cm2 and temp.:185 oC. item11 13 No.
12 12 Servicing of HP Bypass Warm up line regulating valves, Isolation valves, NRVs and other similar valve; Size:50 to 80 mm, Class: 3000 special, Pr.: 188.2 Kg/cm2 and temp.:545 oC. item12 8 No.
13 13 Servicing of turbine MAL drain valves (MAL-11, MAL-12, MAL-22, MAL-26, MAL-27, MAL-31, MAL-32, MAL-47, MAL-51, MAL-52, MAL-54, MAL-55, MAL-65, MAL-81, MSV-105, MSV-106, HRHV-105, HRHV-106) and othe similar valves. item13 18 No.
14 14 Servicing of Isolating valve and control valve of Feed Control Station Size:250 mm, Class: 2500, Pr. : 320 Kg/cm2 and temp.:260 oC. item14 3 No.
15 15 Servicing of Isolating valve, control valve and NRVs of Size:250 mm, Class: 150-600. item15 15 No.
16 16 Servicing of Isolating valve, control valve and NRVs of Size:150 mm to 200 mm, Class: 1500, Pr. : 54 Kg/cm2 and temp.:360 oC. item16 20 No.
17 17 Servicing of Isolating valve, control valve and NRVs of Size:150 mm to 200 mm, Class: 150-600. item17 1000 mm
18 18 Servicing of Isolating valve, control valve and NRVs of Size:40 mm to 50 mm, Class: 1500 to 2500. item18 15 No.
19 19 Servicing of HP Evacuation valve. item19 1 No.
20 20 Servicing of Hydraulic Operated Vacuum Breaker Valve. item20 1 No.
21 21 Servicing of Isolating valve, control valve and NRVs of Size: 15 mm to 100 mm, Class: 1500. item21 800 mm
22 22 Replacement of LP valves of different Floors by cutting of damaged valve & arc welding of new valve. Size: 15~50 mm. item22 500 mm
23 23 Replacement of HP line drain valves of different Floors by cutting of damaged valve & welding of new valve. Size: 15~50 mm. item23 5 No.
24 24 Replacement of HP line valves of different Floors by cutting of damaged valve & welding of new valve. Size: 40~65 mm. item24 4 No.
25 25 Replacement of HP valves of Feed Water/ Main Steam Line/ CRH Line/ HRH Line etc; size Nb-65~150 mm. item25 1 Jobs
26 26 Replacement of LP Valves of size Nb-300 mm, Pressure rating < 40 Kg/cm2. item26 1 Jobs
27 27 Replacement of LP Valves of Nb-250 mm, Pressure Rating < 40 Kg/cm2. item27 1 Jobs
28 28 Replacement of LP Valves of Nb-350 mm, Pressure Rating < 40 Kg/cm2. item28 1 Jobs
29 29 High Pressure Argon/ Arc Welding by IBR Welder. item29 4 Jobs
30 30 Replacement of butt welded gate / globe valves of LP lines. Size: 80-100 mm. item30 2 No.
31 31 Repair/ Replacement of LP/HP piping by cutting & welding on per mm ID basis. item31 500 mm
32 32 Replacement of flange type gate / globe valves of LP lines; Size: 75 -100 mm. item32 2 No.
33 33 Servicing of Safety valve of HP Heater, Deaerator & FST, HT&LT Header of Aux. PRDS & TDBFP Inlet Steam line. item33 10 No.
34 34 Revisioning / Servicing of Butterfly valves; Size: 65 mm to 250 mm. item34 750 mm
35 35 Revisioning / Servicing of Butterfly valves; Size: 300 mm to 800 mm. item35 8000 mm
36 36 Revisioning / Servicing of TDBFP Exhaust Butterfly valves; Size: 1600 mm. item36 2 No.
37 37 Revisioning / Servicing of Condenser inlet/ outlet Butterfly valves; Size:2200 mm. item37 4 No.
38 38 Revisioning / Servicing of NRV installed on ACW line & ECW line; Size: 300 mm to 500 mm. item38 4000 mm
39 39 Servicing of gear boxes of butterfly valves installed on ACW & ECW System. Valve Size: 65~250 mm. item39 5 No.
40 40 Servicing of gear boxes of butterfly valves installed on ACW & ECW System. Valve Size: 300 to 600 mm. item40 5 No.
41 41 Servicing of gear boxes of butterfly valves installed on ACW System. Valve Size: 800 mm. item41 4 No.
42 42 Servicing of gear boxes of butterfly valves Size: 1600 mm. item42 2 No.
43 43 Servicing of gear boxes of butterfly valves Size: 2200mm. item43 4 No.
44 44 Inspection/ Minor repairing of ball catch strainer of condenser tube cleaning system installed inside CW return line of size: 2200 mm. item58 2 No.
Disclaimer :