Department of Agricultural Research and Education has published Electrical Work Renovation Of Electrical Wiring And Electricals Appliances/Fixtures In The Existing Building Utilized As Trainees Hostel At Mes Of Ciba At Muttukadu. Submission Date for this Tender is 10-12-2019. Electrical Maintenance Tenders in MES of CIBA at Muttukadu Tamil Nadu. Bidders can get complete Tender details and download the document.
Name of Work:Renovation of Electrical wiring and Electricals appliances/fixtures in the existing building utilized as trainees hostel at MES of CIBA at Muttukadu | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Electrical Work: | BI01010001010000000000000515BI0100001112 | ||
2 | 1.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor Single core cable etc. as required. Group A | BI01010001010000000000000515BI0100001113 | 95 | Points |
3 | 1.02 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | BI01010001010000000000000515BI0100001114 | 300 | Mtrs |
4 | 1.03 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire | BI01010001010000000000000515BI0100001115 | 80 | Mtrs |
5 | 1.04 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | BI01010001010000000000000515BI0100001116 | 350 | Mtrs |
6 | 1.05 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | BI01010001010000000000000515BI0100001118 | 24 | Each |
7 | 1.06 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and Fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 24 | Each | |
8 | 1.07 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with Connections, testing and commissioning etc. as required. | 12 | Each | |
9 | 1.08 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board,415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)\n 4 way (4 + 12), Double door | 2 | Each | |
10 | 1.09 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door | 6 | Each | |
11 | 1.1 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and Commissioning etc. as required.(63A) | 2 | Each | |
12 | 1.11 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, Testing and commissioning etc. as required.(40 A) | 6 | Each | |
13 | 1.12 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | 60 | Each | |
14 | 1.13 | Supply, installing, testing and commissioning of following size ceiling fan complete with all accessories including wiring the down rod of standard length (upto 30 cm) with PVC insulated PVC Round Sheathed copper conductor flexible cable etc., as required. (but without regulator)\n(1200 mm sweep (BEE 5 star rated) | 18 | Each | |
15 | 1.14 | Supply, installation, testing and commissioning of 300 mm sweep exhaust fan made upof metal body including connections with 1.5 sq.mm FR PVC insulated copper conductor wiring etc, as required | 6 | Each | |
16 | 1.15 | Supplying and fixing of following indoor IP20 ingress protected RoHS & EMC complaint LED light fixtures suitable for 230 VAC, 1 Phase 50 Hz input power supply, including making connections etc. complete as required 24.1 (1200 mm Industrial Batten, 2000 Lumen),Industrial Batten type LED Fitting with CRCA housing, high efficiency diffuser cover, surface mounting, 1200 mm long, directly mounted on ceiling/wall with suitable mounting accessories etc., having the following specification.System Lumen output : 2000,Minimum system lumen efficiency : 100 lm/W, THD: <10%, PF:>0.90, CRI : 80 ,Color Temperature : 5700K/6500 K,L70B50 > 50,000 Hrs. | 24 | Each | |
17 | 1.16 | Supplying , Installation, testing and commissioning of 9 watts LED fitting with all accessories directly on ceiling including wiring with 1.5 sq. mm PVC insulated FRLS copper conductor single core cable, ETC., as required, | 12 | Each | |
18 | 1.17 | Supplying and testing of following size one number XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade conforming to IS 7098 (Part-1) 1988 as required \n4 x 25 Sq.mm | 50 | Mtrs | |
19 | 1.18 | Supplying and making straight through joint with cast resin compound including \nferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.\n(4 X 25 sq. mm) | 1 | Set | |
20 | 1.19 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 25 sq. mm (28mm) | 3 | Set | |
21 | 1.2 | Supplying and laying of following size DWCHDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia \n(OD- 63 mm & ID-51 mm nominal) | 40 | Mtrs | |
22 | 1.21 | Providing and fixing PVC drain pipe 19 mm dia for AC drain water etc. as required. | 50 | Mtrs | |
23 | 1.22 | Supply and fixing of 15 liter storage water heater i/c inlet and outlet connection complete as required. | 6 | Each | |
24 | 1.23 | GST for all the above items in percentage has be given in the cell-M36 and GST amount will be calculated automatically in Cell-BA36.\n\n | 1 | % |