Providing And Installation Of Decorative Poles And Led Fittings Along Footpath At Hansraj Sethi Marg And Epdp Mall Road On Pwd Road Under Pwd South East , New Delhi , Supplying , Installation , Testing & Commissioning Of Decorative Led Post Top Lantern Of 50-60Watt With Ip66 Protection , Cct-3000K , Pf> . 95 , Thd<10% , Efficacy>100Lm/W , Cri>70 And Having Aluminium Body ( Width-450-500Mm And Height-1200-1300Mm ) With Aluminium Heat Sinks Those Provided At Upper Portion Of Fitting . A Uv Protected Pc Single Piece Prismatic Diffuser To Be Provided For Glare Free Lighting . Fixture Shall Be Powder Coated/Pu Painted With Suitable Spigot To Fit On 3 Mtrs . Height Pole I/C All Accessories / Attachments , Connection & Interconnection Etc . As Required . Fitting Should Have Bis Certificate . ( Note-As Per Attached Drawing & Approval Of Engineer-In-Charge ) . , Supplying & Erection Of 3 Mtrs . Decorative Pole Made Out Of Galvanized Mild Steel Tubes Having 140Mm Dia . Of Length 1000Mm With 4 . 8Mm Thick At Bottom And 75Mm Dia . Of Length 2000Mm With 3 . 2Mm Thick At Top With Cast Aluminium Emblishments . The Poles Should Be Primer Coated And Painted With Polyurethane Paint ( Colour Of Pole May Be Decided By E-In-C ) . The Pole Should Have Sleeve Type Cover Arrangement For Service Window At The Height Of 500Mm From Bottom And Comprising Of Four Way 32 Amp Connector Terminal I/C Clamp Support For Cable And Din Channel And One No . Mcb . Poles Should Have Mild Steel Base Plate Of Size 300Mmx300mm Of 10Mm Thickness Having Four Numbers Mounting Holes Of Dia . 20Mm Etc . Complete As Required . ( Note-As Per Drawing Attached & Approval Of Engineer-In-Charge ) . , Supplying And Drawing Following Size Of Pvc Insulated Copper Conductor Multicore Cable In The Existing Poles And Bracket From Cable Termination Connector To The Fitting I/C Providing Suitable Copper Lugs Connections Etc . As Reqd . , 3 Core 1 . 5 Sq . Mm , Providing And Laying In Position ( 1:2:4 ) Reinforced Cement Concrete Foundation Of Size 400 Mm ( L ) X 400Mm Wide And 700Mm Deep I/C Excavation Of Earth , Providing Cutting , Bending And Placing In Position , Reinforcement Ring Of Cold Twisted Bars Of 12Mm Dia . 800 Mm Long =8Nos . And Reinforcement Ring Of Cold Twisted Bar Of 8Mm Dia -1600 Mm ( Approx ) 6 Nos . ( With Equal Spacing ) As Required With Positioning Of Foundation Bolts And Providing 40 Mm Dia . ( O . D . ) Dwc , Hdpe Pipe Of 0 . 3 Mtrs . Length For Cable Entry & Exit As Reqd . , Supplying And Fixing 4 Nos . 16Mm Dia . X 500Mm Long Gi Foundation Bolt ( En8 Grade ) With Nuts , Washer Including 1 No . Template Of 3 Mm Thick Size 300Mmx300mm With 4 Nos . 20Mm Dia . Holes To Match With Pcd Of Pole Base Plate As Reqd . , Supplying , Laying And Fixing Of One Number Xlpe Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Armored Power Cable Of 1 . 1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required . , 4X16 Sq . Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1 . 1 Kv Grade As Required . , 4 X 16 Sq . Mm ( 28Mm ) , Providing And Fixing 6 Swg Dia . G . I . Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable Etc As Required . , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket , Bend , Couplers Etc . Conforming To Is 14930 , Part Ii Complete With Fitting And Cutting , Jointing Etc . Direct In Ground ( 45 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc . , Complete As Required . , 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) , Providing , Boring & Laying Hdpe Pipes ( Isi Marked ) Of 120 Mm O . D . Confirming To Is:4984-1995 As Amended Upto Date With Pressure Rating Of 4 Kg/Sq . C . M By Trench Less Technology With No Dig Method By Making Bore Hole In Horizontal Direction Across The Road As Per Direction Of Engineer-In-Charge With Mouling Equipment I/C Jointing Cleaning , Rodding Of Pipe . Providing , Suitable Covers On Mouth Of Pipes , Excavation Of Pits Of Required Size At Appropriate Depth . , Excavation Of The Cable Trenches In Hard Rock / C . C / Bituminous By Pneumatic Excavator I/C Laying Of 80Mm Gi Pipe Upto 30Cm Depth , Disposal Of Excavated Malba At Safe Place From The Site I/C Repairing Of The Excavated Trench With Cement , Course Sand Etc As Required And Making The Good Same Etc Complete As Required . , Earthing With G . I . Earth Pipe 4 . 5 Meter Long , 40 Mm Dia . Including Accessories , And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc . With Charcoal/Coke And Salt As Required . , Removing Of Tiles/Curve Stone Safely Without Any Damage Caused To Them & Fixing It By Using Sand/Cement Etc . As Required In Original Shape As Before When Ongoing Digging Work Completed I/C Dumping Of Malba From Site To Safe Dumping Zone . ( Note- Without Removing Of The Malba From Site Completion Shall Not Be Recorded . ) , Supply & Fixing Of Polycarbonate Feeder Pillar Suitable Of Outdoor Installation Made Up Of High Quality Thermoplastic Polycarbonate Having Dimension 1600X950x300 Mm Having 4 Strip Busbar Of 200 Amp Capacity , Totally Enclosed , Corrosion Free , Uv Resistant , Anti Acidic , Halogen And Silicon Free , Flame Retardant , Having High Impact ( Ik 08 ) , Internally Embedded High Grade Gasket Made Of Polyurethane , The Gasket Should Withstand Glow Wire Test At 960 Degree C In Accordance With Iec 60 695-2-11 , Should Be Flame Retardant , Self-Extinguishing . Panel Duly Fixed On Ms Angle Iron Frame Work Of Size 50Mm X 50Mm X 6Mm ( Ns ) 90 Cm Long Legs Out Of Which 45 Cm Duly Grouted In Cement Concrete 1:2:4 ( 1 Cement : 2 Sand :4 Stone Aggrete 20Mm ) . Cable Entry Should Be With Cable Glands , Having Ip 65 Degree Of Protection . Feeder Pillar Should Be Outdoor Type Having Ip-65 Degree Of Protection In Accordance With Iec 60529 & Providing & Fixing Following Accessories , Making Connections , Interconnections With Suitable Capacity Copper Conductor Wires- ( A ) 100 Amp , 16 Ka Tpmccb -1No . ( Ics=100% Icu ) ( B ) 50 To 63 Amp , Tpmccb , 16 Ka - 2 Nos . ( Ics=100% Icu ) ( C ) Digital Voltmeter-1No . ( Range= 0 To 500V ) , ( D ) Digital Ammeter-1No . ( Range= 0 To 200A ) ( E ) Indication Lamps ( Ryb ) - 3 Nos . ( F ) Power Contactor 3 Pole -70 Amp-1No . ( G ) Digital Timer-1No . ( H ) Danger Notice Plate- 2 Nos . ( I ) Arrangement Of Locking System In Front Door- 2 Nos .