Facilitating Electric Equipments At Eco Log Hut At Jammu Tawi Golf Course , Sidhra , Jammu - 2 Wiring For Circuit / Sub Main Wiring Alongwith Earth Wire With The Following Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required Make: Kei / Finolex / Polycab 3 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earthwire 4 2X4 Sq.Mm + 1X4 Sq.Mm Earthwire 5 2X2.5 Sq.Mm + 1X2.5 Sq.Mm Earthwire 6 Supply, Testing And Commissioning Of 2.0 Tr Split Ac, Units, Inverter Technology Energy Efficient With Minimum 4 Star Rating. All Weather Type With Temp Range -15 Degree C To 52 Degree C With Copper Coil Make Hitachi, O General, Diakin 7 Supply, Fitting, Commissioning And Testing Of Copper Pipe With 9Mm Thick Nitrate Insulation Foam To Connect Outdoor Unit With Installed Indoor Unit Fixing All Holes Back As It Was Earlier. 8 Supply, Testing, Fixing And Commissioning Of Wall Mounted Modular Type Voltage Stablized Copper Winding With Voltage Range As I / P 90 To 270V And O / P 220 To 250 V Make V-Gaurd, Ifb, Livgaurd, Bluebird. 9 Supply, Fixing And Commissioning Of 32 A Modular Type Mcb With All Fittings To Switch On / Off Ac Make L&T, Anchor, Legrand 10 Providing, Fixing Of 25Mm Pvc Drain Pipe For Installed Ac And Fixing All Holes Back As It Was Earlier. Make : Supreme / Astral / Finolex 11 Supply, Fitting, Commissioning And Testing Of 80 Cm ( 32 ) Smart Led Tv With All Fittings To Be Mounted On Wall. Contractor Must Also Supply Set Top Box With Complete Fitting.Make Mi, Lg, Smasung 12 Supply And Laying Of 70 Sq.Mm 3.5 Core Aluminium Armoured Cable With Thimbling And Tapping As Required At Site By Digging Crunch Of 1Mtr Deep And 0.75 Mtr Wide And Covering It Back As Per The Level Before Digging. Make : Polycab / Kei / Gloster 13 Providing, Fixing And Laying Of Hdpe Pipe ( 4 Size ) To Protect Cable Against Any External Damage And Fixing It With The Help Of Nuts, Bolts And Clamps 14 Fabrication , Supply And Fixing Of Wall Mountable L Type Clamps Made Of 50X50x6 Ms Angle With Horizontal Clearnace Of 6 Inches And Vertical Clearnace Of 4 Inches With Clamp Made Of 50X6 Ms Flat. 15 Supply, Testing, Fixing And Commissioning Of Wall Mounted Water Purifier With Ro Tm Technology And Inbuilt Tds Controller. Its Purificatoin Production Rate Must Not Be Less Than 40 L / Hr With Max Duty Cycle 200 L / Day Also. Min / Max Operating Ph Value As 2-11. 16 Supply, Testing, Fixing And Commissioning Of Wall Mounted Water Purifier 8 Liter Mineral Ro+Uv+Uf Water Purifier. Make Kent, Lg , Aquaguard 17 Supply, Testing, Fixing And Commissioning Of 36 Celling Fan. Make Usha. Orient, Havels 18 Supply, Testing, Fixing And Commissioning Of Modular Type 18W Electronic Tube. Make Orient, Havells, Cg, Syska, Indiabull 19 Supply Of Lt Panel Board Outdoor Type Floor Mounted, Dust And Vermin Proof Factory Made Fabricated Out Of 2Mm Thick Crca Sheet Complete Panel Painted With Powder Coating Suitable For 3 Phase, 415 Volt, 50 Hz Ac Supply Aluminium Bus Bar With Capacity Of 200 Amp.For 3 Phase And 4 Wire System With Proper Space To Install Mcb With Surge Prtection For Class B+C ( Dimension: 1.00”X 2.00”X 3.00” Leg Height : 2.5” Feet ) Make: Any Local Ssi Regd Unit With Cpri Apporval. 20 Supply And Fixing Following Rating Four Pole ( Three Phase And Neutral ) 415 V Residual Circuit Breaker Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commmissioning Etc. As Required Make L&T, Siemens, Legrand. 21 63 A 22 Supplying And Fixing 5A To 32A Rating, 240 / 415 V, 10 Ka ‘C’ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. Make L&T, Siemens, Legrand. 23 Single Pole 24 Single Pole And Neutral 25 Triple Pole And Neutral 26 Supplying And Fixing Of Following Modular Switches / Socket On The Existing Modular Plate And Switch Box Incld. Connections But Excld. Modular Plate Etc. Make Havell, Polycab, Anchor ( Roma ) 27 5 / 6 A Switch 28 15 / 16 A Switch 29 3 Pin 5 / 6 A Socket Outlet 30 6 Pin, 15 / 16 A Socket Outlet 31 Supplying And Fixing Following Size / Modules, G.I Box Alongwith Modular Base And Cover Plate For Modular Switches In Recess Etc. Make Havells, Polycab, Anchor ( Roma ) . 32 3 Module ( 100Mm X 75Mm ) 33 4 Module ( 125Mm X 75Mm ) 34 6 Module ( 200Mm X 75Mm ) 35 8 Module ( 125Mm X 125Mm ) 36 12 Module ( 200Mm X 150Mm ) 37 Supplying And Fixing Following Modular Base And Cover Plate On Existing Modular Metal Box Etc. Havell, Polycab, Anchor ( Roma ) 38 3 Module 39 4 Module 40 6 Module 41 8 Module 42 12 Module 43 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Incld. Connections But Excld. Modular Plate Etc. Make Havells, Polycab, Anchor ( Roma ) 44 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate And Switch Box Excld. Modular Plate As Required. 45 Wiring Of Light / Fan / Exhaust Fan / Call Bell Point With 1.5 Sq. Mm Frls Pvc, Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit With Modular Switch, Modular Plate, Suitable G.I Box And Earthing The Points With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. Make Havells, Polycab, Anchor ( Roma ) .