| 1 | 1 | ProvidingHighmast LED Luminaries | | | |
|---|
| 2 | 1.01 | Supply of 20 M high mast shaft in two section(BMRLMW20L) suitable for wind speed for 39 M/Sec , with raising lowering system comprising, head frame, luminaries carriage suitable to install 6 nos luminaries in symmetrical arrangement, double drum winch, 6 mm diameterSS wire rope, trailing cable, connector, integral power tool motor, manual handle,junction box, lightening finial etc as required. | item1 | 1 | Nos |
|---|
| 3 | 1.02 | Supply of Foundation bolts manufactured from special steel along with Nuts, washers, anchor plates and templates suitable for 12mtr lamp | item2 | 1 | set |
|---|
| 4 | 1.03 | Supply of 8 M fixed Mini Mast BOP 8030(Bajaj or equilent Philips make) with suitable ring bracket and foundation bolt. | item3 | 1 | Nos |
|---|
| 5 | 1.04 | Supply of 350W LED Flood Light luminaire(IP 66 protection BENP 20FL 350W LED Bajaj make or Equilent Philips make. | item4 | 3 | Nos |
|---|
| 6 | 1.05 | Supply of 200 W LED Flood Light luminaire(IP 66 protection BENP 20FL 220W LED Bajaj make or Equilent Philips make. | item5 | 3 | Nos |
|---|
| 7 | 1.06 | Supply of 120 W LED Flood Light luminaire(IP 66 protection BENP 20FL 120 W LED Bajaj make or Equilent Philips make. | item6 | 5 | Nos |
|---|
| 8 | 1.07 | Twin dome Aviation Obstruction Lights of LED type | item7 | 1 | Nos |
|---|
| 9 | 1.08 | Supply and providing OBO Bettermann Make V25-B+ C/1+NPE (switching surge/Lightning protection) for Single Phase Protection | item8 | 1 | Nos |
|---|
| 10 | 1.09 | Supply and installation of outdoor stand mounted feeder pillar suitable for full control of luminaries with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, 2 Nos 9A contactors and raise lower push button,Incoming 10 sq. mm and out going 6 & 2.5 sq. mm terminals and space for accomadating KSEB meter board and cutouts. | item9 | 1 | Nos |
|---|
| 11 | 1.1 | Supply and installation of outdoor stand mounted feeder pillar suitable for full control of luminaries with 32ADP MCB incomer, single dial time switch, 25A DP contactor for the automatic switching of luminaries, 8 way MCBDB with 25 A dp isolator as incomer and 6 Nos 6 A MCB as outgoings and out going etc complete. | item10 | 1 | Nos |
|---|
| 12 | 1.11 | Errection of 20 M High mast lighting system on existing concrete foundation with all tools and plants Mini crane etc and wiring of luminaires with 1.5 sq mm PVC insulated PVC sheathed flexible copper conductor 3 core chord etc as required | item11 | 1 | Nos |
|---|
| 13 | 1.12 | Errection of 8M High mast lighting system on existing concrete foundation with all tools and plants Mini crane etc and wiring of luminaires with 1.5 sq mm PVC insulated PVC sheathed flexible copper conductor 3 core chord etc as required | item12 | 1 | Nos |
|---|
| 14 | 1.13 | Supply and providing plate earthing as per IS 3043 GI funnel with wire mesh ,filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in hard soil) | item13 | 4 | Nos |
|---|
| 15 | 1.14 | Supply and providing coverings for the inspection chamber of earth pit as required -300 x 300 x 6 mm cast iron gully trap with covering | item14 | 4 | Nos |
|---|
| 16 | 1.15 | Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.-2 x 25 x 3 mm GI strip | item15 | 1.2 | Mtr |
|---|
| 17 | 1.16 | Supply and providing earth lead from the test joint to the earth electrode/High mast base using the following sizes of conductors/strips includingcutting, drilling necessary holes (in case ofstrip) and fixing firmly with plate test joint etc as required-25 x 3 mm GI strip | item16 | 45 | Mtr |
|---|
| 18 | 1.17 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required-3.15 mm copper conductor (10 SWG) | item17 | 30 | Mtr |
|---|
| 19 | 1.18 | supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required-3.15 mm (10 SWG) | item18 | 12 | Nos |
|---|
| 20 | 1.19 | Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required-25 x 6 mm brass bolt & nut | item19 | 12 | Nos |
|---|
| 21 | 1.2 | Earth work excavation in ordinary soil and depositing with a lead up to 50 m and lift above 1.50 m but up to 3.00 m including neat banking | item20 | 2 | m3 |
|---|
| 22 | 1.21 | Cement concrete 1:2:4 using 20mm (nominal size) broken stone for reinforced concrete work. | item21 | 2 | m3 |
|---|
| 23 | 1.22 | Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel | item22 | 200 | kg |
|---|
| 24 | 1.23 | Plastering with cement mortar 1:4, 12mm thick one coat. | item23 | 2 | m2 |
|---|
| 25 | 1.24 | Colour washing, two coats | item24 | 2 | m2 |
|---|
| 26 | 1.25 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required-4 core 10 sq mm | item25 | 135 | Mtr |
|---|
| 27 | 1.26 | 2 core 6 sq mm | item26 | 85 | Mtr |
|---|
| 28 | 1.27 | Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in hard soil 1.2m below ground level including excavation-40 / 32 mm or nearest size | item27 | 220 | Mtr |
|---|
| 29 | 1.28 | Supplying siemens / tropodur type nickel plated Double compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as require-10 sq mm | item28 | 4 | Nos |
|---|
| 30 | 1.29 | Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required-4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip | item29 | 4 | Nos |
|---|
| 31 | 1.3 | Supply of superior quality aluminium tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required-10 sq mm | item30 | 8 | Nos |
|---|
| 32 | 1.31 | S&D 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes-10 sq mm 4 run | item31 | 2 | Mtr |
|---|
| 33 | 1.32 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of 4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required | item32 | 1 | Nos |
|---|
| 34 | 1.33 | Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required -6-32A 10KA, SP MCB( C curve) | item33 | 15 | Nos |
|---|
| 35 | 1.34 | 40 A double pole mini break isolator | item34 | 1 | Nos |
|---|
| 36 | 1.35 | 40 A four pole mini break isolator | item35 | 1 | Nos |
|---|
| 37 | 1.36 | 32A, 10 kA, TP MCB (C curve) | item36 | 1 | Nos |
|---|
| 38 | 1.37 | 40 A, 4 pole, 100 mA RCCB | item37 | 1 | Nos |
|---|
| 39 | 1.38 | 50 A to 63 A, 10 kA, 4 pole MCB (C curve) | item38 | 1 | Nos |
|---|
| 40 | 1.39 | 40 A, 2 pole, 100 mA RCCB | item39 | 1 | Nos |
|---|
| 41 | 1.4 | Supply and Installation / Fixing / Provision of Outdoor type HENSEL make (450x300x214 mm -Mi 2310) Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof),rust , dust , water,corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable mounting plate and having a provision for Fuse / MCB cutout with complete tamper proof SEALING facility.\n | item40 | 1 | Nos |
|---|
| 42 | 1.41 | Supply and fixing the following accessories in the existing meter board and giving connections etc-Supply and fixing63 A, 415 V Backelite fuse fittingin the existing meter board and giving connections etc. | item41 | 3 | Nos |
|---|
| 43 | 1.42 | 63A fuse holder for BS type blade fuses. | item42 | 3 | Nos |
|---|
| 44 | 1.43 | 35-63 A, bolted offset tag type fuse link of size A1L | item43 | 3 | Nos |
|---|
| 45 | 1.44 | 63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base | item44 | 1 | Nos |
|---|
| 46 | 1.45 | Fabrication, supply, and fixing name plate board made out of sheet steel, including painting with two coats of synthetic enamel paint over a coat of zinc chromate primer,painting letters with suitable colour bolting the bord to the post using required bolt,nuts and clamp, etc. as required. | item45 | 1 | Nos |
|---|
| 47 | 1.46 | Charges for preparing drawing of the complete Electrical installation after completion of the present work and preparing completion report with KSEB service connection application and submitting to the KSEB for availng 3 phase service connection including fees for convertion of existing single phase srevice connection to 3 phase service connection etc complete(exiting single phase line and meter connection is available.Line extension of 2 phases approximate length of 100 mtr is necessary) | item46 | 1 | Job |
|---|