Repairs/Maintenance Of Internal Electrical Fittings/Fixtures , Earthing , Geysers , Exhaust Fans , Security Lights And Allied Works At Pedong , Algarah , Dalapchand , Ap Algarah And Teesta Tcp Under Ge 867 Ews
Tender Value
32 Lakhs
Estimated cost
Bid Submission
16 Dec 2019
0 days left
EMD
64000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pedong → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repairs/Maintenance Of Internal Electrical Fittings/Fixtures , Earthing , Geysers , Exhaust Fans , Security Lights And Allied Works At Pedong , Algarah , Dalapchand , Ap Algarah And Teesta Tcp Under Ge 867 Ews
BOQ
| Name of Work: REPAIRS/MAINTENANCE OF INTERNAL ELECTRICAL FITTINGS/FIXTURES, EARTHING, GEYSERS, EXHAUST FANS, SECURITY LIGHTS AND ALLIED WORKS AT PEDONG, ALGARAH, DALAPCHAND, AP ALGARAH AND TEESTA TCP UNDER GE 867 EWS | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Approx No of Units Reqd | UNIT | |
| 1 | 1 | M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 1.5 Sq mm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one light /fan point controlled by one switch/one bell / buzzer point controlled by one bell push/one 3 / 5 -pin switch socket outlet 5 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge. | 130 | POINT | |
| 2 | 2 | All as per item No.1 above but for One 3/5 pin switch socket outlet 5 amps on same board along with other switches complete all as specified and directed by Engineer-in-Charge. | 30 | POINT | |
| 3 | 3 | M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 2.5 Sqmm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one 5 / 6 -pin switch socket outlet 15 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge. | 20 | POINT | |
| 4 | 4 | M&L for sub main wiring complete with 2 runs of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including non metalic rigid PVC casing & caping of 25mm size fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge.\nNote: 3 runs of 6 Sqmm and one run of Casing&Caping shall be measured as one unit length. | 50 | RUNNING METRE | |
| 5 | 5 | M&L for sub main wiring complete with 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including non metalic rigid PVC casing & caping of 25mm size fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge.\nNote: 3 runs of 4 Sqmm and one run of Casing&Caping shall be measured as one unit length.\nMake for Item No. 1 to 5\nCable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor\nCasing&Caping: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza | 50 | RUNNING METRE | |
| 6 | 6 | S&F switch piano, flush button, single pole, 5 amps, one way complete all as specified and as directed by Engineer-in-Charge. | 130 | EACH | |
| 7 | 7 | S&F socket outlet 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type complete all as specified and as directed by Engineer-in-Charge. | 30 | EACH | |
| 8 | 8 | S&F switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type complete all as specified and as directed by Engineer-in-Charge. | 30 | EACH | |
| 9 | 9 | S&F switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type complete all as specified and as directed by Engineer-in-Charge. | 20 | EACH | |
| 10 | 10 | S&F ceiling rose, 3 terminal, PVC/Polycarnonate insulated body complete all as specified and as directed by Engineer-in-Charge. | 80 | EACH | |
| 11 | 11 | S&F lamp holder, PVC/Polycarnonate insulated body with back plate for batten fittings complete all as specified and as directed by Engineer-in-Charge.\nMake for Item No. 6 to 11: (i) Anchor (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh | 20 | EACH | |
| 12 | 12 | S&F sheet metal enclosure DB SPN 8 way 240 V with 200 Amp rated bus bar, powder coated, double door including taking down old unserviceable DB complete all as specified and as directed by Engineer-in-Charge. | 10 | EACH | |
| 13 | 13 | S&F sheet metal enclosure DB SPN 4 way 240 V with 200 Amp rated bus bar, powder coated double door including taking down old unserviceable DB complete all as specified and as directed by Engineer-in-Charge. | 10 | EACH | |
| 14 | 14 | Supply and Fixing of MCB SPN 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz including taking down old unserviceable MCB complete all as specified and as directed by Engineer-in-Charge. | 10 | EACH | |
| 15 | 15 | Supply and Fixing of MCB SPN 40 Amps, 10 KA breaking capacity, 240 volts, 50 Hz including taking down old unserviceable MCB complete all as specified and as directed by Engineer-in-Charge. | 10 | EACH | |
| 16 | 16 | Supply and Fixing of MCB SP 6 to 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz including taking down old unserviceable MCB complete all as specified and as directed by Engineer-in-Charge. \nMake for Item No. 12 to 16: HPL/INDOASIAN/ HAVELLS/C&S/ STANDARD | 80 | EACH | |
| 17 | 17 | S&F Regal batten box type suitable for LED T-8 lamps, with bipin holders, connector block etc., complete with all accessories internally prewired and including connecting up with three core pvc sheathed flexible copper conductor cable of size 1 sqmm including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.\nMake: Cat part IGP131LT8-16 of Crompton or equivalent in Philips/Havells/Bajaj/Wipro. | 219 | EACH | |
| 18 | 18 | S&F Energy efficient linear LED Tube light T8 tubular lamp with extruded aluminium body, PC diffuser and with inbuilt driver of 1 x 20 watt ultra bright LED tube light with very high efficiency suited for installation in box type batten including taking down existing tube light complete all as specified and as directed by Engineer-in-Charge.\nMake: Cat part LTT8-20 of Crompton or equivalent in Philips/Havells/Bajaj/Wipro. | 400 | EACH | |
| 19 | 19 | S&F LED modular energy eefficient luminarie LED batten with polycorbonate housing and integrated electronic driver (warm white 3000K) complete with all accessories internally prewired and including connecting up with three core pvc sheathed flexible copper conductor cable of size 1 sqmm including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.\nMake: Cat part LUMELINEBS18WLED830SPCWH of Havells or equivalent in Philips/Crompton/Bajaj/Wipro. | 100 | EACH | |
| 20 | 20 | Supply and fixing integrated LED bulk head luminaries comprises of pressure die cast housing with clear acrylic diffuser & frame and IP 65 protection including 10 W LED bulb and connecting up with existing cable including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.\nMAKE: Cat part No. LBHN-10-CDL of Crompton or Philips Cat no. WT202WLED 6S NW PSUS2PC or Cat No. RUGBYNEONFT10WLED860 SSYMTOPC of Havells or equivalent in Bajaj. | 20 | EACH | |
| 21 | 21 | S&F 36 Watt LED endura flat panel SKYLUX Recess mounting LED 2x2 luminare, white, powder coated CRCA housing with LEDs seamless front frame with flat white high transmission acrylic cover complete with all accessories internally prewired and connecting up with three core PVC sheathed flexible copper conductor cable of size 1 sqmm including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.\nMAKE: Cat No. VENUSNEOHE2X2PLR18-42WLED830MOD of Havells or equivalent in Philips/Crompton/Bajaj/Wipro. | 30 | EACH | |
| 22 | 22 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, 15 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge.\nNOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m. | 27 | EACH | |
| 23 | 23 | S&F LED PL lamp 4 pole 18 watts including taking down existing lamp complete all as specified and as directed by Engineer-in-Charge.\nMake: Cat No. PHOTONULTRAPLL419L18LED865SPC of Havells or equivalent in Philips/Crompton/Bajaj/Wipro. | 20 | EACH | |
| 24 | 24 | S&F PL lamp 4 pole 36 watts including taking down existing lamp complete all as specified and as directed by Engineer-in-Charge.\nMake: Havells/Philips/Crompton/Bajaj/Wipro. | 400 | EACH | |
| 25 | 25 | S&F Electronic ballast suitable for 2 x 36/40 watts PL lamp including taking down existing ballast complete all as specified and as directed by Engineer-in-Charge.\nMake: Havells/Philips/Crompton/Bajaj/Wipro. | 300 | EACH | |
| 26 | 26 | S&F Electronic ballast suitable for 1 x 36/40 watts PL lamp including taking down existing ballast complete all as specified and as directed by Engineer-in-Charge.\nMake: Havells/Philips/Crompton/Bajaj/Wipro. | 200 | EACH | |
| 27 | 27 | S&F Pin holder suitable for PL lamp 4P including taking down existing holder complete all as specified and as directed by Engineer-in-Charge.\nMake: Havells/Philips/Crompton/Bajaj/Wipro. | 50 | EACH | |
| 28 | 28 | S&F tube rod 36/40 watts including taking down existing tube rod complete all as specified and as directed by Engineer-in-Charge.\nMake: Havells/Philips/Crompton/Bajaj/Wipro. | 200 | EACH | |
| 29 | 29 | S&F celing light driver of 36 watts 240 V AC, 50 Hz with suitable technical (Vin-240V AC, lin 170mA, P in 36 W +/- 10%, Volt 800 mA) including taking down existing celing light fitting from existing position and refixing after replacement of driver complete all as specified and as directed by Engineer-in-Charge.\nMake: Cat No: 36 W LED CC driver (SLE FP 36 R22) of Surya or eqivalent in Havells/Philips/Crompton/Bajaj/Wipro. | 50 | EACH | |
| 30 | 30 | Taking down the existing unserviceable exhaust fan/wall fan of any make/ model 450mm/400mm/300mm/200mm sweep dismantling and re-assembling after lubricating greasing, overhauling/ servicing cleaning and replacing unserviceable components, reinstalling in its original position connecting, testing and commissioning complete all as specified and directed by the Engineer-in-charge.complete all as specified and directed by Engineer-in-Charge.\nNote:- Supply only bearing/gunmetal bush/rubber bush & bolts / capacitor/ rewinding/ cord flexible/ shaft etc., shall be measured and paid separately. | 24 | EACH | |
| 31 | 31 | Supply only ball bearing suitable for exhaust fan of 450mm sweep of any make model complete all as directed by Engineer-in-Charge. | 10 | EACH | |
| 32 | 32 | Supply only ball bearing suitable for exhaust fan of 300/250/200 mm sweep of any make model complete all as directed by Engineer-in-Charge.\nMake for item Nos. 31 & 32:- NBC/ TATA/ SKF\n | 10 | EACH | |
| 33 | 33 | Supply only capacitor of 2.5 mfd complete all as directed by Engineer-in-Charge. | 9 | EACH | |
| 34 | 34 | Supply only capacitor of mfd complete all as directed by Engineer-in-Charge.\nMake for item No. 33&34:- CAPCO/ TIBCON/ CROMPTON \n\n | 2 | EACH | |
| 35 | 35 | Supply only rubber reel with bolt and nut suitable for exhaust fan of any make/ model/ sweep complete all as directed by Engineer-in-Charge.\n\n | 4 | EACH | |
| 36 | 36 | M&L for rewinding of Exhaust fan/wall fan of any make/model of 450/400 mm sweep, including removal of existing burnt winding carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enameled copper wire of existing gauge complete all as directed by Engineer-in-Charge.\n | 5 | EACH | |
| 37 | 37 | M&L for rewinding of Exhaust fan/wall fan of any make/model of 300/250/200 mm sweep, including removal of existing burnt winding carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enameled copper wire of existing gauge complete all as directed by Engineer-in-Charge.\n | 5 | EACH | |
| 38 | 38 | Supply only 1.5 KW capacity Heating Element, Push/ Screw type with ‘O’ ring including making electrical connection complete all as directed by Engineer-in-Charge. | 10 | EACH | |
| 39 | 39 | Supply only 2.0 KW capacity Heating Element, Push/ Screw type with ‘O’ ring including making electrical connection complete all as directed by Engineer-in-Charge.\nMake for Item No. 38&39: Bajaj/Venus/Racold/Havells/Crompton/Power pack or equivalent as approved by GE. | 10 | EACH | |
| 40 | 40 | Material and Labour for Thermostat switche for geysers 25/ 50 Ltr capacities including making connection complete all as directed by Engineer-in-Charge. | 20 | EACH | |
| 41 | 41 | Supply & fixing in replacement 300mm long chromium plated copper pipe connection (Heavy Duty) with two numbers brass adopters for fixing one end at geyser & other end at water outlet point for hot water complete all as specified and directed by Engineer-in-Charge. | 10 | EACH | |
| 42 | 42 | Supply and fixing in replacement indicator lamp round /rectangular and making electric connections (Red/Green) 220 Volts AC as per site requirement suitable for geysers complete all as directed by Engineer-in-Charge. | 10 | EACH | |
| 43 | 43 | Design, supply, install, testing and commissioning of lightening protection system of Early Streamer Emission type lightning spike with GI mast of 8.5 mtrs alongwith all mounting structures and civil works and shall be executed as per applicable IS/IEC 62305 standards including taking down existing lightning protection system complete all as specified and directed by Engineer-in-Charge \nMake: - Nimbus/Indelec/Tarcel/SGI | 4 | EACH | |
| 44 | 44 | M&L in replacement of U/S plate earthing with chemical earthing of copper electrode of size (50 x 300mm) with chemical bag of Aluminium Silicate 20 kg at 3.3 mtr deep connected with aluminium strip of size 32 x 6 mm thick by means of bolts nuts check nuts and washers of galvanised iron or stell all as specified and testing on completion including all excavation and earth work in type of soil/hard rock incl PCC pit (1:3:6) type C-1 with RCC cover complete all as specified and directed at site . Cost of excavation of soft/hard rock deemed to be included in the quoted rate. | 17 | EACH | |
| 45 | 45 | S&F Air termination , single pointed aluminium rod 12mm dia 300mm long including removing unserviceable one complete all as specified and as directed. | 40 | EACH | |
| 46 | 46 | S&F aluminium strip 25 x 3.15 mm thick saddle/mounted on porcelain/wooden insulator etc. for roof conductors and down conductors above ground and including removing unserviceable one complete all as specified and as directed by Engineer-in-charge. | 71 | RUNNING METRE | |
| 47 | 47 | S & F wooden seperator of 2nd class hard wood in scantlings of size 150mmx100m x50mm fixed with two nos bolts nuts and washers of required sizes including removing unserviceable one complete all as specified and as directed by Engineer-in-charge. | 0.1 | CUBIC METRE | |
| 48 | 48 | Taking down LED 150/120/100/90/80/60/45/30/25 watts energy efficient street light fitting, identifying the fault, repair / replacement of old unserviceable accessories with new accessories, re-assembling and make the street light fitting functional and re-fixing in existing location and connecting with three core copper PVC insulated conductor of 1 Sqmm size (nominal area) of suitable length to connect the luminaries to overhead conductor/existing lines complete all as specified and as directed.\nNote:- Spare parts and PVC cable for connection required for repair to street light fittings shall be measured and paid separately under relevant items as supply only.\n | 100 | EACH | |
| 49 | 49 | Supply only three core copper PVC insulated PVC sheathed multi core cble with electrolytic grade annealed copper copper conductor suitable upto 1100V grade confirming to IS:694 conductor of 1 Sqmm size (nominal area) complete all as specified and directed by EIC.\nMake: Havells/Polycab/Finolex or equivalent as approved by GE. | 610 | RUNNING METRE | |
| 50 | 50 | Supply only in replacement of LED street light driver of 150 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC.\nMake: SURYA/HAVELLS/ CROMPTON/ or equivalent as approved by GE. | 2 | EACH | |
| 51 | 51 | Supply only in replacement of LED street light driver of 120 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC.\nMake: SURYA/HAVELLS/ CROMPTON/ or equivalent as approved by GE. | 2 | EACH | |
| 52 | 52 | Supply only in replacement of LED street light driver of 100 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC.\nMake: SURYA/HAVELLS/ CROMTON/ or equivalent as approved by GE. | 5 | EACH | |
| 53 | 53 | Supply only in replacement of LED street light driver of 90 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC.\nMake: SURYA/HAVELLS/ CROMTON/ or equivalent as approved by GE. | 5 | EACH | |
| 54 | 54 | Supply only in replacement of LED street light driver of 80 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC.\nMake: SURYA/HAVELLS/ CROMPTON/ or equivalent as approved by GE. | 5 | EACH | |
| 55 | 55 | Supply only in replacement of LED street light driver of 60 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC.\nMake: SURYA/HAVELLS/ CROMPTON/ or a equivalent as approved by GE. | 5 | EACH | |
| 56 | 56 | Supply only in replacement of LED street light driver of 45 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC.\nMake: SURYA/HAVELLS/ CROMTON/ or equivalent as approved by GE. | 5 | EACH | |
| 57 | 57 | Supply only in replacement of LED street light driver of 30 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC.\nMake: SURYA/HAVELLS/ CROMPTON/ or equivalent as approved by GE. | 5 | EACH | |
| 58 | 58 | Supply only in replacement of LED street light driver of 25 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC.\nMake: SURYA/HAVELLS/ CROMPTON/ or equivalent as approved by GE. | 5 | EACH | |
| 59 | 59 | Taking down existing worn out GI brackets from pole and supply and fixing GI pipe bracket made out of 40mm dia GI pipe (light grade of length 1.5 meter) bent to the required shape for holding the fitting with proper angle including providing two pair of MS flat iron clamps of size 40mm x 6mm of required length duly drilled for bolt holes with required nuts, bolts and washers of suitable size, including applying two coats of aluminium paint over a coat of red oxide primer to clamps after perparation of surfaces complete all as specified and as directed. | 10 | EACH | |
| 60 | 60 | S & F MCCB four pole 63 Amp, 415 Volts, 'C' Curve, 25 KA breaking capacity, Ics=100% Icu including taking down existing MCCB complete all as specified and directed by Engr-in-Charge.\nMake: LEGRAND /SIEMENS/SCHNEIDER. | 2 | EACH | |
| 61 | 61 | Material and labour for 40 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection or as in stand for post top lantern including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge.\nMake: TATA/ZENETH/JINDAL or equivalent as approved by GE.\n | 42 | RUNNING METRE | |
| 62 | 62 | Material and labour for taking down/up existing 40 mm dia bore GI tubing Light grade, and refixed/ laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection or as in stand for post top lantern complete all as specified and directed by Egineer-in-Charge.\n | 6 | RUNNING METRE | |
| 63 | 63 | Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.\nNote:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI | 100 | RUNNING METRE | |
| 64 | 64 | Taking out existing cable and relaying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge.\nNote:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. | 25 | RUNNING METRE | |
| 65 | 65 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5 in depth for taking out /laying of cable etc., and getting out in soft/loose soil.complete all as specified and directed by Engineer-in-Charge. | 22 | CUBIC METRE | |
| 66 | 66 | Returning, filling in soil, including spreading leveling, watering and wall ramming in laying not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge. | 13 | CUBIC METRE | |
| 67 | 67 | Removing excavated soil to a distance n.exe 50m and depositing where directed at alevel n.exe 1.5m above the starting point complete all as directed by Engineer - in -Charge. | 8 | CUBIC METRE | |
| 68 | 68 | Supply and spreading of dry sand in trenches for cable coushioning and punned down complete all as specified and directed by Engineer-in-Charge.\nNote:- Punned thickness only shall be measured for payment purpose. | 6.5 | CUBIC METRE | |
| 69 | 69 | M&L for common burnt bricks, sub class 'B', of size 250 x 125 x 75 mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge. | 0.64 | ONE THOUSAND NUMBERS | |
| 70 | 70 | Supply & fixing LED street Light in aluminum PDC housing toughened glass cover with IP 66 protection of 80 Watt including lamp fixed toexisting bracket including electrical connection complete with 2 runs of 2.5 Sqmm single core copper cable ISI marked stranded to LT terminal box to fitting complete including taking down existing fitting all as specified and as directed. \nMake: SURYA cat part No. SLE UL 80W IP66 LXN or equivalent make of Havells/Philips/CG as approved by GE. | 20 | EACH | |
| 71 | 71 | S&F 3 Phase automatic streeet light switch using infrared sensor based nature swich the following features including taking down existing switch compete all as specified and directed.\n(a) Automatic switching on at dusk (30lux),Automatic switching off at dawn(10 lux)\n(b) No time setting or sesonal resetting or longitude -latitude setting \n(c) Over voltage and low voltage trip with auto reset.\n(d) The sensor(Nature switch ) along with suitable power contactors and input out put MCBsshould be enclosed in pole/wall mountable enclosure made of rust proof,shock proof, termite proof and FR grade SMC material(Sintex make or equivalent) and conforming to IP-66.\n(e) The contactors,MCBs and circuit wiring(minimum 16 sq mm) should be suitable enough to take 3-phase load of 8-KW/32 Amps per phase)\nModel : Swadeep-66-8kW3P(Nature switch/Sensor-Kakatiya/Bajaj/Healer.Contactors-BCH/L&T/Schneider.MCBs-Hager/Schneider/L&T, Circuit wiring -Poly cab/Finolex or equivalent) or equivalent model of Bajaj/Havells approved by GE. | 1 | EACH | |
| 72 | 72 | M&L for applying one coat of Aluminium paint over a coat of Aluminium Primer on 9/11 mtr long steel tubular pole in position after preparaiton of surface of steel tubular pole (Externally from Top of Coping) including all fitted cross arms, clamps and nuts, bolts etc including writing MES Pole No of pole size 70mm x 40mm by using stencil to the pole with approved palms 1.5 mtr above the ground level complete all as specified and as directed. | 317 | EACH | |
| 73 | 73 | Sub Total of Schedule 'A' | |||
| 74 | 74 | Schedule of Credit (Minus) Rs. 36,871.00 B/F from Ser page No. 33 \nNOTE: Bidder shall insert credit amount as rate Rs. 36,871.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender. | 1 | EACH | |
| 75 | 75 | Sub Total of Schedule of Credit |
AI Tender Summary
Tender Timeline
Nov 26, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedDec 16, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 17, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender