Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #22653188

E-Tender For Procurement Of Equipments Of Civil, Mechanical ,Electrical Engineering And Basic Science Labs Of Raisen And Lateri Polytechnic Institutes

Issued by Boards / Undertakings / PSU · Raisen and Lateri, Madhya Pradesh
Tender Value
25 Lakhs
Estimated cost
Bid Submission
05 Dec 2019
0 days left
EMD
75000
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Raisen and Lateri → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

E-Tender For Procurement Of Equipments Of Civil, Mechanical , Electrical Engineering And Basic Science Labs Of Raisen And Lateri Polytechnic Institutes - 2 3 Phase Rlc Load 1 Kw ( Variable ) Rlc Load Consists Of Following : N-Resistive Load 1 Kw:Loading Rheostat 1.5 Kw Three Phase ( Each Phase Of 0.5 Kw ) In 4 Steps. 3Phase Loading Rheostats Is Designed To Be Used As Loads In Electrical Laboratories. High Quality Rheostats Are Mounted Inside The Specially Designed Highly Ventilated Steel Cabinet. Selector Switches Mounted On Bakelite Front Panel For Load Selection. Fitted On Wheels For Easy Movement. Nloading Voltage : 415~440V Ac , 50Hz, 3 Phase Nloading Capacity : 1.5 Kw Three Phase ( 0.5 Kw Each Phase ) Nno Of Steps : 4 ( 125W Each Step ) Nrheostats : High Quality Wound With Constantan Wire ( Nickel - Copper Alloy ) N-Inductive Load 1 Kw, 10 Amp, Three Phase N-Capacitive Load 1 Kw, 10 Amp, Three Phase 3 Rheostat ( 100 Ohms / 5 Amp ) Range: 100 Ohms / 5 Amps Nsize: 18” X 2 1 / 4 “ Double Tube Nmaterial Used : Ncontact ( Double Contact System ) - Laminated Phosphorous Bronze, Nend Bands- Brass Nickled, Nformer- Porcelain Tube Nglide Rod- Brass, Nside Support- Mild Steel Nterminals- 4 Mm Bakelite Embedded With Brass, Nwire- Nichrome Resistance Wire. 4 Rheostat ( 300 Ohms / 2 Amp ) Range: 300 Ohms / 2Amps N24” X 21 / 4 “ Single Tube Nmaterial Used : Ncontact ( Double Contact System ) - Laminated Phosphorous Bronze, Nend Bands- Brass Nickled, Nformer- Porcelain Tube Nglide Rod- Brass, Nside Support- Mild Steel Nterminals- 4 Mm Bakelite Embedded With Brass, Nwire- Nichrome Resistance Wire. 5 Work Bench Electrical With Instruments Work Bench 5Ft X 2.5Ft, Height 2.5Ft With All Metallic Structure Fitted With Wheels With Logging Arrangements, Provided With Drawers With Lock And Key.The Work Bench Is Fitted With The Following Instruments: Na ) 3 Phase Variac, 28A, 0-470V, Nb ) Dso 100Mhz, 2Ch Nc ) Function Generator 25Mhz, Nd ) Dual Dc Regulated Power Supply, 0-30V , 5A Ne ) Digital Multimeter Suitable To Measure Ac / Dc Current, Ac / Dc Voltage, Etc., Nf ) Soldring & De - Soldring Station Ng ) Multifunction Meter To Indicate 3 Phase Voltage, Current, Frequency, Power Factor, Power, Etc. Ninput Supply 415V , Fitted With Tpn Mcb 32A, Output Sockets Of 5 / 15A 6 Function Generator Frequency : 0.5 Hz To 5 Mhz Function Generators With Sine , Square, Triangle, Ttl & Dc, 6 Digit , Auto Ranging 150 Mhz Frequency Counter Namplitude Modulation ( Internal & External ) Ninternal Am Signal Generator 400 Hz / 1 Khz Ndistortion Factor : < 0.5% Ninternal Lin / Log Sweep And External Frequency Modulation Ncmos Output Adjustable From 2 V To 14 V Nbacklit Lcd Display For Modes And Frequency Nmicroprocessor Based Design 7 Anderson Bridge With Inbuilt Digital Null Detector Nin Built Fixed Dc Regulated Power Supply Of ±5V±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Three Set Of Two Decade Dial X ( 10 W & 100W ) . Non Board Four Unknown Inductance & Two Standard Capacitor Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel Npower Requirement: 220 Vac +10%, 50Hz 8 Schering Bridge With Inbuilt With Digital Null Detector, Sinewave Oscillator Nin Built Fixed Dc Regulated Power Supply Of ±5V ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Ratio Dial “P” & “Q” Each Having 10 W, 100W & 1000W. Non Board Two Decade Dial X ( 0.01 Mf & 0.01Mf ) . Non Board One Variable Gang Capacitor Range Of 25Pf To 500Pf Non Board Six Unknown Capacitor Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel Npower Requirement : 220 Vac +10%, 50Hz 9 Kelvin Bridge ( Industrial ) With Dc Source & Galvanometer To Measure The Low Value Resistance. Nmultiplier Dial Is Provided On The Front Panel With Ranges X 0.01W, X0.1W, X1w, X10w, X100w. Nstandard Resistance Dial & Slide Wire Dial Are Also Provided On The Front Panel. Ntwo Press Keys Are Provided On The Front Panel Marked As Coarse And Fine. Ncurrent Reversing Switch Is Provided On The Front Panel To Get The Deflection On Left Or Right Nhand Side In A Galvanometer. Nterminals Are Provided On Front Panel To Connect Galvanometer & Dc Source. 10 Kelvin Bridge ( Student ) With Dc Source & Galvanometer One Ratio Box Of 1-1W, 0. 1-0.1W, 0.01-0.01W, 10-10W, 100-100W, For Connection Of Galvanometer. None Decade Dial Of X0.01W. Nslide Wire Of Resistance 0.05W With Scale Of 100 Equal Divisions. Nfour Terminals For Connecting Unknown Resistance Wire. Ntwo Terminals Are Provided For Battery. 11 Maxwell Inductance Bridge With Inbuilt Digital Null Detector, Sinewave Oscillator Multiplier Dial Is Provided On The Front Panel With Ranges X 0.01W, X0.1W, X1w, X10w, X100w. Nstandard Resistance Dial & Slide Wire Dial Are Also Provided On The Front Panel. Two Press Keys Are Provided On The Front Panel Marked As Coarse And Fine.Current Reversing Switch Is Provided On The Front Panel To Get The Deflection On Left Or Right, Hand Side In A Galvanometer. Nterminals Are Provided On Front Panel To Connect Galvanometer & Dc Source. N 12 Weins Bridge ( Capacity Measurement ) With Inbuilt Digital Null Ndetector, Sinewave Oscillator Nin Built Fixed Dc Regulated Power Supply Of ±5V , ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Set Of Two Decade Dial X ( 1W & 10W ) . Non Board Six Unknown Capacitor & Two Capacitor ( 0.033Mf & 1Mf ) Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel. Npower Requirement : 220 Vac +10%, 50Hz N 13 Weins Bridge ( Frequency Measurement ) With Digital Null Detector With Analog Function Generator 1Hz To 200Khz Nin Built Fixed Dc Regulated Power Supply Of ±5V & +5V / 500Ma. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Set Of Two Decade Dial X ( 0.01Mf& 0.1Mf ) . Non Board Three Decade Dial X ( 10 W , 100W & 1000W ) . Non Board Three Decade Dial X ( 1W , 10W & 100W ) . Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel. Npower Requirement : 220 Vac +10%, 50Hz N 14 Desauty Bridge With Inbuilt Digital Null Detector, Sinewave Oscillator Nin Built Fixed Dc Regulated Power Supply Of ±5V, ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Set Of Two Decade Dial X ( 10W & 100W ) . Non Board One Decade Dial X ( 0.1Mf ) . Non Board Six Unknown Capacitor Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel. Npower Requirement : 220 Vac +10%, 50Hz 15 Hays Bridge With Inbuilt Digital Null Detector, Sinewave Oscillator In Built Fixed Dc Regulated Power Supply Of ±5V, ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Decade Dial X ( 100 W & 1000W ) . Non Board Three Decade Dial X ( 10W, 100W & 1000W ) . Non Board Two Decade Dial X ( 0.01Mf & 0.1Mf ) . 16 Owens Bridge Owens Bridge With Decade Inductance Box With Sine Wave Oscillator & Decade Inductance Box With Sine Wave Oscillator & Inductance & Sensitive Head Phone 17 Idmt Over Current Relay Testing Kit Relay Type : Over Current Relay Idmt ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 18 Earth Fault Realy Testing Kit ( Electromechanical Type ) Relay Type : Earth Fault Relay Idmt ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer N0001sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm, Switches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 19 Percentage Bias Differential Relay Testing Kit ( Electromechanical Type ) Nrelay Type : Percentage Biased Differential Relay ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Rheostats To Set The Biased Current & To Vary The Differential Current Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps, 2Nos. Ac Current Nmeters 0 – 50Amps & 1 No. Ndigital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Nphantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz N 20 Transformer Protection Using Percentage Biased Diffrential Relay N ( Microprocessor Type ) Relay Type : Percentage Biased Diffrential Mib 202 Relay Nterminals : 4Mm Terminals For Rheostats To Set The Biased Current & To Vary The Differential Current Nmeters ( Digital ) : 2Nos. Ac Current Meter 0 – 20Amps, & 1 No. Digital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mmx48mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Createphantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 900Mm X 600Mm Npower Requirement : 420Vac +10%, 50Hz N N 21 Thermal Over Load Relay Testing Kit Relay Type : Thermal Relay Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer N.0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 22 Over Voltage Relay Testing Kit ( Electromechanical Type ) Relay Type : Over Voltage Relay ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Voltage Output And Input Nmeters ( Digital ) : 1No. Ac Voltmeter Meter 0 – 300V & 1 No. Digital Timer N.0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Nvoltage Injector : Inbuilt Variable Voltage Injector 250V To Create Fault Voltage Nindicators : Provided On Front Panel For Mains, Voltage, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 23 Under Voltage Relay Testing Kit ( Electromechanical Type ) Relay Type: Under Voltage Relay ( Electromechanical Induction Disc Type ) Nterminals: 4Mm Terminals For Trip, Voltage Output And Input Nmeters ( Digital ) : 1No. Ac Voltmeter Meter 0 – 300V & 1 No. Digital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Nvoltage Injector : Inbuilt Variable Voltage Injector 250V To Create Fault Voltage Nindicators : Provided On Front Panel For Mains, Voltage, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz N 24 Over Current Relay ( Directional Type ) Testing Kit N ( Electromechanical Type ) Relay Type : Directional Over Current Relay ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer N.0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nreversing Switch : To Reverse The Direction Of Current Nrelay Circuit Diagram : Screen Printed On Front Panel Npower Requirement : 220Vac +10%, 50Hz N N 25 Advance Plc Trainer Kit Nrs Logic 1000 / Licensed Software : Digital & Analog , Digital 16 Input 8 Output , Analog 8 Input 8 Output, Delta Based Plc Provided With Rs232 Serial Port For Pc Interfacing 26 Simens Tia Module S7-1200 / Licensed Software 27 Plc Control Panel 28 Interfacing Modules For Above Mentioned Plc Trainer 29 Module For Traffic Light Control 30 Module For Dol Starter Control 31 Module For Star Delta Starter Control 32 Module For Conveyer Belt Control 33 Module For Dc Motor Start, Stop Function 34 Module For Water Level Control 35 Module For Temperature Control 36 Module For Sequence Control 37 Module For Elevator Control 38 Scada Software:- Allean Bradely 39 Scada Software:- Wonderware Intuch Student Version :-Simens 40 Module For Elevator Control 41 Anchor Insulated Copper Pvc Cable 2.5 Sq Mm Wire ( 100M ) 42 3 / 20 Swg ( Phase Wiring ) ( 100M ) 43 3 / 22 Swg ( Neutral Wire ) ( 100M ) 44 6 Amp. Modular Switch Board 45 Two Way Switch ( 10 Amp ) 46 One Way Modular Switch ( 10 Amp ) 47 Lamp Holders 48 40W Bulb 3 Pvc Casing 49 Mcb ( 10 Amp ) 50 Fuses ( 10 Amp ) 51 Magic Power Bc-A6 10A Battery Charger 52 Battery Eliminator 53 Electrical Testing Panel 54 Lux Meter Lux Range: 2000, 20000, 50000Lux Nmax. Resolution: 1Lux Nbasic Accuracy: ±5% Fs Nfast Response: 0.2S Nslow Response: 0.4S Ncosine & Color Corrected, Analog Output, Monitor Light Levels Using Outputs; N1mv Per Count Analog Output For Capturing Readings To A Recorder, Supplied With Batteries, Light Sensor, Cable & Protective Cover 55 Smps Trainer Kit Switched Mode Power Supply ( Smps ) Using High Frequency Transformer & High Switching Transistor Has Been Designed To Study The Line And Load Regulation Characteristics Of Smps Power Supplies. Nrotary Switch For Selections Of Different Input Voltage & Linearity Coil For Ac Filtrations , Bridge Rectifier To Convert Ac Into Dc Ndc Filtrations Circuit Is Given To Filter The Impurities I.E. Ac Components. Nhigh Frequency Transformer And High Frequency Transistor ( Bu 508 ) For Switching Action. Nfeed Back / Comparator Circuit To Maintain Output Voltage Constant I.E. +10 % On Load. Two Meters Are Provided On The Front Panel To Measure The Dc Voltage & Current. Two Bulb Holder Are Mounted On The Front Panel To Connect Resistive ( Bulb ) Load Across The Output. Nblock Diagram Printed On Front Panel & Test Points Brought Out On Front Panel. Npower Requirement: 230 Vac +10%, 50Hz. 56 Ups Trainer Kit ( 500 Va ) • On Board Controller Pcb N• On Board Input / Output Transformer & Chargeable Battery N• Digital Panel Meter For Current Reading N• 5 Test Points Provided On Front Panel Only For Observations N• 5 Fault Switch Provided On Front Panel For Fault Creation N• Led Indicators For Status Mode N• Power Requirement: 220Vac+10%, 50Hz 57 Transformer Oil Testing Kit ( 0-80Kv ) Motorized With Digital Display Ninput : 230V Ac, Single Phase. Noutput : 0 –80 Kv, Center Tap Earthed, Ncapacity : 1 Kva Nindication: Mains ‘On And ‘Ht’ ‘On’ Indicating Lamps. Nmetering : 96 Sq. Mm. Size Back Of Panel Mounting, Moving Coil Rectifier Type 0-80Kv Analog Voltmeter Or Trms Digital Voltmeter To Monitor Output Voltage. Nprotection : Electronic Fast Acting Over Current Tripping Device Sensing Ht Current Directly. Nmotorisation : The Unit Will Be Supplied With The Rate Of Rise Of Voltage @ 2Kv / Second And In Case Of Motorization Failure, The Unit Can Be Operated Manually. Naccessories :Acrylic Oil Cup With Electrodes, Gauge, 3 Pin Mains Top. 58 Digital Earth Tester With Kit N4 Terminal Type Ndisplay 3 Digit Lcd Nrange: 10 Ohms & 1000 Ohms Nterminals: 4 Mm Screw Type Nmains Cum Battery Operated

BOQ

Name of Work: ANNEXURE-09: SPECIFICATIONS OF EQUIPMENTS FOR ELECTRICAL ENGG. LAB
Sl.No.Item DescriptionREQUIRED EQUIPMENTQuantityUnits
11Description of Item
21.013 Phase RLC Load 1 KW (Variable) RLC Load consists of following :\n-Resistive Load 1 KW:Loading Rheostat 1.5 KW Three Phase (Each Phase of 0.5 KW) in 4 Steps. 3Phase Loading Rheostats is designed to be used as loads in electrical laboratories. High quality Rheostats are mounted inside the specially designed highly ventilated steel cabinet. Selector switches mounted on bakelite front panel for load selection. Fitted on wheels for easy movement.\nLoading Voltage : 415~440V AC , 50Hz, 3 Phase \nLoading capacity : 1.5 KW Three Phase (0.5 KW each phase) \nNo of steps : 4 (125W each step)\nRheostats : High quality wound with Constantan wire (nickel - copper alloy)\n-Inductive Load 1 KW, 10 Amp, Three Phase\n-Capacitive Load 1 KW, 10 Amp, Three Phaseitem11Nos
32.01RHEOSTAT (100 Ohms / 5 Amp) Range: 100 Ohms / 5 Amps\nSize: 18” x 2 1/4 “ Double Tube\nMaterial Used :\nContact (Double Contact System) - Laminated Phosphorous Bronze,\nEnd bands- Brass Nickled,\nFormer- Porcelain Tube \nGlide Rod- Brass,\nSide Support- Mild Steel\nTerminals- 4 mm Bakelite Embedded with Brass,\nWire- Nichrome Resistance Wire.item21Nos
43.01RHEOSTAT (300 Ohms/ 2 Amp) Range: 300 ohms/2Amps\n24” x 21/4 “ Single Tube\nMaterial Used :\nContact (Double Contact System) - Laminated Phosphorous Bronze,\nEnd bands- Brass Nickled,\nFormer- Porcelain Tube \nGlide Rod- Brass,\nSide Support- Mild Steel\nTerminals- 4 mm Bakelite Embedded with Brass,\nWire- Nichrome Resistance Wire.item31Nos
54.01Work Bench Electrical With Instruments Work bench 5ft x 2.5ft, Height 2.5ft with all metallic structure fitted with wheels with logging arrangements, provided with drawers with lock and key.The work bench is fitted with the following instruments: \na) 3 Phase variac, 28A, 0-470V, \nb) DSO 100Mhz, 2CH\nc) Function Generator 25Mhz, \nd) Dual DC regulated Power supply, 0-30V , 5A\ne) Digital Multimeter suitable to measure AC / DC current, AC/DC Voltage, etc.,\nf) Soldring & De - Soldring Station\ng) Multifunction meter to indicate 3 phase voltage, current, frequency, power factor, power,etc.\nInput Supply 415V , fitted with TPN MCB 32A, Output sockets of 5/15Aitem41Nos
65.01Function Generator Frequency : 0.5 Hz to 5 MHz Function Generators with sine , square, triangle, TTL & DC, 6 digit , Auto ranging 150 MHz Frequency Counter\nAmplitude Modulation (internal & External)\nInternal AM Signal generator 400 Hz/1 kHz\nDistortion factor : < 0.5%\nInternal Lin /Log Sweep and External Frequency Modulation\nCMOS output adjustable from 2 V to 14 V \nBacklit LCD display for modes and frequency\nMicroprocessor based designitem51Nos
76.01Anderson Bridge with inbuilt Digital Null Detector\nIn built fixed DC regulated power supply of ±5V±12V & +5V/ 500mA. \nInbuilt sine wave oscillator, frequency 1KHz ±3%, amplitude 0-15Vpp.\nIn built 3½ digit digital null detector used as detector\nOn Board three set of two decade dial x(10 W & 100W).\nOn Board four unknown inductance & two standard capacitor are mounted behind the front panel with connections are brought out on front panel.\nBakelite used as front panel of 400mm x 225mm & mounted on light weight shock proof plastic cabinet.\nCircuit diagram of discrete component printed & all important connection are brought out on front panel\nPower requirement: 220 VAC +10%, 50Hzitem61Nos
87.01Schering Bridge with inbuilt with Digital Null Detector, Sinewave Oscillator \nIn built fixed DC regulated power supply of ±5V ±12V & +5V/ 500mA.\nInbuilt sine wave oscillator, frequency 1KHz ±3%, amplitude 0-15Vpp.\nIn built 3½ digit digital null detector used as detector\nOn Board two ratio dial “P” & “Q” each having 10 W,100W & 1000W.\nOn Board two decade dial x (0.01 mF & 0.01mF).\nOn Board one variable gang capacitor range of 25pF to 500pF\nOn Board six unknown capacitor are mounted behind the front panel with connections are brought out on front panel.\nBakelite used as front panel of 400mm x 225mm & mounted on light weight shock proof plastic cabinet.\nCircuit diagram of discrete component printed & all important connection are brought out on front panel\nPower requirement : 220 VAC +10%, 50Hzitem71Nos
98.01Kelvin Bridge (Industrial) with DC Source & Galvanometer To measure the low value Resistance.\nMultiplier dial is provided on the front panel with ranges X 0.01W, X0.1W, X1W, X10W, X100W.\nStandard resistance dial & slide wire dial are also provided on the front panel.\nTwo press keys are provided on the front panel marked as coarse and fine.\nCurrent reversing switch is provided on the front panel to get the deflection on left or right\nHand side in a galvanometer.\nTerminals are provided on front panel to connect galvanometer & DC source.item81Nos
109.01Kelvin Bridge (Student) with DC Source & Galvanometer One ratio box of 1-1W, 0. 1-0.1W, 0.01-0.01W, 10-10W, 100-100W, for connection of Galvanometer.\nOne decade dial of X0.01W.\nSlide wire of resistance 0.05W with scale of 100 equal divisions.\nFour terminals for connecting unknown resistance wire.\nTwo terminals are provided for Battery.item91Nos
1110.01Maxwell Inductance Bridge with inbuilt Digital Null detector, Sinewave Oscillator Multiplier dial is provided on the front panel with ranges X 0.01W, X0.1W, X1W, X10W, X100W.\nStandard resistance dial & slide wire dial are also provided on the front panel. Two press keys are provided on the front panel marked as coarse and fine.Current reversing switch is provided on the front panel to get the deflection on left or right, Hand side in a galvanometer.\nTerminals are provided on front panel to connect galvanometer & DC source.\nitem101Nos
1211.01Weins Bridge (Capacity Measurement) with inbuilt Digital Null \nDetector, Sinewave Oscillator \nIn built fixed DC regulated power supply of ±5V , ±12V & +5V/ 500mA. \nInbuilt sine wave oscillator, frequency 1KHz ±3%, amplitude 0-15Vpp.\nIn built 3½ digit digital null detector used as detector\nOn Board two set of two decade dial x(1W & 10W).\nOn Board six unknown capacitor & two capacitor (0.033mF & 1mF) are mounted behind the front panel with connections are brought out on front panel.\nBakelite used as front panel of 400mm x 225mm & mounted on light weight shock proof plastic cabinet.\nCircuit diagram of discrete component printed & all important connection are brought out on front panel.\nPower requirement : 220 VAC +10%, 50Hz \nitem111Nos
1312.01Weins Bridge (Frequency Measurement) with Digital Null Detector with Analog Function Generator 1Hz to 200KHz\nIn built fixed DC regulated power supply of ±5V & +5V/ 500mA.\nIn built 3½ digit digital null detector used as detector\nOn Board two set of two decade dial x(0.01mF& 0.1mF).\nOn Board three decade dial x(10 W , 100W & 1000W).\nOn Board three decade dial x(1W , 10W & 100W).\nBakelite used as front panel of 400mm x 225mm & mounted on light weight shock proof plastic cabinet.\nCircuit diagram of discrete component printed & all important connection are brought out on front panel.\nPower requirement : 220 VAC +10%, 50Hz \nitem121Nos
1413.01Desauty Bridge with inbuilt Digital Null Detector, Sinewave Oscillator \nIn built fixed DC regulated power supply of ±5V, ±12V & +5V/ 500mA. \nInbuilt sine wave oscillator, frequency 1KHz ±3%, amplitude 0-15Vpp.\nIn built 3½ digit digital null detector used as detector\nOn Board two set of two decade dial x(10W & 100W).\nOn Board one decade dial x(0.1mF).\nOn Board six unknown capacitor are mounted behind the front panel with connections are brought out on front panel.\nBakelite used as front panel of 400mm x 225mm & mounted on light weight shock proof plastic cabinet.\nCircuit diagram of discrete component printed & all important connection are brought out on front panel.\nPower requirement : 220 VAC +10%, 50Hzitem131Nos
1514.01Hay's Bridge with inbuilt Digital Null Detector, Sinewave Oscillator In built fixed DC regulated power supply of ±5V, ±12V & +5V/ 500mA.\nInbuilt sine wave oscillator, frequency 1KHz ±3%, amplitude 0-15Vpp.\nIn built 3½ digit digital null detector used as detector\nOn Board two decade dial x(100 W & 1000W).\nOn Board three decade dial x(10W, 100W & 1000W).\nOn Board two decade dial x (0.01mF & 0.1mF).item141Nos
1615.01Owen's Bridge Owen's Bridge with Decade Inductance Box with Sine Wave Oscillator & Decade Inductance Box with Sine Wave Oscillator & Inductance & Sensitive Head Phoneitem151Nos
1716.01IDMT Over Current Relay Testing Kit Relay Type : Over Current Relay IDMT (Electromechanical Induction Disc Type) \nTerminals : 4mm Terminals for Trip, Current Output and Input\nMeters (Digital): 1No. AC Current Meter 0 – 20Amps & 1 No. Digital Timer .0001sec. to 9999sec. (Auto) (96mm x 48 mm)\nCurrent Injector : Inbuilt variable current injector 20Amps to create Phantom Fault Current\nIndicators : Provided on front panel for Mains, Current, Trip and Alarm\nSwitches : Provided on front panel for Mains, Timer Reset, Test Switch (ON/OFF)\nRelay Circuit Diagram : Screen Printed on front panel size 700mm x 400mm\nPower Requirement : 220VAC +10%, 50Hzitem161Nos
1817.01Earth Fault Realy Testing Kit (Electromechanical Type) Relay Type : Earth Fault Relay IDMT (Electromechanical Induction Disc Type) \nTerminals : 4mm Terminals for Trip, Current Output and Input\nMeters (Digital) : 1No. AC Current Meter 0 – 20Amps & 1 No. Digital Timer \n0001sec. to 9999sec. (Auto) (96mm x 48 mm)\nCurrent Injector : Inbuilt variable current injector 20Amps to create Phantom Fault Current\nIndicators : Provided on front panel for Mains, Current, Trip and Alarm, Switches : Provided on front panel for Mains, Timer Reset, Test Switch (ON/OFF)\nRelay Circuit Diagram : Screen Printed on front panel size 700mm x 400mm\nPower Requirement : 220VAC +10%, 50Hzitem171Nos
1918.01Percentage Bias Differential Relay Testing Kit (Electromechanical Type) \nRelay Type : Percentage Biased Differential Relay (Electromechanical Induction Disc Type) \nTerminals : 4mm Terminals for Rheostats to set the biased Current & to vary the Differential Current\nMeters (Digital) : 1No. AC Current Meter 0 – 20Amps, 2Nos. AC Current \nMeters 0 – 50Amps & 1 No. \nDigital Timer .0001sec. to 9999sec. (Auto) (96mm x 48 mm) \nCurrent Injector : Inbuilt variable current injector 20Amps to create \nPhantom Fault Current\nIndicators : Provided on front panel for Mains, Current, Trip and Alarm\nSwitches : Provided on front panel for Mains, Timer Reset, Test Switch \n(ON/OFF)\nRelay Circuit Diagram : Screen Printed on front panel size 700mm x 400mm\nPower Requirement : 220VAC +10%, 50Hz\nitem181Nos
2019.01Transformer Protection using Percentage Biased Diffrential Relay \n(Microprocessor Type) Relay Type : Percentage Biased Diffrential MIB 202 Relay \nTerminals : 4mm Terminals for Rheostats to set the biased Current & to vary the Differential Current\nMeters (Digital) : 2Nos. AC Current Meter 0 – 20Amps, & 1 No. Digital Timer .0001sec. to 9999sec.(Auto) (96mmx48mm) \nCurrent Injector : Inbuilt variable current injector 20Amps to createPhantom Fault Current\nIndicators : Provided on front panel for Mains, Current, Trip and Alarm\nSwitches : Provided on front panel for Mains, Timer Reset, Test Switch (ON/OFF)\nRelay Circuit Diagram : Screen Printed on front panel size 900mm x 600mm\nPower Requirement : 420VAC +10%, 50Hz\n\nitem191Nos
2120.01Thermal Over Load Relay Testing Kit Relay Type : Thermal Relay \nTerminals : 4mm Terminals for Trip, Current Output and Input\nMeters (Digital) : 1No. AC Current Meter 0 – 20Amps & 1 No. Digital Timer \n.0001sec. to 9999sec. (Auto) (96mm x 48 mm)\nCurrent Injector : Inbuilt variable current injector 20Amps to create Phantom Fault Current\nIndicators : Provided on front panel for Mains, Current, Trip and Alarm\nSwitches : Provided on front panel for Mains, Timer Reset, Test Switch \n(ON/OFF)\nRelay Circuit Diagram : Screen Printed on front panel size 700mm x 400mm\nPower Requirement : 220VAC +10%, 50Hzitem201Nos
2221.01Over Voltage Relay Testing Kit (Electromechanical Type) Relay Type : Over Voltage Relay (Electromechanical Induction Disc Type)\nTerminals : 4mm Terminals for Trip, Voltage Output and Input\nMeters (Digital) : 1No. AC Voltmeter Meter 0 – 300V & 1 No. Digital Timer \n.0001sec. to 9999sec. (Auto) (96mm x 48 mm)\nVoltage Injector : Inbuilt variable voltage injector 250V to create Fault Voltage\nIndicators : Provided on front panel for Mains, Voltage, Trip and Alarm\nSwitches : Provided on front panel for Mains, Timer Reset, Test Switch \n(ON/OFF)\nRelay Circuit Diagram : Screen Printed on front panel size 700mm x 400mm \nPower Requirement : 220VAC +10%, 50Hzitem211Nos
2322.01Under Voltage Relay Testing Kit (Electromechanical Type) Relay Type: Under Voltage Relay (Electromechanical Induction Disc Type)\nTerminals: 4mm Terminals for Trip, Voltage Output and Input\nMeters (Digital): 1No. AC Voltmeter Meter 0 – 300V & 1 No. Digital Timer .0001sec. to 9999sec. (Auto) (96mm x 48 mm)\nVoltage Injector : Inbuilt variable voltage injector 250V to create Fault Voltage\nIndicators : Provided on front panel for Mains, Voltage, Trip and Alarm\nSwitches : Provided on front panel for Mains, Timer Reset, Test Switch (ON/OFF)\nRelay Circuit Diagram : Screen Printed on front panel size 700mm x 400mm \nPower Requirement : 220VAC +10%, 50Hz\nitem221Nos
2423.01Over Current Relay (Directional Type) Testing Kit \n(Electromechanical Type) Relay Type : Directional Over Current Relay (Electromechanical Induction Disc Type) \nTerminals : 4mm Terminals for Trip, Current Output and Input\nMeters (Digital) : 1No. AC Current Meter 0 – 20Amps & 1 No. Digital Timer \n.0001sec. to 9999sec. (Auto) (96mm x 48 mm)\nCurrent Injector : Inbuilt variable current injector 20Amps to create Phantom Fault Current\nIndicators : Provided on front panel for Mains, Current, Trip and Alarm\nSwitches : Provided on front panel for Mains, Timer Reset, Test Switch \n(ON/OFF)\nReversing Switch : To reverse the direction of current\nRelay Circuit Diagram : Screen Printed on front panel \nPower Requirement : 220VAC +10%, 50Hz\n\nitem231Nos
2524.01Advance PLC Trainer kit \nRS Logic 1000/ licensed software : Digital & Analog , Digital 16 Input 8 Output , Analog 8 Input 8 Output, Delta Based PLC provided with RS232 Serial port for PC Interfacingitem241Nos
2625.01Simens TIA Module S7-1200/Licensed softwareitem251Nos
2726.01PLC Control panelitem261Nos
2827.01Interfacing Modules for above mentioned PLC Traineritem271Nos
2928.01Module For Traffic Light Controlitem281Nos
3029.01Module For DOL Starter Controlitem291Nos
3130.01Module For Star Delta Starter Controlitem301Nos
3231.01Module For Conveyer Belt Controlitem311Nos
3332.01Module For DC Motor Start,Stop Functionitem321Nos
3433.01Module For Water Level Controlitem331Nos
3534.01Module For Temperature Controlitem341Nos
3635.01Module For Sequence Controlitem351Nos
3736.01Module For Elevator Controlitem361Nos
3837.01Scada Software:- Allean Bradelyitem371Nos
3938.01Scada Software:- wonderware intuch student version :-simensitem381Nos
4039.01Module For Elevator Controlitem391Nos
4140.01Anchor Insulated Copper PVC Cable 2.5 Sq mm Wire(100m)item402Nos
4241.013/20 SWG (PHASE WIRING)(100m)item412Nos
4342.013/22 SWG (NEUTRAL WIRE)(100m)item422Nos
4443.016 Amp. Modular Switch Boarditem435Nos
4544.01TWO WAY SWITCH (10 AMP)item4410Nos
4645.01One Way Modular Switch (10 AMP)item4510Nos
4746.01lamp holdersitem4610Nos
4847.0140w bulb 3 PVC casingitem4710Nos
4948.01MCB (10 AMP)item481Nos
5049.01FUSES (10 AMP)item491Nos
5150.01Magic Power BC-A6 10A Battery Chargeritem501Nos
5251.01BATTERY ELIMINATORitem511Nos
5352.01electrical testing panelitem521Nos
5453.01LUX METER Lux Range: 2000, 20000, 50000Lux \nMax. Resolution: 1Lux\nBasic Accuracy: ±5% FS\nFast Response: 0.2s\nSlow Response: 0.4s\nCosine & Color Corrected, Analog output, Monitor light levels using outputs;\n1mV per count analog output for capturing readings to a recorder, supplied with batteries, light sensor, cable & protective coveritem531Nos
5554.01SMPS Trainer Kit Switched Mode Power Supply (SMPS) using high frequency transformer & high switching transistor has been designed to study the line and load regulation characteristics of SMPS power supplies.\nRotary switch for selections of different input voltage & linearity coil for AC filtrations , Bridge rectifier to convert AC into DC \nDC filtrations circuit is given to filter the impurities i.e. AC components. \nHigh frequency transformer and high frequency transistor (BU 508) for switching action.\nFeed back/ comparator circuit to maintain output voltage constant i.e. +10 % on load. Two meters are provided on the front panel to measure the DC voltage & current. Two bulb holder are mounted on the front panel to connect resistive (Bulb) load across the output. \nBlock diagram printed on front panel & test points brought out on front panel.\nPower requirement: 230 VAC +10%, 50Hz.item541Nos
5655.01UPS TRAINER KIT( 500 VA) • On board controller PCB \n• On board input/output transformer & chargeable battery\n• Digital panel meter for current reading\n• 5 Test points provided on front panel only for observations\n• 5 Fault switch provided on front panel for fault creation\n• LED Indicators for status mode\n• Power Requirement: 220VAC+10%,50Hzitem551Nos
5756.01TRANSFORMER OIL TESTING KIT(0-80KV) Motorized with digital display\nINPUT : 230V AC, Single Phase.\nOUTPUT : 0 –80 KV, center tap earthed,\nCAPACITY : 1 KVA\nINDICATION: Mains ‘ON and ‘HT’ ‘ON’ Indicating Lamps.\nMETERING : 96 sq. mm. Size back of panel mounting, Moving Coil Rectifier type 0-80Kv Analog Voltmeter or TRMS Digital Voltmeter to monitor output voltage.\nPROTECTION : Electronic fast acting over current tripping device sensing HT Current directly.\nMOTORISATION : The unit will be supplied with the rate of rise of voltage @ 2KV/second and in case of motorization failure, the unit can be operated manually.\nACCESSORIES :Acrylic Oil Cup with Electrodes, Gauge, 3 Pin Mains Top.item561Nos
5857.01Digital Earth Tester with Kit \n4 Terminal Type\nDisplay 3 Digit LCD\nRange: 10 Ohms & 1000 Ohms\nTerminals: 4 mm screw type\nMains Cum Battery operateditem571Nos

AI Tender Summary

OUR REF NO 22653188
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 25 Lakhs
LAST DATE 05-12-2019
Authority
Authority Name Department Of Technical Education
Work Description E-Tender For Procurement Of Equipments Of Civil, Mechanical , Electrical Engineering And Basic Science Labs Of Raisen And Lateri Polytechnic Institutes - 2 3 Phase Rlc Load 1 Kw ( Variable ) Rlc Load Consists Of Following : N-Resistive Load 1 Kw:Loading Rheostat 1.5 Kw Three Phase ( Each Phase Of 0.5 Kw ) In 4 Steps. 3Phase Loading Rheostats Is Designed To Be Used As Loads In Electrical Laboratories. High Quality Rheostats Are Mounted Inside The Specially Designed Highly Ventilated Steel Cabinet. Selector Switches Mounted On Bakelite Front Panel For Load Selection. Fitted On Wheels For Easy Movement. Nloading Voltage : 415~440V Ac , 50Hz, 3 Phase Nloading Capacity : 1.5 Kw Three Phase ( 0.5 Kw Each Phase ) Nno Of Steps : 4 ( 125W Each Step ) Nrheostats : High Quality Wound With Constantan Wire ( Nickel - Copper Alloy ) N-Inductive Load 1 Kw, 10 Amp, Three Phase N-Capacitive Load 1 Kw, 10 Amp, Three Phase 3 Rheostat ( 100 Ohms / 5 Amp ) Range: 100 Ohms / 5 Amps Nsize: 18” X 2 1 / 4 “ Double Tube Nmaterial Used : Ncontact ( Double Contact System ) - Laminated Phosphorous Bronze, Nend Bands- Brass Nickled, Nformer- Porcelain Tube Nglide Rod- Brass, Nside Support- Mild Steel Nterminals- 4 Mm Bakelite Embedded With Brass, Nwire- Nichrome Resistance Wire. 4 Rheostat ( 300 Ohms / 2 Amp ) Range: 300 Ohms / 2Amps N24” X 21 / 4 “ Single Tube Nmaterial Used : Ncontact ( Double Contact System ) - Laminated Phosphorous Bronze, Nend Bands- Brass Nickled, Nformer- Porcelain Tube Nglide Rod- Brass, Nside Support- Mild Steel Nterminals- 4 Mm Bakelite Embedded With Brass, Nwire- Nichrome Resistance Wire. 5 Work Bench Electrical With Instruments Work Bench 5Ft X 2.5Ft, Height 2.5Ft With All Metallic Structure Fitted With Wheels With Logging Arrangements, Provided With Drawers With Lock And Key.The Work Bench Is Fitted With The Following Instruments: Na ) 3 Phase Variac, 28A, 0-470V, Nb ) Dso 100Mhz, 2Ch Nc ) Function Generator 25Mhz, Nd ) Dual Dc Regulated Power Supply, 0-30V , 5A Ne ) Digital Multimeter Suitable To Measure Ac / Dc Current, Ac / Dc Voltage, Etc., Nf ) Soldring & De - Soldring Station Ng ) Multifunction Meter To Indicate 3 Phase Voltage, Current, Frequency, Power Factor, Power, Etc. Ninput Supply 415V , Fitted With Tpn Mcb 32A, Output Sockets Of 5 / 15A 6 Function Generator Frequency : 0.5 Hz To 5 Mhz Function Generators With Sine , Square, Triangle, Ttl & Dc, 6 Digit , Auto Ranging 150 Mhz Frequency Counter Namplitude Modulation ( Internal & External ) Ninternal Am Signal Generator 400 Hz / 1 Khz Ndistortion Factor : < 0.5% Ninternal Lin / Log Sweep And External Frequency Modulation Ncmos Output Adjustable From 2 V To 14 V Nbacklit Lcd Display For Modes And Frequency Nmicroprocessor Based Design 7 Anderson Bridge With Inbuilt Digital Null Detector Nin Built Fixed Dc Regulated Power Supply Of ±5V±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Three Set Of Two Decade Dial X ( 10 W & 100W ) . Non Board Four Unknown Inductance & Two Standard Capacitor Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel Npower Requirement: 220 Vac +10%, 50Hz 8 Schering Bridge With Inbuilt With Digital Null Detector, Sinewave Oscillator Nin Built Fixed Dc Regulated Power Supply Of ±5V ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Ratio Dial “P” & “Q” Each Having 10 W, 100W & 1000W. Non Board Two Decade Dial X ( 0.01 Mf & 0.01Mf ) . Non Board One Variable Gang Capacitor Range Of 25Pf To 500Pf Non Board Six Unknown Capacitor Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel Npower Requirement : 220 Vac +10%, 50Hz 9 Kelvin Bridge ( Industrial ) With Dc Source & Galvanometer To Measure The Low Value Resistance. Nmultiplier Dial Is Provided On The Front Panel With Ranges X 0.01W, X0.1W, X1w, X10w, X100w. Nstandard Resistance Dial & Slide Wire Dial Are Also Provided On The Front Panel. Ntwo Press Keys Are Provided On The Front Panel Marked As Coarse And Fine. Ncurrent Reversing Switch Is Provided On The Front Panel To Get The Deflection On Left Or Right Nhand Side In A Galvanometer. Nterminals Are Provided On Front Panel To Connect Galvanometer & Dc Source. 10 Kelvin Bridge ( Student ) With Dc Source & Galvanometer One Ratio Box Of 1-1W, 0. 1-0.1W, 0.01-0.01W, 10-10W, 100-100W, For Connection Of Galvanometer. None Decade Dial Of X0.01W. Nslide Wire Of Resistance 0.05W With Scale Of 100 Equal Divisions. Nfour Terminals For Connecting Unknown Resistance Wire. Ntwo Terminals Are Provided For Battery. 11 Maxwell Inductance Bridge With Inbuilt Digital Null Detector, Sinewave Oscillator Multiplier Dial Is Provided On The Front Panel With Ranges X 0.01W, X0.1W, X1w, X10w, X100w. Nstandard Resistance Dial & Slide Wire Dial Are Also Provided On The Front Panel. Two Press Keys Are Provided On The Front Panel Marked As Coarse And Fine.Current Reversing Switch Is Provided On The Front Panel To Get The Deflection On Left Or Right, Hand Side In A Galvanometer. Nterminals Are Provided On Front Panel To Connect Galvanometer & Dc Source. N 12 Weins Bridge ( Capacity Measurement ) With Inbuilt Digital Null Ndetector, Sinewave Oscillator Nin Built Fixed Dc Regulated Power Supply Of ±5V , ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Set Of Two Decade Dial X ( 1W & 10W ) . Non Board Six Unknown Capacitor & Two Capacitor ( 0.033Mf & 1Mf ) Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel. Npower Requirement : 220 Vac +10%, 50Hz N 13 Weins Bridge ( Frequency Measurement ) With Digital Null Detector With Analog Function Generator 1Hz To 200Khz Nin Built Fixed Dc Regulated Power Supply Of ±5V & +5V / 500Ma. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Set Of Two Decade Dial X ( 0.01Mf& 0.1Mf ) . Non Board Three Decade Dial X ( 10 W , 100W & 1000W ) . Non Board Three Decade Dial X ( 1W , 10W & 100W ) . Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel. Npower Requirement : 220 Vac +10%, 50Hz N 14 Desauty Bridge With Inbuilt Digital Null Detector, Sinewave Oscillator Nin Built Fixed Dc Regulated Power Supply Of ±5V, ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Set Of Two Decade Dial X ( 10W & 100W ) . Non Board One Decade Dial X ( 0.1Mf ) . Non Board Six Unknown Capacitor Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel. Npower Requirement : 220 Vac +10%, 50Hz 15 Hays Bridge With Inbuilt Digital Null Detector, Sinewave Oscillator In Built Fixed Dc Regulated Power Supply Of ±5V, ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Decade Dial X ( 100 W & 1000W ) . Non Board Three Decade Dial X ( 10W, 100W & 1000W ) . Non Board Two Decade Dial X ( 0.01Mf & 0.1Mf ) . 16 Owens Bridge Owens Bridge With Decade Inductance Box With Sine Wave Oscillator & Decade Inductance Box With Sine Wave Oscillator & Inductance & Sensitive Head Phone 17 Idmt Over Current Relay Testing Kit Relay Type : Over Current Relay Idmt ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 18 Earth Fault Realy Testing Kit ( Electromechanical Type ) Relay Type : Earth Fault Relay Idmt ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer N0001sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm, Switches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 19 Percentage Bias Differential Relay Testing Kit ( Electromechanical Type ) Nrelay Type : Percentage Biased Differential Relay ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Rheostats To Set The Biased Current & To Vary The Differential Current Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps, 2Nos. Ac Current Nmeters 0 – 50Amps & 1 No. Ndigital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Nphantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz N 20 Transformer Protection Using Percentage Biased Diffrential Relay N ( Microprocessor Type ) Relay Type : Percentage Biased Diffrential Mib 202 Relay Nterminals : 4Mm Terminals For Rheostats To Set The Biased Current & To Vary The Differential Current Nmeters ( Digital ) : 2Nos. Ac Current Meter 0 – 20Amps, & 1 No. Digital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mmx48mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Createphantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 900Mm X 600Mm Npower Requirement : 420Vac +10%, 50Hz N N 21 Thermal Over Load Relay Testing Kit Relay Type : Thermal Relay Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer N.0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 22 Over Voltage Relay Testing Kit ( Electromechanical Type ) Relay Type : Over Voltage Relay ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Voltage Output And Input Nmeters ( Digital ) : 1No. Ac Voltmeter Meter 0 – 300V & 1 No. Digital Timer N.0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Nvoltage Injector : Inbuilt Variable Voltage Injector 250V To Create Fault Voltage Nindicators : Provided On Front Panel For Mains, Voltage, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 23 Under Voltage Relay Testing Kit ( Electromechanical Type ) Relay Type: Under Voltage Relay ( Electromechanical Induction Disc Type ) Nterminals: 4Mm Terminals For Trip, Voltage Output And Input Nmeters ( Digital ) : 1No. Ac Voltmeter Meter 0 – 300V & 1 No. Digital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Nvoltage Injector : Inbuilt Variable Voltage Injector 250V To Create Fault Voltage Nindicators : Provided On Front Panel For Mains, Voltage, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz N 24 Over Current Relay ( Directional Type ) Testing Kit N ( Electromechanical Type ) Relay Type : Directional Over Current Relay ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer N.0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nreversing Switch : To Reverse The Direction Of Current Nrelay Circuit Diagram : Screen Printed On Front Panel Npower Requirement : 220Vac +10%, 50Hz N N 25 Advance Plc Trainer Kit Nrs Logic 1000 / Licensed Software : Digital & Analog , Digital 16 Input 8 Output , Analog 8 Input 8 Output, Delta Based Plc Provided With Rs232 Serial Port For Pc Interfacing 26 Simens Tia Module S7-1200 / Licensed Software 27 Plc Control Panel 28 Interfacing Modules For Above Mentioned Plc Trainer 29 Module For Traffic Light Control 30 Module For Dol Starter Control 31 Module For Star Delta Starter Control 32 Module For Conveyer Belt Control 33 Module For Dc Motor Start, Stop Function 34 Module For Water Level Control 35 Module For Temperature Control 36 Module For Sequence Control 37 Module For Elevator Control 38 Scada Software:- Allean Bradely 39 Scada Software:- Wonderware Intuch Student Version :-Simens 40 Module For Elevator Control 41 Anchor Insulated Copper Pvc Cable 2.5 Sq Mm Wire ( 100M ) 42 3 / 20 Swg ( Phase Wiring ) ( 100M ) 43 3 / 22 Swg ( Neutral Wire ) ( 100M ) 44 6 Amp. Modular Switch Board 45 Two Way Switch ( 10 Amp ) 46 One Way Modular Switch ( 10 Amp ) 47 Lamp Holders 48 40W Bulb 3 Pvc Casing 49 Mcb ( 10 Amp ) 50 Fuses ( 10 Amp ) 51 Magic Power Bc-A6 10A Battery Charger 52 Battery Eliminator 53 Electrical Testing Panel 54 Lux Meter Lux Range: 2000, 20000, 50000Lux Nmax. Resolution: 1Lux Nbasic Accuracy: ±5% Fs Nfast Response: 0.2S Nslow Response: 0.4S Ncosine & Color Corrected, Analog Output, Monitor Light Levels Using Outputs; N1mv Per Count Analog Output For Capturing Readings To A Recorder, Supplied With Batteries, Light Sensor, Cable & Protective Cover 55 Smps Trainer Kit Switched Mode Power Supply ( Smps ) Using High Frequency Transformer & High Switching Transistor Has Been Designed To Study The Line And Load Regulation Characteristics Of Smps Power Supplies. Nrotary Switch For Selections Of Different Input Voltage & Linearity Coil For Ac Filtrations , Bridge Rectifier To Convert Ac Into Dc Ndc Filtrations Circuit Is Given To Filter The Impurities I.E. Ac Components. Nhigh Frequency Transformer And High Frequency Transistor ( Bu 508 ) For Switching Action. Nfeed Back / Comparator Circuit To Maintain Output Voltage Constant I.E. +10 % On Load. Two Meters Are Provided On The Front Panel To Measure The Dc Voltage & Current. Two Bulb Holder Are Mounted On The Front Panel To Connect Resistive ( Bulb ) Load Across The Output. Nblock Diagram Printed On Front Panel & Test Points Brought Out On Front Panel. Npower Requirement: 230 Vac +10%, 50Hz. 56 Ups Trainer Kit ( 500 Va ) • On Board Controller Pcb N• On Board Input / Output Transformer & Chargeable Battery N• Digital Panel Meter For Current Reading N• 5 Test Points Provided On Front Panel Only For Observations N• 5 Fault Switch Provided On Front Panel For Fault Creation N• Led Indicators For Status Mode N• Power Requirement: 220Vac+10%, 50Hz 57 Transformer Oil Testing Kit ( 0-80Kv ) Motorized With Digital Display Ninput : 230V Ac, Single Phase. Noutput : 0 –80 Kv, Center Tap Earthed, Ncapacity : 1 Kva Nindication: Mains ‘On And ‘Ht’ ‘On’ Indicating Lamps. Nmetering : 96 Sq. Mm. Size Back Of Panel Mounting, Moving Coil Rectifier Type 0-80Kv Analog Voltmeter Or Trms Digital Voltmeter To Monitor Output Voltage. Nprotection : Electronic Fast Acting Over Current Tripping Device Sensing Ht Current Directly. Nmotorisation : The Unit Will Be Supplied With The Rate Of Rise Of Voltage @ 2Kv / Second And In Case Of Motorization Failure, The Unit Can Be Operated Manually. Naccessories :Acrylic Oil Cup With Electrodes, Gauge, 3 Pin Mains Top. 58 Digital Earth Tester With Kit N4 Terminal Type Ndisplay 3 Digit Lcd Nrange: 10 Ohms & 1000 Ohms Nterminals: 4 Mm Screw Type Nmains Cum Battery Operated
Basic Detail
Tender No STORE/2019-20/ 2176/1
Bidding Type Tender
Location
City Raisen and Lateri
State Madhya Pradesh
Key Dates
Publish Date 26 Nov 2019
Submission Date 05 Dec 2019
Open Date 07 Dec 2019
Finance
Tender Value 25 Lakhs
Tender Fee 2000
EMD 75000
Exemption Not Available
Document List
1416CADB-DD51-431A-A3AA-B3F94BABFD4D.html
Annexure9.pdf
Tendernotice_1.pdf
Corrigendua_1.pdf
BOQ_73968.xls
GWP_EQUIP_FINAL.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 26, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 07, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

1416CADB-DD51-431A-A3AA-B3F94BABFD4D.html

pdf

Annexure9.pdf

pdf

Tendernotice_1.pdf

pdf

Corrigendua_1.pdf

xls

BOQ_73968.xls

pdf

GWP_EQUIP_FINAL.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders