}

Providing Supply Of Instrument, Chemical, Glasware, Manikins For Skill Lab And Computer & Printer (Part 2)-Gujarat

Health And Family Welfare Department has published Providing Supply Of Instrument, Chemical, Glasware, Manikins For Skill Lab And Computer & Printer (Part 2). Submission Date for this Tender is 17-12-2019. Coats and Jackets Tenders in Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

22646441
Providing Supply Of Instrument, Chemical, Glasware, Manikins For Skill Lab And Computer & Printer (Part 2)
Tender
Indian
Gujarat
17-12-2019

Tender Details

Providing Supply Of Instrument, Chemical, Glasware, Manikins For Skill Lab And Computer & Printer (Part 2) 573. Orthopedicsmovie Camera For Demonstration Of Live Operations 574. Plaster Tables 575. Electric Plaster Cutter 576. Basic Instrumentation Set For Fracture. 577. External Fixator 578. C-Arm (Image Intensifier) 579. Portable X-Ray Machine 580. Slide Projector 581. Over-Head Projector 582. Operation Room Equipment (Sets) 583. Anesthesiologypatient Examination Table - Specification Overall Approx Size: 187 L X 51 W X 81 H. Cms.Adjustable Backrest.Two Section Foam Padded.Provided With Three Drawers.Powder Coated. 584. Blood Pressure Instrument - (Non-Invasive)- Oscillometric. , Digital Display , Systolic Bp. , Diastolic Bp. , Mean Bp. , Selectable Manual/ Automatic Mode. , Extar Large Cuff. , Adult Cuff , Pediatric Cuff. , Neonate Cuff. , Cable. 585. Height Measurement Scale Measuring Range: 20 - 205 Cm,Graduation: 1 Mm. ,Stable. , Easy To Fix. 586. Weighing Machine Spring Type, Non Digital, Easy To Calibrate, Range Of 10- Kg To 150 Kg 587. Multiparameter Monitors With Capnography(1) Conforming To International Standards Us Fda And Ce. Certificates To Be Attached . [Critical](2) Is0-13485- Medical Devices- - Quality Management Systems-- Requirements For Regulatory Purposes. It Specifies Requirements For A Quality Management System Where An Organization Needs To Demonstrate Its Ability To Provide Medical Devices And Related Services That Consistently Meet Customer Requirements And Regulatory Requirements Applicable To Medical Devices And Related Services . Certificates To Be Attached. [Critical] (3) Iec Safety Standard Certified . To Be Attached. [Critical](4) Portable. [Critical](5) Six Channel [Critical](6) High Resolution Colour Tft Display With 12Or More Screen Size . [Critical](7) Should Work On Mains As Well As Battery (Backup- 4-8 Hrs) [Critical](8) Should Be Able To Monitor [Critical] Ecg , Sp02- Waveform And Numerics, Capnography- Waveform And Numerics, Nibp, Temperature, Respiration,(9) Should Be Able To Monitor These Parameters In Adult, Paediatric And Neonatal Patients. [Critical](10) Ecg Monitoring: [Critical] 3 Ecg Leads Permit Display Of Lead I, Ii, Ill. , 5 Ecg Leads Permit Display Of Lead I, Ii, Ill, Avr, Avl, Avf, Cascade Waveform Facility, St Segment Analysis Should Be Possible For One Lead, Arrhythmia Detection, Defibrillator And Cautery Protection Should Be Provided [Critical], Heart Rate : 20-300 Bpm, Sweep Speed- 12.5 Mm/S; 25 Mm/Sec; 50 Mm/ Sec .(11) Pulse Oximetr [Critical] Display Of Plethysmograph, Display Of Perfusion Level Indicator, Display Of Sp02 Values, Sp02 Range 40-100%, Pitch Variation With Change In Oxygen Saturation, Pulse Rate Range 30-200 Bpm, Accuracy To Be Mentioned, Type Of Probe: Nelcor Original Or Masimo Original (Pl. Specify) (With Certificate Issued By Principal Manufacturer Of The Probe For The Quoted Model ), (12) Capnography : [Critical] Waveform Display, Digital Display For Etc02, Fic02 & Rr, Should Be Micro Stream Technology (Which Is A Variant Of Side Stream Type), Flow Rate Requirement Should Be Appro X Imate 50 -60 Ml Per Minute (Flow Range To Be Mentioned ), Etc02 Range Should Be 0-100 Mm Of Hg, Fico2 Range Should Be 0-20 Mm Of Hg, Carbon Dioxide Values In Mm Of Hg, Torr, Kpa Units(13) Non Invasive Blood Pressure {Nibp) [Critical] Oscillometric Method For Adult,Child& Neonate, Measurement And Display Of Systolic, Diastolic And Mean Pressure Values Of Nibp Measurement, Range 30-220 Mm Of Hg, User Selectable Alarm Settings, 3 Modes Of Operation: Manual, Stat (Continuous Sminute Operation) , Automatic (Selectable Time Interval 2- 90Minutes), Accuracy To Be Mentioned(14) Temqerature Monitoring: [Critical] Dual, Units (Degree C And Degree F) Selectable, Display Oftl, T2,And Differential Temperature Should Be User Selectable, Temp . Range 0-50 Deg. C, Probes Should Be Ysi Series, Reusable Skin Temperature Probe Should Be Available, Reusable Nasopharyngeal Te 588. Ultrasound Machine(1) Latest Technology All - Digital Hand Held Colour Doppler System Suitable For Central And Peripheral Line Placements, Epidurals, Pain Management, Nerve Blocks And Tran Esophageal Echocardiography Scanning Applications.(2) The Unit Should Be Compact, Lightweight And Portable. Specify Weight And Dimensions. Weight Should Not Exceed 3.5 Kg Excluding Cart And Accessories.(3) Should Have Broad Band Frequency Transducer Technology. (4) Should Have B Mode, M-Mode, Colour, Angio, Pulsed Wave Doppler Mode And Continuous Wave Doppler Mode Of Imaging. (5) Should Have Tissue Harmonic Imaging Facility.(6) Should Have Fast Boot Up Less Than 30 Seconds For Critical Situation.(7) System With Inbuilt Rechargeable Battery Will Be Preferred And Longer Battery Life. Should Have Ac Mains Adaptor / Battery Charger.(8) It Should Have Inbuilt Foldable Alphanumeric Keyboard, Can Be Sanitize To Tack In To Ot. (9) Flat Lcd/ Tft Monitor Of At Least 10 Inches(10) Should Onboard Storage Of At Least 10000 Images. Storage In Bmp And Avi Format Should Be Possible. Sorting Of Database With Patient Name And Date Should Be Possible. And Have Facility To Transfer Images To Computer.(11) Should Have Cine Memory And Clip Storage Facility.(12) Should Dicom Ready System(13) Video In/Out, Vcr Or Dvd For Record Possible, B/W Thermal Printer, Output To External Display. (14) 13-6 Mhz Broad Band Linear Probe For Vascular Access, Vascular Imaging, Small Parts, Regional Nerve Blocks(15) The Price Must Be Quoted For Unit And Transducers Covered With Comprehensive Onsite Warranty For Five Years. 589. White Screen For Lcd Projectionsize: 4 X 5 Fit. Good Quality:With Stand 590. Pulmonary Function Test (Pft ) Machine

Key Value

Document Fees
INR 15000 /-
EMD
INR 100000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail