| 1 | 1.01 | Supply of elevated type LED Taxiway Edge light fitting (MIRL fitting) for use as Taxiway / Apron Edge /Turning Pad lights suitable for operation at 2.8 Amps to 6.6 Amps series circuit supply current complete with minimum 1 watt LED, Omni-directional Blue lens (glass), Lens clamping mechanism, breakable coupling, rings /gaskets, base plate with 06 nos. M-10 stainless steel bolts and including an integrated encapsulated suitable electronic converter with standard secondary lead etc. complete fitting confirming to latest ICAO standards /requirement as required. | item1 | 28 | Nos |
|---|
| 2 | 1.02 | Supply of following rating 5000V, 50 Hz individual lamp series type Isolating Transformer suitable for above installation encapsulated in polyester resin & finally moulded in neoprene rubber with primary and secondary connection leads complete and confirming to tenders technical specifications, terms & conditions etc. complete as required. | | | |
|---|
| 3 | 1.03 | (a) 150 Watt,6.6A/6.6A | item2 | 28 | Nos |
|---|
| 4 | 1.04 | Supply of following rating 5000V, 50 Hz individual lamp series type Isolating Transformer suitable for above installation encapsulated in polyester resin & finally moulded in neoprene rubber with primary and secondary connection leads complete and confirming to tenders technical specifications, terms & conditions etc. complete as required. | | | |
|---|
| 5 | 1.05 | (b) 200 Watt , 6.6 A/6.6 A | item3 | 20 | Nos |
|---|
| 6 | 1.06 | Supply of C.I. isolating transformer housing box, water tight round type, metal container of outside size 330 mm height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick, cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformer power cable and having a clear hole at two side surface centre 75 mm above bottom surface suitable to receive of 50 mm dia (outer dia) HDPE/G. I. pipe and including check nuts as required and another hole at 175 mm from the bottom of the CI box to receive one no. 15 mm dia, \"B\" class, GI pipe and check nut as required. The box should have two SS earth bolts of M10 x 30 mm tapped inside near the hole away from the hole centre and having a drain hole at the bottom suitably tapped to receive 15 mm dia, \"B\" class GI pipe and having clear opening of 220 mm at the top surface and 6 nos. M10 tapped hole at the hole centre 260 mm to receive fitting base plate and bolts and confirming to tenders technical specifications, terms & conditions etc. complete as required. | | | |
|---|
| 7 | 1.07 | (a) Single Hole Type | item4 | 28 | each |
|---|
| 8 | 1.08 | Design, Supply, Installation, Testing and Commissioning of FAA compliant, indoor type Microprocessor based Constant Current regulator (CCR) suitable for remote as well as local control operations with 5 position brightness control (6.6A maximum current corresponding to 100% brightness) on input voltage 230/415V, 50 Hz., AC supply, provision for control supply with all switchgears, CCR protections, connection/inter-connections etc. and confirming to tenders technical specifications, terms & conditions etc. complete as required. | | | |
|---|
| 9 | 1.09 | (a) 4 Kw, 6.6A output current. | item5 | 1 | Nos |
|---|
| 10 | 1.1 | Installation of elevated light fixture on existing transformer housing box with all required accessories & isolating transformer i/c alignment, levelling, setting of fixture, connection/inter-connection with isolating transformer & fixture as per site i/c testing & commissioning complete as per required and confirming to tenders technical specifications, terms & conditions etc. complete as required. | item6 | 28 | JOB |
|---|
| 11 | 1.11 | Supply of 5 kV grade ESNA connector and suitable for field attachment with 5kV grade PVC insulated, PVC sheathed single core 6 sq. mm copper conductor cable conforming to technical specifications etc. complete as required. | item7 | 80 | each |
|---|
| 12 | 1.12 | Extra for core cutting in existing PCC of required depth and size suitable for light fittings with core cutting machine complete as required and confirming to tenders technical specifications, terms & conditions etc. complete as required. | item8 | 28 | JOB |
|---|
| 13 | 1.13 | Providing, laying and fixing 40 mm dia \"B\" class G.I. pipe with G.I. fittings including alignment of GI pipe with the existing Housing box and fitting, after cutting the Taxiway/Apron upto 300 mm depth and minimum width suitable for laying pipe of size upto 50mm dia with the help of suitable cutting machine and mechanical means and disposal of debris upto 300 mtr and also making good the surface after pipe is laid, by providing and laying in position concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) etc. for concrete surface and ready mix bitumen/ road bond for bituminous surface etc. complete as required. | item9 | 130 | Metre |
|---|
| 14 | 1.14 | Making connections of 5 kV grade, 6 sq. mm copper conductor AFL cables with ESNA connector i/c crimping & fixing, applying HT tape complete as required. | item10 | 60 | each |
|---|
| 15 | 1.15 | Installation of transformer housing boxes with a base concrete of 1:3:6 of size 630 x 630 x 100 mm thick all round concrete of 1:2:4, 150 mm thick, the top sloped with 1:2:4 cement including providing and fixing 250 mm long 15 dia \"B\" Class GI pipe with check nut for drainage of water including excavation of side shoulder and refilling etc complete as required. | item11 | 28 | JOB |
|---|
| 16 | 1.16 | Earting with GI earth pipe of 4.5 m long and 40 mm dia, including accessories and providing masonry enclosure with cover plate on the top having locking arrangement and watering pipe, complete with charcoal and salt etc. as required. | item12 | 2 | each |
|---|
| 17 | 1.17 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | item13 | 130 | Metre |
|---|
| 18 | 1.18 | Providing & fixing 6 SWG GI wire along with cable in soil for loop earthing | item14 | 1350 | Metre |
|---|
| 19 | 1.19 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 5 kV grade upto 16 sq. mm size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. | item15 | 1350 | Metre |
|---|
| 20 | 1.2 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 5 kV grade upto 16 sq. mm size in the existing RCC/GI/HUME/METAL pipe etc. as required. | item16 | 130 | Metre |
|---|
| 21 | 1.21 | Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 5 kV grade upto 16 sq. mm size in the existing masonry open duct as required. | item17 | 30 | Metre |
|---|