| 1 | 1 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | | 600 | sqm |
|---|
| 2 | 2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | | 600 | sqm |
|---|
| 3 | 3 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :\nNew work (two or more coats) over and including water thinnable priming coat with cement primer | | 400 | sqm |
|---|
| 4 | 4 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.\nSize of Tile 600x600 mm | | 40 | sqm |
|---|
| 5 | 5 | Finishing walls with Acrylic Smooth exterior paint of required shade :\nNew work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | | 200 | sqm |
|---|
| 6 | 6 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :\nOne or more coats on old work | | 300 | sqm |
|---|
| 7 | 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :\nCement mortar 1:4 (1 cement : 4 coarse sand) | | 20 | cum |
|---|
| 8 | 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :\n1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). | | 2 | cum |
|---|
| 9 | 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.\nThermo-Mechanically Treated bars of grade Fe-500D or more. | | 400 | Kg |
|---|
| 10 | 10 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3\ncoarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | | 70 | sqm |
|---|
| 11 | 11 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :\nSuspended floors, roofs, landings, balconies and access platform | | 20 | sqm |
|---|
| 12 | 12 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge.\nWith cement mortar 1:4 (1cement: 4 coarse sand) | | 50 | sqm |
|---|
| 13 | 13 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.\nIn cement mortar | | 20 | cum |
|---|
| 14 | 14 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | | 50 | sqm |
|---|
| 15 | 15 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.\nHot finished welded type tubes | | 50 | kg |
|---|
| 16 | 16 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. | | 100 | cum |
|---|
| 17 | 17 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :\n\"1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). | | 2 | cum |
|---|
| 18 | 18 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin- charge. | | 51 | sqm |
|---|
| 19 | 19 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :\nInside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :\nWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | | 1 | each |
|---|
| 20 | 20 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :\nAll kinds of soil\nPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia | | 15 | metre |
|---|
| 21 | 21 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :\nFor pipes 100 to 250 mm diameter | | 1 | each |
|---|
| 22 | 22 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :\n150 mm dia. R.C.C. pipe | | 15 | metre |
|---|
| 23 | 23 | Providing and fixing factory made Fiberglass Reinforced plastics (F.R.P.) chajja 4 mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 nos vertically and 1 nos horizontally 50x2 mm thick M.S. flat with 12 mm in built hole for grouting on the existing wall along with the 50 mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically, including all necessary fittings . The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746, duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather & sunlight. | | 30 | sqm |
|---|
| 24 | 24 | Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat:\nWith common burnt clay F.P.S. (non modular) brick tiles of class designation 10 | | 150 | sqm |
|---|
| 25 | 25 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. | | 15 | cum |
|---|
| 26 | 26 | Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 Kg per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). | | 150 | sqm |
|---|
| 27 | 27 | Repair to damaged/dismentled beam/slab by plastering with 20mm thick cement concrete in the ratio 1:1:2(1 cement : 1 coarse sand : 2 stone aggregate 6mm and down size) after fixing hard drawn steel wire fibric 75x25mm weight not less than 7.75kg per sqr mtr by means of binding wire with exposed reinforcement complete including finishing with 6mm cement plaster of mix 1:3 (1 cement 3 fine sand), cost of scafolding etc complete all as per direction of Engineer-in-charge. | | 100 | sqm |
|---|
| 28 | 28 | Providing and fixing pre-polished precast concrete designer tiles 10mm thick extra heavy duty of approved brand and manufacturer (Ultra tile/omaxe or equivalent) of required shape & size over a bed of average thickness of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) laying and jointing with cement slurry @ 3.3. kg per sqm including pointing the joints with ready mixed pointing material complete in all respect as per directions of Engineer-in-charge. | | 200 | Sqm. |
|---|