Military Engineer Services-MES has published Special Repair To Replace The Old Pattern Meters With Smart Prepaid In Mil Stn Patiala Under Ge North Patiala Special Repair To Replace The Old Pattern Meters With Smart Prepaid In Mil Stn Patiala Under Ge North Patiala. Submission Date for this Tender is 10-12-2019. Water Meters Tenders in Patiala Mil Stn Punjab. Bidders can get complete Tender details and download the document.
Name of Work: SPECIAL REPAIR TO REPLACE THE OLD PATTERN METERS WITH SMART PREPAID IN MIL STN PATIALA UNDER GE NORTH PATIALA | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down old type/defective electric energy meters of Single/Three phase and deposited the same in MES store yard complete all as specified and directed. | BI01010001010000000000000515BI0100001113 | 127 | Each Job |
2 | 2 | Supply and fix in replacement LT 3 Phase, 4 W direct connected prepaid key pad based BIS Marked IS-15884 Digital Energy Meter, 10-60 Amps, Accuracy class-1.0 alongwith parallel Consumer Interface Unit and Soft Token Transfer Device (STTD) with 3 pair, 0.5mm copper anealed wire of suitable length on suitable batten/High grade pipe between prepaid meter and STTD at houses, with Poly Carbonate meter box with facility of meter reading and Monthly Authenticated Billing Code ( ABC) facility for Generating Monthly Energy usage Bills, having LCD type display, calliberation LED, numeric key pad for token entry with RS 232 communication port, LED for credit status indication, push button for scroll and having features for load disconnection in case the credit limit become zero or increase of load than permissible limit, reconnection and disconnection of load, buzzer at Consumer Interface Unit to give alarm in case of low credit and overloading and data download port for last 25 days (min) temper event and load survey for last 45 days with all standard anti temper features including sealing facility all as specified and directed.\nNote : The Energy Meter must be having facility to generate Authenticated Billing Code ( ABC) for monthly bill generation and on line recharge through 'Enroid Mobile APP' facility. \nMake : L&T / HPL / Havells ABB / Siemens | BI01010001010000000000000515BI0100001114 | 6 | Each Set |
3 | 3 | Supply and fix in replacement LT Single Phase -2W direct connected prepaid key pad based BIS Marked IS-15884 Digital Energy Meter, 10-60 Amps, 240 Volts, accuracy class-1.0 alongwith parallel Consumer Interface Unit and Soft Token Transfer Device (STTD) with 3 pair, 0.5mm copper anealed wire of suitable length on suitable batten/High grade pipe between prepaid meter and STTD at houses, with Poly Carbonate meter box with facility of meter reading and Monthly Authenticated Billing Code ( ABC) facility for Generating Monthly Energy usage Bills , having LCD type display, calliberation LED, numeric key pad for token entry with RS 232 communication port, LED for credit status indication, push button for scroll and having features for load disconnection in case the credit limit become zero or increase of load than permissible limit, reconnection and disconnection of load, buzzer at Consumer Interface Unit to give alarm in case of low credit and overloading and data download port for last 25 days (min) temper event and load survey for last 45 days with all standard anti temper features including sealing facility all as specified and directed. \nNote : The Energy Meter must be having facility to generate Authenticated Billing Code ( ABC) for monthly bill generation and on line recharge through 'Enroid Mobile APP' facility. \nMake : HPL / ABB / Siemens / L&T / Havells | BI01010001010000000000000515BI0100001115 | 121 | Each Set |
4 | 4 | Supply of computer PC with Core i5 processor second generation, 8 GB RAM, Hard disk 500 GB, 1-CD/DVD combo drive RW type 4-USB port, 1-serial port 9 Pin D type, TFT (17") monitor and impact token printer with licensed operating system (Window 2007)/2008) and UPS system with 12 Volt maint free battery and connecting cable pair etc. to transfer the credit token on STTD including necessary software required for vending station to prepare the consumer data base Tariff creation, setting of load limit and to generate the credit Token, transfer the same on STTD, access the prepaid energy meter website to down load the token number etc for recharging of prepaid energy meter complete. Note:- The contractor's rate is deemed to be included for the following:- (a) Soft ware installation complete with 1 year upgradation. (b) Eligible computer operator for look after the vending station for minium of 10 hrs in a day for 1 year. (c) The operator's are eligible to take reading and to prepare details and report once in a month complete all as specified and directed.\nMake : HP / DELL / ACER | BI01010001010000000000000515BI0100001116 | 1 | Each Set |
5 | 5 | Supply, Installation Creation Vending station Implementation for unlimited no of prepaid energy meters suitable for vending system data base defining/mapping of consumer & running the vending system with deployment of one data entry technician to impart 30 days in day shift of 08 Hrs to trained the MES personel concerened as detailed by the GE including inspection and maintenance of entire system complete in all respect required for functioning of entire system all as directed. | BI01010001010000000000000515BI0100001117 | 1 | Each Job |
6 | 6 | Transaction Charges/Token Generation Charges are to be paid Per Meter for three years in advance immediate after completion of installation of system complete all as directed.\nNote : The unit rate quoted includes for charges for three years per meter. | BI01010001010000000000000515BI0100001118 | 127 | Each Meter |
7 | 7 | Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLS PVC insulated flexible solid/multistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits concealed of suitable size, for 2 runs of 6 sq. mm main cable + 1 run of 4 Sq. mm earth cable complete all as specified and directed. \nNote: (i) Two different color wires shall be used for phase and neutral . \n (ii) Connections of cables with MCBs or bus bars shall be done through appropriate \n size brass/copper thimbles. \n (iii) If Necessary cutting chasing shall be included in this item.\nMake of wires : Finolex/Havells/Polycab\n | BI01010001010000000000000515BI0100001119 | 260 | RM |
8 | 8 | Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLS PVC insulated flexible solid/multistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits concealed of suitable size, for 2 runs of 10 sq. mm main cable + 1 run of 6 Sq. mm earth cable as in replacement of old unserviceable wiring complete all as specified and directed. \nNote: (i) Two different color wires shall be used for phase and neutral . \n (ii) Connections of cables with MCBs or bus bars shall be done through appropriate \n size brass/copper thimbles. \n (iii) If Necessary cutting chasing shall be included in this item.\nMake of wires : Finolex/Havells/Polycab\n | BI01010001010000000000000515BI0100001120 | 100 | RM |