Public Administrative Department Government Departments Closing in 0 days TDR #22580679

Tender For Civil Works - Roads -Mn07245 L028-T02 To Kabulong

Issued by Government Departments · Tamenglong, Manipur
Tender Value
13.84 Crore
Estimated cost
Bid Submission
30 Nov 2019
0 days left
EMD
27.69 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Rate Contract
Location / State
Tamenglong → Manipur
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Civil Works - Roads -Mn07245 L028-T02 To Kabulong

BOQ

Name of Work: L028-T02 to Kahulong District : Tamenglong Block : Tamenglong
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Setting out\nBI01010001010000000000000515BI0100001112
22Construction of Job pillers as per Fig. 1600.1 (d) and Technical Specification Clause 1602.4BI01010001010000000000000515BI01000011131Each
33Surface Drains in Soil\nConstruction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.A) Manual Means17000m
44Surface Drains in Ordinary Rock\nConstruction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.A) Manual Means4800m
55Excavation in Hilly Areas in Soil by mechanical means.\nExcavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per drawing and Technical Specification Clause 1603.1114818cum
66Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blasting\nExcavation in hilly area in ordinary rock not requiring blasting by mechanical means including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.37701.2cum
77Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blasting\nExcavation in hilly area in ordinary rock not requiring blasting by mechanical means including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.9397.5cum
88Construction of Subgrade and Earthen Shoulders\nConstruction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.14540.6cum
99Compacting original ground supporting subgrade\nLoosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.28200cum
1010Kilometre Stone\nReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
1111i) 5th Kilometre Stone (precast)4Each
1212ii) Ordinary Kilometer Stone (Precast)20Each
1313iii) 200 m stone (precast)94Each
1414Providing and Fixing 'Logo' of PMGSY Project\nProviding and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.11Each
1515Providing and Fixing of Citizen Information Board of PMGSY Project (Steel Tube)\nProviding and fixing of Citizen's Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.11Each
1616Providing and Fixing Maintenance Information Board of PMGSY Project\nProviding and fixing of maintenance Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5 mm size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the plates will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enamelled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing clause 1701 and Annexure 1700.11Each
1717Traffic Signs/Retro-reflectorised Traffic Signs\nProviding and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
1818a) 600 mm dia circle6Each
1919b) 600 mm equilateral triangle6Each
2020Providing and Fixing PMGSY Logo Board at starting point (Steel Tube)\nProviding and fixing of typical PMGSY Logo board as per MORD specifications and drawing. One plate of 1.6mm thick with MS flat 25mm x 5mm size on back on centre. The topmost diamond plate & mid. Plate will be welded to 75mm x 75mm 0f 12 SWG steel plate tube posts & dully embedded to CC 450mm x 450mm x 600mm below GL. Lettering and printing etc. will be with ready mixed synthetic enamel paint of superior.6Each
2121Direction and Place Identification signs upto 0.90 Sqm Size Board\nA. Retro-reflectorised Traffic Signs\nProviding and erecting direction and place identification retro-reflectorised sheeting vide clasue 1701.2.3., fixed over aluminium sheeting 2mm thick with area not exceeding 0.90 sqm supported on a mild steel angle iron posts 75 x 75 x 6 mm firmly fixed to the gorund by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600mm, 600mm below ground level as per approved drawing and technical specifications Clasuse 17012sqm
2222Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. i) Using naturally occuring gravel15275cum
2323WBM Grading 3 \nProviding, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. A) By Manual Means5287.5cum
2424Prime Coat:Low porosity\nProviding and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.A) By Manual Means70500sqm
2525Tack Coat\nProviding and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. A) By Manual Means70500sqm
262620 mm thick Open Graded Premix Carpet using Bitumen Emulsion as per Technical Specification Clause 508.2\nProviding, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case-I By Manual Means70500sqm
2727Seal Coat with Bitumen Emulsion Seal Coat Type (MS grade)\nProviding and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510.Case II : Type B (By Manual means)70500sqm
2828CONSTRUCTION OF PUCCA LINED DRAIN WORKS (L=1700m)
2929Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary Soil (i) Upto 3m depth.1517.25Cum
3030Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10229.5Cum
3131Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. III) Random Rubble Masonry (ii) In 1:4 Cement Mortar612Cum
3232Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 12043060sqm
3333Construction of Pipe Culvert(NP-3: 800mm dia: Dn Hill Hd Wall Ht-2.85m)12nos.
3434Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material977.04Cum
3535Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 110948.24Cum
3636Bedding for Pipe\nType B (First Class) Bedding. Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii)35.4Cum
3737Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109. (A) In 1:4 cement mortar454.56Cum
3838Providing and Laying DWC pipe as per design in Single Row \nProviding and laying DWC pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (B) 800mm dia.72m
3939Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification709.2Sqm
4040Construction of 1.50 m span RCC Slab Culvert 3.61 ht.)(4nos.)
4141Excavation for Structures\nEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary Soil (i) Upto 3m depth.364.8cum
4242Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:629.2cum
4343Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 i) PCC M 15 i) Nominal mix (1:2.5:5)267.36cum
4444Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. RCC Grade M 2523.4cum
4545Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 12023.3688mt
4646Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.772nos.
4747Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.857.6cum
4848Construction of 2.00m span slab culvert (Height - 3.44m)(1no.)
4949Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I) Ordinary Soil i) upto 3m depth189.45Cum
5050Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:615.67Cum
5151Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 i) PCC M 15 i) Nominal mix (1:2.5:5)77.01Cum
5252Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. RCC Grade M 255.12Cum
5353Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 12020.48805Mt
5454Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.732nos.
5555Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.845.41Cum
5656Construction of 4.00m span slab culvert (Height - 4.54m)(1no.)
5757Excavation for Structures\nEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary Soil (i) Upto 3m depth.192.88Cum
5858Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:614.74Cum
5959Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 i) PCC M 15 i) Nominal mix (1:2.5:5)111.73Cum
6060Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. RCC Grade M 2521.42Cum
6161Drainage spouts complete as per drawing and technical Specification Clause 12092Nos.
6262Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 12021.31824Mt
6363Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.32.48Cum
6464Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.746Nos.
6565Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.850.4Cum
6666Construction of Retaining Wall : Height 4.0 m (4 nos.)
6767Excavation for Structures\nEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I) Ordinary Soil i) upto 3m depth469.28cum
6868Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:642.63cum
6969Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 III) Random rubble masonry ii) In 1:4 cement mortar436.66cum
7070Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7119nos.
7171Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8322cum
7272Pointing with cement mortar (1:3) on brickwork as per drawing and technical sepecification clauses 613.3 and 1204370.02sqm
7373Construction of Gabion Wall Length 10.00m - (Height - 2.00m) 4 nos.
7474Excavation for Structures\nEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I) Ordinary Soil i) upto 3m depth200cum
7575Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (i) Granular material66.65cum
7676Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301. ( Based on SDB Rural Road Chapter-14, Item No.14.2)225cum
7777Maintenance component for 5(five) years after construction (not to be quoted yearwise)
78781st year Rs. 1258424.9
79792nd year Rs. 1887637.36
80803rd year Rs. 2516849.81
81814th year Rs. 3146062.26
82825th year Rs. 3775274.71

AI Tender Summary

OUR REF NO 22580679
AUTHORITY Government Departments
TENDER VALUE 13.84 Crore
LAST DATE 30-11-2019
Authority
Authority Name Rural Engineering Department
Work Description Tender For Civil Works - Roads -Mn07245 L028-T02 To Kabulong
Basic Detail
Tender No MN07245
Bidding Type Rate Contract
Location
City Tamenglong
State Manipur
Key Dates
Publish Date 20 Nov 2019
Submission Date 30 Nov 2019
Open Date 02 Dec 2019
Finance
Tender Value 13.84 Crore
Tender Fee 20000
EMD 27.69 Lakhs
Exemption Not Available
Document List
17ED234A-30FD-4C8D-88B6-8EF28640F831.html
Tendernotice_1.pdf
SBDBI18193RT.pdf
BOQ_149704.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 02, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

17ED234A-30FD-4C8D-88B6-8EF28640F831.html

pdf

Tendernotice_1.pdf

pdf

SBDBI18193RT.pdf

xls

BOQ_149704.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender