Director Of Health Services-DGHS has published Procurement Of 03 Three Equipments For Mru Agmc And Gbp Hospital Agartala .. Submission Date for this Tender is 23-12-2019. Storage Chests and Cabinets and Trunks Tenders in Principal AGMC AND GBP Hospital Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

22569681
Procurement Of 03 Three Equipments For Mru Agmc And Gbp Hospital Agartala .
Open Tender
Indian
Tripura
Principal AGMC AND GBP Hospital
23-12-2019

Tender Details

Procurement Of 03 Three Equipments For Mru Agmc And Gbp Hospital Agartala . - 2 -20 Degree Centigrade Freezer N• System Should Have Temperature Up To -25 Degree C. N• Should Have Built In Condenser For Flow Low Energy Consumption. N• No Dust. N• Low Noise. N• Combination Of Pull Out Drawers And Fast Freeze Shelves. N• Control Panel At The Top Of The Cabinet With Thermometer Or Temperature Warning Light. N• Thermostat. N• Fast Freeze Button And Lamp. N• Mains Warning Lamp. N• Single Door. N• Cfc Free Heavy Duty Compressor. N• Should Be Provided With 6-8 Shelves. N• Gross Capacity: 345Lt. 3 Automated Blood Cell Counter ( 3 Parts Diff. ) N• Three ( 3 ) Parts Differential Analysis. N• Minimum 20 Parameters. N• Hb Estimation Should Be Cyanide Free. N• Throughput – Minimum 60 Samples / Hr. N• Sampling Method: Open Tube / Cuvette System With Automated Sample Rotor. N• Sample Volume: N>Whole Blood: Upto 20Μl. N>Pre-Diluted: Upto 20Μl. N• Analysis Mode: Whole Blood And Pre-Diluted- Both. N• Barcode Reading Facility. N• Database Storage Capacity: More Than 30, 000 Results Combined With Histogram. N• Quality Control: 500 Files With L-J Graph And X-Bar Analysis. N• Int. Quality Assurance Programme. N• Built- In Printer. N• Result Display On Colour Lcd Screen. N• Facility For Serial Port & Lan Service. 4Usb ( For Connecting External Devices Including External Printer ) + 1Lan Port ( Hl7, Tcp / Ip; Lis Connectivity ) 4 Auto Analyser N• It Should Be Automated, Discrete, Random Access; Patient Prioritized Clinical Chemistry Analyzer Capable Of Performing Biochemistry And Immunoturbidimetry Assays. N• It Should Be A Floor Model. N• The Throughput Should Be At Least 400 Tests / Hr Photometric Tests For A Cycle Of 9 Seconds And 640 Tests / Hr With Ise ( Optional ) . N• It Should Have More Than 52 On Line Chemistries. N• It Should Not Have Any Limit On Number Of Programmable Chemistries, Profiles And Calculation Item. N• It Should Accept Linear, Non-Linear, Multi Point Calibration. N• Sample Disk Should Accept Minimum 75 Samples At A Time. All The Positions On The Sample Disk Should Accept Stat Samples, Blanks, Controls, Standards And Ise Solutions. N• It Should Accept 5 Ml, 7 Ml, 10 Ml And Sample Cups For Keeping Samples. N• The Sample Pipetting Should Be Between 2 – 70Μl In Steps Of 0.2 Μl. N• It Should Have A Sample Probe & Two Separate Reagent Probes For R1 & R2. N• The Reagent Tray Should Be Cooled At 4Degree C To 12Degree C And Should Have 56 Reagent Bottles. It Should Accept 20 Ml, 50 Ml Bottles And 5 Ml Adapters. N• Display Of Reaction Cuvette Temperature And Reagent Tray Temperature Should Be Available On Screen. N• Biohazard Waste Should Be Collected In A Separate Container. N• System Should Be Capable Of Performing 2 Reagent Chemistries. N• It Should Have Fixed Barcode Reader For Both Reagents And Samples ( Optional ) . N• Reagent Pipetting Should Be Between 10 – 300Μl In Steps Of 1 Μl. N• The Reaction Cuvettes Should Be 72 Permanent Hard Glass Cuvettes Maintained At 37 Degree C ± 0.2 Degree. N• On Line Reaction Graph Should Be Displayed On The Screen And All The Reaction Graphs Should Be Stored In The Memory. N• The Minimum Reading Volume Should Be 180 Μl. N• It Should Have On Board Laundry For Washing Of The Cuvettes. N• Photometer Should Consist Of 12 Wavelengths In The Range 340 To 750 Nm. It Should Be Capable Of Doing Monochromatic And Bichromatic Measurements. N• Light Source Should Be Pre Aligned Halogen Lamp ( 12 V / 20 W ) N• Absorbance Range Should Be 0.0 – 3.0 Abs. N• It Should Have Extensive Q. C. Program. Should Show Daily And Monthly Levy Jennings Chart And Twin Plot. N• It Should Have Facility Of Auto Re-Run, Auto Dilution Of Sample Facility, N• Facility Of Skipping Of Dirty Cuvettes Should Be Available. N• The Mixing Stirrer Should Have User Defined Variable Speed ( Minimum 3 Speeds ) . N• Probe Should Have Vertical Obstruction Detection.Power Requirement Should Be Ac 110 V ± 10% Hz And 60 ± 1 Hz Or Ac 220 V ± 10% Hz And 50±1 Hz.

Key Value

Document Fees
INR 1000 /-
EMD
INR 175000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: < Procurement of 03nos equipments for Multi-Disciplinary Research Unit (MRU), AGMC & GBP Hospital, Agartala (e-tender) >
Sl. No. Item Description Item Code / Make Quantity Units
1 1 items
2 1.01 -20 degree Centigrade Freezer\n• System should have temperature up to -25 degree C.\n• Should have built in condenser for flow low energy consumption.\n• No dust.\n• Low noise.\n• Combination of pull out drawers and fast freeze shelves.\n• Control panel at the top of the cabinet with thermometer or temperature warning light.\n• Thermostat.\n• Fast freeze button and lamp.\n• Mains warning lamp.\n• Single door.\n• CFC free heavy duty compressor.\n• Should be provided with 6-8 shelves.\n• Gross capacity: 345Lt. item1 1 Nos
3 1.02 Automated blood cell counter (3 parts diff.)\n• Three (3) parts differential analysis. \n• Minimum 20 parameters.\n• Hb estimation should be cyanide free.\n• Throughput – minimum 60 samples/hr.\n• Sampling method: Open tube/cuvette system with automated sample rotor.\n• Sample volume:\n>Whole Blood: upto 20µl.\n>Pre-diluted: upto 20µl.\n• Analysis mode: Whole Blood and Pre-Diluted- both.\n• Barcode reading facility.\n• Database storage capacity: more than 30,000 results combined with histogram.\n• Quality control: 500 files with L-J graph and X-Bar Analysis.\n• Int. Quality assurance programme.\n• Built- in Printer.\n• Result display on colour LCD screen.\n• Facility for Serial port & LAN service. 4USB (for connecting external devices including external printer) + 1LAN Port (HL7, TCP/IP; LIS connectivity) item2 1 Nos
4 1.03 Auto Analyser\n• It should be Automated, Discrete, Random Access; patient prioritized Clinical chemistry Analyzer capable of performing biochemistry and immunoturbidimetry assays.\n• It should be a floor model.\n• The throughput should be at least 400 tests/hr photometric tests for a cycle of 9 seconds and 640 tests/hr with ISE (optional).\n• It should have more than 52 on line chemistries.\n• It should not have any limit on number of programmable Chemistries, Profiles and Calculation Item.\n• It should accept Linear, Non-Linear, Multi Point Calibration.\n• Sample disk should accept minimum 75 samples at a time. All the positions on the sample disk should accept STAT samples, blanks, controls, standards and ISE solutions.\n• It should accept 5 ml, 7 ml, 10 ml and sample cups for keeping samples.\n• The sample pipetting should be between 2 – 70µl in steps of 0.2 µl.\n• It should have a sample probe & two separate reagent probes for R1 & R2.\n• The reagent tray should be cooled at 4degree C to 12degree C and should have 56 reagent bottles. It should accept 20 ml, 50 ml bottles and 5 ml adapters.\n• Display of Reaction Cuvette temperature and Reagent Tray temperature should be available on Screen.\n• Biohazard waste should be collected in a separate container.\n• System should be capable of performing 2 Reagent Chemistries.\n• It should have fixed barcode reader for both reagents and samples (Optional).\n• Reagent pipetting should be between 10 – 300µl in steps of 1 µl.\n• The reaction cuvettes should be 72 permanent hard glass cuvettes maintained at 37 degree C ± 0.2 degree.\n• On line Reaction Graph should be displayed on the screen and all the reaction graphs should be stored in the memory.\n• The minimum reading volume should be 180 µl.\n• It should have on board laundry for washing of the cuvettes.\n• Photometer should consist of 12 wavelengths in the range 340 to 750 nm. It should be capable of doing Monochromatic and Bichromatic measurements.\n• Light source should be pre aligned Halogen Lamp (12 V/20 W)\n• Absorbance range should be 0.0 – 3.0 Abs.\n• It should have extensive Q. C. program. Should show daily and monthly Levy Jennings Chart and Twin Plot.\n• It should have facility of auto re-run, auto dilution of sample facility,\n• Facility of Skipping of dirty cuvettes should be available.\n• The mixing stirrer should have user defined variable speed (minimum 3 speeds).\n• Probe should have Vertical obstruction Detection.Power Requirement should be AC 110 V ± 10% Hz and 60 ± 1 Hz or AC 220 V ± 10% Hz and 50±1 Hz. item3 1 Nos