| 1 | 1 | Dismantling of old ACSR Conductor of any size from existing HT/LT over head lines complete all as specified and directed. | BI01010001010000000000000515BI0100001113 | 1.44 | Per Qtl |
|---|
| 2 | 2 | Taking down carefully old insulators of any type/size from existing HT/LT over head lines complete all as specified and directed. | BI01010001010000000000000515BI0100001114 | 33 | Each |
|---|
| 3 | 3 | Dismantling of old cross arms of MS fabricated along with all accessories viz nut, bolts, washer etc. from existing HT/LT Poles complete all as specified and directed. | BI01010001010000000000000515BI0100001115 | 2.37 | Per Qtl |
|---|
| 4 | 4 | Dismantling of old HT 11 KV Air Break Switch (GOD) tripple pole with all accessories from existing HT 2/4 Pole Structure complete all as specified and directed. | BI01010001010000000000000515BI0100001116 | 2 | Each Set |
|---|
| 5 | 5 | Dismantling of old HT 11 KV Expulsion Fuse (Dropout Fuse) tripple pole with all accessories from existing HT 2/4 Pole Structure complete all as specified and directed. | BI01010001010000000000000515BI0100001117 | 2 | Each Set |
|---|
| 6 | 6 | Dismantling of old HT 11 KV Lightning Arresstor (LA) tripple pole with all accessories from existing HT 2/4 Pole Structure complete all as specified and directed. | BI01010001010000000000000515BI0100001118 | 2 | Each Set |
|---|
| 7 | 7 | Dismantling of old Stay Assembly alomg with all accessories from existing HT/LT Poles complete all as specified and directed. | BI01010001010000000000000515BI0100001119 | 2 | Each Set |
|---|
| 8 | 8 | Dismantling of old Steel tubular swaged pole/ PCC pole from existing complete all as specified and directed. | BI01010001010000000000000515BI0100001120 | 5 | Each |
|---|
| 9 | 9 | Excavation in trenches not exc 1.5 mtr in wide and not exc 1.5 mtr in depth for laying of under ground cable, pipes etc., and getting out in Hard / dense soil complete all as specified and directed.. | BI01010001010000000000000515BI0100001121 | 415 | Cum |
|---|
| 10 | 10 | Excavating in trenches, not exceeding 1.5 mtr wide and exceeding 1.5 mtr deep and not exceeding 3 mtr deep for excavation of poles and getting out in any type of soil complete all as specified and directed. | BI01010001010000000000000515BI0100001122 | 0.18 | Cum |
|---|
| 11 | 11 | Returning, filling in excavated soil in trenches including spreading levelling watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. | BI01010001010000000000000515BI0100001123 | 267 | Cum |
|---|
| 12 | 12 | Removing of excavated soil to a distance not exc 50 mtr and depositing where directed at level not exceeding 1.5 mtr above the starting point, complete all as specified and directed. | BI01010001010000000000000515BI0100001124 | 148 | Cum |
|---|
| 13 | 13 | M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed.\nNote :- Thickness of sand cushion after punning down shall be measured for payment. | BI01010001010000000000000515BI0100001125 | 88 | Cum |
|---|
| 14 | 14 | Supply and lay un-reinforced precast concrete cable cover Class HV, type 1 with peak of size 300 mm x 180 mm x 40 mm complete all as specified and directed. | BI01010001010000000000000515BI0100001126 | 4250 | Each |
|---|
| 15 | 15 | Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed. | BI01010001010000000000000515BI0100001127 | 1820 | Each |
|---|
| 16 | 16 | Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30 cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\" (inch) wide complete all as specified and directed.\n(Note :- Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this sch)\n\n | BI01010001010000000000000515BI0100001128 | 5 | Each |
|---|
| 17 | 17 | Material and labour for PCC 1:3:6 type C2 using 40mm size stone aggregate as in foundation mass concrete to pole all as specified and directed. | BI01010001010000000000000515BI0100001129 | 2.71 | Cum |
|---|
| 18 | 18 | Material and labour for PCC 1:2:4 type B1 using 20mm stone aggregate in coping to pole including form work all as specified and directed. | BI01010001010000000000000515BI0100001131 | 0.51 | Cum |
|---|
| 19 | 19 | S&F stay assembly comprising of 7/10 SWG galvanized MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps,bolts, nuts, washers, galvanized steel stay rod 16mm dia 180 cm long bow 400x14mm nuts/bolts, washers all gal-vanized and two nos thimble, loop insulator of size 65x90mm vitreous, clearance dia of hole 16mm, stay plate of size 230x230x6mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundatin and disposal of surplus soil, upto 50 M all as specified and shwon in plate No 1 of MES SSR Pt -I, and directed. | BI01010001010000000000000515BI0100001132 | 2 | Each Set |
|---|
| 20 | 20 | Supply and lay cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts (E) grade with stranded aluminium conductor, laid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminium conductor of size 95 Sqmm x 3 Core complete all as specified and directed. | BI01010001010000000000000515BI0100001133 | 275 | RM |
|---|
| 21 | 21 | All as per item No-20 above but size 120 Sqmm x 3 Core. | BI01010001010000000000000515BI0100001134 | 700 | RM |
|---|
| 22 | 22 | Supply and lay XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 25 Sqmm x 4 Core complete all as specified and directed (For connection of Pump Starter Panel Board). | BI01010001010000000000000515BI0100001135 | 40 | RM |
|---|
| 23 | 23 | All as per item No-22 above but size 10 Sqmm x 2 Core (For Street Light). | BI01010001010000000000000515BI0100001136 | 350 | RM |
|---|
| 24 | 24 | M&L for Pipe galvanised (Light Grade), laid in trenches or fixed to pole with necessary MS Clamps, bolts, nuts, washers etc complete as in protection of UG cable of the size 80 mm dia bore complete all as specified and directed. | BI01010001010000000000000515BI0100001138 | 24 | RM |
|---|
| 25 | 25 | All as per item No-24 above but size 25 mm dia bore. | BI01010001010000000000000515BI0100001139 | 15 | RM |
|---|
| 26 | 26 | Supplying, installing, testing and commissioning of Air Break Switch (GOD) HT 11 KV, TP Rocking tilting type, vertical mounting, mechanically operated from ground, mounted on insulators 11 KV grade and steel frame, current rating upto 200 Amps complete with fuse mounts, fuse carriers and fuse elements of required capacity and one pad lock 65 mm (Godrej/navtal) with two keys complete all as specified and directed. | BI01010001010000000000000515BI0100001140 | 2 | Each Set |
|---|
| 27 | 27 | Supply and fix testing and commissioning of Expulsion fuse (Drop out fuse), channel type suitable for working pressure 11 KV grade, including dismantling of unsv fuses complete all as specified and directed | BI01010001010000000000000515BI0100001141 | 2 | Each Set |
|---|
| 28 | 28 | S & F Lightning Arresters expulsion type suitable for HT 11000 volts grade, non liner resistor type, horn gap and chocking coil with all fittings for outdoor use, transmission class, discharge capacity 65 kA complete all as specified and directed | BI01010001010000000000000515BI0100001142 | 2 | Each Set |
|---|
| 29 | 29 | M&L for HT 25 x 20 cm size Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size complete all as specified and directed. | BI01010001010000000000000515BI0100001143 | 4 | Each |
|---|
| 30 | 30 | S&F Cable jointing kit for 11 KV (Earthed) grade cable for Straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed . | BI01010001010000000000000515BI0100001144 | 1 | Each |
|---|
| 31 | 31 | S&F Cable jointing kit (Heat Shrinkable) for 11 KV (Earthed) grade cable for Outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm complete all as specified and directed. | BI01010001010000000000000515BI0100001145 | 4 | Each |
|---|
| 32 | 32 | All as per item No-31 here in before but of size 95 Sqmm. | BI01010001010000000000000515BI0100001146 | 3 | Each |
|---|
| 33 | 33 | S&F Cable Route indicator duly marked with \"HT/LT UG cable\" CI plate elliptical shape with 12mm dia MS rod not less than 700mm in length and embeded in PCC block 1:3:6 of size 300x300x300mm in gound including necessary earth work complete all as specified and directed. | BI01010001010000000000000515BI0100001147 | 34 | Each |
|---|
| 34 | 34 | M & L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by hudraulic pipe jacking technique complete including tunneling, excavation in any types of soils including hard rock, MS Casing pipe heavy duty of size 100 mm dia with 6 mm thick in any length including jointing materials to carry LT UG cables of size up to 185 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed. | BI01010001010000000000000515BI0100001148 | 12 | RM |
|---|
| 35 | 35 | All as per item No-34 here in before but of size 80mm dia. | BI01010001010000000000000515BI0100001149 | 6 | RM |
|---|
| 36 | 36 | S&F Junction box of size 333x233x120mm outdoor type complete with three phase and neutral, aluminium bus bar 25x4 mm size and one MCB 6 Amps SP 10 KA including fixing with two nos flat iron 25x4 mm clamps of suitable size with necessary mild steel nuts & bolts complete all as specified and directed. | BI01010001010000000000000515BI0100001150 | 5 | Each |
|---|
| 37 | 37 | S&F twisted copper cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 sqmm, complete all as specified and directed. | BI01010001010000000000000515BI0100001151 | 30 | RM |
|---|
| 38 | 38 | M&L Street light bracket made out of 60 cm long 40 mm dia light grade GI pipe welded to 200 mm long 100 mm GI pipe with provision of nut and bolts for fixing on top of the pole duly painted with two coats of silver paint over a coat of red oxide primer complete all as specified and directed. | BI01010001010000000000000515BI0100001152 | 5 | Each |
|---|
| 39 | 39 | S&F new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 60 Watts with suitable drivers etc and connecting with 2.5 sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall / pole with and including bracket made out of GI pipe of suitable dia light grade not less than 1.5 mtr long, bent to shape, fixed to Pole/Wall in any position with flat iron clamps of size 30 x 4mm complete all as specified and directed. \nMake :- Havells (Endura Pulse) Cat No- LHETBXU7PA6J060 or techno commercially equivalent model in Bajaj (Edge Series of LED Street Light) Cat No- BRTFG 60W LED V3 and Wipro (Sky Line LED) Cat No-LR02-671-XXX-57-G2. \nNotes :- \n(i) LED's used should be the make of Cree/Osram/Lumilieds/Nitchia, \n(ii) Contractor has to produce LM-79/ LM-80 certificate along with purchase vouchers. \n(iii) Surge protection of the drive should be 10 KV or equivalent model in Bajaj / Philips or Wipro.\n | BI01010001010000000000000515BI0100001153 | 5 | Each |
|---|
| 40 | 40 | M & L for Earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr deep below normal ground level, connected to pole/LA etc and incl GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers, protected with and incl 15 mm dia light grade GI pipe, 20 mm dia GI pipe (Medium grade) for watering, necessary earth work. PCC 1:3:6 type C1 concrete pit, RCC (1:1.5:3) type A1 pre-cast cover (54X54X5 cm) duly reinforced with and incl 8 mm dia TMT bar @ 150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar, embedded in pre-cast cover slab complete all as specified and shown in electrical plate No-3 of SSR Part-I incl testing on completion. | BI01010001010000000000000515BI0100001154 | 4 | Each |
|---|
| 41 | 41 | Taking up or down Steel water tubing (GI) and connections of size 40 / 50 mm dia bore from existing pipe lines complete all as specified and directed. | BI01010001010000000000000515BI0100001155 | 270 | RM |
|---|
| 42 | 42 | Taking up or down Steel water tubing (GI) and connections of size 25 / 32 mm dia bore from existing pipe lines complete all as specified and directed. | BI01010001010000000000000515BI0100001156 | 100 | RM |
|---|
| 43 | 43 | Taking up or down Gun Metal Gate Valve and Non Return Valve of any size from existing pipe lines complete all as specified and directed. | BI01010001010000000000000515BI0100001157 | 8 | Each |
|---|
| 44 | 44 | Disconnectin of all electrical connections and taking up of old existing Pump Stater Panel Board and shifting to another location and re-connecting by provide of Aluminum lugs, glands, single core copper wire etc at required site for after completion of shifting complete all as specified and as directed. | BI01010001010000000000000515BI0100001158 | 1 | Each Job |
|---|
| 45 | 45 | Supply & Fixing/ Laying Galvanised steel water tubing (Medium Grade), ISI Marked with all new GI Fittings laid in trenches etc of size 50 mm dia bore complete all as specified and as directed. | BI01010001010000000000000515BI0100001162 | 150 | RM |
|---|
| 46 | 46 | All as per item No-45 above but size 40 mm dia bore. | BI01010001010000000000000515BI0100001163 | 120 | RM |
|---|
| 47 | 47 | All as per item No-45 above but size 25 mm dia bore.\n(Note :- Excavation and Earth work shall be measured and paid separately) | BI01010001010000000000000515BI0100001164 | 100 | RM |
|---|
| 48 | 48 | Supply and Fix Gunmetal Gate valve with iron wheel head, screwed both ends, ISI marked Heavy duty fixed to GI pipes suitable of size 50 mm dia complete all as specified and as directed. | BI01010001010000000000000515BI0100001166 | 1 | Each |
|---|
| 49 | 49 | All as per item No-48 above but size 40 mm dia bore. | BI01010001010000000000000515BI0100001167 | 2 | Each |
|---|
| 50 | 50 | All as per item No-48 above but size 25 mm dia bore. | BI01010001010000000000000515BI0100001168 | 4 | Each |
|---|
| 51 | 51 | Supply and Fix Non Return valve with iron wheel head, screwed both ends, ISI marked Heavy duty fixed to GI pipes suitable of size 50 mm dia complete all as specified and as directed. | BI01010001010000000000000515BI0100001169 | 1 | Each |
|---|
| 52 | 52 | S&F PVC insulated 3 core sheathed Submersible flat cables of size 2.5 Sqmm for Submersible Pumps with Copper conductor, 1100 Volts grade, conforming to IS:694/1990 with latest amendments ISI complete all as including disconnecting/taking out old existing unsv cable complete all as specified and directed. Make : Richa/Havells or equivalent. | BI01010001010000000000000515BI0100001170 | 200 | RM |
|---|