Tender For Comprehensive Maintenance Of Sewage Installations At Various Locations Sewage Treatment Plant Capacity 300 Kld At Map Ph Ii And Repair/Maintenance Of Lt Panels Steel Gates Etc And Other Connected Services Under Ge Babina, BABINA CANTT-Uttar Pradesh

Military Engineer Services-MES has published Tender For Comprehensive Maintenance Of Sewage Installations At Various Locations Sewage Treatment Plant Capacity 300 Kld At Map Ph Ii And Repair/Maintenance Of Lt Panels Steel Gates Etc And Other Connected Services Under Ge Babina. Submission Date for this Tender is 09-12-2019. Electrical Panel Tenders in BABINA CANTT Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

22565850
Tender For Comprehensive Maintenance Of Sewage Installations At Various Locations Sewage Treatment Plant Capacity 300 Kld At Map Ph Ii And Repair/Maintenance Of Lt Panels Steel Gates Etc And Other Connected Services Under Ge Babina
Open Tender
Indian
Uttar Pradesh
BABINA CANTT
09-12-2019

Tender Details

Tender For Comprehensive Maintenance Of Sewage Installations At Various Locations Sewage Treatment Plant Capacity 300 Kld At Map Ph Ii And Repair/Maintenance of Lt Panels Steel Gates Etc And Other Connected Services Under Ge Babina

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: COMPREHENSIVE MAINT OF SEWAGE INSTALLATIONS AT VARIOUS LOCATIONS , SEWAGE TREATMENT PLANT CAPACITY 300 KLD AT MAP PH-II AND REPAIR/MAINT OF LT PANELS , STEEL GATES ETC AND OTHER CONNECTED SERVICES UNDER GE BABINA
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for pole / cable / foundation etc including getting out in hard / dense soil complete all as specified and directed. 396 Cum
2 2 Excavation in trenches exc 1.5 mtr wide and n. exc 3 mtr depth for pole / cable / foundation etc including getting out in hard / dense soil complete all as specified and directed. 2 Cum
3 3 Returning filling in trenches including spreading, leveling, watering and well ramming in layer not exc. 25 cm in any type of soil after the pipe are laid & tested complete all as specified and directed. 190 Cum
4 4 Removing excavated soil to a distance n. exc. 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as specified and directed. 112 Cum
5 5 M & L for laying of dry, clean fine sand as in cushion to cable filling in trenches or around underground cable in cable ducts etc complete all as specified and directed. 190 Cum
6 6 Supplying and laying precast concrete cable cover class LV type -I flat size 250x150x40 mm laid parpendicular to the axis of cable in trenches etc complete as directed. Make: Make: M/S MEHATAB TILES, Rani Shopping Centre, Bhanwar, Indore,(B) M/S NAVYA TILES, 68, NEHRU PARK, SARDARPUR,JODHPUR- 342003 Ph. 0291-2650094, 2627963(C) SAP PAVERS JODHPUR (D) SAGAR TILES SAHARANPUR (E) Star Tiles & Industries, Rama Devi, Kanpur 9778 Each
7 7 M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles all as specified and directed 7 Cum
8 8 M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed 20 Cum
9 9 M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed 3 Cum
10 10 M & L for road cutting incl excavation in trenches in any type of starta /soils for laying of pipe , width not exc 45 cm wide and n.exc 75 cm depth and filled with cement concrete (1:3:6) type C-1 and top surface neatly finished as per existing bitumineous surface etc complete all as specified and directed. 50 RM
11 11 Supply ,laying and testing in replacement PVC Insulated, unsheathed multi stranded copper conductor cable, heavy duty, 1100 Volts grade 4 core 10 Sqmm for connection from LT panel board to motor starters and from starters to electric motors including necessry cable end termination with copper lugs of suitable size all as directed, confirmong to IS:694drawn through concealled heavy grade PVC conduites of not less than 32 mm nominal dia with necessary fittings such as bends, sockets etc. laid under the floor or fixed to the walls with suitable clamps or saddles including taking down of existing cable all as specified and directed 100 RM
12 12 Supply ,laying and testing in replacement PVC Insulated, unsheathed multi stranded copper conductor cable, heavy duty, 1100 Volts grade single core 16 Sqmm in replacement for connection from LT panel board to motor starters and from starters to electric motors including necessry cable end termination with copper lugs of suitable size all as directed, confirmong to IS:694drawn through concealled heavy grade PVC conduites of not less than 32 mm nominal dia with necessary fittings such as bends, sockets etc. laid under the floor or fixed to the walls with suitable clamps or saddles including taking down of existing cable all as specified and directed 100 RM
13 13 Supply ,laying and testing in replacement cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cable(heavy duty) 1100V grade with stranded aluminium conductor of Size 35 SqmmX3.5 core including taking out of existing cable all as specified and directed 200 RM
14 14 Supply ,laying and testing in replacement cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cable(heavy duty) 1100V grade with stranded aluminium conductor of Size 25 SqmmX3.5 core including taking out of existing cable all as specified and directed 300 RM
15 15 Burning of run lead 450mm joint in position incuding removing old lead to store and making run lead joint with fresh ( new) lead and spun yarn etc complete all as specified and directed 4 Each
16 16 As per item No:15 above but dia 150 mm 2 Each
17 17 As per item No:15 above but dia 100 mm 2 Each
18 18 As per item No:15 above but dia 80 mm 1 Each
19 19 Supply and Fix CI pipe with spigot and socket ends, class LA, centrifugally cast, laid in trenches, or under floors or fixed to walls, of sizes 150 mm bore complete all as specified and directed Make : Jayaswal ,Necco, Kapilansh (M/s Kapilansh Dhatu Udyog) Ltd Nagarpur, Ashutosh Iron Factory Nagpur 55 RM
20 20 All as per item No 19 but 100 mm bore 60 RM
21 21 Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead of size 150 mm bore complete all as specified and directed :- 55 RM
22 22 All as per item No 21 but 100 mm bore 60 RM
23 23 M & L for cast iron fittings of any description i.e bends (any type radius and angle ),tappers any type (straight ,bend increasing decreasing or double socket etc ),Tee pieces single branch Y junction ,double branch cross,(all socketed or socket and spigot),connecting pieces (one side flanged other socketed or spigot and bell mouth pieces one end flanged other tapering as bell mouth or both flanged /both socketed end as directed ) including collars ,caps and plugs upto 300 mm bore pipe and including nut bolts ,packing materials etc and making joint leak proof complete all as specified and directed .\nNOTE:-(i) Excavation & earth work and Joints shall be measured and paid for separately under appropriate item of Sch ’A’\n(ii) Weight of fitting shall be actual weight or weight for each fitting given in IS code IS-1538-1976 (Part-I to xxv)\n \n 350 KG
24 24 S&F in replacement mild steel column pipe 150mm nominal dia, heavy duty with MS flange screw and welded both ends, flanges fabricated from 16mm thick MS plate with 4 Nos MS ribs of 10mm thick for each flange complete all as specified and directed. 18 RM
25 25 S&F in replacement mild steel column pipe 100MM nominal dia, heavy duty with MS flange screw and welded both ends, flanges fabricated from 16mm thick MS plate with 4Nos MS ribs of 10mm thick for each flange complete all as specified and directed. 36 RM
26 26 S&F in repalcement butterfly CI valve (ISI Marked) Size 50mm bore etc complete all as specified and directed . Make : Leader/Sant/Zoloto 2 Each
27 27 Taking out old un-serviceable GI pipes, laid in trenches or under floors or fixed to walls including all fittings and disconnecting from branch connections complete all as specified & directed, for sizes 100mm bore 90 RM
28 28 All as per item no :27 but 80 mm bore 250 RM
29 29 All as per item no :27 but 65 mm bore 175 RM
30 30 All as per item no :27 but 40mm bore 12 RM
31 31 All as per item no :27 but 25mm bore 54 RM
32 32 All as per item no :27 but 20 mm bore 60 RM
33 33 S & F galvanised steel water tubing heavy grade 100 mm bore ( ISI Marked ) with all fittings such as bends, elbow, socket etc laid under floors/trenches or on walls with fixing arrangments complete all as specified and directed.Make: Jindal/Prakash Surya /Tata \n 90 RM
34 34 All as per item no :33 but 80 mm bore 250 RM
35 35 S & F galvanised steel water tubing medium grade 65 mm bore ( ISI Marked ) with all fittings such as bends, elbow, socket etc laid under floors/trenches or on walls with fixing arrangments complete all as specified and directed.Make: Jindal/Prakash Surya /Tata \n 175 RM
36 36 All as per item no :35 but 40mm bore Make: Jindal/Prakash Surya /Tata \n 12 RM
37 37 All as per item no :35 but 25mm bore Make: Jindal/Prakash Surya /Tata \n 54 RM
38 38 All as per item no :35 but 20 mm bore Make: Jindal/Prakash Surya /Tata \n 60 RM
39 39 M&L for cleaning of sludge chamber of dia up to 4.5mtr and depth up to 7 mtr manually including de-watering and removing all sedimented particles of sludge,mud,sand ,vegetation etc,from the clarifer sump and deposting where directed to a distance not exceeding 50mtr including brushing / scrubbing to remove all scales of fungus growth from the entire surfaces of chamber and cleaning thoroughly with fresh water etc complete all as directed . Note: (1) After cleaning of chamber Applying a thick coat lime wash to entire interior surfaces of chamber (ii) Adequate numbers of man power shall be deployed ,necessary T&P, safety equipments to person deployed on work and necessary precautions for the safety of individuals at site is the responsibility of the contractor and the cost of these all aspects deemed to be inlcuded in the quoted rate. (2) All inlet/outlet pipes/ channels shall be properly sealed at the opening inside the clarifer while carring out cleaning. 475 Cum
40 40 M&L for cleaning of sludge chamber of size 7x7x1.50 Mtr depth manually including de-watering and removing all sedimented particles of sludge,mud,sand ,vegetation etc,from the clarifer sump and deposting where directed to a distance not exceeding 50mtr including brushing / scrubbing to remove all scales of fungus growth from the entire surfaces of chamber and cleaning thoroughly with fresh water etc complete all as directed . Note: (1) After cleaning of chamber Applying a thick coat lime wash to entire interior surfaces of chamber (ii) Adequate numbers of man power shall be deployed ,necessary T&P, safety equipments to person deployed on work and necessary precautions for the safety of individuals at site is the responsibility of the contractor and the cost of these all aspects deemed to be inlcuded in the quoted rate. (2) All inlet/outlet pipes/ channels shall be properly sealed at the opening inside the clarifer while carring out cleaning. 300 Cum
41 41 M&L for cleaning of sludge chamber of size 8x8x10 Mtr depth manually including de-watering and removing all sedimented particles of sludge,mud,sand ,vegetation etc,from the clarifer sump and deposting where directed to a distance not exceeding 50mtr including brushing / scrubbing to remove all scales of fungus growth from the entire surfaces of chamber and cleaning thoroughly with fresh water etc complete all as directed . Note: (1) After cleaning of chamber Applying a thick coat lime wash to entire interior surfaces of chamber (ii) Adequate numbers of man power shall be deployed ,necessary T&P, safety equipments to person deployed on work and necessary precautions for the safety of individuals at site is the responsibility of the contractor and the cost of these all aspects deemed to be inlcuded in the quoted rate. (2) All inlet/outlet pipes/ channels shall be properly sealed at the opening inside the clarifer while carring out cleaning. 320 Cum
42 42 M&L for empty of liquid/semi solid contents of sludge from sludge chamber with the help of diesel driven pump set having suction up to 7 mtr and discharge up to 10Mtr from the sludge chamber all as specified and directed by Engr-in-charge Note:-(i) Diesel and transporting of sludge/human excreta in covered vehicle is deemed to be included in the quoted rates. (ii) Sludge chamber shall be empty within one day from the date of order /receipt by the contractor. Any delay boyond 1 day time shall be compensated through a penal recovery @ Rs. 500 per day per installation. 50 Cum
43 43 M&L for earthing complete including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 40 mm dia. light grade pipe and watering pipe shall be 20 mm ore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc. complete all as directed. Note : The conctrete pit shall be PCC 1:3:6 type C1, 40 mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @10 cm C/C on both sides with suitable cast iron handle shall be provided in liew of cast iron cover shown in electrical plate No.5 of MES SSR Part-1 (ii) Item includes the cost of 7.5 m GI pipe for protectio of earth strip. (iii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends , elbows etc. shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length earth strip. 30 Each set
44 44 S&F in replacement GI earth strip 32X6 mm fixed to wall, on battens, or recess or chases or buried in found, complete all as specified and as directed. 100 RM
45 45 M&L for MS Fabrication work in replacement ,made out of structural steel sections as in frame work for cable & piping ducts/MS door panels etc at sewage installation ,MS angle /flats/plain sheet of appropriate gauge ,cut to size and made to the existing shape suitable for fixing MS chequred duct cover /door panel including nut and bolts and washers ,welding bracing work bending cold or hot drilling holes for bolts in any shapes or sizes as reqired including one coat of primer and two coat of synthetic enamel paint to the entire steel surface all as specified and directed.Note :Cost of dismantling/taking down existing MS work of any description shall demed to be inclded in unit quoted rate . 2 Qtl
46 46 Taking out or down old unserviceable CI sluice valves/non return valve etc, up to 150 mm dia any make/type complete all as specified and directed 20 Each
47 47 S & F in replacement of cast iron sluice valve of 150 mm bore class PN-1.6 ISI marked (as per IS 14846 of 2000) heavy duty with flanged ends with gun metal spindle and gun metal check nut, iron hand wheel and fixing with providing suitable nuts, bolts, washers and rubber gasket for packing etc complete all as specified and directed. Make: Kirloska/Upadhaya /Sant Note:- Any damage if occurs while replacing the sluice valve to pipe lines, over head reservoir will be responsibilty of contractor and will be repaired by contractor at his own cost. Nothing extra will be admissible on this account. 3 Each
48 48 S & F in replacement of cast iron sluice valve of 100 mm bore class PN-1.6 ISI marked (as per IS 14846 of 2000) heavy duty with flanged ends with gun metal spindle and gun metal check nut, iron hand wheel and fixing with providing suitable nuts, bolts, washers and rubber gasket for packing etc complete all as specified and directed. Make: Kirloska/Upadhaya /Sant Note:- Any damage if occurs while replacing the sluice valve to pipe lines, over head reservoir will be responsibilty of contractor and will be repaired by contractor at his own cost. Nothing extra will be admissible on this account. 3 Each
49 49 S & F in replacement of cast iron sluice valve of 80 mm bore class PN-1.6 ISI marked (as per IS 14846 of 2000) heavy duty with flanged ends with gun metal spindle and gun metal check nut, iron hand wheel and fixing with providing suitable nuts, bolts, washers and rubber gasket for packing etc complete all as specified and directed. Make: Kirloska/Upadhaya /Sant Note:- Any damage if occurs while replacing the sluice valve to pipe lines, over head reservoir will be responsibilty of contractor and will be repaired by contractor at his own cost. Nothing extra will be admissible on this account. 2 Each
50 50 S&F in replacement cast iron foot valves of 150mm bore PN 1.6 as per IS 14846 to 2000 heavy duty with new rubber packing & nut, bolts complete all as specified and directed.Make : Kirloskar/Zoloto/Sant/Leader/Kejriwal 2 Each
51 51 S&F in replacement cast iron foot valves of 100mm bore PN 1.6 as per IS 14846 to 2000 heavy duty with new rubber packing & nut, bolts complete all as specified and directed.Make : Kirloskar/Zoloto/Sant/Leader/Kejriwal 4 Each
52 52 S&F in replacement cast iron foot valves of 80mm bore PN 1.6 as per IS 14846 to 2000 heavy duty with new rubber packing & nut, bolts complete all as specified and directed.Make : Kirloskar/Zoloto/Sant/Leader/Kejriwal 1 Each
53 53 S&F cast iron non return valves 150mm bore swing type both end flanged PN 1.6 as per IS 5312 including necessary items such as nut, bolts, washers, rubber packing complete all as specified and directed.Make : Zoloto/Sant/Leader/Kejriwal 2 Each
54 54 S&F cast iron non return valves 100mm bore swing type both end flanged PN 1.6 as per IS 5312 including necessary items such as nut, bolts, washers, rubber packing complete all as specified and directed.Make : Zoloto/Sant/Leader/Kejriwal 2 Each
55 55 S&F cast iron non return valves 80mm bore swing type both end flanged PN 1.6 as per IS 5312 including necessary items such as nut, bolts, washers, rubber packing complete all as specified and directed.Make : Zoloto/Sant/Leader/Kejriwal 1 Each
56 56 Suppling and fixing in replacement of Gun metal gate valve 20 mmbore with all GI fitting as per existing all as specified and directed Make : Zoloto/Sant/Leader 2 Each
57 57 Suppling and fixing in replacement of Gun metal gate valve 25 mmbore with all GI fitting as per existing all as specified and directed Make : Zoloto/Sant/Leader 2 Each
58 58 Suppling and fixing in replacement of Gun metal gate valve 40 mm bore with all GI fitting as per existing all as specified and directed, Make : Zoloto/Sant/Leader 1 Each
59 59 Suppling and fixing in replacement of Gun metal gate valve 50 mm bore with all GI fitting as per existing all as specified and directed.Make : Zoloto/Sant/Leader 1 Each
60 60 Supply installation ,commissioning and testing of LT panel indoor type, 433 volts,3 phase ,4 wire ,floor mounted,weather vermin proof factory made,CPRI approved,facricated out of 3.15 mm thick mild steel sheet mounted ,on frame of mild steel angle iron 50mm X 50mm X 6mm , 45 CM above the ground level duly supported with mild steel angle iron 50mm X 50mm X 6 mm thick in PCC fondation (1:2:4) ,type B-1,Using 20mm graded crushed stone aggregate ,LT panel shall be totally enclosed with front double door and rear opening with IP-54 protection as per IS/8623 duly powder coated for having TPN Aluminium bus bars suitable for 500 Amp load duly drilled holes for connection ,RYB insulated with ndiffrent colour code and sleeved insulators complted prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs/gland complete all as specified and directed by Engr-in-Chrge and also comprissing of following:-INCOMING: (i) MCCB 4P,415V ,100 Amps 25KA breaking capacity with termal adjustable setting-01 Nos (ii) Phase indication light & control uses-01 Nos (iii) Aluminium bas bar 3 phase 4 strip suitable for 100 Amp current carring capacity complete with post insulators and heat shrinkable sleeves OUTGOING : (i) MCCB 4P,415V ,63 Amps 24KA breaking capacity with termal adjustable setting-02 Nos (ii) Phase indication with led lamp(RYB)& control fuses set of three -01 Nos (iii) Bus bar chamber with and including Aluminium Strip (4 Nos) suitable for 100 Amp duly insulated,wired & duly mounted on porcelain insulators (iv) Multifuction digital meter CT operated suitable for showing voltage current ,HZ,KW,KWH etc (v) Cosmic star fully automatic star delta starter (ASD) suitable for 12.5HP to 15HP motor including overload relasy and single phase preventer/Corrector- 02 Nos 2 Each job
61 61 Repair/comprehensive maintenance of MBBR based sewage plant at MAP Ph-II (Sudhakar Madhav Enclave) at Babina Cantt having control panel incoming outgoing supply, serviceable starter, contact, relay, connection, pump motor ,UG sewage collection chamber ,sluice vave of any size,suction pipe with footvalve and delvery connection,to ensure proper functioning and 100% serviceability of all the plant. \n(A) The details of plants are as under :-\n (a) Air blower with motor - 01 Unit.\n (b) Non clogging feeding pump, 15 HP - 01 unit. \n (c) Non clogging feeding pump, 02 HP- 01 Unit. \n (d) Filter motor/pump1.5 HP - 01 Unit.\n (e) Dosing pump - 01 Unit.\n (f) Centrifugel pump 10 HP - 01 Unit.\n(B) Replacement of all unserviceable spare parts including carring out necessary repair/maintenance as mentioned below:- (i) Daily checking of moter,pump,starter,panel board ,sluice valve,NRV,suction/delivery pipe . (ii) Daily cleanig of sewage installaton. (iii) Checking of bearing of moter and pump (iv) Checking all electic connection,voltmeter and ammeter. (v) checking of water pressure gauge. (vi) Daily visual inspection of sump (vii) Checking of leakage at suction /delivery end Note:- \n(i) Spare parts such as greace,PVC insulation tape,gland packing,studes and other minor item are deemed to be included in the quoted rate. (ii) Proper record of repair /daily maintenance carried out and duly signed by the Engr-in-charge/JE will be mainained . 66 Each unit
62 62 Repair/comprehensive maintenance of W Wing Sewage plant, BO's Line Sewage plant & ISF Line Sewage plant at Babina Cantt having control panel incoming outgoing supply, serviceable starter, contact, relay, connection, pump motor ,UG sewage collection chamber ,sluice vave of any size,suction pipe with footvalve and delvery connection,to ensure proper functioning and 100% serviceability of all the plant. \n(A) The details of plants are as under :- (a) Non clogging type C/F pump sets, 20 - 30 HP cap with LT electrical control panel and starters at w Wing sewage plant (b) Non clogging type C/F pump sets, 10 - 15 HP cap with LT electrical control panel and starters at BO's line sewage plant (c) Non clogging type C/F pump sets, 15-10 HP cap with LT electrical control panel and starters at ISF line sewage plant (d) Replacement of all unserviceable spare parts including carring out necessary repair/maintenance as mentioned below:- (i) Daily checking of moter,pump,starter,panel board ,sluice valve,NRV,suction/delivery pipe . (ii) Daily cleanig of sewage installaton. (iii) Checking of bearing of moter and pump (iv) Checking all electic connection,voltmeter and ammeter. (v) checking of water pressure gauge. (vi) Dialy visual inspection of sump (vii) Checking of leakage at suction /delivery end Note:- \n(i) Spare parts such as greace,PVC insulation tape,gland packing,studes and other minor item are deemed to be included in the quoted rate. (ii) Proper record of repair /daily maintenance carried out and duly signed by the Engr-in-charge/JE will be maintained . 33 Each unit
63 63 Repair/comprehensive maintenance of Zone-04 Sewage plant, Zone-08 Sewage plant & Zone-03 Sewage plant at Babina Cantt having control panel incoming outgoing supply, serviceable starter, contact, relay, connection, pump motor ,UG sewage collection chamber ,sluice vave of any size,suction pipe with footvalve and delvery connection,to ensure proper functioning and 100% serviceability of all the plant. \n(A) The details of plants are as under :- (a) Non clogging type C/F pump sets, 7.5 to 10 HP cap with LT electrical control panel and starters at Zone 4 sewage plant. (b) Non clogging type C/F pump sets, 7.5 to 10 HP cap with LT electrical control panel and starters at Zone 8 sewage plant. \n(B) Replacement of all unserviceable spare parts including carring out necessary repair/maintenance as mentioned below:- (i) Daily checking of moter,pump,starter,panel board ,sluice valve,NRV,suction/delivery pipe . (ii) Daily cleanig of sewage installaton. iii) Checking of bearing of moter and pump (iv) Checking all electic connection,voltmeter and ammeter. (v) checking of water pressure gauge. (vi) Dialy visual inspection of sump (vii) Checking of leakage at suction /delivery end Note:- Spare parts ts such as greace,PVC insulation tape,gland packing,studes and other minor itemare deemed to be included in the quoted rate. \n(viii) Proper record of repair /daily maintenance carried out and duly signed by the Engr-in-charge/JE will be mainained . 22 Each unit
64 64 Repair/comprehensive maintenance of Zone-12 Sewage plant Sewage Treatment plant at Babina Cantt having control panel incoming outgoing supply, serviceable starter, contact, relay, connection, pump motor ,UG sewage collection chamber ,sluice vave of any size,suction pipe with footvalve and delvery connection,to ensure proper functioning and 100% serviceability of all the plant. Details of plants are as under :- (a) Non clogging type C/F pump sets, 12.5 HP cap at STP plant -01 unit (b) Blower unit wth motor, LT panel board, starter and connected piping system at STP plant - 01 unit (c) Non clogging type C/F pump sets capacity 12.5 HP with LT electrical control panel and starters at Zone 12 sewage plant. (B) Replacement of all unserviceable spare parts including carring out necessary repair/maintenance as mentioned below:- (i) Daily checking of moter,pump,starter,panel board ,sluice valve,NRV,suction/delivery pipe . (ii) Daily cleanig of sewage installaton. (iii) Checking of bearing of moter and pump (iv) Checking all electic connection,voltmeter and ammeter. (v) checking of water pressure gauge. (vi) Dialy visual inspection of sump (vii) Checking of leakage at suction /delivery end Note:- Spare parts such as greace,PVC insulation tape,gland packing,studes and other minor item which are not otherwise specified in the schedule but are required to ensure smooth functioning of the sewage plant are deemed to be included in the quoted rate. \n(viii) Proper record of repair /daily maintenance carried out and duly signed by the Engr-in-charge/JE will be mainained . 33 Each unit
65 65 Dismantling existing water tank of any size and capcity from various sewage plant complete all as specified and directed 4 Each
66 66 Supply and fixing in replacement of 1000 ltr capacity of rotational moulded polyethylene water storage tank 3 layered construction ISI marked WHITE , cylindrical vertical with closed top hoisted and fixing in position including 20mm GI pipe medieum grade wash out pipe 450 mm long with and 20mm dia GI pipe medium grade over flow pipe 600mm long with fitting including dismantling of existing water tanks of any type and capacity exceeding 1000 tr complete all as directed Make: Syntex /Polywell/Rotex 4 Each
67 67 Supply and fix PVC bib tap of size 25 mm bore and fixed to supply line etc complete as directed Make : Prayag/Polytuff 2 Each
68 68 Supply and fix PVC bib tap of size 20 mm bore and fixed to supply line etc complete as directed . Make : Prayag/Polytuff 2 Each
69 69 M&L for preperation of old decorated surface of steel and applyng one coat of synthetic enamel paint on exterior surface of steel structure ,panel boards ,machinary exposed valve pit cover PCC foundations ,sluice valve,pump set pipe lines,etc of sewage installations complete all as specified and directed 50 Sqm
70 70 M&L and transporting of existing sewage pump motor set of any size and capacity to new location/installation using proper handling and refixing in existing position including connection and testing complete all as specified and directed . 2 Each Job
71 71 Dismantling and taking up unserviceable non clogging type centrifugal pump set of capacity 2 HP to 10 HP from foundations after disconnecting electric and water connections and transportation from site to contractor's work shop for carrying out repairs to pump sets including rewinding of motors and re- assembling, re-fixing in position, including connecting and testing complete as specified and directed.\nNotes:-\n(i) Spare parts for pumps & motors shall be measured and paid separately under respective items of this schedule.\n(ii) Transportation charges of pump sets from MES installations to contractors work shop and back is deemed to be included in the quoted rates.\n(iii) Pump sets issued for repairs / re-winding shall be returned back / re-installed at site within seven days from the date of receipt by the contractor. Any delay boyond 7 days shall be compensated through penal recovery @ Rs. 500 per day per pump set. \n(iv) Rates for minor items such as nut bolts, washers, thimbles, lugs, etc are deemed to be included in the quoted rates. 5 Each
72 72 Dismantling and taking up unserviceable non clogging type centrifugal pump set of capacity 12 to 25 HP from foundations after disconnecting electric and water connections and transportation from site to contractor's work shop for carrying out repairs to pump sets including rewinding of motors as required and re- assembling, re-fixing in position, including connecting and testing complete as specified and directed.\nNotes:-\n(i) Spare parts for pumps & motors shall be measured and paid separately under respective items of this schedule.\n(ii) Transportation charges of pump sets from MES installations to contractors work shop and back is deemed to be included in the quoted rates.\n(iii) Pump sets issued for repairs / re-winding shall be returned back / re-installed at site within seven days from the date of receipt by the contractor. Any delay boyond 7 days shall be compensated through penal recovery @ Rs. 500 per day per pump set. \n(iv) Rates for minor items such as nut bolts, washers, thimbles, lugs, etc are deemed to be included in the quoted rates. 5 Each
73 73 M&L for opening up short circuited electric induction motor, 3 phase AC 440 Volts, 2 HP to 5 HP cutting and removing the short circuited stator winding coils complete and re-winding the same with super enamelled copper wires of appropriate size as per the existing gauge including cleaning of slots, all necessary insulating materials, varnishing, drying and testing on load complete all as specified and directed 2 Each Job
74 74 M&L for opening up short circuited electric induction motor, 3 phase AC 440 Volts, 7 HP to 10 HP cutting and removing the short circuited stator winding coils complete and re-winding the same with super enamelled copper conductor wires of appropriate size as per the existing gauge including cleaning of slots, all necessary insulating materials, varnishing, drying and testing on load complete all as specified and directed 3 Each Job
75 75 M&L for opening up short circuited electric induction motor, 3 phase AC 440 Volts, 12 HP to 15 HP cutting and removing the short circuited stator winding coils complete and re-winding the same with super enamelled copper wires of appropriate size as per the existing gauge including cleaning of slots, all necessary insulating materials, varnishing, drying and testing on load complete all as specified and directed 2 Each Job
76 76 M&L for opening up short circuited electric induction motor, 3 phase AC 440 Volts, 16 HP to 25 HP cutting and removing the short circuited stator winding coils complete and re-winding the same with super enamelled copper wires of appropriate size as per the existing gauge including cleaning of slots, all necessary insulating materials, varnishing, drying and testing on load complete all as specified and directed 2 Each Job
77 77 Supply only terminal connector for 2 HP to 5 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed. 3 Each
78 78 Supply only terminal connector for 7 HP to 10 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed. 3 Each
79 79 Supply only terminal connector for 12 HP to 15 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed. 2 Each
80 80 Supply only terminal connector for 16 HP to 25 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed. 2 Each
81 81 Supply only 2 HP to 5 HP capacity PVC fan blade for motors as per the existing size complete all as specified and directed. 2 Each
82 82 Supply only 7 HP to 10 HP capacity PVC fan blade for motors as per the existing size complete all as specified and directed. 3 Each
83 83 Supply only 12 HP to 15 HP capacity PVC fan blade for motors as per the existing size complete all as specified and directed. 2 Each
84 84 Supply only 16 HP to 25 HP capacity PVC fan blade for motors as per the existing size complete all as specified and directed. 2 Each
85 85 Repairs to rotors of squirrel cage induction motor 2 HP to 5 HP by metal filling, welding / cutting & grinding, polishing to required sizes for motors complete all as specified and directed. 2 Each Job
86 86 Repairs to rotors of squirrel cage induction motor 7 HP to 10 HP by metal filling, welding / cutting & grinding, polishing to required sizes for motors complete all as specified and directed. 3 Each Job
87 87 Repairs to rotors of squirrel cage induction motor 12 HP to 15 HP by metal filling, welding / cutting & grinding, polishing to required sizes for motors complete all as specified and directed. 2 Each Job
88 88 Repairs to rotors of squirrel cage induction motor 16 HP to 25 HP by metal filling, welding / cutting & grinding, polishing to required sizes for motors complete all as specified and directed. 2 Each Job
89 89 M&L for motor end ball / roller bearing 2 HP to 5 HP with good quality grease suitable of pump sets complete all as specified and directed. 2 Each
90 90 M&L for motor end ball / roller bearing 7 HP to 10 HP with good quality grease suitable of pump sets complete all as specified and directed. 2 Each
91 91 M&L for motor end ball / roller bearing 12 HP to 15 HP with good quality grease suitable of pump sets complete all as specified and directed. 2 Each Set
92 92 M&L for motor end ball / roller bearing 16 HP to 25 HP with good quality grease suitable of pump sets complete all as specified and directed. 2 Each Set
93 93 Supply only star rubber bush coupling for motor 2 HP to 5 HP complete all as specified and directed. 2 Each
94 94 Supply only star rubber bush coupling for motor 7 HP to 10 HP complete all as specified and directed. 2 Each
95 95 Supply only star rubber bush coupling for motor 12 HP to 15 HP complete all as specified and directed. 2 Each
96 96 Supply only star rubber bush coupling for motor 16 HP to 25 HP complete all as specified and directed. 2 Each
97 97 Supply only star coupling key any size as per sample complete all as specified and directed. 6 Nos
98 98 M&L for opening up centrifugal pump sets and replacement of unserviceable pump shaft 2 HP to 5 HP complete all as specified and directed. 2 Each
99 99 M&L for opening up centrifugal pump sets and replacement of unserviceable pump shaft 7 HP to 10 HP complete all as specified and directed. 3 Each
100 100 M&L for opening up centrifugal pump sets and replacement of unserviceable pump shaft12 HP to 15 HP complete all as specified and directed. 2 Each
101 101 M&L for opening up centrifugal pump sets and replacement of unserviceable pump shaft 16 HP to 25 HP complete all as specified and directed. 2 Each
102 102 M&L for opening up centrifugal pump sets and replacement of unserviceable pump impeller brass 2 HP to 5 HP complete all as specified and directed. 2 Each
103 103 M&L for opening up centrifugal pump sets and replacement of unserviceable pump impeller brass 7 HP to 10 HP complete all as specified and directed. 3 Each
104 104 M&L for opening up centrifugal pump sets and replacement of unserviceable pump impeller brass 12 HP to 15 HP complete all as specified and directed. 2 Each
105 105 M&L for opening up centrifugal pump sets and replacement of unserviceable pump impeller brass 16 HP to 25 HP complete all as specified and directed. 2 Each
106 106 S&F in replacement of gun metal bush complete set of two as per sample for 2 HP to 5 HP complete all as specified and directed. 2 Each
107 107 S&F in replacement of gun metal bush complete set of two as per sample for 7 HP to 10 HP complete all as specified and directed. 3 Each
108 108 S&F in replacement of gun metal bush complete set of two as per sample for 12 HP to 15 HP complete all as specified and directed. 2 Each
109 109 S&F in replacement of gun metal bush complete set of two as per sample for 16 HP to 25 HP complete all as specified and directed. 2 Each
110 110 S&F in replacement of gun metal sleeves complete set of two Nos for 2 HP to 5 HP complete all as specified and directed. 2 Each
111 111 S&F in replacement of gun metal sleeves complete set of two Nos for 7 HP to 10 HP complete all as specified and directed. 3 Each
112 112 S&F in replacement of gun metal sleeves complete set of two Nos for 12 HP to 15 HP complete all as specified and directed. 2 Each
113 113 S&F in replacement of gun metal sleeves complete set of two Nos for 16 HP to 25 HP complete all as specified and directed. 2 Each
114 114 M&L for 100 mm thick PCC 1:2:4 type B-1 using 20mm graded crushed stone agregate as in floor/hard standing laid in alternate panel of size n exc 12 Sqm each , joint filled with sealing compound grade 'A' and surface finished even ,smooth without using extra cement to match with existing surface complete all as specified. 200 Sqm
115 115 Demolation of cement concrete (un-rainforced) in ground floors or pavings not exceeding 15 cm thick below or above ground level complete 8 Cum
116 116 S & F in replacement of MCCB four Pole 415 Volt AC breaking capacity 25 KA with fixed thermal and fixed magnetic setting of capacity 100 Amp conforming to IS:13947- II complete all as specified and directed. \nMake : ABB/GE /LEGRAND/SCHENEIDER/ L & T 2 Each
117 117 S & F in replacement of MCCB four Pole 415 Volt AC breaking capacity 25 KA with fixed thermal and fixed magnetic setting of capacity 160 Amp conforming to IS:13947- II complete all as specified and directed. \nMake : ABB/GE /LEGRAND/SCHENEIDER/ L & T 2 Each
118 118 Supply and Fix MCB TP 6-32 Amp ,415V,50HZ,Suitable for high inrush current load etc complete as directed . Make : ABB/GE /LEGRAND/SCHENEIDER/ L & T 2 Each
119 119 Supply and Fix in replacement MCB TP 40 Amp ,415V,50HZ, suitable for high inrush current load etc complete as directed . Make : ABB/GE /LEGRAND/SCHENEIDER/ L & T 1 Each
120 120 M&L for changing burnt /defective part of LT panel including changing of burnt /defective selector switch,PVC terminal contector,push button,burnt cu wire size up to 4 sqmm complete all as specified and directed . 1 Each Job
121 121 Supply and fix in repair 3-layer PP-R (Polypropylene random ) copolymer pipe SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having terminal stability for hot and cold water supply including all PP-R plain & brass treaded polypropylene random fitting fixed complete to walls,ceiling or infloor including all fitting such as bend tee,nipple etc complete all as specified and directed 24 RM
122 122 Supply and fix in repair PP-R (Polypropylene random) gate valve of size 50mm complete all as specified and directed. 2 Each
123 123 Supply and fix air pluger valve of size 50 mm bore as per sample. 2 Each
124 124 S&F in replacement of base plate assembly as per existing with suction/delivery of size 150 mm/100mm/80mm copouled suitable for non clogging type C/F pump 7.5HP to 25HP with necessary bolts complete all as specified and directed Note:Provision of connection withn existing suction/delivery pipe including proper alignment necessary bushing,tapers,reducesers,MS flange ,welding work,etc as required at site for commissioning of pump sets in deemed to be included in the quoted rates. 5 Each job
125 125 Supply of CRT based liquid chlorine (sodium hypochloride) solution along with stable buffer having chlorine content 13 % in 25 / 30 Ltr jar factory sealed non returnable containers complete all as specified and directed ( Make : As per approved by GE ) 5000 Ltr
126 126 Cutting and removing unwanted grass and wild growth including bushes and shrubs from the roots below ground level at Sewage installations including removing boulders from a depth not more than 25 cms below normal ground level and depositing where directed and levelling / pruning the entire cleaned area to even finish complete all as specified and directed at site. 5000 SQM
127 127 supply and fix cosmic star automatic star-delta starter for sewage motor capacity up to 15 HP complete all as specified and directed . 2 Each
128 128 supply and fix cosmic star automatic star-delta starter for sewage motor capacity from exceeding 15 HP but n exceeding 25 HP complete all as specified and directed . 2 Each
129 129 Supply and fix PVC multiport valve of size 50mm bore suitable for sewage treatment plant as per sample 1 Each
130 130 Disconneting and taking down air compressor with 7.5HP electric motor carefully from foundation manually or mechanically and transporting to workshop for repair and back, installation, refixing, reconnecting to electric and piping work the repaired compressor complete all as specified and directed by Engr-in-Charge.\nNote:- The quoted rate shall be deemed to include the cost of transportation, fixing of spare parts complete. Spare parts will be measured and paid for as supply only separately. 1 Each
131 131 Supply and fixing non return valve suitable for 7.5 HP compressor etc complete as directed. 1 Each
132 132 Supply and fixing cylinder liner suitable for 7.5 HP compressor etc complete as directed. 1 Each
133 133 Supply only piston with 'O' ring suitable for 7.5 HP compressor 1 Each
134 134 Supply only connecting rod suitable for 7.5 HP compressor 1 Each
135 135 Supply only inlet valve suitable for 7.5 HP compressor 1 Each
136 136 Supply only outlet valve suitable for 7.5 HP compressor 1 Each
137 137 Supply only gasket set suitable for 7.5 HP compressor 1 Set
138 138 Supply only piston pin suitable for 7.5 HP compressor 1 Each
139 139 Supply only safety valve suitable for 7.5 HP compressor 1 Each
140 140 Supply only pressure gauge suitable for 7.5 HP compressor 1 Each
141 141 M&L for top up activated carbon media consist of single layer of activated carbon supported by graveles and pabbles at bottom,coconut shell carbon and coal based carbon used ,adsorption capacity up to 90% chlorine ,colour and odour removal 85 to 90% , top up up to 40 cm and maintain media density 500-700 kg/m3 and as directed 1 CUM
142 142 M&L for top up dual media consist of silica sand (16-32 mm mesh) and anthracite( 0.6-1.2mm) provide more area & efficient filteration ,supported by gravels and pebbles at bottom, topup silica sand up to 10 Cm thickness and top up anthracite up to 10 cm thickness to maintain the filteration level up to 40 microns complete and as directed 0.4 Cum
143 143 M&L for painting of steel tubuler HT poles any type complete incl flat iron clamps, D clamps, Stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface marking with alternate white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint andalso including numbering of poles with white paint are located on different locations in HT over head lines complete all as specified and directed 114 Each
144 144 M&L for painting of steel tubuler HT two poles any type complete incl flat iron clamps, D clamps, Stay clamps, earth wire clamps, bracing, cross arm,angles with two coat aluminium paint including prepration old painted surface marking with alternate white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint andalso including numbering of poles with white paint are located on different locations in HT over head lines complete all as specified and directed 20 Each
145 145 All as per item No 144 herein before but three pole structure 10 Each
146 146 All as per item No 144 herein before but four pole structure 10 Each
147 147 M&L for painting of steel tubuler LT poles any type complete incl flat iron clamps, D clamps, stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint incl prepration old painted surface marking with alternator white and black strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint, numbering of poles with white colour are located on different locations in LT over head lines complete all as specified and directed. 300 Each
148 148 All as per item No 147 here in before but two pole structure 20 Each
149 149 M & L for painting of steel cross arm, bracing supports of HT PCC poles any type incl flat iron clamps, D clamps, stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint incl prepration old painted surface marking with alternator white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint, numbering of poles on HT overhead line complete all as specified and directed. 150 Each
150 150 All as per item No 149 herein before but two pole structure 12 Each
151 151 All as per item No 149 herein before but three pole structure 5 Each
152 152 All as per item No 149 herein before but four pole structure 12 Each
153 153 M&L for painting of steel cross arm, bracing supports of LT PCC poles any type incl flat iron clamps, D clamps, stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint incl prepration old painted surface marking with alternator white and blackstrips 30 cm height 5 Nos strips with two coat of synthetic enamel black paint, numbering of poles on HT overhead line complete all as specified and directed. 300 Each
154 154 All as per item No 153 herein before but two pole structure 12 Each
155 155 All as per item No 153 herein before but three pole structure 2 Each
156 156 All as per item No 153 herein before but four pole structure 10 Each
157 157 M&L for disconnection of electrical connection from LT panel board for cleaning of rusted parts with scrubbing, removing/ cleaning of unwatned materials inside and outside of the panel, replacing of rusted/burnt cable with new lugs , replacing of unserviceable lock, taking down and refixing of front and back side panel doors by providing mild steel butt hinges 75 mm with welding for proper opening and closing, replacing unserviceable rubber beeding, replacement of ammeter/voltmeter range 0-500 Amp , indicator lamp LED ,replacement of control cables of panel with 1.5 Sqmm FRLS copper cable standred , replacement of broken frame made of angle iron 50x50x6 mm thick & suppoting MS frame including applyiing two coats of synthetic enamel paint over a coat of red oxide primer , Making good brokn /dameged PCC foundation and Panel inetrnal & externally completely painted with two coats of synthetic enamel paint with spay gun ,tint as approved by the GE and testing of LT panel etc complete all as specified and directed by Engr-in-charge. Note :- The items/tools/welding machine requied at site included in the quoted rate. 10 Each Job
158 158 M&L for disconnection of electrical connection from LT busbar box for cleaning of rusted parts with scrubbing, removing/ cleaning of unwatned materials inside and outside of the panel, replacing of rusted/burnt with existing lugs and removing of cracked cable by cutting/scrubbing from the looping, replacing of unserviceable locks, fixing of front and back side panel doors with hinges through welding for proper opening and closing, replacing unserviceable beeding,repair/replacement of MS structure including welding, painting and making and matching with existing surface, cleaning of bushes/scrubs/grass around 1.5 radius, repair the disturbed PCC foundation making good condition, painting of one coat of existing colour to match the panel and refixing of cables and testing & commissioning of LT panel etc complete all as specified and directed by Engr-in-charge. Note :- The items/tools/welding machine requied at site included in the quoted rate. 12 Each Job
159 159 M&L for cleaning of mild steel grill, window, doors etc inside and outside of the installation/power house with proper scrubbing for removal of rusted materials and making paint of one coat synthetic enamel of existing color through spray paint after preparation of surface neat and clean etc as per entire satisfaction of Engr-in-Charge complete all as specified and directed 10 Each Job
160 160 M&L galvanised steel tubing 80 mm bore light grade with GI fittings in trenches under road / along pole / wall for cable protection complete all as specified and directed. Make: Jindal/Prakash Surya/Tata 30 RM
161 161 Laying connecting and testing& commissioning underground cable, PVC insulated, armoured heavy duty electric cable with aluminium conductor 35 - 400 Sqmm 3.5 core 1100 volts grade cross-sectional area incl taking down/upof existing old cables complete directed by Engr-in -charge. The rate includes the connection of cable by providing copper thimbels at two ends of cables properly. Note : Cables will be issued under Sch 'B' for laying only . 750 RM
162 162 M&L for taking up/down and refixing of existing old steel tubular LT poles any type by demolition of old PCC of any type from different locations without any damage of the poes/properties including demolition of cross arms, staywire, clamps of any type, ACSR conductor/cables of any type,insulators any type, GI brackets of any type, security lights of any type all as specified and directed by Engineer in Charge. The rate includes the excavation required for taking down/up & demolition of poles also shifting of the poles for refixing of poles as disired for refixing. Note : Excavation and PCC required for refixing of poles shall be measued and paid separately. 25 Each
163 163 Erecting old steel tubular swaged pole 9.0 mtr long, in true vertical position and exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint, numering of poles as directed complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. 25 Each
164 164 M&L for dismatling/taking down of HT and LT side connections from existing transformer of 400 KVA including shifting of transformer from existing platform base for re construction of platform including shifting of MS frame of any size/shape and connecting of transformer to HT/LT connections for restore supply. Note : All T&P required for placing the transformer on its original location and sfaety measurers deemed to be included in unit rate quorted the tnederer. 1 Complete Job
165 165 M& L for MS fabrication work made out of structural steel sections as in frame work including MS angles/flats/plain sheets of appropriate guage, cut to size and made to appropriate shape suitable for transformer shead/gates including nut bolts and washers in any size, welding bracing work and bending cold or hot drilling holes for bolts in any shape or size as required including one coat of primer and two coats of synthetic enamel paint to the entire steel surface including taking down of the existing for modifying as per requirment at site all are as specified and directed. 250 Kg
166 166 M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius built in CM (1:4) as in foundation of equipment, platform, ramp,cable ducts, supporting pillars of pipes incl demolistion of existing brick work built in cement mortar including excavation for foundation at minimum of 45 cm depth from ground level complete all as specified and directed. 4 Cum
167 167 M&L for plastering in CM (1:4) 10 mm thick on fair faces of brick work or concrete surface/ cable duct / floor complete all as specified and directed. 20 Sqm
168 168 M&L for preparation new plastered surface sof walls and applying two of cement based paint over a coat primer complete all as specified and directed. 20 Sqm
169 169 M&L for earthing complete including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead 4.0 mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 40 mm dia. light grade pipe and watering pipe shall be 20 mm ore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc. complete all as directed. Note : The conctrete pit shall be PCC 1:3:6 type C1, 40 mm thick PCC slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No.5 of MES SSR Part-1 (ii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbows etc shall be deemed to included in the quoted rate. 12 Each
170 170 M&L for cable path indicator made out of MS sheet complete duly embossed LT cable MS sheet of 6 mm thick and 6 cm dia duly fixed by means of nut bolts washer on angle iron frame of size 25x25x3mm length 75 cm long size fixed on and including PCC1:2:4 block of size 150 x 150 x 300 mm depth 45 cm above ground level and 30 cm below ground level duly painted two coats of red oxide and two coats of enamelled paint complete all as specified and directed. Note - cost of earth work for installation of path indicator included in the quoted rate. 185 Each \nJob
171 171 M&L for aluminium conductor, steel reinforced (ACSR) of any size/description on LT poles/lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing incl taking down complete all as specified & directed. Note- Old spacers obtained from taking down of ACSR conductor shall be reused and fixed as directed. 2 Qtl
172 172 S & F cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint incl taking down complete all as specified and directed. 4 Qtl
173 173 S & F incl stringing GI continuous GI earth wire of size 4 mm / 3.15 mm dia on LT poles as in cradle guards / earth wires, binding including taking down complete all as specified & directed. 2 Qtl
174 174 S&F danger notice plate of 1.6 mm thick mild steel sheet vitreous enamaled white, with letters, figures and conventional skull and bones in post office red colour duly painted and written with enamelled paint fixed with and including MS clamps, bolts and nuts of approved size for LT, 20x15 cm size complete all as specified and directed. 20 Each
175 175 S & F in replacement of pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut,1100 volt grade 100 mm height and 65 mm dia suitable for working pressure incl taking dwon complete all as specified and directed . 60 Each
176 176 S & F in replacement of shackle type 75 mm height and 90 mm dia insulator, porcelain, vitreous, white, brown or green incl galvanised mild steel strap 31 mm X 3 mm, insulator bolts 12 mm dia with suitable washers and nut, suitable for working pressure upto 1100 volt & including taking down complete all as specified and directed 50 Each
177 177 M&L for stay assembly of MS galvanised stay plate 230mm X 230mm X 6mm thick MS galvanised tay rod 20 mm dia with nut 100 cm long MS galvanised stay bow 40 cm long and 14 mm dia with 2 Nos galvanised thimble with and incl all fittings all as specified in SSR 2009 Part I icomplete all as specified and directed. Note - Excation, earth work, PCC foundation etc, loop type insulator shall be measured and paid separately. 8 Each
178 178 M&L for galvanised stay strand 7/ 4 mm complete all as specified and directed. 1 Qtl
179 179 M & L for loop type insulator large size with overall demensions 140 mm clearance of hole 25.5 mm complete all as specified and as directed. 8 Each
180 180 M&L for connecting,testing and commissioning of LT UG cables, LT panels, busbar boxes at zone-12 Sub stn C to indipendent married accomodation including connecting of existing panel to main incoming LT panel through copper lugs and check servicebility of cable, panels, busbar boxes etc.The quoted rate includes rate of copper thimbels required at site, necessary excavation of cables as required at site, repair of panels/busbar boxes such as welding,painting replacement of control cables etc. The rate also includes necessary excavation for for laying of cables if required at site, road cutting, repair of road, demolition of PCC, repair of PCC, and necessary PCC work etc. 1 Each Job
181 181 M&L for connecting,testing and commissioning of LT UG cables, LT panels, busbar boxes at BO's line/Officer enclave Sub stn to indipendent married accomodation including connecting of existing panel to main incoming LT panel through copper lugs and check servicebility of cable, panels, busbar boxes etc.The quoted rate includes rate of copper thimbels required at site, necessary excavation of cables as required at site, repair of panels/busbar boxes such as welding,painting replacement of control cables etc. The rate also includes necessary excavation for for laying of cables if required at site, road cutting, repair of road, demolition of PCC, repair of PCC, and necessary PCC work etc. 1 Each Job
182 182 M&L for repair/replacement & testing commissioning of outdoor type bus bar panel weather proof MS cubical panel board of size 1 mtr x 1 mtr 40 cm,TPN bus bar of 125 Amp capacity including one coat of redoxide and two coat of enamel paint powder coated, mounted on channels and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as directed. 5 Each Job
183 183 M&L for repair of LED street light/flood light of capacity 45 watt to 70 watts including replacement of unserviceble/burnt drivers,AC/DC converters of suitable capacity diods,capacitors, LED bulbs,resistors,relays, connectors, soldering of connections as per requirement, replacement of connecting cables, testing and commissioning including dismantling from existing pole and refixing the same place . Note: The quoted rate includes cost of all spares parts /fixtures as required to make the light functional . 100 Each
184 184 M&L for repair of LED street light/flood light of capacity 75 watt to 150 watts including replacement of unserviceble/burnt drivers, AC/DC converters of suitable capacity, diods,capacitors, LED bulbs,resistors,relays, connectors, soldering of connections as per requirement, replacement of connecting cables, testing and commissioning including dismantling from existing pole and refixing the same place . Note: The quoted rate includes cost of all spares parts /fixtures as required to make the light functional . 75 Each
185 185 M&L for repair/replacement of 8 KW, single phase automatic street light timer switch for automatic switching on/off street light based on lux level of nature light, consisting of sensor, overload protection fuse gear, power contactor & MCB of 63 Amp capacity, terminal blocks for cable entry & control unit enclosed in pole/wall mountable enclosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 66, with universal olck and key arrangement completeall as specified and as directed.(The rate includes 01 contact of same capacity of above issue as spare). Make :- Kakatiya energy system pvt ltd Cat No.swadeep-66 8kw1P 3 Each Job
186 186 M&L for replacement of aluminum bas bar of differnet sizes at LT panes at various locations including taking down of the exisiting u/s bus bar after diamantling of connections and replacing new bus bar,testing and commissioning of the panel. The capacity of the bus bar must be 1.5 times capacity of incoming MCCB/capacity as per installed at site, aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator .The rate includes rate for necessary frame work in bus bar, rate of insulators. nut bolts,connecting copper lugs etc . 20 Kg
187 187 M&L for Reinforced cement concrete (normal mix) type B0 1:2:4 (12.5 mm graded aggregate) for duct slab for cover of ducting including demolition of old damaged duct cover all as directed by Engr incharge. 1 Cum
188 188 M&L for 8 mm and over using TMT bars cut to length bent to shape as required including cranking bending spirally for hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securig with clips etc complete. 75 Kg
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail