Water Resources and Irrigation Government Departments Closing in 0 days TDR #22556208

Improvement Of Lwss Tullah Including House Hold Connection To In Tehsil Lad Bharol Distt Mandi Sh C O Intake , Pump House , Main Storage Tank , P Laying , Jointing And Testing Of Rising Main , Supply Erection Of Pumping Machinery Gaseous Chlorina

Issued by Government Departments · Lad Bharol, Himachal Pradesh
Tender Value
61.90 Lakhs
Estimated cost
Bid Submission
02 Dec 2019
0 days left
EMD
94405
Bank guarantee accepted
Document Fee
800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lad Bharol → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Improvement Of Lwss Tullah Including House Hold Connection To In Tehsil Lad Bharol Distt Mandi Sh C O Intake , Pump House , Main Storage Tank , P Laying , Jointing And Testing Of Rising Main , Supply Erection Of Pumping Machinery Gaseous Chlorination

BOQ

Name of Work:Improvement of LWSS Tullah including house hold connection to in Tehsil Lad Bharol Distt Mandi (SH:-C/o Intake , Pump house , Main storage tank, P/Laying, Jointing and testing of Rising Main , Supply & erection of pumping machinery Gaseous chlorination plant and automation).
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Cutting in earth work in all kind of soil such as pick work, jumper work,chiselling work and then disposing of all surplus excavated with in all lead and lifts.and as per the direction of Engineer-in-charge.255Cum
22Excavation in foundation and trenches in earth work,lifts up to 1.50 meters atacking the excavated soil not more than 3 meters clear from the edge of the excavation and then returning the stacking soil in 15cm .layers, when required in to plinths sides of foundations etc, consolidating each deposted layer by ramming and watering and then deposing of all surplus excavated earth as directed with in a lead of 20 metres in all respect with in all leads and lifts as per the direction of Engineer-in-Charge.2063.51Cum
33Providing and laying cement concrete 1:4:8 (1cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of from work in foundation and plinth complete in all respect with in all leads and lifts and as per the entire satisfaction of Engineer-in Charge.5.87Cum
44Providing and laying cement concrete 1:3:6 (1cement:3 sand:6 graded stone aggregate 40mm nominal size) and curing complete excluding cost of from work in foundation and plinth complete in all respect with in all leads and lifts and as per the entire satisfaction of Engineer-in Charge.6.16Cum
55Providing and laying cement concrete 1:5:10 (1 cement:5:sand:10 graded stone aggregate 40mm nominal size) with 15% plum and curing complete excluding cost of form work in retaining wall/breast wall, the size of plum shall usually be 150mm to 300mm as per the direction of Engineer-in-Charge..42.08Cum
66Providing and laying cement concrete 1:1.5:3 (1cement:1.5 sand : 3graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work and re-inforcement for reinforced concrete work in:-
76.01Foundation , footing basis of columns & the like and mass concrete complete in all respect and as per the direction of Enginer-in-Charge9.64Cum
86.02Wall (any thickness but not less than 0.1 m thickness) attached pillasters, buttresses, plinth and string courses, etc. from top of foundation level upto floor two level complete with in all leads and lifts as per direction of the Engineer-in-Charge.13.98Cum
96.03Suspended floor ,roofs, lendings and shalves and thier suports balconies,beem griders and bressumers and cantiliver upto floor two level complete with in all leads and lifts as per direction of the Engineer-in-Charge.21.39Cum
107Providing tor steel reinforcement for R.C.C. work including bending,binding and placing in position complete upto floor two level in all respect complete with in all leads and lifts as per the direction of Engineer-in-Charge.4528.8Kg
118Providing form work of steel plate 3.15mm thick planking so as to give a rough finish including shuttering, centring, shuttering and propping hight of propping and centring below supporting floor to ceiling not exceeding 4 mtrs and removal of the same for in-situ reinforced concrete and plain concrete work in lintels, beams etc. including all leads and lifts in: and as per the entire satisfaction of Engineer-in Charge.
128.01Vartical surface such as walls (any thickness) portion and the like including attached pillers,buteress plinth and staircases and the like.295.81Sqm
138.02Flat surfaces such as soffits of suspended fioors roofs landing and the like . Floors etc up to 200mm in thickness. complete in all respect and as per the entire satisfaction of Engineer-In-Charge.86.64Sqm
148.03Edge of slabs & Breaks in floors & walls under 20 cm wide complete in all respect and as per the entire satisfaction of Engineer-In-Charge.55.95Rmt
158.04Beams ,cantilevers, girders and lintels up to floor to level with in all leads and lift complete with in all leads and lifts as per direction of the Engineer-in-Charge.25.73Sqm
168.05Sloping of batterings surfaces etc.61.35sqm
179Providing form work of ordinary timber plankings so as to give a rough finish including centring, shuttering ,strutting and propping etc. height of propping and centring below supporting floor to ceiling not exceeding 4 mtr. & removal of the same for insitu reinforced concrete and plain concrete work in : Dome roof of tank of any shape and size.38.65Sqm
1810Providing and fixing man hole cover with locking arrangement as per approved by I&PH deptt. 116 kg2Each
1910.01Providing and fixing man hole cover with locking arrangement as per approved by I&PH deptt. 38kg.1Each
2011Providing and fixing of GMS tube of following dia in walls, floors etc. including tube fittings and making the walls, floors etc. Pipe light grade for inlet,outle and over flow.
2111.01Inlet,Outlet and Scour pipe 100mm dia.15Rmt
2211.0265 mm18Rmt
2312Providing and Fixing of double flanged suing type Cast Iron Sluice Valve of leader/ Kirlosker / Kilburn make and of following dia with flange table - 17 Class - 125 (PN - I) capable of with standing the normal sheet pressure as per IS-5312-1984 with up to date amendements complete in all respect as per the satisfaction of Engineer-in-Charge. 65 mm dia3Each
2413100 mm dia3Each
2514Providing and fixing 1.80m high barbad wrie fencing with angle iron post 2.50m C.C with 9 horizental row and 2 diagonal rows of barbad wire embendded in C.C.1:4:8.as per the satisfaction of Engineer-in-Charge. 65 mm dia84Rmt
2615Providing and laying cement concrete 1:6:12 (1cement:6 sand:12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete with in all leads & lifts as per direction of Engineer-in-Charge.17.1Cum
2716Random rubble masnory/ polygonal rubble masonry (uncoursed/brought to courses) with hard stone of apporved quailty in foundation & plinth including levelling up with cement concrete 1:6:12 (1Cement :6 sand :12greded stone aggregate) in CM 1:6 (1cement : 6sand) complete with in all leads and lifts.33.24Cum
2817Boulder filling under floor complete with in all leads and lifts.7.15Cum
2918Brick work using common burnt clay building bricks in super structure above plinth level upto floor two level in cement mortor 1:4 ( 1 cement : 4 sand ) Ist class brick complete with in all leads and lifts.34.93Cum
3019Providing wood work in frames of door and window 2nd class Deodar wood with in all leads and lift,carrige of material and other incidental charges complete in all respect as per the direction of Enginer-in-charge0.605Cum
3120Providing and fixing panneled glazed or panneled and glazed shutters for doors, windows and clerestory windows, including black enamelled iron butt hinges with necessary screws 40 mm thick 2nd class deodar wood complete with in all leads & lifts as per direction of Engineer-in-Charge.17.58Sqm
3221Providing & fixing M.S. grills of required pattern in wooden frame of window etc. with M.S. flats, square or round bars with round headed bolts and nuts by screws plain grill complete with in all leads and lifts..1.04Qtl
3322Cement concrete flooring 1:2:4 (1cement : 2sand : 4 graded stone aggregate 20mm nominla size) laid in one layer finished with a floating coat of neat cement 40mm thick complete with in all leads and lifts.48.23Sqm
34236mm thick cement plaster to ceiling in cement mortar 1:3 (1 cement:3 sand)77.83Sqm
352415 mm cement plaster in single coat on rough side of brick/ concrete/ stone wall for interior plastering upto floor two level including arrises internal rounded angles, chamfers and or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortor 1:6 (1cement:6sand) complete with in all leads & lifts as per direction of Engineer-in-Charge.157Sqm
3625Flushing pointing on brick work with cement mortor 1:3 (1cement :3sand).97.97Sqm
3726White washing with lime on un-decorated wall surfaces (with two coats) to give an even shade including thoroughty brooming the surface to remove all dirt,dust,mortor dirt and other foreign matter.198.2Sqm
3827Applying priming on new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil, grease, dust and other foreign matter, sand preparing and knotting. Ready mixed paint brushing wood primer pink.39.25Sqm
3928Painting two coats ( excluding priming coat ) on new wood and wood based surfaces with enamel paint to give even shade including cleaning the surface of dust and other foreign matter, sand preparing and stopping with enamel paint other than white.39.25Sqm
4029Providing and fixing oxidized M.S. sliding dooor bolts with nuts and screws etc. complete 300x16mm complete with in all leads & lifts as per direction of Engineer-in-Charge.3sqm
4130Providing and fixing anodised M.S. Tower bolts (Barrel type) with necessary screws etc.complete .
4230.01250 x 10 mm.5Each
4330.02150 x 10 mm.27Each
4431Providing and fixing Oxidized M S Handle with necessary screws etc complete. 125 mm22Each
4532Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement: 3sand:6graded stone aggregate 20mm nominal size) including finishing the top surface of concrete smooth.17.73Sqm
4633Providing under layer for plinth protection of 75mm thick (unconsolidated) bed of dry brick /stone aggregate 40mm nominal size) well remmed and consolidated and grouted with fine sand including preparation of ground.23.64Sqm
4734Half brick masonry in common brunt clay building bricks in cement mortor 1:4 ( 1 cement:4 sand ) 2class bricks complete with in all leads and lifts.19.18Sqm
4835Providing and laying cement concrete 1:2:4 (1cement:2 sand:4graded stone aggregate 20mm nominal size ) and curing excluding cost of form work and reinforcement for reinforced concrete work in:-
4936Suspended floor,roofs, landings,shelves and their supports balconies, beams,girders, bressumers and centilevers upto floor two level complete with in all leads & lifts as per direction of Engineer-in-Charge.1.19Cum
5037White glazed tiles 6mm thick flooring cement mortar 1:3 (1cement:3 sand) complete with in all leads and lifts.2.16Sqm
5138White glazed tiles 6mm thick in skirting risers of steps and dado 12mm thick cement mortar 1:3 (1cement:3 sand) complete with in all leads and lifts.3.06Sqm
5239Distempering (Two coat) with oil bond wash able distemper of approved brand and manufacture and of required shade on undecorated wall surfaces to give and even shade over and including a priming coat with distepter primer of approved brand and manufacture after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even and sand papered smooth. Priming coat with distemper primer in all leads and lifts.36.63Sqm
5340Providing and fixing automatic flushing cistern with a pair of C.I. or M.S. brackets complete with fittings including Syphonic apparatus, mosquito proof lid, unions and coupling for connections with inlet, outlet and overflow pipes including cutting holes and making food the same (overflow pipe to be measured and paid for separately) Viterous china 5 ltrs. capacity.1Each
5441Providing and fixing vitreous China wash, down water closet ( European type WC pan) with integral \"P\" or \"S\" trap including jointing the trap with soil pipe in cement mortar 1:1(1cement:1 Sand)( Seat and cover to be measured and paid for seperately) Anglo Indian ( Universal Closet) complete in all respect in all leads and lifts and to the entire satisfaction of Engineer-in-charge .1Each
5542Providing and fixing 100 mm size P or S trap for water closet ( Squatting Pan) including jointing the trap with the pan and soil pipe in cement mortar 1:1 ( 1cement : 1 sand) Sand cast iron1Each
5643Providing & fixing viterious china wash basin with single hole for pillar tap with CI or MS bracket painted white including cutting hole including good the same excluding fitting Cera sanitary work (cornet) white 550x400 white1Each
5744Providing and fixing viterious china padestral for wash basin complete recessed at the basic for reception of pipe and fittings Cera sanitary work (carnet) white (Viterious China in White Colour)1Each
5845Providing and fixing water storage tank Sintex having of capacity of 500 ltrs. with necessary fitting i/c over flow pipe, Scour pipe etc. inlet and outlet and inside paint of approved quality complete including hoisting complete in all respect.1Each
5946Providing and fixing on wall face PVC (D - Plast) rain water pipes of working pressure not less 4.5 Kg/Sqcm including fitting the joints with approved adhesive complete with in all leads , lifts and carriage of materials.110 mm nominal bore.8Rmt
6047Providing and fixing on wall faces PVC door bend (D-Plast) with oval access door, insertion rubber washer 3 mm thick bolts and nuts ISI marked complete including fixing with approved adhesive complete.75 mm nominal bore.6Each
6148Providing and fixing to wall ceiling and floor galvanised mild steel tubes (Medium grade) tube fittings and clamp including making good the wall ceiling and floor in all leads and lifts.) 15 mm nominal bore10Rmt
6249Providing and fixing full way wheel valve 15 mm dia Gun metal.2Each
6350Providing and fixing C. I cowl 100 mm dia .1Each
6451Providing and fixing brass bib tap (superior qualityor heavy type) 15 mm dia.2Each
6552Providing & Fixing CP Brass Soap Dish with CP breckets fixed to wodden plugs with CP brass screws complete in all respect in all leads and lifts.1Each
6653Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light p
6753.01Group -C5Rmt
6854Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper condu
6954.01i) 2x1.50 Sq. mm.46Rmt
7054.02ii) 2x2.50 Sq. mm.41Rmt
7155(a) Supplying and fixing 3 pin 5/6 amps. Socket outlet on the exists switch box/covers including connections etc. as required.11Each
7255.01(b) Supplying and fixing 2 way 5/6 amps. Tumbler/piano type switch on the existing switch box on the switch box/cover including connections etc. as required.3Each
7356(a) Supplying and fixing 3 pin 15/16 amps. Socket outlet on the exists switch box/covers including connections etc. as required.3Each
7456.01(b) Supplying and fixing 15/16 amps. Tumbler/piano type switch on the existing switch box on the switch box/cover including connections etc. as required.3Each
7557Supplying and fixing wooden box of following size (nominal) on surface or recess with suitable size of phenolic laminated sheet cover of in front as required.
7657.01(a) 229 mm.x 102 mm.x 60 mm. deep1Each
7757.02(b) 203 mm.x152 mm.x 60 mm. deep3Each
7858Providing and Supplying CFL 1 x 23 watt of reputed make in all leads and lifts.3Each
7959Providing and Supplying of CFL 1 x 5 watt in all of reputed make in leads and lifts.3Each
8060Supplying and Fixing 5 Amps to 32 Amps rating, 240 Volts, L series miniature circuit breaker of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required Cat - A. (Single Pole)6Each
8161Providing , laying,jointing ( by way of circumfrential flanged joints of various flanges by electrical arc welding ) and testing of Steel pipes of following dia meters confirming to ISO 3183-2007, pipe grade L290 (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
8261.01RD 0 to 300 dia 100 mm wall thickness5.20mm F.Table 34 MSERW L-210300Rmt
8362Providing , laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of Steel pipes of following dia meters confirming to ISO 3183-2007, pipe grade L390 or X-56 (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
8462.01RD300 to1000 dia 80 mm wall thickness4.8mm700Rmt
8563Laying,jointing ( by way of circumfrential flange jointing of various flanges by electrical arc welding ) and testing of Galvanised mild steel tubes (GI Pipes) of following dia meters confirming to BIS 1239-2001 (latest with upto date amendments) having wall thickness as per code with bevelled / plain ends in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and specials made form the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
8663.0165 mm dia , (Medium class) IS 1239 Flange table-5350Rmt
8764Laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of Galvanised mild steel tubes (GI Pipes) of following dia meters confirming to BIS 1239-2001 (latest with upto date amendments) having wall thickness as per code with bevelled / plain ends in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and specials made form the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
8864.0180 mm dia , (Medium class)1900Rmt
8965Pumping machinery. Ist stage ( Raw water stage)
9065.01Supply of submersible raw water pump set of reputed make such as KSB/Calama/SU/joinsion conforming to latest relevant BIS code. The pump should be fitted with free flow impellers of suitable alloys as per BIS 8034-1978 latest suitable for lifting raw water having 6000 PPM turbidity, grease packed bearings and shaft with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specification. The pump shall be directly coupled to submersible squirrel cage electrical induction motor of same make conforming to BIS 9283-1979 (latest with up to date amendments) totally dust and water proof for submersible duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical load with minimum bear and tear. It should also be fitted with a device to take up expention of water with heating of motor. The pump should include water level guard,errection clamps,cable clips and depth gauge etc. and suitable for opration in data given3set
9165.02Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens cnonforming to \n BIS-8544-1979 latest with up to date ammendments for squirrel\ncage (make to be specified by the tenderers) mounted on panel board with\nmagnetic type over load release & dashpot,time lag,under voltage release with initial \noil filling .\n2each
9265.03Providing & fixing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angale iron post of suitable height and size ISA 40x40x6mm duly paintedcomprising and capable of mounting the following accessaries with all internal \n electric connections. The drawing of panel board shall be subject to approval of \n Engineer in charge.\n1each
9365.04Ammeter AC supply,100 mm circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 1248-1983 latest withup to date ammendments.2each
9465.05Voltmeter AC supply,100 mm circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 4064-1978 withup to date ammendments.1each
9565.06ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and havingcapacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.2SET
9665.07Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.1each
9765.08MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in comming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.\n1each
9865.093 phase indicating lamps complete with toggle switches for individual motors \n conforming to BIS 3452 part I & II latest with up to date ammendments.\n1SET
9965.1Earth leakage circuit breaker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977with upto date ammendments and of suitaible range with which should have control box, oprating handel and trip/reset bush button on/ off indicators, re-indicating off spring conditionof the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breakeron occurance of earth fault on/ of breaker load side.\n1each
10065.11Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition)/recommendations.\n2each
10165.12Suitable three phase voltage monitor relay with all protections & usual indicators with electricalsirens against single phasing,no voltage,high voltage & overloading & phase voltage difference1each
10265.13Change over Switch of reputed make & suitable capacity1each
10365.14Single phase preventor of reputed make & suitable capacity1each
10465.15Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ Kartar of reputed make of suitable size cast iron PN-1 double flanged sluice valve having size equal to due step higher than delivery of pump and capable of with standing nominal seat pressure of 10 kg/cm^22each
10565.16Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar of suitable size cast Iron PN-1 double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 10 kg/cm^2\n2each
10665.17Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar of suitable size cast Iron double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure of 10 kg/cm^2\n1each
10765.18P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICCmake from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.. \n10Mtr
10865.19P/L suitable size copper PVC insulated armoured power three core cable conformingto BIS 1554(part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICCmake from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. \n20Mtr
10965.2P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.\n1JOB
11065.21Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.2Each
11165.22Supply of standarad make 100mm dia circular dial pressure gauge of suitable range Fiebeg/ Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.\n2each
11265.23P/L column pipe considering site requirements,NPSH required & available & common header having area equal to two times the area of delivery branch of pumpincluding tapers,flanges,rubber gaskets,3mm thick as per BIS-2712-1978 nuts & bolts as per1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times thetotal presure indicated in item no. 1e(ii).\n45Mtr
113662ND STAGE
11466.01Supply of horigental spindle, vertical split casing single/Multistage centrifugal / reciprocating pumps of standarad make such as KSB/Mather & Platt/Jyoti/Kirloskar/WASP /Best & Crompton conforming to BIS latest with upto date ammendments read with BIS 9137-1978 or latest to handle clear water having turbidity 500PPMwith impellers ,casing ring& saft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlosker/ NGEF/Crompton/Siemen/Joti/ABB/Marathan approved by the department .slip ring/ squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below.2SET
11566.02Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens cnonforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipriing motor (make to be specified by the tenderers) mounted on panel board withmagnetic type over load release & dashpot,time lag,under voltage release with initial oil filling Note:- Star delta -starter upto 37.5 KW ,ATS between 37.5 KW to 50 KW and Stater rotor starter with slipring motor.\n2Each
11666.03Providing & fixing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angale iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internalelectric connections. The drawing of panel board shall be subject to approval of Engineer in charge.\n1Each
11766.04Ammeter AC supply,100 mm circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 1248-1983 latest with up to date ammendments.\n2Each
11866.05Voltmeter AC supply,100 mm circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 4064-1978 with up to date ammendments.\n1Each
11966.06ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and havingcapacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.2SET
12066.07Busbar chamber having 3 copper bars of suitable rating for full length equal to wirdth of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.\n1Each
12166.08MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in comming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.1Each
12266.093 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.\n1SET
12366.1Earth leakage circuit breaker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977with upto date ammendments and of suitaible range with which should have control box, oprating handel and trip/reset bush button on/ off indicators, re-indicating off spring condition\n of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breakeron occurance of earth fault on/ of breaker load side.\n1Each
12466.11Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition)/recommendations.2Each
12566.12Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing,no voltage,high voltage & overloading & phase voltage difference1Each
12666.13Change over Switch of reputed make & suitable capacity1Each
12766.14Single phase preventor of reputed make & suitable capacity1Each
12866.15Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast steel double flanged ASA-300 sluice valve having size one step higer to delivery of pump and capable of with standing nominal seat pressure of 52 kg/cm^2 class ASA-300\nNOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend- -ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure )\n 104 Kg/Cm2as per BS 1414(API 600) \n2Each
12966.16Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast steel ASA-300 double flanged swing check type reflux valve having bye pass arrangement & size one step higher to delivery of pump for withstanding nominal seat pressure of 52 kg/cm^2class ASA-300\n NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2)as per BS 1414(API 600) .\n2Each
13066.17Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size Cast Steel ASA-300double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main ie 65mm diafor withstanding nominal seat pressure of 51 kg/cm^2class ASA-300NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then the\n sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2)as per BS 1414(API 600) .\n1Each
13166.18Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar of reputed make of suitable size cast iron flanged sluice valve confirming IS 780, size equal to dia of suction pipe ; PN1 providedwith hand wheel/Cast iron Cap.2Each
13266.19P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICCmake from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories suchas thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.. \n15Rmt
13366.2P/L suitable size copper PVC insulated armoured power three core cable conformingto BIS 1554(part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICCmake from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipessolder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.10Rmt
13466.21Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.\n2Each
13566.22Supply of standarad make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conformingto BIS 3624-1987 latest with up to date ammendments2Each
13666.23Erection of all items except item no. 5 (a) to (c ) i/c cost of tees,bends\n tapes & any others fittings required as per site conditions and as per direction of Engineer-in -Charge.\n1Job
13767Gaseous chlorination Plant at WTP
13867.01Supply, installation, Commissioning and testing of vaccum operated, pressure feed gaseous chlorinator of Toshcon jesoul capital make for chlorination of water by direct feeding of the following components in all leads and lifts as specified below.1Job
13967.02Providing installation & commissioning of gaseous type fully vaccume chlorination system having 0-1.0 kg per hour chlorine gas feeding capacity of PENWALT (USA) / ECOCHLOR (USA) /ENCHLOR (USA)/Jasco (USA) make the system shall have vacuum regulator with inbuilt Maesuring Glass with dose rate adjuster, Vacuum ejector Non Return valve 4.0 m long PE tubing (As Vacuum and Vent tubing), 32mm Spanner, Ammonia Solution etc, in all leads and lifts and to the entire satisfaction of Engineer- in-charge
14067.03Chlorine Gas Injector2Job
14167.04Providing installation & commissioning single phase monobloc pump 1.5 to 2.0 HP of required discharge capacity with Motor og Kirloskar/Crompton. Greaves make with common steel fabricated base frame duly grouted at site including starter and cabling including all leads and lifts and as per satisfaction of Engineer- in -charge.2Job
14267.05Providing installation & commissioning of ISI marked PVC pipe & fittings ball valves,Lead washers, O-Rings, G.I. pipe and fitting for installation and grouting of steel for ejector of gaseous type cholorination system complete in all respect including all leads and lift and as per entire satisfaction of Engineer-in-charge.1Job
14367.06Providing & installation of gas filling chlorine gas cylinder of 100 kg capacity as per BIS standard duly certified by the petroleum and explosive safety organization Govt of India for the scheme including all leads and lifts and as per entire satisfaction of Engineer-in-charge.4Cylinder
14467.07Providing and Supplying of Safety kit.1Set
14568Automation
14668.01Providing and fixing server Customized develop version of web SCADA soft ware develoment with unlimited digital and analog I/O as spacified make CIMCON1Each
14768.02Provision and Installation of flow measurement devices to be installed at discharge point of the WTP ,collection tank, MBR and service storage tank with appropriate sensors along with the ptovision with the required data transmission system to central station for analysis with appropriate power back up system Tube Well 2 Nos\n collection Tank 1 No\nMBR;s 1 No\nSR's Existing 2 Nos\n5Each

AI Tender Summary

OUR REF NO 22556208
AUTHORITY Government Departments
TENDER VALUE 61.90 Lakhs
LAST DATE 02-12-2019
Authority
Authority Name Irrigation And Public Health Department
Work Description Improvement Of Lwss Tullah Including House Hold Connection To In Tehsil Lad Bharol Distt Mandi Sh C O Intake , Pump House , Main Storage Tank , P Laying , Jointing And Testing Of Rising Main , Supply Erection Of Pumping Machinery Gaseous Chlorination
Basic Detail
Tender No 6956-7005 dt. 16.11.2019
Bidding Type Tender
Location
City Lad Bharol
State Himachal Pradesh
Key Dates
Publish Date 19 Nov 2019
Submission Date 02 Dec 2019
Open Date 03 Dec 2019
Finance
Tender Value 61.90 Lakhs
Tender Fee 800
EMD 94405
Exemption Not Available
Document List
5DB7F1F9-8F8C-4E7A-B31E-9F7BB03546A2.html
Tendernotice_1.pdf
BOQ_47157.xls
Form8.pdf
SpecificationPM.pdf
term.pdf
NIT.pdf
Form6.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 02, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 03, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

5DB7F1F9-8F8C-4E7A-B31E-9F7BB03546A2.html

pdf

Tendernotice_1.pdf

xls

BOQ_47157.xls

pdf

Form8.pdf

pdf

SpecificationPM.pdf

pdf

term.pdf

pdf

NIT.pdf

pdf

Form6.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders