| 1 | 1 | Road Soling | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.001 | 3.15.2 : Compacting Original Ground<br>\n(ii) Compacting original ground supporting subgrade<br>\nLoosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2. | BI01010001010000000000000515BI0100001114 | 96 | cum |
|---|
| 3 | 1.002 | 4.12 : Construction of Water Bound Macadam using locally available material (Table 400.13)\t<br>\t\t\nProviding, laying spreading and compacting local material in block or large discrete particles, such as kankar, Laterite, Dhandla etc. as per Table 400.13 to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming requisite type of screening /binding materials to fill-up the interstices of laid material watering and compacting to the required density as per Clause 405.3 and Technical Specification Cluase 408. | BI01010001010000000000000515BI0100001115 | 38.4 | cum |
|---|
| 4 | 1.003 | 3.19.1.B : Surface Drains in SoilConstruction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.(B)Mechanical Means | BI01010001010000000000000515BI0100001116 | 100 | metre |
|---|
| 5 | 1.004 | 3.5.1 : Excavation in Cutting in Soil by manual means with lead upto 50 mExcavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 | BI01010001010000000000000515BI0100001117 | 9.45 | cum |
|---|
| 6 | 1.005 | od354036/2019_2020 : DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site. | BI01010001010000000000000515BI0100001118 | 9.45 | cum |
|---|
| 7 | 1.006 | od354037/2019_2020 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site | BI01010001010000000000000515BI0100001119 | 25.2 | cum |
|---|
| 8 | 1.007 | 11.4.3.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203III.P.C.C. grade M 20 (i)Nominal mix (1:2:4) | BI01010001010000000000000515BI0100001120 | 2.7 | cum |
|---|
| 9 | 1.008 | 11.8 : Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 | BI01010001010000000000000515BI0100001121 | 0.136 | tonne |
|---|
| 10 | 2 | Tarring | BI01010001010000000000000515BI0100001122 | | |
|---|
| 11 | 2.001 | 4.9 : Wet Mix Macadam\t<br>\t\t\nProviding, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.\t\t<br>\t\nBy Mechanical Means with 1 km lead | BI01010001010000000000000515BI0100001123 | 55.572 | cum |
|---|
| 12 | 2.002 | 5.1.1a : Prime Coat :-\t\t\t\t\t\nLow porosity\t<br>\t\t\t\t\t\t\t\n\tProviding and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 | BI01010001010000000000000515BI0100001124 | 705 | sqm |
|---|
| 13 | 2.003 | 5.2.3a : Tack Coat <br>Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. | BI01010001010000000000000515BI0100001125 | 705 | sqm |
|---|
| 14 | 2.004 | 5.9.1.2a : 20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65\t\t<br>\t\t\t\t\t\t\nProviding, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.\t\t<br>\t\t\t\t\t\t\nCase - I By Manual Means\t<br>\t\t\t\t\t\t\n(II)\tBitumen (S-65) | BI01010001010000000000000515BI0100001126 | 705 | sqm |
|---|
| 15 | 2.005 | 5.12.A.3.2a : Seal Coat - Manual Means - Type C - Bitumen S-65\t\t<br>\t\t\t\t\t\t\nProviding and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510\t\t<br>\t\t\t\t\t\t\nA.\tBy Manual Means\t:-\t\t\t\t\t\t\nCase - III : Type C\t<br>\t\t\t\t\t\t\t\n(II)\tBitumen (S-65) | BI01010001010000000000000515BI0100001127 | 705 | sqm |
|---|
| 16 | 2.006 | 3.19.1.B : Surface Drains in SoilConstruction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.(B)Mechanical Means | BI01010001010000000000000515BI0100001128 | 240 | metre |
|---|