Tender For Sanction Works To Certain Locations At Af Stn Samana Under Ge ( Af ) Jamnagar No 1
BOQ
| Name of Work: SANCTION WORKS TO CERTAIN LOCATIONS AT AF STN SAMANA UNDER GE (AF) JAMNAGAR NO 1 | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Excavation in post holes in soft / loose soil (or similar holes) each n.exc 0.5 cum, getting out, returning, refilling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in any type of soil, removing surplus soil to a distance n exc 50 m complete all as specified and directed.\n\n | 14 | Each | |
| 2 | 2 | S&F Steel work in trusses fabricated with reactangular / Square hollow section, including special shaped, washers etc including cutting, welding, bending in shape etc using tube of YST 310 grade confirming to to IS-4923 complete all as specified & directed.\n\n | 410 | Kg | |
| 3 | 3 | S&F 0.50 mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall or roof, fixed with self tapping / drilled screws as specified and as directed by Engineer-in-charge \n\n | 80 | Sqm | |
| 4 | 4 | S&F 0.50 mm thick Pre- painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall or roof, fixed with self tapping / drilled screws as specified and as directed by Engineer-in-charge \n\n | 9 | Sqm | |
| 5 | 5 | Supply & Fix 06 mm thick plain, multicavity poly carbonate sheet (coloured) in roof covering, fixed with and including aluminium fillets at joints and aluminium angles at the end, fixed with self drilled screws and standard fittings, fixtures and accessories complete all as specified and as per manufacturer's instructions all as specified and directed.\n\n | 30 | Sqm | |
| 6 | 6 | M&L for preparation of new steel surfaces of any discription over 10cm width or girth, not otherwise described and apply two coat of synthetic enamel paint over one coat of red oxide primer complete.\n\n | 50 | Sqm | |
| 7 | 7 | M & L for precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks exe 10 cm thick, in width (with plain or inter locking joints as directed) setting in CM 1:6 complete in wall or pillars all as specified and directed.\n\n | 1.5 | Cum | |
| 8 | 8 | M&L for rendering 15 mm thick on brick wall or concrete surface in cement mortar 1:4 finished even & fair all as specified and directed.\n\n | 20 | Sqm | |
| 9 | 9 | M&L for preparation of plastered surface of walls including plaster / cornices etc and applying two coats of Acrylic emulsion (exterior weather coat) paint of any tint as approved over one coat of primer applied as per manufacturer's instruction complete.\n\n | 20 | Sqm | |
| 10 | 10 | M&L for 100 mm thick plain cement concrete 1:4:8 type B2, using 40 mm graded stone aggregate, as in sub base to floors and paving etc all complete all as directed.\n\n | 136 | Sqm | |
| 11 | 11 | M&L for Rubber moulded Chequered cement concrete tiles of size 30 cm x 30 cm x 25 mm thick, in white cement with pigment, set, jointed in neat cement slurry & pointed in coloured cement, as in floors, laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.\n\n | 86 | Sqm | |
| 12 | 12 | M&L for cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation filling and mass concrete all as specified.\n\n | 3 | Cum | |
| 13 | 13 | M&L for Gypsum Board 12 mm thick for seamless false ceiling fixed with screw over and including Gl frame work comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick........\n\n | 80 | Sqm | |
| 14 | 13.01 | ........having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete as per manufacturer instruction.\n\n | |||
| 15 | 14 | M&L applying two coat of Distemper oil emulsion over one coat of primer over ceiling surface after perparation of surafec complete.\n\n | 80 | Sqm | |
| 16 | 15 | Supply, fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminatied including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size etc all as specified below complete all as specified and directed. \n\n | 5.12 | Sqm | |
| 17 | 15.01 | (a) Frame (top & side) section shall of size 101.60 x 44.75 x 2.4 mm ( Section No 14021)\n\n(b) Verticle Members of shutter Section shall be be of size 85.00 x 44.45 x 2.00 mm (Section No 19560)\n\n(c) Top Members of shutter Section shall be be of size 83.50 x 44.45 x 2.00 mm (Section No 19581)\n\n | |||
| 18 | 15.02 | (d) Lock rail (Middle member) of shutter Section shall be be of size 150.00 x 44.45 x 3.00 mm (Section No 19596)\n\n(e) Bottom Members of shutter Section shall be be of size 150.00 x 44.45 x 3.10 mm (Section No 19584)\n\n(f) Glazing clip for securing glass of shutters shall be be of 0.80 mm thick (Section No 19370).\n\n | |||
| 19 | 15.03 | Note:-\n(i) Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx B\n(ii) Floor door spring will be measured & paid seperatly..\n\n | |||
| 20 | 16 | S&F Double action floor spring hydraulically regulated, made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in position\n\n | 3 | EACH | |
| 21 | 17 | S&F 100 mm size 4-lever mild steel mortise lock vertical type with two keys etc complete.\n\n | 3 | Each | |
| 22 | 18 | Supply and fix 500 litres capacity double layer, rotational molded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position over and including 100 mm thick platform in PCC 1:3:6 type C1, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 25 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed by Eng-In-Charge.\n\n | 3 | Each | |
| 23 | 19 | Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil all as specified.\n\n | 30 | Sqm | |
| 24 | 20 | M & L for Hard core of broken stone of gauge exc 63 mm but n.exc 100 mm, deposited spread & leveled in layers n.exc 15 cm thick water and rolled / rammed to a true surface all complete all as directed.\n\n | 4.5 | Cum | |
| 25 | 21 | M&L for 75 mm thick plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in plinth protection including finished even and smooth without using extra cement and all as directed by Engr-in-charge.\n\n | 30 | SQM | |
| 26 | 22 | Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries to a distance exc 1.5 km but n.exc 3 Km\n\n | 2.1 | Ten Sqm | |
| 27 | 23 | M&L for light shade coloured vitrified ceramic tiles 9-10 mm thick (square/rectangular ) polished, area of each tiles n.exc 0.36 sqm in floors etc laid over and including 15 mm thick screed bed or bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles complete all as specified and directed. \n\n | 50 | Sqm | |
| 28 | 24 | Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC caping & casing not less than 25 mm wide, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick complete.\n\n | 5 | Point | |
| 29 | 25 | All as per item No 24 above but point wiring for one 5 Amps socket outlet on independent board controlled by one-way switch. \n\n | 4 | Point | |
| 30 | 26 | All as per item No 24 above but One bell /Buzzer point controlled by one push button on the independent board \n\n | 1 | Point | |
| 31 | 27 | All as per item No 24 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.\n\n | 5 | Point | |
| 32 | 28 | M&L for Switch Piano type, single pole, one way 6 amp, 230 V, including connecting complete.\n\n | 5 | Each | |
| 33 | 29 | M&L for Switch socket combination 6A- 230 V, 2/3 pin combined, including connecting complete. \n\n | 5 | Each | |
| 34 | 30 | M&L for Switch socket combination 6A / 16A- 230 V, Multpurpose, including connecting complete.\n\n | 5 | Each | |
| 35 | 31 | Supply and fix stepped type electronic fan regulator flush type, 230 V, including connecting complete.\n\n | 5 | Each | |
| 36 | 32 | M&L for Ceiling rose, 3 phase polycarbonate body 6 Amps, 230 volts AC, including connecting complete. \n\n | 6 | Each | |
| 37 | 33 | Supply and fix Ventilating fan 230 mm sweep AC, 240 volts, metal body, fixed as per manufacturer instruction, connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable complete. \n\nMake Havells Cat No. Ventil Air - DSP or equivalent of Make mention Appendix B.\n\n | 3 | Each | |
| 38 | 34 | M&L for Cutting hole in existing stone masonry wall built in cement mortar by means of stone cutter or other means, making hole suitable for fixing of Ventilating / exhaust fan up to 300 mm sweep, including making good the disturbed surface in cement mortar 1:4, to match with existing surface complete all as directed by Engr-in-Charge.\n\n | 6 | Each Job | |
| 39 | 35 | M&L for Cutting hole in existing stone masonry wall built in cement mortar by means of stone cutter or other means, making hole suitable for fixing of Window type AC, including making good the disturbed surface in cement mortar 1:4, to match with existing surface complete all as directed by Engr-in-Charge.\n\n | 4 | Each Job | |
| 40 | 36 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete.\n\n | 50 | RM | |
| 41 | 36.01 | Note:- 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.\n\n | |||
| 42 | 37 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete.\n\n | 235 | RM | |
| 43 | 37.01 | Note:- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.\n\n | |||
| 44 | 38 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC conduit not less than 25 mm bore with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete.\n\n | 30 | RM | |
| 45 | 38.01 | Note:- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.\n\n | |||
| 46 | 39 | Supply and fix metal clad single pole and earth enclosure with two pin and earth plugs and socket complete with one single pole MCB 20 Amps, 250 V, C type. \n\n | 11 | Each | |
| 47 | 40 | Supply, installation, connecting, testing & commissioning of pressure boosting system 1.0 HP capacity working on 220 V, 50 Hz, suction & delivery size 25 mm bore, 2800 RPM, head range 5 to 47 metre, discharge range 750 to 4200 litre per minute, including connecting with.....\n\n | 1 | Each Job | |
| 48 | 40.01 | ......existing pipe line by cutting 25 mm bore GI pipe, connecting with inlet & outlet of pump, making bypass arrangement by supply & fix 25 mm bore medium grade galvanised pipe not exceeding 1.5 metre long & 3 Nos 25 mm size Gun metal gate valve Heavy duty (ISI Marked) with iron wheel head screwed both ends for iron pipe including all fitting & fixture complete all as specified and directed by Engg-in-charge.\n\n | |||
| 49 | 40.02 | Note:- Electric supply for pump will be measured & paid separately\n\nMake:- Grundfos or equvallent make approved by the GE.\n\n | |||
| 50 | 41 | S&F in repair gun metal non return valves of size 15 mm bore ISI marked screwed both ends for iron pipe and fixed, all as specifed and directed .\n\n | 4 | Each | |
| 51 | 42 | S&F gun metal non return valves of size 25 mm bore ISI marked screwed both ends for iron pipe and fixed, all as specifed and directed .\n\n | 1 | Each | |
| 52 | 43 | S&F LED Street Light / building security light fitting 18 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with.....\n\n | 5 | Each | |
| 53 | 43.01 | ..... weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed over & incluiding new bracket fabricated with 25 mm bore 1200 mm long,light grade GI pipe bend to shape ,fixed on wall with MS flat iron clamp &nut bolt etc & connecting complete all as specified and directed.\n\n | |||
| 54 | 44 | S&F LED Street Light / building security light fitting 30 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed over & incluiding new bracket fabricated with 25 mm bore 1200 mm long,light grade GI pipe bend to shape ,fixed on wall with MS flat iron clamp &nut bolt etc & connecting complete all as specified and directed.\n\n | 15 | Each | |
| 55 | 45 | S&F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed.\n\n | 5 | Each | |
| 56 | 46 | Supply and fix MCB’s single pole 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.\n\n | 24 | Each | |
| 57 | 47 | Supply and fix MCB’s single pole & neutral, 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.\n\n | 8 | Each | |
| 58 | 48 | Supply and fix MCB’s triple pole & neutral, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.\n\n | 1 | Each | |
| 59 | 49 | Supply & installation of Air Cooled Inverter based window AC unit of capacity 1.5 Ton with cooling functions and suitable to operate at ambient conditions of (10 to 46 Deg Celsius in cooling Mode).\nAir conditioner will have following conditions:-\n(i) Refrigerant - R 410a (non CFC)\n(ii) EER - min 3.5 w/w (5 star rating)\n(iii) Tonnage - 1.5\n(iv) Indoor Noise Level - Not more than 48 Db\n(v) Filter - (a) Must have PM 2.5 µ Filter\n(b) Electrostatic dust filter\n(c) Oxidizer dust filter\n(vi) Functions of remote : \n(a) Air directional control\n(b) Auto Timer\n(c) Economic sleep mode\n(d) Auto fan speed\n(e) Auto swing\n(f) Temp display\n(g) Turbo mode\n\n | 4 | Each | |
| 60 | 50 | Supply & installation of Air Cooled Inverter based split AC unit of capacity 1.5 Ton with cooling functions and suitable to operate at ambient conditions of (10 to 46 Deg Celsius in cooling Mode).\n\n | 2 | Each | |
| 61 | 50.01 | Air conditioner will have following specifications/parameters:-\n(i) Refrigerant - R 410a (non CFC)\n(ii) EER - min 3.5 w/w (5 star rating)\n(iii) Tonnage - 1.5\n(iv) Indoor Noise Level - Not more than 48 Db\n(v) Filter - (a) Must have PM 2.5 µ Filter\n(b) Electrostatic dust filter\n(c) Oxidizer dust filter\n(vi) Functions of remote : \n(a) Air directional control\n(b) Auto Timer\n(c) Economic sleep mode\n(d) Auto fan speed\n(e) Auto swing\n(f) Temp display\n(g) Turbo mode\n\n | |||
| 62 | 50.02 | All specifications will be as per IS-1391 (Part 2) 1992\n\nMake: \nCarrier / Hitachi / O General / Blue Star\n\n | |||
| 63 | 50.03 | Note:- Following will be inclusive in rate:-\n(a) Piping length up to 05 mtr will be inclusive in item\n(b) Installation will include fixing the outdoor unit on the platform as per direction of Engineer in Charge\n(c) Installation will also include civil work for making hole on the wall and putting the iron sleeve for passing the refrigerant pipe\n\n | |||
| 64 | 50.04 | (d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge\n(e) Contractor will provide warranty of 5 years for compressor from the date of installation\n(f) Contractor shall provide complete free service in warranty period by the company\n\n | |||
| 65 | 51 | All as per Item No 50 above but Air Cooled Inverter based split AC unit of capacity 2 Ton\n\n | 3 | Each Job | |
| 66 | 52 | S&F Voltage stabilizer of automatic operation single phase naturally air cooled indoor type and designed for following features \n\n(a) Capacity : - 4 KVA\n(b) Working Voltage Range - 130 V-280V AC\n(c) Salient features \n-Intelligent time delay system 3 min\n-Compatible with regular and inverter AC\n-Wall mounting cabinet design\n-Low and high voltage cut off\n-Digital display\n\nMake: V guard / Daikin / Blue star\n \n | 6 | Each | |
| 67 | 53 | All as per Item No 52 above but Voltage stabilizer of Capacity 5 KVA\n\n | 3 | Each | |
| 68 | 54 | M&L for Hard drawn steel wire fabric cut to length, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt of weight per SQM not Exc 4 Kg.\n\n | 75 | Kg | |
| 69 | 55 | M&L for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe- 290 (Gde E- 165) including hinges and necessary bolt .\n\n | 75 | Kg | |
| 70 | 56 | Supply, installation, connecting, testing and commissioning of 100 KVA capacity oil cooled AC servo motor operated voltage stabilizer mounted in CRCC sheet ventilated enclosure powder coated with electrolyte copper winding & low loss magnetic core, copper wound tranformer in CRGO lamination, microprocessor based fully IC controlled sensing circuit with built in spike and surge suppressor, no distrotion in output waveform, all the phases are independently sensed and corrected, including first filling of transformer oil, compatible to both Main & DG supply, Low voltage cut off , High voltage cut off, signal phase preventer, ammeter with CTs and selector switch, servo by pass switch, time delay complete.\n\n | 2 | EACH | |
| 71 | 56.01 | (i) Input :- 340V to 460V , 47 to 53 Hz, 3 Phase\n\n | |||
| 72 | 56.02 | (ii) Output : 415V ± 2.5%, 3 phase, 50 Hz output should be star connected as per IS 9815.\n\n | |||
| 73 | 56.03 | (iii) Voltage Correction Rate: 8 V/Sec ( Phase to phase)\n\n | |||
| 74 | 56.04 | (iv) Response Time:- 10 mili sec\n\n | |||
| 75 | 56.05 | (v) Operating Temp. : -5 to 50 degree centigrade\n\n | |||
| 76 | 56.06 | (vi) Maximum Temp Rise: 50 degree centigrade\n\n | |||
| 77 | 56.07 | (vii) Servo Motor: 03 Nos of AC Synchronous motor for 3 Phase of less than 35 Watts as per IS 9815/1994\n\n | |||
| 78 | 56.08 | (viii) Oil Type: ONAN ( Oil Natural Air Natural ) cooled transformer oil conforming to IS: 335/1994\n\n | |||
| 79 | 56.09 | (ix) Control Panel: (a) Auto, Manual and Bypass operating toggle switch , (b) LED for Input ON ( Yellow) , © LED for output healthy ( Green) (d) LED for O/P trip (Red) , (e) Output voltage adjustment potentiometer ( screw with lock nut type )\n\n | |||
| 80 | 56.1 | (x) Alpha Numeric LCD / LED Unit for displaying following parameters in scrolling form:-\n\n | |||
| 81 | 56.11 | (a) Input & Output voltage (for all the phases)\n\n | |||
| 82 | 56.12 | (b) Current drawn (for all the phases )\n\n | |||
| 83 | 56.13 | (c) All faulty indications viz. Input voltage low / high & Output voltage low / high ,overload etc.\n\n | |||
| 84 | 56.14 | (xi) Alarm: Audio & visual alarm at tripping condition\n\n | |||
| 85 | 56.15 | (xii) Protection: (a) MCB/MCCB of suitable rating at Input/output. (b) Contactor for Low/High voltage cutoff\n\n | |||
| 86 | 56.16 | (xiii) Winding : 99.99% pure electrolyte cooper\n\n | |||
| 87 | 56.17 | (xiv) Duty Cycle: 100% continuous\n\n | |||
| 88 | 56.18 | (xv) Protection : IP 35\n\n | |||
| 89 | 56.19 | (xvi) Insulation: Class E\n\n | |||
| 90 | 56.2 | (xvii) Unidirectional Cast Iron wheel must be provided for easy movement.\n\n | |||
| 91 | 56.21 | (xviii) PF : Not less than 0.95 when tested on maximum load.\n\n | |||
| 92 | 56.22 | Note: Following Certificates to be given at the time of supply by manufacturer\n\n | |||
| 93 | 56.23 | (a) High Voltage test\n\n | |||
| 94 | 56.24 | (b) Rate of voltage correction\n\n | |||
| 95 | 56.25 | (c) Size & weight of core\n\n | |||
| 96 | 56.26 | (d) Size & total weight of winding\n\n | |||
| 97 | 56.273 | (e) Size, type and grade of copper wire used\n\n | |||
| 98 | 56.28 | (f) Insulation resistant \n\n | |||
| 99 | 57 | Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 150 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.\n\n | 80 | RM | |
| 100 | 58 | Supply and fix ON LOAD change over switch 4 pole, 415V, 50 Hz in sheet metal enclosures of capacity 320 Amps including frame structure for mounting change over switch made of angle 50x50x6 mm with two legs of height four feet including foundation and grouting as directed by Engr-in-charge.\n\n | 2 | Each | |
| 101 | 59 | Material and labour for tripod chemical earthing (comprising of three chemical earthing) as per drawing attached (Sketch No 01). \n\n | 2 | EACH | |
| 102 | 59.01 | The chemical earthing will have specification as follows :-\n \n(a) Copper electrode of wall thickness minimum 2 mm not less than 3 mtr length with not less than 75mm outer dia.\n\n | |||
| 103 | 59.02 | (b) Fixing of copper Earth Electrode by drilling / boring 175 mm dia hole, 5.00 mtr deep in any type of strata, placing electrode in hole, return filling excavated soil by mixing min 10 kg GEL per bore and 75 kg Soil Resistivity Improvement (SRIP) compound as per manufacturer instruction.\n\n | |||
| 104 | 59.03 | (c) FRP earthing result display board 254 x 380mm made out of plastic material showing information related to type of earthing, earthing result, due date of testing along with fixing size 610mm height made of plastic hollow pipe of dia 20 mm.\n\n | |||
| 105 | 59.04 | (d) Supply and fix Heavy duty poly plastic Earth pit cover of HDPE material, Bottom diameter ( OD 320 mm / ID 290 mm) of wall thickness 5 mm ,height 260 mm with top cover\n\n | |||
| 106 | 59.05 | Make:- Powertrac/McML Earthing Solution/Ashlock.\nNote :-\n(a) The copper strip for inter connection to each electrode will be included in quoted rate. \n\n | |||
| 107 | 59.06 | (b) All other items are included for chemical earthing in the item except copper strip for connecting to equipment and every other items is deemed to be included in the item.\n\n | |||
| 108 | 59.07 | (c) The chemical earthing will be carried out by the manufacturer or its authorized representative on the site.\n\n | |||
| 109 | 59.08 | (d) The earthing result will be obtained for each electrode must be less than 1?. Otherwise contractor is liable to do chemical earthing to meet the result without extra cost if the results are above 1?.\n\n | |||
| 110 | 59.09 | (e) Contractor must visit the site before quoting the tender to understand the difficulty and cost for carrying out the job in the station. It is important that contactor ascertain the quantum of work.\n\n | |||
| 111 | 59.1 | (f) Contractor must produce the certificate from the manufacturer that chemical earthing has been carried out by manufacturer. The manufacturer must also mention the warranty for chemical earthing.\n\n | |||
| 112 | 59.11 | (g) Extension strip from electrode strip upto 0.15 m height from GL to be deemed included in quoted rate including brazing\n\n(h) The contractor has to give in writing for 3 years guarantee for constant result of earth below 1?.\n\n | |||
| 113 | 60 | S&F earth continuity conductor or main earthing strip of Copper strip of size 50 x 6 mm complete fixed to wall / chases or buried in ground or drawn through conduit in any position or any other situation for loop earthing etc with and including epoxy insulators with necessary fixture complete all as specified and directed by Engg -in - Charge.\n\n | 30 | RM | |
| 114 | 61 | Material & Labour for flame proof point wiring for one light / Fan point controlled by one flameproof switch, complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen) cable 1100 volts grade ISI marked drawn and including mild steel ERW conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc complete.\n\n | 13 | Point | |
| 115 | 62 | S & F flame proof Switch rotary type with termination box in LM6, single pole 250V complete. \n\nMake:- Sudhir- Cat No RI/OA/1010.2A or equivalent of make mention in Appex B \n\n | 13 | Each | |
| 116 | 63 | S&F LED tube light fitting, flameproof type FLP-WP with T5 LED lamp of 20 watt including integral reflector made of alluminium alloy LM6 , with electronic ballast, bipin holders, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete. \n\nMake: Sudhir Cat No FF/1272 or equivalent of make mention in Appex B \n\n | 10 | Each | |
| 117 | 64 | S&F flame proof exhaust fan of size 305 mm (12'') sweep 240 V 50 Hz , 1440 RPM single phase heavy duty complete with louver shutter and flame proof wire from ceiling rose to exhaust fan all as directed.\n\nMake: Sudhir cat No RCP / 198 or equivalent of make mention in Appex B\n\n | 3 | Each | |
| 118 | 65 | Supply and fix on wall or laid on floor 50 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge. \n\n | 36 | RM | |
| 119 | 66 | Supply and fix 40 mm bore Mild steel water tubing, Heavy grade and connecting to water supply pipe laid in position, applying anticorrosive paint over one coat red oxide primer, confirming to IS 1239, including taking down old pipe complete all as specified and directed by Engg-in-Charge\n\n | 60 | RM | |
| 120 | 67 | Supply and fix 50 mm bore Mild steel water tubing, Heavy grade and connecting to water supply pipe laid in position, applying anticorrosive paint over one coat red oxide primer, confirming to IS 1239, including taking down old pipe complete all as specified and directed by Engg-in-Charge\n\n | 3 | RM | |
| 121 | 68 | Supply and fix 65 mm bore Mild steel water tubing, Heavy grade and connecting to water supply pipe laid in position, applying anticorrosive paint over one coat red oxide primer, confirming to IS 1239, including taking down old pipe complete all as specified and directed by Engg-in-Charge\n\n | 29 | RM | |
| 122 | 69 | Supply and fix 80 mm bore Mild steel water tubing, Heavy grade and connecting to water supply pipe laid in position, applying anticorrosive paint over one coat red oxide primer, confirming to IS 1239, including taking down old pipe complete all as specified and directed by Engg-in-Charge\n\n | 75 | RM | |
| 123 | 70 | Supply and fix 100 mm bore Mild steel water tubing, Heavy grade and connecting to water supply pipe laid in position, applying anticorrosive paint over one coat red oxide primer, confirming to IS 1239, including taking down old pipe complete all as specified and directed by Engg-in-Charge\n\n | 12 | RM | |
| 124 | 71 | Supply and fix 150 mm bore Mild steel water tubing, Heavy grade and connecting to water supply pipe laid in position, applying anticorrosive paint over one coat red oxide primer, confirming to IS 1239, including taking down old pipe complete all as specified and directed by Engg-in-Charge\n\n | 27 | RM | |
| 125 | 72 | Supply and lay 200 mm bore ERW mild steel pipe with 5 mm wall thickness, including all fixture laid in position, applying anticorrosive paint over one coat red oxide primer, confirming to IS 3589 (1981), including taking down old pipe complete all as specified and directed by Engg-in-Charge\n\n | 21 | RM | |
| 126 | 72.01 | Note for Item No.66 to 72 :-\n(i) Pipe shall be jointed with Flanged joint and same will be measured & Paid seperatly.\n\n(ii) Fitting such as bend etc will be measured & paid seperatly.\n\n | |||
| 127 | 73 | S&F MS Slip On Flange suitable for 40 mm bore MS pipe including welding to pipe complete all as specified & directed by the Engineer-in-Charge.\n\n | 8 | Each Flange | |
| 128 | 74 | S&F MS Slip On Flange suitable for 50 mm bore MS pipe including welding to pipe complete all as specified & directed by the Engineer-in-Charge.\n\n | 2 | Each Flange | |
| 129 | 75 | S&F MS Slip On Flange suitable for 65 mm bore MS pipe including welding to pipe complete all as specified & directed by the Engineer-in-Charge.\n\n | 12 | Each Flange | |
| 130 | 76 | S&F MS Slip On Flange suitable for 80 mm bore MS pipe including welding to pipe complete all as specified & directed by the Engineer-in-Charge.\n\n | 6 | Each Flange | |
| 131 | 77 | S&F MS Slip On Flange suitable for 100 mm bore MS pipe including welding to pipe complete all as specified & directed by the Engineer-in-Charge.\n\n | 6 | Each Flange | |
| 132 | 78 | S&F MS Slip On Flange suitable for 150 mm bore MS pipe including welding to pipe complete all as specified & directed by the Engineer-in-Charge.\n\n | 8 | Each Flange | |
| 133 | 79 | S&F MS Slip On Flange suitable for 200 mm bore MS pipe including welding to pipe complete all as specified & directed by the Engineer-in-Charge.\n\n | 4 | Each Flange | |
| 134 | 80 | S&F MS reducer Bend (80 mm to 150 mm) Flanged End heavy duty complete all as specified & directed by the Engineer-in-Charge.\n\n | 1 | Each | |
| 135 | 81 | S&F MS Bend 150 mm Flanged End heavy duty complete all as specified & directed by the Engineer-in-Charge.\n\n | 1 | Each | |
| 136 | 82 | S&F MS Bend 200 mm Flanged End heavy duty complete all as specified & directed by the Engineer-in-Charge.\n\n | 6 | Each | |
| 137 | 82.01 | Note for Item No. 6 to 12 :-\n(i) Flanged joint with nut bolt will be measured & Paid seperatly.\n\n | |||
| 138 | 83 | M&L for flanged Jointing of 40 mm / 50 mm dia MS pipe with rubber or fibre board gasket including nut bolt washer complete all as specified & directed by the Engineer-in-Charge.\n\n | 5 | Each Joint | |
| 139 | 84 | M&L for flanged Jointing of 65 mm / 80 mm dia MS pipe with rubber or fibre board gasket including nut bolt washer complete all as specified & directed by the Engineer-in-Charge.\n\n | 9 | Each Joint | |
| 140 | 85 | M&L for flanged Jointing of 100 mm dia MS pipe with rubber or fibre board gasket including nut bolt washer complete all as specified & directed by the Engineer-in-Charge.\n\n | 3 | Each Joint | |
| 141 | 86 | M&L for flanged Jointing of 150 mm dia MS pipe with rubber or fibre board gasket including nut bolt washer complete all as specified & directed by the Engineer-in-Charge.\n | 4 | Each Joint | |
| 142 | 87 | M&L for flanged Jointing of 150 mm dia MS pipe with rubber or fibre board gasket including nut bolt washer complete all as specified & directed by the Engineer-in-Charge.\n\n | 2 | Each Joint | |
| 143 | 88 | Suply and fix in repair UPVC pipe of 32 mm bore , SCH 40 rating fixed complete to walls, ceilings or in floors etc along with its taking down old pipe as directed by Engr-in-charge.\n\n | 16 | RM | |
| 144 | 89 | Supply and fix in repair UPVC ball valve of size 32 mm bore.\n\n | 4 | Each | |
| 145 | 90 | Supply and fix in repair 100 litres capacity double layer, rotational molded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 25 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed by Eng-In-Charge.\n\n | 1 | Each | |
| 146 | 91 | Supply and fix in repair 250 litres capacity double layer, rotational molded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 25 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed by Eng-In-Charge.\n\n | 1 | Each | |
| 147 | 92 | Supply and fix in repair 80 mm size cast iron sluice valve of pressure rating PN-1.6 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 complete.\n\n | 1 | Each | |
| 148 | 93 | Supply and fix in repair 100 mm size cast iron sluice valve of pressure rating PN-1.6 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 complete.\n\n | 8 | Each | |
| 149 | 94 | Supply and fix in repair 50 mm size cast iron butterfly valve of pressure rating PN-1.6 with, both end flanged, ISI marked with nut, bolt, washer, rubber packing etc., confirming to IS-13095 complete.\n\n | 3 | Each | |
| 150 | 95 | Supply and fix in repair 80 mm size cast iron butterfly valve of pressure rating PN-1.6 with, both end flanged, ISI marked with nut, bolt, washer, rubber packing etc., confirming to IS-13095 complete.\n\n | 10 | Each | |
| 151 | 96 | Supply and fix in repair 150 mm size cast iron butterfly valve of pressure rating PN-1.6 with, both end flanged, ISI marked with nut, bolt, washer, rubber packing etc., confirming to IS-13095 complete.\n\n | 8 | Each | |
| 152 | 97 | Supply and fix in repair 100 mm size cast iron Strainer, both end flanged, ISI marked with nut, bolt, washer, rubber packing etc., complete.\n\n | 3 | Each | |
| 153 | 98 | Supply and fix in repair 40 mm size cast iron Ball valve, flanged end, ISI marked with nut, bolt, washer, rubber packing etc., complete.\n\n | 8 | Each | |
| 154 | 99 | Supply and fix in repair Cast Iron Air release Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in MS Water supply mains of size 100 mm dia.\n\n | 5 | Each | |
| 155 | 100 | Supply and fix in repair Non return valve cast iron dual plated type of PN1.6 conforming to IS, size 100 mm (4”) dia.\n\n | 6 | Each | |
| 156 | 101 | Supply and fix in repair Non return valve cast iron dual plated type of PN1.6 conforming to IS, size 65 mm (2.5”) dia.\n\n | 2 | Each | |
| 157 | 102 | Supply and fix in repair Non return valve cast iron dual plated type of PN1.6 conforming to IS, size 50 mm (2”) dia.\n\n | 2 | Each | |
| 158 | 103 | Supply and fix in repair pressure guage of dial showing 1 to 8 Kg/cm2 of dial size 50mm.\n\n | 13 | Each | |
| 159 | 104 | S&F in repair electronic metering pump for capacity dosing rate 4 Kg per square cm of 400 stokes per minute set for chlorine dozing and incl suitable guage rewiring copper wire with properly insulating material with LCD display,internal circuit,solenoide valve, bearing,impellar,bush,shaft,suction valve,discharge valve complete.\n\n | 1 | EACH | |
| 160 | 105 | M&L in repair for taking out and Servicing of motor and pump of capcity 10.2 HP three phase monoblock non clog type submerssible motor, of sewage Lift well , & rewinding of motor with super enameled copper wire of existing size including greasing and coupling with motor and testing and replacement of ball bearing set,impellar of pump,shaft,bush, cooling fan along with its safety cover complete required at drive end and fixed the motor at its place with connection discharge pipe complete as directed by Engr-in-charge.\n\n | 2 | Each job | |
| 161 | 106 | M&L in repair Servicing of motor and pump of capcity 0.5 HP single phase induction motor, of CSTP plant , & rewinding of motor with super enameled copper wire of existing size including greasing and coupling with motor and testing and replacement of ball bearing set,impellar of pump,shaft,bush complete required at drive end.\n\n | 1 | Each job | |
| 162 | 107 | M&L in repair Servicing of motor and pump of capcity 20 HP three phase monoblock non clog type submerssible motor of sewage shallow well , & rewinding of motor with super enameled copper wire of existing size including greasing and coupling with motor and testing and replacement of ball bearing set,impellar of pump,shaft,bush, cooling fan along with its safety cover complete required at drive end and fixed the motor at its place with connection discharge pipe complete as directed by Engr-in-charge.\n\n | 2 | Each job | |
| 163 | 108 | M&L in repair Servicing of motor and pump of capcity 10.2 HP three phase Induction centrifugal type motor of CSTP, & rewinding of motor with super enameled copper wire of existing size including greasing and coupling with motor and testing and replacement of ball bearing set,impellar of pump,shaft,bush complete required at drive end and fixed the motor at its place with connection discharge pipe complete as directed by Engr-in-charge.\n\n | 2 | Each job | |
| 164 | 109 | M&L in repair Servicing of motor and pump of capcity 5 HP single phase induction motor, of CSTP plant for feeding to dual media filter , & rewinding of motor with super enameled copper wire of existing size including greasing and coupling with motor and testing and replacement of ball bearing set,impellar of pump,shaft,bush, cooling fan along with its safety cover complete required at drive end.\n\n | 1 | Each job | |
| 165 | 110 | M&L in repair Servicing of motor and pump of capcity 2.2 HP single phase induction non clog type motor, of CSTP plant , & rewinding of motor with super enameled copper wire of existing size including greasing and coupling with motor and testing and replacement of ball bearing set,impellar of pump,shaft,bush,cooling fan along with its safety cover complete required at drive end.\n\n | 1 | Each job | |
| 166 | 111 | M&L in repair for servicing of twin lobe air cooled compressor by dismantling all of its internal parts along with its driving motor of capcity 10 HP make USHA of air delivery capcity 350 m^3/hrs and dischrage pressure 6.5 kg/cm^2,motor speed 1450 RPM of discharge presssure 4000 mm water column with change of its bearing and shaft , all gaskit sealing ,all O ring,oil seal,pressure ring,oil drain plug grinding of gears wheeels, lobe and arrange again in its position with it with gear.Repalcement of gear oil paid seprately in item no 44.\n\n | 2 | Each job | |
| 167 | 112 | M&L for pouring gear oil suitable for USHA twin lobe air cooled compressor of grade ENKLO 320 or equivalent .\n\n | 60 | Ltrs | |
| 168 | 113 | M&L for Cleaning of following sewage tank / sump of diameter up to 8 mtrs and depth up to 8 mtr by bailing out complete water, removing all the accumulated sediments, sludge and foreign particles etc and depositing at a distance not less than 500 mtrs from the site including scrubbing, brushing and removing all the dirt / sludge accumulated on the walls / floor etc as and when required all as directed by Engr-in-Charge for the following locations:-\n\n | 2 | Job | |
| 169 | 113.01 | (a) CSTP Plant of capacity 400 m3/day at Helipad comprising of following (i) Oil and Grease Trap Chamber \n(ii) Equalization tank \n(iii) MBBR-1&2 \n(iv)Chlorine contact tank \n(v) Filter feed tank\n(vi) Treated Water Tank \n(vii) Sludge Tank\n(b) Collection Sump Behind OMQ\n(C) Lift Well in SMQ\n\n | |||
| 170 | 113.02 | Note:- \n(a) Any type of sludge collected during cleaning shall be removed at least 500 Mtrs away from cleaning place or as directed at site by Eng-in-Charge \n(b)Safety precautions as per CP norms will be ensured during cleaning of well.\n\n | |||
| 171 | 114 | Supply and fix in repair compressed air flow Switch 40mm size of capacity of maximum air flow of 100 m3/hrs operating temperature 85 degree centrigrade and max pressure of 1 kg/cm2.\nMake:-Pune Techtrol / TRAC / Asterall \n\n | 1 | Each | |
| 172 | 115 | Supply & fix in repair only V Belt B-52, suitable for Air compressor of capacity 350 m3/hrs\n\nMake:-Continental or Equivalent make approved by the GE\n\n | 4 | Each | |
| 173 | 116 | Supply &fix in repair grob Air Filter for Air suction Blower as per sample kept in GE's Office\n\n | 2 | Each | |
| 174 | 117 | Supply and fix in repair submersible pump cable flat along with taking down old cable, PVC insulated, PVC sheathed, multistranded copper conductor of size 10 Sqmm 3 core 1100 volt grade & connecting complete including taking down unserviceable.\n\n | 100 | RM | |
| 175 | 118 | Supply and fix in repair spring loaded pressure safety valve size 65mm of bronze material and handling air pressure capacity of 5 bar and 350 m3/hr flow.\n\n | 2 | Each | |
| 176 | 119 | Supply and fix in repair submerssible pump controller heavy duty in sheet metal enclosure with single phase protection, type MU-G ,suitable for 415 V, 3 phase,50 HZ,relay maxium range 28-42 ampere, submerssible motor of capacity 20 HP. \n\n | 2 | Each | |
| 177 | 120 | Supply and fix in repair submerssible pump controller in sheet metal enclosure with single phase protection, type MU-G ,suitable for 415 V, 3 phase,50 HZ,relay maxium range 9-14 ampere, suitable for 3 phase submerssible motor of capacity 10 HP \n\n | 1 | Each | |
| 178 | 121 | Supply and fix in repair fully automatic star delta starter in sheet metal enclosure with single phase protection, type K ,suitable for 3 phase submerssible motor of capacity 12.5 HP. Relay\n\n | 2 | Each | |
| 179 | 122 | S&F in repair MBBR(moving bed bio reactor) media for sewage treatement plant of capacity 400 m3/day MOC PP,black color of size 16mm x 22 mm.\n\n | 12 | Cum | |
| 180 | 123 | S&F in repair tube settler media along with removal of old tube media for STP of capacity 400 m3/day, MOC,:PVC of hexagonal chevron shape,black color of length 750 mm\n\n | 12 | Cum | |
| 181 | 124 | M&L for complete removal of existing treatment of walls including oil, grease, efflorescent salts and applying two coats of oil bound distemper as per manufacturer's instruction complete.\n\n | 1100 | Sqm | |
| 182 | 125 | M&L for preparation of old plastered surface of walls including plaster/ cornices etc and applying one coat of Acrylic emulsion (exterior weather coat) paint of any tint as approved over one coat of primer applied as per manufacturer's instruction complete.\n\n | 300 | Sqm | |
| 183 | 126 | M&L for preparation of old steel surfaces and applying one coat of synthetic enamel paint complete all as specified.\n\n | 50 | Sqm | |
| 184 | 127 | M&L for preparation of old plastered surface on wall and applying a coat of white wash complete all as specified and as directed.\n\n | 1000 | Sqm |
AI Tender Summary
Tender Timeline
Nov 16, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedDec 09, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 10, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender