Public Administrative Department Local Bodies Closing in 0 days TDR #22510577

Supply , Laying And Fixing Of 6 . 6 Kv ( E ) 185 Sq Mm Xlpe 3 Core Cable And Cable Kit At Pump House No 02 And Sub Station No 01 Supply , Laying And Fixing Of 6 . 6 Kv ( E ) 185 Sq Mm Xlpe 3 Core Cable And Cable Kit At Pump House No 02 And Sub Stat

Issued by Local Bodies · Mandleshwar, Madhya Pradesh
Tender Value
6.43 Lakhs
Estimated cost
Bid Submission
28 Nov 2019
0 days left
EMD
13000
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mandleshwar → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply , Laying And Fixing Of 6 . 6 Kv ( E ) 185 Sq Mm Xlpe 3 Core Cable And Cable Kit At Pump House No 02 And Sub Station No 01 Supply , Laying And Fixing Of 6 . 6 Kv ( E ) 185 Sq Mm Xlpe 3 Core Cable And Cable Kit At Pump House No 02 And Sub Station No 01 . , As Per List Enclosed , Supply Of 6 . 6 Kv ( E ) 185 Sq . Mm X 3 Core Xlpe Cable Stranded Compact Circular Aluminum Conductor , Conductor Screen With Extruded Semi Conducting Compound , Xlpe Insulated , Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape ( 0 . 2 Ka Per 1Sec/Core ) , Core Laid Up Innersheath Of Pvc Tape Galvainzed Flat Steel Strip Aroured And Overall Pvc Sheather Cable Conforming To Is 7098/ ( Part Ii ) 1985 With Latest Amendment . Isi Marked . 160Mtr+160Mtr Make Polycab/Gloster/Phinolex , Removing Exsisting 2 No . Cable Layed Between Ph -2 & Ss-1 From Trench Bundling And Shifting Same To Store At T . P Site Colony . , Laying Of One Number Pilc/Pvc Insulated And Pvc Sheathed Power Cable Of Grade Exceeding 1 . 1Kv But Not Exceeding 11 Kv Of Size Not Exceeding 400 Sq . Mm In The Exsisting Masonry Open Duct And Looping Both End As Required , Providing , Fixing & Making Rycheme Make Indoor Cable End Termination With Head Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For 6 . 6 Kv 185 Sq . Mm . 3Core Xlpe Aluminium Conductor Cable As Required As Per Specification & As Per Accepted Standard On Feeder No 2 And Connecting Same To Exsisting Feeder And Phase Sequence At Ss-1 & Ph-2 , Providing , Fixing & Making Rychame Make Indoor Cable End Termination With Heat Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For 6 . 6 Kv 185 Sq . Mm 3Core Xlpe Aluminum Conductor Cable As Required As Per Spacification & As Per Accepted Standard On Feeder No 01 Including Cutting Of Existing Pvc Surrounded Compound Filled Cable Kit Without Cutting Calbe Leads And Connecting Same To Exsisting Feeder And Phase Sequence At Ss-1 & Ph-2

BOQ

Name of Work:Supply, Laying & fixing of 6.6 KV (E) 185 Sq mm XLPE 3 core Cable & cable kit at pump house No 02 and Sub Station No 01
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11As Per List EnclosedBI01010001010000000000000515BI0100001112
21.01Supply of 6.6 KV (E) 185 Sq. mm x 3 core XLPE cable stranded compact circular aluminum conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape (0.2 KA Per 1sec/core), core laid up innersheath of PVC tape galvainzed flat steel strip aroured and overall PVC sheather cable conforming to IS 7098/ (Part II) 1985 with latest amendment. ISI marked. 160mtr+160mtr Make Polycab/Gloster/PhinolexBI01010001010000000000000515BI0100001113320mtr
31.02Removing exsisting 2 no. cable layed between PH -2 & SS-1 From trench bundling and shifting same to store at T.P site colony.BI01010001010000000000000515BI01000011141Job
41.03Laying of one number PILC/PVC insulated and PVC sheathed power cable of grade exceeding 1.1KV but not exceeding 11 KV of size not exceeding 400 Sq.mm in the exsisting masonry open duct and looping both end as requiredBI01010001010000000000000515BI0100001115320mtr
51.04Providing, fixing & making rycheme make indoor cable end termination with head shrinkable jointing kit complete with all accessories including lugs suitable for 6.6 KV 185 Sq.mm . 3core XLPE aluminium conductor cable as required as per specification & as per accepted standard on feeder no 2 and connecting same to exsisting feeder and phase sequence at SS-1 & PH-2BI01010001010000000000000515BI01000011164job
61.05Providing, fixing & making rychame make indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 6.6 KV 185 Sq. mm 3core XLPE aluminum conductor cable as required as per spacification & as per accepted standard on feeder no 01 including cutting of existing PVC surrounded compound filled cable kit without cutting calbe leads and connecting same to exsisting feeder and phase sequence at SS-1 & PH-2BI01010001010000000000000515BI01000011174job

AI Tender Summary

OUR REF NO 22510577
AUTHORITY Local Bodies
TENDER VALUE 6.43 Lakhs
LAST DATE 28-11-2019
Authority
Authority Name Indore Municipal Corporation
Work Description Supply , Laying And Fixing Of 6 . 6 Kv ( E ) 185 Sq Mm Xlpe 3 Core Cable And Cable Kit At Pump House No 02 And Sub Station No 01 Supply , Laying And Fixing Of 6 . 6 Kv ( E ) 185 Sq Mm Xlpe 3 Core Cable And Cable Kit At Pump House No 02 And Sub Station No 01 . , As Per List Enclosed , Supply Of 6 . 6 Kv ( E ) 185 Sq . Mm X 3 Core Xlpe Cable Stranded Compact Circular Aluminum Conductor , Conductor Screen With Extruded Semi Conducting Compound , Xlpe Insulated , Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape ( 0 . 2 Ka Per 1Sec/Core ) , Core Laid Up Innersheath Of Pvc Tape Galvainzed Flat Steel Strip Aroured And Overall Pvc Sheather Cable Conforming To Is 7098/ ( Part Ii ) 1985 With Latest Amendment . Isi Marked . 160Mtr+160Mtr Make Polycab/Gloster/Phinolex , Removing Exsisting 2 No . Cable Layed Between Ph -2 & Ss-1 From Trench Bundling And Shifting Same To Store At T . P Site Colony . , Laying Of One Number Pilc/Pvc Insulated And Pvc Sheathed Power Cable Of Grade Exceeding 1 . 1Kv But Not Exceeding 11 Kv Of Size Not Exceeding 400 Sq . Mm In The Exsisting Masonry Open Duct And Looping Both End As Required , Providing , Fixing & Making Rycheme Make Indoor Cable End Termination With Head Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For 6 . 6 Kv 185 Sq . Mm . 3Core Xlpe Aluminium Conductor Cable As Required As Per Specification & As Per Accepted Standard On Feeder No 2 And Connecting Same To Exsisting Feeder And Phase Sequence At Ss-1 & Ph-2 , Providing , Fixing & Making Rychame Make Indoor Cable End Termination With Heat Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For 6 . 6 Kv 185 Sq . Mm 3Core Xlpe Aluminum Conductor Cable As Required As Per Spacification & As Per Accepted Standard On Feeder No 01 Including Cutting Of Existing Pvc Surrounded Compound Filled Cable Kit Without Cutting Calbe Leads And Connecting Same To Exsisting Feeder And Phase Sequence At Ss-1 & Ph-2
Basic Detail
Tender No 06
Bidding Type Tender
Location
City Mandleshwar
State Madhya Pradesh
Key Dates
Publish Date 15 Nov 2019
Submission Date 28 Nov 2019
Open Date 03 Dec 2019
Finance
Tender Value 6.43 Lakhs
Tender Fee 2000
EMD 13000
Exemption Not Available
Document List
2DFEA95F-AA4C-4B5B-9B73-2A5494C0F6A3.html
TENDERDOCUMENT.pdf
Tendernotice_1.pdf
BOQ_73411.xls
8469409_21456_21112019.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 15, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 28, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 03, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

2DFEA95F-AA4C-4B5B-9B73-2A5494C0F6A3.html

pdf

TENDERDOCUMENT.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_73411.xls

pdf

8469409_21456_21112019.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders