| 1 | 1 | Taking out the unsv ballast from the fittings & supply, fixing with new copper wound HPSV ballast 70 Watts, 230 volt complete all as specified and directed. | BI01010001010000000000000515BI0100001113 | 5 | Each |
|---|
| 2 | 2 | Taking out the unsv ballast from the fittings & supply, fixing with new copper wound HPSV ballast 150 Watts, 230 volt complete all as specified and directed. | BI01010001010000000000000515BI0100001114 | 88 | Each |
|---|
| 3 | 3 | Taking out the unsv ballast from the fittings & supply, fixing with new copper wound HPSV ballast 250 Watts, 230 volt complete all as specified and directed. | BI01010001010000000000000515BI0100001115 | 75 | Each |
|---|
| 4 | 4 | Taking out the unsv ballast from the fittings & supply, fixing with new copper wound metal halide/HPSV ballast 400 Watts, 230 volt complete all as specified and directed. | BI01010001010000000000000515BI0100001116 | 37 | Each |
|---|
| 5 | 5 | Taking out the unsv ballast from the fitting and supply & fixing with new electronic ballast 2X24 Watt 230 Volt complete all as specified and directed. | BI01010001010000000000000515BI0100001117 | 40 | Each |
|---|
| 6 | 6 | Taking out the unsv ballast from the fittings and supply, fixing with new electronic ballast 2x36 Watts 230 Volt complete all as specified and directed. | BI01010001010000000000000515BI0100001118 | 45 | Each |
|---|
| 7 | 7 | Taking out the unsv lamp from the fittings & supply, fixing with HPSV Tubular type lamp 70 watt, 230 volt complete all as specified and directed. | BI01010001010000000000000515BI0100001119 | 10 | Each |
|---|
| 8 | 8 | Taking out the unsv lamp from the fittings & supply, fixing with HPSV Tubular type lamp 150 watt, 230 volt complete all as specified and directed. | BI01010001010000000000000515BI0100001121 | 110 | Each |
|---|
| 9 | 9 | Taking out the unsv lamp from the fittings & supply, fixing with HPSV Tubular type lamp 250 watt, 230 volt complete all as specified and directed. | BI01010001010000000000000515BI0100001122 | 110 | Each |
|---|
| 10 | 10 | Taking out the unsv lamp from the fittings & supply, fixing with HPSV Tubular type lamp 400 watt, 230 volt complete all as specified and directed. | BI01010001010000000000000515BI0100001123 | 5 | Each |
|---|
| 11 | 11 | Taking out the unsv lamp from the fittings & supply, fixing with new metal halide Tubular type lamp 400 watt, 230 volt complete all as specified and directed. | BI01010001010000000000000515BI0100001124 | 40 | Each |
|---|
| 12 | 12 | Taking out the unsv FTL and supply, fixing FTL 24 Watt 230 Volt complete all as specified and directed.\n | BI01010001010000000000000515BI0100001125 | 120 | Each |
|---|
| 13 | 13 | Taking out the unsv PL and supply fixing CFL PL 36 Watt 230 Volt complete all as specified and directed. | BI01010001010000000000000515BI0100001126 | 130 | Each |
|---|
| 14 | 14 | Taking out the unsv ignitor & supply fixing Ignitor for Metal halide / SV lamp 230 volt (suitable for 70, 150, 250 & 400 Watt) complete all as specified and directed. | BI01010001010000000000000515BI0100001127 | 235 | Each |
|---|
| 15 | 15 | Taking out the unsv Capacitor & supply fixing Capacitor for Metal halide / SV lamp 230 volt ( suitable for 10 Mfd) complete all as specified and directed. | BI01010001010000000000000515BI0100001128 | 10 | Each |
|---|
| 16 | 16 | Taking down the old and rusted GI bracket and supply fixing GI bracket of 40mm dia duly painted with two coat of supper enamelled paint over a coat of red oxide including suitable clamps nuts bolts and washers etc complete all as specified and directed. | BI01010001010000000000000515BI0100001129 | 190 | Each |
|---|
| 17 | 17 | Taking out the unsv lamp holder & supply fixing new lamp holder porcelene threaded / pin type upto (70,150, 250, & 400 Watt) capacity complete all as specified and directed. | BI01010001010000000000000515BI0100001130 | 10 | Each |
|---|
| 18 | 18 | Lowering down of high mast light at any height repairing and replacement of unserviceable parts such as ignitor, capacitor, ballast, lamp and internal and external circuit etc of existing make complete all as specified and directed.\nNote : Spare / parts required for replacement shall be measured and paid seperately | BI01010001010000000000000515BI0100001132 | 6 | Each |
|---|
| 19 | 19 | Taking down the existing street light fitting and Supply & fix (in repair) LED street light fitting 60 Watt with LED lamps and driver and made of pressure die-cast aluminium housing IP 65/IP66 road way luminaries (wider beam angle not less than 120 degree, optics with convex lens/pinet lens) with UV stablized polycarbonate cover or toughen glass cover and high power LEDs as light source with LED fittings system Lumen not less than 95 lumen per watt and electronic driver with efficiency 85% with inbuilt protection against lighting, over voltage, short circuit and surge/spike protection upto 5 KV ensuring longer life (THD<10%, PF shall be > 0.95, colour temperature 5700±300K), life expectancy of LEDs minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than three years. The fitting shall be tested in NABL accredited LAB and LM 80 test certificate shall be submitted by the original manufacturer. The light fittings shall be fixed on pole with and including 25 mm dia ( or higher size as per manufacturer recommendation), bracket 1.5 m long complete with MS flat iron clamps (clamp shall be 40x5 mm MS flat), nuts and bolts and washers painting the clamps with coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed. | BI01010001010000000000000515BI0100001133 | 110 | Each |
|---|
| 20 | 20 | Taking down the existing street light fitting and Supply & fix (in repair) LED street light fitting 72 Watt with LED lamps and driver and made of pressure die-cast aluminium housing IP 65/IP66 road way luminaries (wider beam angle not less than 120 degree, optics with convex lens/pinet lens) with UV stablized polycarbonate cover or toughen glass cover and high power LEDs as light source with LED fittings system Lumen not less than 95 lumen per watt and electronic driver with efficiency 85% with inbuilt protection against lighting, over voltage, short circuit and surge/spike protection upto 5 KV ensuring longer life (THD<10%, PF shall be > 0.95, colour temperature 5700±300K), life expectancy of LEDs minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than three years. The fitting shall be tested in NABL accredited LAB and LM 80 test certificate shall be submitted by the original manufacturer. The light fittings shall be fixed on pole with and including 25 mm dia ( or higher size as per manufacturer recommendation), bracket 1.5 m long complete with MS flat iron clamps (clamp shall be 40x5 mm MS flat), nuts and bolts and washers painting the clamps with coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed. | BI01010001010000000000000515BI0100001134 | 40 | Each |
|---|
| 21 | 21 | Taking down the existing street light fitting and Supply & fix (in repair) LED street light fitting 50 Watt with LED lamps and driver and made of pressure die-cast aluminium housing IP 65/IP66 road way luminaries (wider beam angle not less than 120 degree, optics with convex lens/pinet lens) with UV stablized polycarbonate cover or toughen glass cover and high power LEDs as light source with LED fittings system Lumen not less than 95 lumen per watt and electronic driver with efficiency 85% with inbuilt protection against lighting, over voltage, short circuit and surge/spike protection upto 5 KV ensuring longer life (THD<10%, PF shall be > 0.95, colour temperature 5700±300K), life expectancy of LEDs minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than three years. The fitting shall be tested in NABL accredited LAB and LM 80 test certificate shall be submitted by the original manufacturer. The light fittings shall be fixed on pole with and including 25 mm dia ( or higher size as per manufacturer recommendation), bracket 1.5 m long complete with MS flat iron clamps (clamp shall be 40x5 mm MS flat), nuts and bolts and washers painting the clamps with coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed. | BI01010001010000000000000515BI0100001135 | 10 | Each |
|---|
| 22 | 22 | Taking down old,rusted, unsv Junction box of any size, type and supply & fix new junction box of size not less than 25Cm x20 Cm x 11 Cm, made out of Fibre material, shockproof and rustproof, cable entry from bottom. 100% wheather proof, restricted to unauthorised tapping with class FV-0 as per IS : 11731 Part-II or V-0 as per UL-94 and fixing to pole etc using suitable clamps nuts, bolts etc for accommodating and including the following complete all as specified and directed :-\na) Four strip Aluminium Bus bar of capacity 100 A , 10 CM long- 01 Set\nb) MCB SP 10A-01 Nos | BI01010001010000000000000515BI0100001136 | 250 | Each |
|---|
| 23 | 23 | S&F in replacement of old unserviceable contactor ML-4, 70 Amps power operating voltage 415 V AC Capacity complete all as specified and directed. | BI01010001010000000000000515BI0100001137 | 4 | Each |
|---|
| 24 | 24 | S&F in replacement of old unserviceable contactor ML-3, 40 Amps power operating voltage 415 V AC Capacity complete all as specified and directed. | BI01010001010000000000000515BI0100001139 | 4 | Each |
|---|
| 25 | 25 | S&F in replacement of old unserviceable contactor ML-2, 32 Amps power operating voltage 415 V AC Capacity complete all as specified and directed. | BI01010001010000000000000515BI0100001140 | 1 | Each |
|---|
| 26 | 26 | S&F in replacement of two run of PVC insulated 2.5 sqmm copper SC conductor cable between cable loops box to fitting drawn through the pole complete all as specified and directed.\nNote: Two run of cable will be measured as one length) | BI01010001010000000000000515BI0100001141 | 630 | RM |
|---|
| 27 | 27 | Taking out the old unsv pole ,Supplying and erecting ( in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces and with blach bituminous paint for embedded portion of pole complete all as specified and directed. | BI01010001010000000000000515BI0100001142 | 2 | Each |
|---|
| 28 | 28 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft/loose soil etc complete all as specified and directed. | BI01010001010000000000000515BI0100001143 | 137.34 | Cum |
|---|
| 29 | 29 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil etc complete all as specified and directed. | BI01010001010000000000000515BI0100001144 | 68.67 | Cum |
|---|
| 30 | 30 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed. | BI01010001010000000000000515BI0100001145 | 141 | Cum |
|---|
| 31 | 31 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point all as directed complete all as specified and directed. | BI01010001010000000000000515BI0100001146 | 65 | Cum |
|---|
| 32 | 32 | Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 10 cm after laying and stretching jointing and testing the cable complete all as specified and directed.\nNote : Measurement will be done after punning | BI01010001010000000000000515BI0100001147 | 61.8 | Cum |
|---|
| 33 | 33 | Supplying and laying un-reinforced precast concrete cable cover, class I, flat, size 250mm x 150mm x 40mm for cable protection placed perpendicular of the cable complete all as specified and directed. | BI01010001010000000000000515BI0100001148 | 4769 | Each |
|---|
| 34 | 34 | M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for pole/stay foundation etc complete all as specified and directed. | BI01010001010000000000000515BI0100001149 | 0.11 | Cum |
|---|
| 35 | 35 | M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation etc complete all as specified and directed. | BI01010001010000000000000515BI0100001150 | 1.08 | Cum |
|---|
| 36 | 36 | M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate etc complete all as specified and directed. | BI01010001010000000000000515BI0100001151 | 0.6 | Cum |
|---|
| 37 | 37 | Supply and fix GI Pipe Light grade with all connected accessories of sizes 40 mm complete all as specified and directed. | BI01010001010000000000000515BI0100001152 | 58 | RM |
|---|
| 38 | 38 | Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix of size 25 Sqmm 4 core complete all as specified and directed. | BI01010001010000000000000515BI0100001153 | 250 | RM |
|---|
| 39 | 39 | Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix of size 16 Sqmm 4 core complete all as specified and directed. | BI01010001010000000000000515BI0100001154 | 270 | RM |
|---|
| 40 | 40 | Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix of size 16 Sqmm 2 core complete all as specified and directed. | BI01010001010000000000000515BI0100001155 | 350 | RM |
|---|
| 41 | 41 | Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix of size 10 Sqmm 2 core complete all as specified and directed. | BI01010001010000000000000515BI0100001156 | 220 | RM |
|---|
| 42 | 42 | Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circulas 4 sqmm complete all as specified and directed. | BI01010001010000000000000515BI0100001157 | 470 | RM |
|---|
| 43 | 43 | Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circulas 6 sqmm complete all as specified and directed. | BI01010001010000000000000515BI0100001158 | 560 | RM |
|---|
| 44 | 44 | Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circulas 10 sqmm complete all as specified and directed. | BI01010001010000000000000515BI0100001159 | 370 | RM |
|---|
| 45 | 45 | Taking down Old unserviceable LT UG cable of service connection or distribution system of any size and removing from site complete all as specified and directed.\nNote: Excavation and earth work will be measured seperately | BI01010001010000000000000515BI0100001160 | 1090 | RM |
|---|
| 46 | 46 | M&L for scrapping of old alum paint of steel tubular pole 9/11 mtr by means of amery paper for preparation of smooth surfaces and painting with two coats of alum paint on pole , brackets old junction boxes channels etc complete all as specified and directed. | BI01010001010000000000000515BI0100001161 | 240 | Each |
|---|
| 47 | 47 | Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following complete all as specified and directed:-\n | BI01010001010000000000000515BI0100001162 | 3 | Each Job |
|---|
| 48 | 47.01 | Copper bus bar 300 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. | BI01010001010000000000000515BI0100001163 | | |
|---|
| 49 | 47.02 | MCCB FP 200 Amps 25 KA - 01 No for main in coming | BI01010001010000000000000515BI0100001164 | | |
|---|
| 50 | 47.03 | MCB 40 Amps TPN, 10 KA - 03 Nos | BI01010001010000000000000515BI0100001165 | | |
|---|
| 51 | 47.04 | MCB 40 Amps SPN, 10 KA - 03 Nos | BI01010001010000000000000515BI0100001166 | | |
|---|
| 52 | 48 | Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified and directed. | BI01010001010000000000000515BI0100001167 | 6 | Each Job |
|---|
| 53 | 49 | S & F GI earth continuity conductor or main earthing lead of size 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as specified and directed. | BI01010001010000000000000515BI0100001168 | 15 | RM |
|---|
| 54 | 50 | Taking old unserviceable driver from LED light fitting and S&F LED outdoor driver with all electricals connection as per existing make complete all as specified and directed. | BI01010001010000000000000515BI0100001169 | | |
|---|
| 55 | 50.01 | for LED light fitting 15-30 Watts | BI01010001010000000000000515BI0100001170 | 10 | Each |
|---|
| 56 | 50.02 | for LED light fitting 60-72 Watts | BI01010001010000000000000515BI0100001171 | 20 | Each |
|---|
| 57 | 50.03 | for LED light fitting 80-120 Watts | BI01010001010000000000000515BI0100001172 | 10 | Each |
|---|
| 58 | 51 | Taking down Old unserviceable service wire of any size and removing from site complete all as specified and directed. | BI01010001010000000000000515BI0100001173 | 500 | RM |
|---|
| 59 | 52 | Repair and maintenance of Solar LED street light fittings 21 W, Solar panel cap 100 Wp, Battery 12 V 100 Ah of type lead acid tubular battery , checking the charge controller rating 12V, 7.5 A including control wiring and the system should be functional with 12 hours automatic switch On/Off and testing complete all as specified and directed.\nNote: All spares replaced will be include under relevant items. | BI01010001010000000000000515BI0100001174 | 20 | Each |
|---|