Repair/Replacement Of Unserviceable Items Pertains To Summer Appliances , Winter Appliances , Split Acs , Window Acs And Other Connected Misc E/M Works Under Ge E/M Base Hospital Delhi Cantt-10, GE E/M BASE HOSP DELHI CANTT-Delhi

Military Engineer Services-MES has published Repair/Replacement Of Unserviceable Items Pertains To Summer Appliances , Winter Appliances , Split Acs , Window Acs And Other Connected Misc E/M Works Under Ge E/M Base Hospital Delhi Cantt-10. Submission Date for this Tender is 03-12-2019. Electromechanical Work Tenders in GE E/M BASE HOSP DELHI CANTT Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

22484684
Repair/Replacement Of Unserviceable Items Pertains To Summer Appliances , Winter Appliances , Split Acs , Window Acs And Other Connected Misc E/M Works Under Ge E/M Base Hospital Delhi Cantt-10
Open Tender
Indian
Delhi
GE E/M BASE HOSP DELHI CANTT
03-12-2019

Tender Details

Repair / Replacement Of Unserviceable Items Pertains To Summer Appliances , Winter Appliances , Split Acs , Window Acs And Other Connected Misc E / M Works Under Ge E / M Base Hospital Delhi Cantt-10

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 48 Lakhs /-

BOQ Items

Name of Work: REPAIR/REPLACEMENT OF UNSERVICEABLE ITEMS PERTAINS TO SUMMER APPLIANCES, WINTER APPLIANCES, SPLIT ACS, WINDOW ACS AND OTHER CONNECTED MISC E/M WORKS UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for taking down carefully and servicing of window type AC of 1.5/2.0 TR capacity, two time in complete contract duration at interval of three month or as directed, in any type/make, at site /wall and removing power connection and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, indoor cooling unit and condenser coil and providing oil and grease to all moving parts including condensing motor, checking and making serviceable electrical connection of DB's, stabilizer, wiring of AC's as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required after testing and commissioning and refixing at the original position and connected with the system complete all as specified and directed. \nNote :- (i) Contractor shall maintain register of servicing as per format given by Engr-in-charge duly signed by User where the servicing of equipment carry out and produce as & when asked by Engr-in-Charge or GE BHDC.\n(ii) Spare parts required for repairs shall be measured and paid separately under respective item of this Schedule as supply only. 135 Each Job
2 2 M&L for servicing of split type AC of 1.5/2.0 TR capacity, two time in complete contract duration, at interval of three month or as directed in any type/make, at site /wall and removing power connection and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil of indoor cooling unit and condenser coil of out door unit and providing oil and grease to all moving parts including condensing motor, checking and making serviceable electrical connection of DB's, stabilizer, wiring of AC's as per site condition and tightening all electrical connection with thimble including taking down carefully and replacing the spare parts of the AC units wherever required, testing and commissioning and refixing in the original position and connecting with the system complete all as specified and directed. \nNote: (i) The cost of additional inlet/outlet copper pipes, drain pipe and electrical cord, if required and making good of surface as original by plastering / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect. \n(ii) Contractor shall maintain register of servicing as per format given by Engr-in-charge duly signed by User where the servicing of equipment carry out and produce as and when asked by Engr-in-charge or GE BHDC.\n(iii) Other spare parts required for repairs shall be measured and paid separately under respective item of this Schedule as supply only.\n 635 Each Job
3 3 All as per srl item No 2 but here-in-before but cassette type of any capacity complete all as specified and directed. 8 Each Job
4 4 Supply only in replacement sealed compressor unit reciprocating type for 1.5 TR window type AC/ Split AC complete all as specified and directed. Make:- Carrier/Bluestar/Hitachi 30 Each
5 5 Supply only in replacement sealed compressor unit rotary type, for 1.5 TR window type AC/ Split AC complete all as specified and directed. Make:- Carrier/Bluestar/Hitachi 50 Each
6 6 All as per srl item No 5 here-in-before but capacity 2.0 TR complete all as specified and directed. Make:- Carrier/Bluestar/Hitachi 12 Each
7 7 S&F in replacement sealed compressor unit rotary type, for 3.0 TR window type AC/ Split AC complete all as specified and directed. Make:- Carrier/Bluestar/Hitachi 4 Each
8 8 Supply only in replacement sealed compressor unit, Scroll type for 1.5TR window type AC/Split AC complete all as specified and directed. Make:- Carrier/Bluestar/Hitachi 25 Each
9 9 All as per srl item No 8 here-in-before but capacity 2.0 TR complete all as specified and directed. Make:- Carrier/Bluestar/Hitachi 25 Each
10 10 Supply only in replacement window AC Kit internal wiring for 1.5 / 2 TR complete all as specified and directed. 10 Each
11 11 All as srl item No 10 here in before but for Split AC of 1.5/2.0 TR capacity complete all as specified and directed. 10 Each
12 12 Supply only in replacement drain pipe PVC medium grade size 32mm dia including fittings complete all as specified and directed. 340 RM
13 13 S&F in repair PCB for split type AC/ window type AC of any capacity and model complete all as specified and directed. 80 Each
14 14 S&F in repair 1.5TR capacity window type AC kit complete including condenser coil, cooling coil, front grill, blower motor, chassis, base plate, Display, Blower, Filter and GI frame housing with power coated colour complete set except compressor suitable for Non CFC gas complete all as specified and directed. Make :Carrier/Bluestar/Hitachi. Note- Old window type AC shall be deposited to MES store yard from existing location. The rate includes necessary transportation & Manpower for dismantling and transporting the unit. 25 Each
15 15 All as per srl item No 14 here-in-before but 2 TR complete all as specified and directed. Make: Carrier/Hitachi/Blue star \nNote- Old window type AC shall be deposited to MES store yard from existing location. The rate includes necessary transportation & Manpower for dismantling and transporting the unit. 25 Each
16 16 S&F in replacement indoor unit complete set for 1.5 TR split AC consist of blower motor, Blower, wiring kit complete with display and electronic card and remote assembly, cooling coil, remoting system, Plastic housing with bracket frame etc except compressor suitable for Non CFC gases complete all as specified and directed. Make: Carrier/Hitachi/Blue star \nNote- Old indoor unit shall be deposited to MES store yard from existing location. The rate includes necessary transportation & Manpower for dismantling and transporting the unit. 25 Each
17 17 S&F in replacement indoor unit complete set for 2.0 TR split AC consist of blower motor, Blower, wiring kit complete with display and electronic card and remote assembly, cooling coil, remoting system, Plastic housing with bracket frame etc except compressor suitable for Non CFC gases complete all as specified and directed. Make: Carrier/Hitachi/Blue star \nNote- Old indoor unit shall be deposited to MES store yard from existing location. The rate includes necessary transportation & Manpower for dismantling and transporting the unit. 25 Each
18 18 S&F in replacement split AC out door unit Kit of 1.5 TR capacity, company made, including metal sheet enclosure, condenser coil, wiring kit, condenser fan motor, condenser fan or blower, PCB, contactor, terminal etc except compressor suitable for Non CFC Gases complete all as specified and directed. Make : Carrier/Hitachi/Blue star. Note- Old outdoor unit shall be deposited to MES store yard from existing location. The rate includes necessary transportation & Manpower for dismantling and transporting the unit. 25 Each
19 19 All as per srl item No 18 here-in-before but 2 TR complete all as specified and directed. Make: Carrier/Hitachi/Blue star \nNote- Old outdoor unit shall be deposited to MES store yard from existing location. The rate includes necessary transportation & Manpower for dismantling and transporting the unit. 25 Each
20 20 Supply only starting capacitors 80-100 MFD complete all as specified and directed. Make - Asian/Epcos/Havells. 2 Each
21 21 Supply only starting capacitors 120 MFD complete all as specified and directed. Make - Asian/Epcos/Havells. 2 Each
22 22 Supply only running capacitor 50+6 MFD complete all as specified and directed. Make - Asian/Epcos/Havells. 180 Each
23 23 Supply only running capacitor 45+4 MFD Make - Asian/Epcos/Havells. 10 Each
24 24 Supply only condenser Motor 1/5 HP suitable for window type AC double shaft complete all as specified & directed. Make:- LG/Carrier or equivalent 9 Each
25 25 Supply only starting relay SR-1622 complete all as specified and directed. 5 Each
26 26 Supply only cooling coil made out of copper tube of window AC 1.5/2.0 Ton complete all as specified and directed. 18 Each
27 27 Supply only condenser coil made out of copper tube complete of window AC 1.5/2.0 TR as per existing system complete all as specified and directed. 20 Each
28 28 Supply only over load protector relay for WAC / SAC of capacity 1.5TR / 2TR complete all as specified and directed. 2 Each
29 29 S&F in repair sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 20 Amps, 240 Volts complete all as specified and directed.\nMake:- Legrand/ Havells/Schneider. 100 Each
30 30 Supply only in replacement PVC insulated multi stranded 3 core flexible cable of size 70 x 76 complete all as specified and directed. Make:- Plaza/Finolex/Havells. 100 RM
31 31 Material & Labour for charging compatible refrigerant gas after pressure test with Nitrogen to compressor for window type 1.5TR Capacity complete all as specified and directed. 58 Each Job
32 32 All as per srl item No 31 but here-in-before 2 TR capacity window type complete all as specified and directed. 8 Each Job
33 33 All as per srl item No 31 but here-in-before split type AC 1.5 TR capacity complete all as specified and directed. 160 Each Job
34 34 All as per srl item No 31 but here-in-before split type AC 2.0 TR capacity complete all as specified and directed. 12 Each Job
35 35 Supply only in replacement front grill of window AC as per sample & suit to existing model for window type AC 1.5TR capacity complete all as specified and directed. 8 Each
36 36 All as per srl item No 35 but here-in-before 2 TR capacity window type AC complete all as specified and directed. 4 Each
37 37 All as per srl item No 35 here-in-before but split type AC upto 2 TR complete all as specified and directed. 30 Each
38 38 M&L for making necessary arrangement/alteration to make reversible system (reverse valve) to functioning as heat engine in winter i.e. winter heating and cooling in summer by providing necessary copper tubing, refrigerant valve modification in remote unit (PCB) and allied work for the split / window Air Conditioner of capacity 1.5/2.0 TR complete all as specified and directed. Note: Charging of refrigerant gas, if required, shall be measured and paid separately. 65 Each
39 39 Attending the break down / complaint of all nature for window and split AC and their electrical wiring from main DBs of any capacity and make them functional and also carry out the required repair on all days including Sunday and holidays complete all as specified and directed. Note-(i) Store required for repairs shall be measured and paid separately under respective item of this Schedule as supply only. (ii) Adequate resources will be deployed by the contractor for attending day to day defect being an essential installation. (iii) All complaint/repairs shall be attended within 06 Hour failing which a recovery of Rs 500/- per day shall be made from contractor dues. 900 Each Job
40 40 Supply only in replacement copper pipe ½” dia, wall thickness 0.032 mm including insulation complete all as specified & directed. 200 RM
41 41 All as per srl item No 40 here-in-before but 1/4" dia, wall thickness 0.030 mm including insulation complete all as specified & directed. 200 RM
42 42 S&F in repair out door stand for split AC complete all as specified and directed. 30 Each
43 43 Supply only in replacement Split AC Indoor Unit blower motor 36 Watt single shaft complete all as specified and directed. Make:- LG/Carrier/Blue star/Hitachi 18 Each
44 44 Supply only in replacement Split AC display complete all as specified and directed. Make-LG/Blue star/Carrier. 18 Each
45 45 Supply only in repair plug top 3 pin 5 Amps complete all as specified & directed. Make-Anchor/Havells/Cona. 50 Each
46 46 Supply only in replacement plug top 3 pin 15 Amps complete all as specified & directed. Make- Anchor/Havells/Cona. 50 Each
47 47 Supply only in replacement Split AC condenser fan motor 1/5 HP Single shaft complete all as specified and directed. 15 Each
48 48 Supply only in replacement Indoor unit Air blower motor for Split 2 TR complete all as specified and directed. 4 Each
49 49 Supply only in replacement Window AC air blower motor 1.5TR/2TR complete all as specified and directed. 2 Each
50 50 Supply only in replacement fan blade for Split AC Condenser of capacity 1.5TR/2 TR complete all as specified and directed. 8 Each
51 51 Supply only in replacement capacitor 4 MFD complete all as specified and directed. Make :- Asian/Epcos/Havells 50 Each
52 52 Supply only in replacement Capacitor 6 MFD complete all as specified and directed. Make:- Asian/Epcos/Havells 4 Each
53 53 Supply only in replacement capacitor 2.5 MFD complete all as specified and directed. Make- Epcos/ Asian /Tiscon\n\n 20 Each
54 54 Supply only in replacement 4 mm thick ply wood in windows for desert cooler / window type air conditioner complete all as specified and directed. 40 Sqm
55 55 S&F in repair PVC insulated multi stranded 3 core flexible cable of size 40 x 76 complete all as specified and directed. Make:- Plaza/Finolex/Havells. 150 RM
56 56 S&F in repair copper tubing 5/8" dia & wall thickness 0.035mm including insulation complete all as specified & directed. 80 RM
57 57 S&F in repair copper tubing 3/8" dia & wall thickness 0.032 mm including insulation complete all as specified and directed. 80 RM
58 58 M&L for shifting of Split type AC of any capacity, any type/make, with stabilizer including taking down carefully indoor and outdoor unit, copper piping, drain pipe and thermal sleeve, lifting angle etc and installing the same to new location using existing copper piping for suction and delivery with insulation, drain pipe and re-fixing arrangement i. e. lifting angle, fasteners, nut bolt, washer etc, testing & commissioning, complete all as specified and directed.\nNote: (i) The cost of making hole for passing through inlet/outlet copper pipes, drain pipe and electrical cord and making good of surface at both location as original by plastering / whitewash / colour / distemper etc is deemed to be included in quoted rate and no extra payment will be made to contractor on this account. \n(ii) The additional copper piping, if required shall be measured and paid separately under respective items of this Sch. 40 Each Job
59 59 M&L for shifting of window type AC of any capacity, any type/make, with stabilizer from one location to another complete with and including making of suitable opening in brick wall or removing aluminium grill and/or glass pane from existing window, including supply and fixing of new wooden frame of suitable size and thickness for proper fixing of outer chassis of AC at new location, making good of disturbed surface as original etc testing & commissioning complete all as specified and directed. \nNote: The cost of making suitable opening in brick wall or removing aluminium grill and/or glass pane from existing window and making good of surface at both location as original by plastering / whitewash / colour / distemper etc shall deemed to be included in quoted rate and no extra payment shall be made to contractor on this account. 25 Each Job
60 60 M & L Sub main wiring using two single core PVC insulated FRLS cable 4.0 Sqmm copper conductor multi stranded and 4.0 Sqmm copper conductor insulated cable using as earth wire and drawing in and including 25mm PVC conduit medium grade complete all as specified and directed. \nNote: Two runs of 4.0 Sqmm copper FRLS cable & one run of 4.0 Sqmm copper cable in and including 25mm PVC conduit medium grade shall be measured as one unit. 150 Per RM
61 61 M & L Sub main wiring using two single core PVC insulated FRLS cable 6.0 Sqmm copper conductor multi stranded and 6.0 Sqmm copper conductor insulated cable using as earth wire and drawing in and including 25mm PVC conduit medium grade complete all as specified and directed. \nNote: Two runs of 6 Sqmm copper FRLS cable & one run of 6.0 Sqmm copper cable in and including 25mm PVC conduit medium grade shall be measured as one unit. \n 100 Per RM
62 62 M & L sub main wiring using four run PVC insulated FRLS Copper conductor 10.00 Sqmm drawing in and including rigid non metallic PVC conduit of size 32 mm dia, medium grade inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with saddles PVC with earth continuity wire copper conductor PVC insulated unsheathed 10 Sq mm etc complete all as specified and directed. \nNote: Four runs of 10.00 Sqmm copper FRLS cable & one run of 10.00 Sqmm copper cable in and including 32mm PVC conduit medium grade shall be measured as one unit. 50 Per RM
63 63 S & F in repair distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN 8 way with 250 Amps rated copper bus bar, 415 Volts with in built MCCB 160 Amps, 16 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 507747 or equivalent model of Siemens/ Schneider. 5 Each
64 64 S & F in repair distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN 4 way with 250 Amps rated copper bus bar, 415 Volts with in built MCCB 125 Amps, 16 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 5077 45 or equivalent in Siemens/ Schneider 5 Each
65 65 S & F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 100 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 10 or equivalent in Siemens / Schneider 10 Each
66 66 S & F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 100 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 11 or equivalent model of Siemens / Schneider 10 Each
67 67 S &F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 100 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 12 or equivalent model of Siemens / Schneider 8 Each
68 68 S & F in repair with taking down distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN 12 way with 250 Amps rated copper bus bar, 415 Volts with in built MCCB 160 Amps, 16 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 5077 48 or equivalent model of Siemens/ Schneider 8 Each
69 69 S & F in repair MCCB 415 V, 160 Amps, 25 KA, 3 Pole complete all as specified and directed. Make - Legrand Cat part No 4200 47 or equivalent model of Siemens/ Schneider 8 Each
70 70 S & F in repair MCCB 415 V, 100 Amps, 25 KA, 3 Pole complete all as specified and directed. Make - Legrand Cat part No 4200 45 or equivalent model of Siemens/ Schneider 6 Each
71 71 S & F in repair MCCB 415 V, 200 Amps, 25 KA, 3 Pole complete all as specified and directed. Make - Legrand Cat part No 4200 08 or equivalent model of Siemens/ Schneider 6 Each
72 72 S & F in repair MCB, SP, 240 Volts, 6 to 40 Amps complete all as specified and directed.\n Make- Havells/Legrand/Standard 150 Each
73 73 S & F in repair MCB, SP, 240 Volts, 63 Amps complete all as specified and directed. Make- Havells/Legrand/Standard 100 Each
74 74 S & F in repair MCB, SPN, 240 Volts, 32 Amps complete all as specified and directed. Make- Havells/Legrand/Standard 20 Each
75 75 S & F in repair MCB, SPN, 240 Volts, 40 to 63 Amps complete all as specified and directed. Make- Havells/Legrand/Standard 20 Each
76 76 S & F in repair MCB, TPN, 415 Volts, 63 Amp complete all as specified and directed.\nMake- Havells/Legrand/Standard 4 Each
77 77 M&L in repair Earthing complete with galvanised iron earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of the plate not less than 1.5mtr below normal GL, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and riveted to earth plate at one end and connected to main DBs of Bldg at another end. GI earth wire encased in and including 15mm dia GI light grade pipe through upper end of earth plate up to main DB of bldg with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150mm centre to centre both ways complete with lifting handle all as shown in electrical plate no 5 of SSR of part-I (1991) complete all as specified and directed. 12 Each
78 78 S&F wall mounted digital Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150V - 285 V\nwith output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 4 KVA complete all as specified and directed. Make: V-Guard model No VND 400 or equivalent model of Bluebird, Emerson \nNote - Old dismantled voltage stabilizer shall be deposited to MES store yard from existing location. The rate include necessary transportation & Manpower for dismantling and transporting the unit. 100 Each
79 79 Supply only in replacement industrial type metal clad socket only of 20 Amps complete all as specified and as directed. Make- Havells/Legrand/Standard 80 Each
80 80 Supply only in replacement metal clad top 20 Amp complete all as specified and as directed. Make- Havells/Legrand/Standard 80 Each
81 81 S&F Single phase motor starter switch 25 A, 220-240 V, AC, 50 Hz complete all as specified and as directed. Make: Havells /Anchor/L&T 150 Each
82 82 S&F Single phase motor starter switch 20 A, 220-240 V, AC, 50 Hz complete all as specified and as directed. Make: Havells /Anchor/L&T 150 Each
83 83 Supply, installation, testing and commissioning complete indoor unit for tower type split AC of 3.5 TR, inclusive of blower motor, blower, wiring kit with cooling coil etc, suitable for R-22 Gas, including sheet metal enclosure (DB), terminal etc including all copper tubing of required size & electrical cabling all as required as per site complete all as specified and directed. Make: Model No- 42KFJ042518 of Carrier or equivalent model of Blue star/Voltas/Hitachi. \nIndoor Unit Technical specification- Nominal cooling cap -3.5 TR, Performance rating-42000 BTU/Hr, Indoor fan motor-300 watt, Indoor air flow-1700 Cum/hr, Dimension(WXDXH): 540x410x1825. Gross weight: 70 KG, Operating temp.- > 17 °C, Controller-Remote Control. \nNote - Old dismantled indoor unit of any capacity and size shall be deposited to MES store yard from existing location. The rate includes necessary transportation & Manpower for dismantling and transporting the unit. 5 Each
84 84 Supply, installation, testing and commissioning complete outdoor unit for Tower type split AC of 3.5 ton, with compressor, suitable for R-22 Gas, condenser coil, wiring kit , condenser fan motor, condenser fan, terminal etc also making platform for outdoor unit with suitable size of fastener and MS frame work and making good the disturb surface including all copper tubing of required size, control wiring all as required as per site complete all as specified and directed. Make: Model No- 38KFJ042518 of Carrier or equivalent model of Blue star/Voltas/Hitachi. \nOutdoor Unit Technical specification- Power Supply- 3 phase, 380 Volt, 50 Hz, Outdoor fan motor-290 watt, Fan motor speed-830 RPM, Dimensions(WXDXH): 990X345X965, Gross weight - 93 KG, Refrigerant piping-Max pipe lenght-20 mtr, Max difference in level-10 mtr \nNote - Old dismantled outdoor unit of any capacity and size shall be deposited to MES store yard from existing location. The rate include necessary transportation & Manpower for dismantling and transporting the unit. 5 Each
85 85 Supply, installation, testing and commissioning complete indoor unit for tower type split AC of 4.6 TR, inclusive of blower motor, blower, wiring kit with cooling coil etc, suitable for R-22 Gas, including sheet metal enclosure (DB), terminal etc including all copper tubing of required size & electrical cabling all as required as per site complete all as specified and directed. Make: Model No- 42KFJ055518 of Carrier or equivalent model of Blue star/Voltas/Hitachi. \nIndoor Unit Technical specification- Nominal cooling cap -4.6 TR, Performance rating-55000 BTU/Hr, Indoor fan motor-300 watt, Indoor air flow-2300 Cum/hr, Dimension(WXDXH): 610x390x1925. Gross weight: 80 KG, Operating temp.- > 17 °C, Controller-Remote Control. \nNote - Old dismantled indoor unit of any capacity and size shall be deposited to MES store yard from existing location. The rate include necessary transportation & Manpower for dismantling and transporting the unit. 2 Each
86 86 Supply, installation, testing and commissioning complete outdoor unit for Tower type split AC of 4.6 ton, with compressor, suitable for R-22 Gas, condenser coil , wiring kit , condenser fan motor, condenser fan, terminal etc also making platform for outdoor unit with suitable size of fastener and MS frame work and making good the disturb surface including all copper tubing of required size, control wiring all as required as per site complete all as specified and directed. Make: Model No- 38KFJ055518 of Carrier or equivalent model of Blue star/Voltas/Hitachi. \nOutdoor Unit Technical specification- Power Supply- 3 phase, 380 Volt, 50 Hz, Outdoor fan motor-148 watt, Fan motor speed-800 RPM, Dimensions(WXDXH): 900X350X1170, Gross weight - 108 KG, Refrigerant piping-Max pipe lenght-20 mtr, Max difference in level-10 mtr.\nNote- Old taking down outdoor unit of any capacity and size shall be deposited to MES store yard from existing location .The rate include necessary transportation & Manpower to dismantling and transporting the unit. 2 Each
87 87 Supply, installation, testing and commissioning complete indoor unit for tower type split AC of 2.8 TR, inclusive of blower motor, blower, wiring kit with cooling coil etc, suitable for R-22 Gas, including sheet metal enclosure (DB), terminal etc including all copper tubing of required size & electrical cabling all as required as per site complete all as specified and directed. Make: Model No- 42KFJ036518 of Carrier or equivalent model of Blue star/Voltas/Hitachi. \nIndoor Unit Technical specification- Nominal cooling cap -2.8 TR, Performance rating-33000 BTU/Hr, Indoor fan motor-300 watt, Indoor air flow-1700 Cum/hr, Dimension(WXDXH): 540x410x1825. Gross weight: 68 KG, Operating temp.- > 17 °C, Controller-Remote Control. \nNote - Old dismantled indoor unit of any capacity and size shall be deposited to MES store yard from existing location. The rate include necessary transportation & Manpower for dismantling and transporting the unit. 5 Each
88 88 Supply, installation, testing and commissioning complete outdoor unit for Tower type split AC of 2.8 ton, with compressor, suitable for R-22 Gas, condenser coil, wiring kit, condenser fan motor, condenser fan, terminal etc also making platform for outdoor unit with suitable size of fastener and MS frame work and making good the disturb surface including all copper tubing of required size, control wiring all as required as per site complete all as specified and directed. Make: Model No- 38KFJ036518 of Carrier or equivalent model of Blue star/Voltas/Hitachi. \nOutdoor Unit Technical specification- Power Supply- 3 phase, 380 Volt, 50 Hz, Outdoor fan motor-162 watt, Fan motor speed-860 RPM, Dimensions(WXDXH): 900X315X860, Gross weight - 66 KG, Refrigerant piping-Max pipe lenght-20 mtr, Max difference in level-10 mtr\nNote- Old taking down outdoor unit of any capacity and size shall be deposited to MES store yard from existing location. The rate include necessary transportation & Manpower to dismantling and transporting the unit. 5 Each