Preventive And Breakdown Maintenance Of Hp Lp Valves Of Turbine Side Of Unit 6 And 7 2X500 Mw Dtps Anpara, Anpara-Uttar Pradesh

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published Preventive And Breakdown Maintenance Of Hp Lp Valves Of Turbine Side Of Unit 6 And 7 2X500 Mw Dtps Anpara. Submission Date for this Tender is 16-12-2019. Valve Tenders in Anpara Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

22468039
Preventive And Breakdown Maintenance Of Hp Lp Valves Of Turbine Side Of Unit 6 And 7 2X500 Mw Dtps Anpara
Open Tender
Indian
Uttar Pradesh
Anpara
16-12-2019

Tender Details

Preventive And Breakdown Maintenance Of Hp Lp Valves Of Turbine Side Of Unit 6 And 7 2X500 Mw Dtps Anpara

Key Value

Document Fees
INR 1180 /-
EMD
INR 18000.0 /-
Tender Value
INR 9 Lakhs /-

BOQ Items

Name of Work: < Preventive & Breakdown Maintenance of HP/ LP Valves of Turbine side of Unit # 6&7, 2X500 MW, ‘D’TPS, Anpara >
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Servicing of Isolating Valve, Control Valve & NRVs of Condensate Line, TDBFP Extraction, Extraction-5 and Booster Pump Suction Line; Size: 400 mm, Class: 150 to 300. item1 6 No.
2 2 Servicing of Isolating Valve, Control Valve & NRVs installed on BFP discharge, Feed Discharge Line, HPH Inlet/ Outlet, HPH 50% Bypass and other similar valve; Size: 350 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC. item2 1 No.
3 3 Servicing of HPH 100% Bypass valve and Feed water inlet to Economiser of Size: 500 mm, Class:2850 item3 1 No.
4 4 Servicing of BFP Recirculation Line Control Valve; Size: 200 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC. item4 1 No.
5 5 Servicing of BFP Recirculation Line Isolating Valve and SCNRV; Size: 200 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC. item5 4 No.
6 6 Servicing of Isolating Valve and Control Valve from Main Steam Line to Auxiliary Steam Header; Size: 200 mm, Class: 2750 SPL Design press.: 188.5 Kg/cm2, temp.: 545 oC. item6 1 No.
7 7 Servicing of Main Steam Control Valve to Aux Steam Header; Size: 350 mm, Class: 3500 Design press.: 188.5 Kg/cm2, temp.: 545 oC. item7 1 No.
8 8 Servicing of Isolating, Control Valve and SCNRVs installed on Aux Steam, Extraction Steam to Deaerator, Extraction Steam to TDBFPs, Extraction Steam to LPH-3; Size: 500 mm, Class: 150 to 300 Design press. <40 Kg/cm2, temp.<330 oC. item8 2 No.
9 9 Servicing of CEP Suction Valve; Size: 500 mm, Class: 150, Operating press.:<40 Kg/cm2 Vacuum, temp.:55 oC. item9 2 No.
10 10 Servicing of Isolating Valve and SCNRV from CRH to Dea Pegging line; Size: 800 mm, Class: 600, Design Press.: 54 Kg/cm2, temp.:360 oC. item10 1 No.
11 11 Servicing of Isolating Valve from CRH to Dea Pegging; Size: 300 mm, Class: 1500, Design Press.: 54 Kg/cm2, temp.:360 oC. item11 1 No.
12 12 Servicing of Extraction Steam Valve or NRV to LPH-2; Size: 800 mm, Class: 150, Design Press.: Vacuum, temp.:135 oC. item12 1 No.
13 13 Servicing of motor operated control valve, motor operated gate/ globe valves, manually operated gate/ globe valves, check valves; Size:300~350 mm, Class: 150 to 300, Design Pr.< 40 Kg/cm2 and temp.:350 oC. item13 4 No.
14 14 Servicing of HP Bypass spray water control valves, spray isolation valves, NRVs on Turbine side. Size:100-150 mm, Class: 2500, Pr. : 320 Kg/cm2 and temp.:185 oC. item14 2 No.
15 15 Servicing of HP Bypass Warm up line regulating valves, Isolation valves, NRVs and other similar valve; Size:50 to 80 mm, Class: 3000 special, Pr.: 188.2 Kg/cm2 and temp.:545 oC. item15 2 No.
16 16 Servicing of turbine MAL drain valves (MAL-11, MAL-12, MAL-22, MAL-26, MAL-27, MAL-31, MAL-32, MAL-47, MAL-51, MAL-52, MAL-54, MAL-55, MAL-65, MAL-81, MSV-105, MSV-106, HRHV-105, HRHV-106) and othe similar valves. item16 5 No.
17 17 Servicing of Isolating valve and control valve of Feed Control Station Size:250 mm, Class: 2500, Pr. : 320 Kg/cm2 and temp.:260 oC. item17 1 No.
18 18 Servicing of Isolating valve, control valve and NRVs of Size:250 mm, Class: 150-600. item18 4 No.
19 19 Servicing of Isolating valve, control valve and NRVs of Size:150 mm to 200 mm, Class: 1500, Pr. : 54 Kg/cm2 and temp.:360 oC. item19 4 No.
20 20 Servicing of Isolating valve, control valve and NRVs of Size:150 mm to 200 mm, Class: 150-600. item20 600 mm
21 21 Servicing of Isolating valve, control valve and NRVs of Size:40 mm to 50 mm, Class: 1500 to 2500. item21 15 No.
22 22 Servicing of Isolating valve; Size:25 mm, Class: 3000 SPL. item22 1 No.
23 23 Servicing of HP Evacuation valve. item23 1 No.
24 24 Servicing of Hydraulic Operated Vacuum Breaker Valve. item24 1 No.
25 25 Servicing of Fisher make EDR & ETR Series Control valve for TDBFP oil system and Stroke Adjustment of the same. item25 1 No.
26 26 Servicing of Change over valve for Coolers and Filters of BFPs. item26 1 No.
27 27 Servicing of Isolating valve, control valve and NRVs of Size: 15 mm to 100 mm, Class: 1500. item27 500 mm
28 28 Servicing of Isolating valve, control valve and NRVs installed on LP lines and oil lines; Size: 15 mm to 100 mm; Class: up to 800. item28 500 mm
29 29 Replacement of LP valves of different Floors by cutting of damaged valve & arc welding of new valve. Size: 15~50 mm. item29 500 mm
30 30 Replacement of HP line drain valves of different Floors by cutting of damaged valve & welding of new valve. Size: 15~50 mm. item30 1 No.
31 31 Replacement of HP line valves of different Floors by cutting of damaged valve & welding of new valve. Size: 40~65 mm. item31 1 No.
32 32 Replacement of HP valves of Feed Water/ Main Steam Line/ CRH Line/ HRH Line etc; size Nb-65~150 mm. item32 1 Jobs
33 33 Replacement of LP Valves of size Nb-300 mm, Pressure rating < 40 Kg/cm2. item33 1 Jobs
34 34 Replacement of LP Valves of Nb-250 mm, Pressure Rating < 40 Kg/cm2. item34 1 Jobs
35 35 Replacement of LP Valves of Nb-350 mm, Pressure Rating < 40 Kg/cm2. item35 1 Jobs
36 36 Replacement of Heater Level Control Valves of Pressure Rating < 40 Kg/cm2. item36 2 Jobs
37 37 High Pressure Argon/ Arc Welding by IBR Welder. item37 15 Jobs
38 38 Replacement of butt welded gate / globe valves of LP lines. Size: 80-100 mm. item38 2 No.
39 39 Repair/ Replacement of LP/HP piping by cutting & welding on per mm ID basis. item39 100 mm
40 40 Replacement of flange type gate / globe valves of LP lines; Size: 75 -100 mm. item40 2 No.
41 41 Replacement of flange gasket of HP/ LP valves & piping on per mm dia. basis of valve. item41 1000 mm
42 42 Replacement of gland packing of HP / LP Valves on per mm dia. basis of valve. item42 2000 mm
43 43 Replacement of HP / LP Heater manhole flange gasket. item43 2 No.
44 44 Servicing of Safety valve of Booster pump suction, CEP suction, Condensate Side of LPHs, Valve gland sealing & Control fluid room. item44 2 No.
45 45 Servicing of Safety valve of HP Heater, Deaerator & FST, HT&LT Header of Aux. PRDS & TDBFP Inlet Steam line. item45 2 No.
46 46 Servicing of Safety valve of Feed Water Line of HP Heaters. item46 2 No.
47 47 Revisioning / Servicing of Butterfly valves; Size: 65 mm to 250 mm. item47 750 mm
48 48 Revisioning / Servicing of Butterfly valves; Size: 300 mm to 800 mm. item48 8000 mm
49 49 Revisioning / Servicing of TDBFP Exhaust Butterfly valves; Size: 1600 mm. item49 1 No.
50 50 Revisioning / Servicing of Condenser inlet/ outlet Butterfly valves; Size:2200 mm. item50 1 No.
51 51 Revisioning / Servicing of NRV installed on ACW line & ECW line; Size: 300 mm to 500 mm. item51 5000 mm
52 52 Servicing of gear boxes of butterfly valves installed on ACW & ECW System. Valve Size: 65~250 mm. item52 10 No.
53 53 Servicing of gear boxes of butterfly valves installed on ACW & ECW System. Valve Size: 300 to 600 mm. item53 25 No.
54 54 Servicing of gear boxes of butterfly valves installed on ACW System. Valve Size: 800 mm. item54 1 No.
55 55 Servicing of gear boxes of butterfly valves Size: 1600 mm. item55 1 No.
56 56 Servicing of gear boxes of butterfly valves Size: 2200mm. item56 1 No.
57 57 Revisioning / Servicing of Ball Collector of Condenser Tube Cleaning System. item57 4 No.
58 58 Inspection/ Minor repairing of ball catch strainer of condenser tube cleaning system installed inside CW return line of size: 2200 mm. item58 2 No.