Provision Of Deficient Otm Accn Including Ancillaries At Dappar
Tender Value
4 Crore
Estimated cost
Bid Submission
14 Dec 2019
0 days left
EMD
4.75 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dappar → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Provision Of Deficient Otm Accn Including Ancillaries At Dappar
BOQ
| Name of Work: PROVISION OF DEFICIENT OTM ACCN INCLUDING ANCILLARIES AT DAPPAR | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Lump Sum amount worked out by the contractor for \"Builidng Works\" as listed in Schedule 'A' Section-I | BI01010001010000000000000515BI0100001113 | 1 | Each |
| 2 | 2 | Lump Sum amount worked out by the contractor for \"Site Development & Misc Earth Works\" as listed in Schedule 'A' Section-II | BI01010001010000000000000515BI0100001114 | 1 | Each |
| 3 | 3 | Lump Sum amount worked out by the contractor for \"Internal Electrification works\" as listed in Schedule 'A' Section-III | BI01010001010000000000000515BI0100001115 | 1 | Each |
| 4 | 4 | Lump Sum amount worked out by the contractor for \"Internal Water Supply Works\" as listed in Schedule 'A' Section-IV | BI01010001010000000000000515BI0100001116 | 1 | Each |
| 5 | 5 | Lump Sum amount worked out by the contractor for \"Sewage Disposal Works\" as listed in Schedule 'A' Section-V | BI01010001010000000000000515BI0100001117 | 1 | Each |
| 6 | 6 | Lump Sum amount worked out by the contractor for \"Area Drainage Works\" as listed in Schedule 'A' Section-VI | BI01010001010000000000000515BI0100001118 | 1 | Each |
| 7 | 7 | Lump Sum amount worked out by the contractor for \"Road, Path & Hardstanding Works\" as listed in Schedule 'A' Section-VII | BI01010001010000000000000515BI0100001119 | 1 | Each |
| 8 | 8 | Lump Sum amount worked out by the contractor for \"External Water Supply Works\" as listed in Schedule 'A' Section-VIII | BI01010001010000000000000515BI0100001121 | 1 | Each |
| 9 | 9 | Lump Sum amount worked out by the contractor for \"External Electric Supply & Lightening Protection Works\" as listed in Schedule 'A' Section-IX | BI01010001010000000000000515BI0100001122 | 1 | Each |
| 10 | 10 | Lump Sum amount worked out by the contractor for \"Dismantling/ Demolition Works\" as listed in Schedule 'A' Section-X | BI01010001010000000000000515BI0100001123 | 1 | Each |
| 11 | 11 | Schedule 'A'Section-XII (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 siginifies this fact only. | BI01010001010000000000000515BI0100001124 | ||
| 12 | 12 | ROAD, PATH, HARD STANDING & SIGN BOARD WORKS | BI01010001010000000000000515BI0100001127 | ||
| 13 | 13 | Item No. 1 Corrosion free stainless steel pipe (any section of pipe) of 16 gauge round/square of grade 304 as in framed work for sign boards & similar work including cutting, bending, welding and legs embedded in PCC after excavation complete all as specified and directed by engineer-in-charge. \nNote : Excavation and PCC will be measured and paid separately. | BI01010001010000000000000515BI0100001129 | 90 | Kilogram |
| 14 | 14 | Item No. 2 High density retro reflective sign board made of hardened ACP sheet 2mm thick, pop riveted to stainless steel pipes as required. Sign boards should be reflective both sides with wide HIP sheet and overlay film of blue/green/colour with computer cut letter /sign and border made of high intensity grade white/yellow sheeting and mechanically fixed on ACP sheet complete all as specified and diredted by Engineer-in-Charge. \nNote : (i) Stainless steel framework shall be measured and paid separately under relevant item. \n(ii) The rate shall include all computerized lettering of any height , width and any Nos and may consist of letter, symbols or alphabets in any pattern and of any size etc complete as per data provided during execution. \n(iii) The sign board shall be manufactured as per sample kept in GE (P) office (iv) contractor are advised to inspect the sample kept of GE's office on any working day before quoting their rates. No claim on this account shall be entertined at later stage. | BI01010001010000000000000515BI0100001130 | 10 | Square Metre |
| 15 | 15 | SUMMER AND WINTER APPLIANCES \n | BI01010001010000000000000515BI0100001131 | ||
| 16 | 16 | Item No. 3 Supply, installation, testing and commissioning of self standing Water cooler fully stainless steel, electric driven single phase 230 Volts, 50 Hz having storage capacity of 80 Ltrs and nominal cooling capacity of 40 Ltrs wit Suitable compressor, ecco friendley R 134A refrigernt, externally mounted thermostat for easy regulating temperature with extra large stainless steel water tray for fast drainage of water complete all as specified. | BI01010001010000000000000515BI0100001132 | 3 | Each |
| 17 | 17 | Item No. 4 Supply, installation, testing and commissioning Desert Air cooler, electric driven single phase having having nominal air flow capacity of 4000 CuM per hour factory made out of 2mm thick MS sheet powder coated, electric driven capacity 170w, 230V (single phase ), having approx storage capacity of 60 Ltrs with MS fabricated stand made out of 40 x 40 x 5mm angle frame duly grouted in wall, painted 2 coats of synethetic anamel paint over a coat of red oxide for placing desert Air Cooler,fan motor, tolly pump, rotary switch complete all as directed. | BI01010001010000000000000515BI0100001133 | 30 | Each |
| 18 | 18 | Item No. 5 Supply, installation, testing and commissioning voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input varriation between 170 V to 250 V with output voltage stablized at 230 V with accuracy of + 2.5% and of capacity 2.0 KVA, complete all as directed. | BI01010001010000000000000515BI0100001134 | 4 | Each |
| 19 | 19 | Item No. 6 Supply, installing, testing and commissioning, voltage stabilizer for automatic operation, single phase naturally air cooled inddoe type and designed for input variation between 170 V to 250 V with outlet voltage stabilized at 230 V with accuracy of + 2.5% and capacity 1.0 KVA, complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001135 | 2 | Each |
| 20 | 20 | Item No. 7 Supply, installation, testing and commissioning of aesthetically designed Glass Top Deep Freezer double sliding door electric driven single phase 240 volt, 50 Hz up to 320 litre capacity BEE 5 star rated and equivalent latest EER/ISEER rating with an adjustable working temperature from -12 °C to - 22 °C ecco friendley refrigerent R134A, Anodised Stucco Aluminium inner cabinet, Low Emissive Toughened Glass for top lid, PUF Thickness upto 70 mm and heavy duty castors for easy mobility all as specified. | BI01010001010000000000000515BI0100001139 | 1 | Each |
| 21 | 21 | Item No. 8 Supply, installation,testing and commissioning free standing Refrigerator, electric driven (single phase) 50 Hz ,of capacity 240 Litres, BEE 5 star rated and equivalent latest EER/ISEER rating, smart Invertor Compressor that performs an energy efficient performance. It offers a Smart Diagnosis System and an Auto Connect Feature and has an anti- bacterial gasket, moist balance crisper along with a humidity controller, LED indicator, door opening cabin light and warning alarm. It will have the provision of stainless steel handle with locking arrangement and deep frozt system with all accessories egg tray vegtable tray etc comple as specified.\nMake : LG/ Samsung/ Whirlpool. | BI01010001010000000000000515BI0100001140 | 2 | Each |
| 22 | 22 | Item No. 9 Angle iron frame for supporting desert coolers made to shape out of 40x40x5mm equal angle iron fixed with arc welding or fastening with nuts and bolts all as per site requirement & directed. The MS structure shall be painted with two coats of synthetic enamel black paint over one coat of red oxide after through cleaning of surface, complete all as specified and directed. | BI01010001010000000000000515BI0100001141 | 3 | Qtl |
| 23 | 23 | Item No. 10 Supply, installation,testing and commissioning of Water heater storage type, electric driven 215Volts 50Hz single phase capacity 25 litres 2000Watts BEE 5 star rated and equivalent latest EER/ISEER rating, with over heat auto cut-off thermostat provision , energy saving high quality PUF insulation, Adjustable knob for temperature settings between 25 degree C to 75 degree C to get the desired temperature. Inner tank made of extra thick superior cold rolled steel, Earth leakage circuit breaker (ELCB) with all connected flexible pipes and other accessorie for fixxing, complete all as specified and directed. | BI01010001010000000000000515BI0100001142 | 2 | Each |
| 24 | 24 | EXTERNAL WATER SUPPLY | BI01010001010000000000000515BI0100001143 | ||
| 25 | 25 | Item No. 11 Cutting of existing CI pipe line 100 mm dia and inserting tee 100x100x80mm for taking branch connection all as directed including threading, excavation and earth work etc, complete all as specified and as directed by Engr-in-Charge. | BI01010001010000000000000515BI0100001144 | 1 | Job |
| 26 | 26 | Item No. 12 CI sluice valve class PN 1.6 conforming to IS 14846-2000, suitable for 80mm bore of pipe, with iron wheel at top and brass spindle, flanged both ends including rubber joints, nuts, bolts gasket and washers and testing complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001145 | 1 | Each |
| 27 | 27 | Item No. 13 Construction of brick masonary valve pits of size 900 mm x 900 mm x 900 mm (internal dimension of chamber), depth of chamber to be recokoned from the top of PCC in foundation to top of MS cover as shown in drg with and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 5 mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces on MS cover and frame including necessary excavation and earth work in any type of soil, returning, filling in approved soil, disposal of surplus soil to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, brick work using bricks as mentioned in PS clause 5.1 in cement mortar 1:6, 15 mm plastering in cement mortar 1:4 both internally and externally 30cm below GL, 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001146 | 1 | Each |
| 28 | 28 | Item No. 14 Supply and Install high efficiency pumping sets, centrifugal pump 3 HP, electric driven, 415V, 50Hz, 3 Ph AC, total head of 24 mtrs range clockwise rotation, stainless steel sleeves for less shaft wear, pipe size of 65x50mm suction/delivery, complete all as specified and directed. | BI01010001010000000000000515BI0100001147 | 2 | Each |
| 29 | 29 | Item No. 15 Rotational moulded polyethylene water storage tank (cylindrical vertical tank with close top) of 5000 Ltr capacity, triple layer with and including 20mm dia brass float valve and GI tank nipple, complete all as specified and directed. | BI01010001010000000000000515BI0100001148 | 2 | Each |
| 30 | 30 | EXTERNAL ELECTRIFICATION, ELECTRIC SIREN & LIGHTENING PROTECTION WORKS , LIFTS WORKS DG SET AND CENTRAL AC WORKS | BI01010001010000000000000515BI0100001149 | ||
| 31 | 31 | Item No. 16 Boring underneath for passing the pipe for 100mm dia pipes complete all as specified. \nNote: (Earth work on both ends of road to facilitate boring shall be meaured and paid for extra relevent item) | BI01010001010000000000000515BI0100001151 | 15 | RM |
| 32 | 32 | Item No.17 Supplying, laying in trenches, jointing, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium conductor 11000 Volts grade earthed, cross sectional area 120 Sqmm 3 core laid in trenches/inducts/along poles or passing through protection pipe wall etc complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earthwork, sand cushioning, cable covers, pipe for cable protection shall be measured and paid for separately. | BI01010001010000000000000515BI0100001152 | 80 | Running Metre |
| 33 | 33 | Item No.18 Supply, jointing, testing and commissioning cable end termination jointing kit 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm, complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001153 | 2 | Each |
| 34 | 34 | Item No.19 Supply and fix cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 ½ core XLPE armoured aluminium conductor cable of 95 sqmm, complete all as specified and directed by Engineer-in-Charge.\nMake : Densel/M Seal/Birla. | BI01010001010000000000000515BI0100001154 | 1 | Each |
| 35 | 35 | Item No.20 Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 185 sqmm, complete all as specified and directed by Engineer-in-Charge.\nMake : Densel/M Seal/Birla. | BI01010001010000000000000515BI0100001155 | 2 | Each |
| 36 | 36 | Item No.21 Supply, installation, testing and commissioning of 125 KVA outdoor transformer pole mounted 11KV on HT side and 433 volts on LT side at no load step down 3 phase 50 c/s AC double wound oil immersed naturally cooled with external cooling tubes core type. Transformer with off load tapping on HT side to vary secondary voltage +- 7.5% in steps of +-2.5 %. The transformer shall confirm with the requirement of IS-2026 and oil shall confirm to IS-335,1983. The temp rise shall not exceed 55 degree centigrade in winding and 45 degree centigrade in oil when measured by the resistance method after continous full load run and on ambient temp of 48 degree centigrade, copper wound, (losses shall be as per IS-1180 Part I 2014 level 3 ), complete all as specified and directed by Engineer-in-Charge. The transformer shall include the following:-\n(a) HV Bushing of suitable size.\n(b) LV glands and cable box of suitable size.\n(c) Oil conservator.\n(d) Dehydrating breather with first fill of dehydrating agent.\n(e) Thermometer pocket with thermometer dial of suitable size.\n(f) Two Earthing terminals on tank and take cover with lugs to suit 32x6 mm GI strip.\n(g) Rating Plate.\n(h) Terminal marking plate.\n(i) Oil level gauge.\n(j) Oil drain and filter valve.\n(k) Lifting lugs\n(l) Four plain rollers.\n(m) Oil filter plug with connection complete.\n(n) Extra bushing for neutral outside the cable box for providing independent earthing.\n(o) Oil filling hole with cap.\n(p) First filling of oil.\n(q) One cable box on LV side with one cable gland suitable for reception of 01 No 3.5 core 400 sqmm LT cable.\n\n | BI01010001010000000000000515BI0100001158 | 1 | Each |
| 37 | 37 | Item No.22 Supplying, laying XLPE insulated galvanized steel strip armoured cable of size 185 Sqmm 3.5 core,1100 volts aluminium conductor heavy duty laid in trenches, fixing along the poles, passing through pipes or laid under floor through protection pipe, walls etc jointing and testing of cross sectional area complete all as specified and directed by Engineer-in-Charge.\nNote : Earthwork, Sand Cushioning, Cable covers, pipe for cable protection shall be measured and paid for separately. | BI01010001010000000000000515BI0100001159 | 320 | Running Metre |
| 38 | 38 | Item No.23 Supplying, laying XLPE insulated galvanized steel strip armoured cable of size 95 Sqmm 3.5 core,1100 volts aluminium conductor heavy duty laid in trenches, fixing along the poles, passing through pipes or laid under floor through protection pipe, walls etc jointing and testing of cross sectional area complete all as specified and directed by Engineer-in-Charge.\nNote : Earthwork, Sand Cushioning, Cable covers, pipe for cable protection shall be measured and paid for separately. | BI01010001010000000000000515BI0100001160 | 200 | Running Metre |
| 39 | 39 | Item No. 24 Supplying, laying XLPE insulated galvanized steel strip armoured cable of size 35 Sqmm 3.5 core,1100 volts aluminium conductor heavy duty laid in trenches, fixing along the poles, passing through pipes or laid under floor through protection pipe, walls etc jointing and testing of cross sectional area complete all as specified and directed by Engineer-in-Charge.\nNote : Earthwork, Sand Cushioning, Cable covers, pipe for cable protection shall be measured and paid for separately. | BI01010001010000000000000515BI0100001161 | 200 | Running Metre |
| 40 | 40 | Item No.25 Supplying, laying XLPE insulated galvanized steel strip armoured cable of size 10Sqmm 2.0 core,1100 volts aluminium conductor heavy duty laid in trenches, fixing along the poles, passing through pipes or laid under floor through protection pipe, walls etc jointing and testing of cross sectional area complete all as specified and directed by Engineer-in-Charge.\nNote : Earthwork, Sand Cushioning, Cable covers, pipe for cable protection shall be measured and paid for separately. | BI01010001010000000000000515BI0100001162 | 200 | Running Metre |
| 41 | 41 | Item No. 26 Supply, installation, commissioning and testing of LT out door cubical compartment type panel box , CPRI approved factory made, made out of 3.15 mm thick CRCA sheet as outlet shell and 2 mm thick CRCA sheet as inner shell, duly painted with two coats of synethic enamelled paint over a coat of red oxide primer, both side openable, front side with double shutter, with side locking arrangement, mounted on MS stand of suitable size made out of MS Angle iron of size 50x50x6 mm,frame fixed in PCC block 1:3:6 of size 450x450x450mm, legs of MS stand shall be 600 mm above ground level and 300 mm below ground, vermin proofs, making necessary cable connection with cable thimble, glands, Aluminium TPN bus bar of capacity 400 Amp minimum size 40x10 mm thick and minimum length not less then 900 mm each duly PVC/epoxy coated, mounted on PVC/epoxy insulator complete=1 Set and all MCCB's connection shall be with aluminum bus strip of suitable rating from main bus bar, MCCB's mounting arrangent shall be adjustable type,of size 25x4mm Al bus strip on lower back side of LT panel for earthing purpose with IP 65 protection complete all as speciefied.\nNote : (i)The drawing and design of FPB /Specifications is to be approved from GE before manufacturing (ii) All internal connection from bus bar to MCCBs will be connected with aluminium strip of suitable size.\n(iii) All MCCBs mounting arrangement will be adjustable towards front faces/depth wise (iv) Quoated cost deem to be included all adjustable arrangement as specified and as directed no extra cost will be admissible for any reason.\n(v) Door shutters butt hinges/strip hinges will be fixed with nut &bolts with locking arrangement. :-\n\n\n\n | BI01010001010000000000000515BI0100001163 | 1 | Each |
| 42 | 42 | Item No. 26(Contd..)\nIncoming :-\n(a) MCCB 4 pole, 250 Amp 415 Volts, 50 Hz breaking capacity not less than 35 KA with adjustable thermal and adjustable magnetic protection release 415 volts 50Hz complete -01 Nos. \n(b) Digital type Volt meter 0-500 Voltssquare type with selector switch - 01 No.\n(c) Digital type Ammeter 0-600 Amps square type with selector switch - 01 No.\n(d) Wiring complete with copper wire of suitable size \n(e) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.\n(f) CT's 250/5A-3 Nos\n(g) Cable glands brass of suitable size for cable. Outgoing :- \n(a) MCCB 125 Amps with adjustable and thermomagnetic release 4 Pole. having breaking capacity 25 KA with adjustable thermal and adjustable magnetic protection release 415 volts 50Hz complete -02Nos. \n(b) MCCB 63 Amps with adjustable and thermomagnetic release 4 Pole. having breaking capacity 16KA with adjustable thermal and adjustable magnetic protection release 415 volts 50Hz complete -02Nos. \n(c) MCB 16 Amps single Pole netural. 415 Volts having breaking capacity 10 KA -04Nos. | BI01010001010000000000000515BI0100001164 | ||
| 43 | 43 | Item No. 27 Supply, installation, commissioning and testing of LT out door cubical compartment type panel box , CPRI approved factory made, made out of 3.15 mm thick CRCA sheet as outer shell and 2 mm thick CRCA sheet as inner shell, duly painted with two coats of synethic enamelled paint over a coat of red oxide primer, both side openable, front side with double shutter, with side locking arrangement, mounted on MS stand of suitable size made out of MS Angle iron of size 50x50x6 mm,frame fixed in PCC block 1:3:6 of size 450x450x450mm, legs of MS stand shall be 600 mm above ground level and 300 mm below ground, vermin proofs, making necessary cable connection with cable thimble, glands, Aluminium TPN bus bar of capacity 400 Amp minimum size 40x10 mm thick and minimum length not less then 900 mm each duly PVC/epoxy coated, mounted on PVC/epoxy insulator complete=1 Set and all MCCB's connection shall be with aluminum bus strip of suitable rating from main bus bar, MCCB's mounting arrangent shall be adjustable type,of size 25x4mm Al bus strip on lower back side of LT panel for earthing purpose with IP 65 protection complete all as speciefied.\nNote : (i)The drawing and design of FPB /Specifications is to be approved from GE before manufacturing (ii) All internal connection from bus bar to MCCBs will be connected with aluminium strip of suitable size.\n(iii) All MCCBs mounting arrangement will be adjustable towards front faces/depth wise (iv) Quoated cost deem to be included all adjustable arrangement as specified and as directed no extra cost will be admissible for any reason.\n(v) Door shutters butt hinges/strip hinges will be fixed with nut &bolts with locking arrangement. :-\n\n\n\n | BI01010001010000000000000515BI0100001165 | 1 | Each |
| 44 | 44 | Item No.27(Contd..) \nIncoming :-\n(a) MCCB 4 pole, 125 Amp 415 Volts, 50 Hz breaking capacity not less than 25 KA with adjustable thermal and adjustable magnetic protection release 415 volts 50Hz complete -01 Nos. \n(b) Digital type Volt meter 0-500 Volts square type with selector switch - 01 No.\n(c) Digital type Ammeter 0-600 Amps square type with selector switch - 01 No.\n(d) Wiring complete with copper wire of suitable size \n(e) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.\n(f) CT's 250/5A-3 Nos\n(g) Cable glands brass of suitable size for cable.\nOutgoing :- \n(a) MCCB 63 Amps with adjustable and thermomagnetic release 4 Pole. having breaking capacity 16KA with adjustable thermal and adjustable magnetic protection release 415 volts 50Hz complete -04No\n(b) MCB 16 Amps single Pole netural. 415 Volts having breaking capacity 10 KA -04Nos. | BI01010001010000000000000515BI0100001166 | ||
| 45 | 45 | Item No.28 Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron 32x6mm earth strip by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, light grade 40mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. all as specified. \nNote : 1. Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner. \n2. Cost of 7.5m length of GI strip & GI protection pipe included in the rate of this item. Extra length shall be measured and paid separately | BI01010001010000000000000515BI0100001167 | 18 | Each |
| 46 | 46 | Item No. 29 Earthing complete with galvanised steel earth plate electrode 600x600x6 mm, burried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate vertically to a depth not less than 1.5m below ground level, connected to galvanised steel earth lead wire 4.00 mm dia (8 SWG) of any length as required at site, by means of bolts, nuts, check nuts and washers of galvanised steel, earth lead wire encased in and including 15 mm bore GI medium grade pipe for protection of GI wires 20 mm dia watering pipe medium grade including charcoal dust and common salt packed all around the earth plate, including necessary excavation and earth work in any type of soil /strata all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. all as specified. \nNote : (i) Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner. (ii) Cost of 7.5m length of GI wire & GI protection pipe included in the rate of this item. Extra length shall be measured and paid separately. | BI01010001010000000000000515BI0100001168 | 3 | Each |
| 47 | 47 | Item No. 30 Supply & fixing solar street light 43W LED luminaires outdoor separate solar panel having maintenance free Lithium ion battery, having intellignet charging system which provides back up even on cloudy days automatic ON/OFF inbuilt sensor based on abbient light conditions, IEC certified LED pressure die cast aluminium body for thermal management an IP-65 compliant design Both LED 30W Light and 50W solar panel mounted on 80mm dia powder coated MS pipe 6 mtr long medium grade complete with suitable bracket prewired complete all as specified and as directed by Engr-in-Charge.BHEL/BPL/HAVELL/CG | BI01010001010000000000000515BI0100001169 | 4 | Each |
| 48 | 48 | Item No.31 Supply and errection of steel tubular swaged poles single swan neck, 09 mtr long, type -410 SP-31 confirming to IS 2713 applying 2 coats of aluminium paint over a coat of red oxide primer externally above ground level and a coat of anti-corrosive paint below ground level and marking with alternate yellow and black paint strip 30 cm wide-total 05 Nos with synthetic enemal paint complete with and including provision of CI base plate, final taper plug bolts, nuts, screws, drilling works including numbering to poles, erected & fixed in vertical position complete all as specified and directed by Engineer-in-Charge.\nNote :- Excavation, PCC in foundation/plinth block/ coping cross arms, bracings, clamps etc shall be measured and paid separately. | BI01010001010000000000000515BI0100001170 | 6 | Each |
| 49 | 49 | Item No. 32 Supply and errection of steel tubular swaged poles 11 mtr long, type -410 SP-55 confirming to IS 2713 applying 2 coats of aluminium paint over a coat of red oxide primer externally above ground level and a coat of anti-corrosive paint below ground level and marking with alternate yellow and black paint strip 30 cm wide-total 05 Nos with synthetic enemal paint complete with and including provision of MS base plate, final taper plug bolts, nuts, screws, drilling works including numbering to poles, erected & fixed in vertical position complete all as specified and directed by Engineer-in-Charge.\nNote :- Excavation, PCC in foundation/plinth block/ coping cross arms, bracings, clamps etc shall be measured and paid seperately. | BI01010001010000000000000515BI0100001171 | 4 | Each |
| 50 | 50 | Item No.33 Aesthetically Designed SMD LED Street light luminaires of 45 watts System wattage for energy saving having IP-66 degree of protection ,With minimum system efficiency as > 85 % ,made of Pressure die cast aluminum housing powder coated in graphite grey and heat resistant thoughned glass with excellent thermal management including PVC cable connector. LED's should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120 - 270 VAC , THD <10% , P.F >.95 .The fitting should have in built surge protector of 5 KV, including necessary bracket made out of GI pipe with clamp, nuts and bolts for mounting of complete all as specified. | BI01010001010000000000000515BI0100001172 | 6 | Each |
| 51 | 51 | Item No. 34 Supply, installation, commissioning and testing of LT in door cubical compartment type panel box , CPRI approved factory made, made out of 2 mm thick CRCA sheet as inner sheet house in outer shall made out of 2 mm thick CRCA sheet, duly painted with two coats of synethic enamelled paint over a coat of red oxide primer, both side openable, front side with double shutter, with side locking arrangement, mounted on MS stand of suitable size made out of MS Angle iron of size 50x50x6 mm,frame fixed in PCC block 1:3:6 of size 450x450x450mm, legs of MS stand shall be 600 mm above ground level and 300 mm below ground, vermin proofs, making necessary cable connection with cable thimble, glands, Aluminium TPN bus bar of capacity 400 Amp minimum size 40x10 mm thick and minimum length not less then 900 mm each duly PVC/epoxy coated, mounted on PVC/epoxy insulator complete=1 Set and all MCCB's connection shall be with aluminum bus strip of suitable rating from main bus bar, MCCB's mounting arrangent shall be adjustable type,of size 25x4mm Al bus strip on lower back side of LT panel for earthing purpose with IP 65 protection complete all as speciefied.\nNote : (i)The drawing and design of FPB /Specifications is to be approved from GE before manufacturing (ii) All internal connection from bus bar to MCCBs will be connected with aluminium strip of suitable size.\n(iii) All MCCBs mounting arrangement will be adjustable towards front faces/depth wise (iv) Quoated cost deem to be included all adjustable arrangement as specified and as directed no extra cost will be admissible for any reason.\n(v) Door shutters butt hinges/strip hinges will be fixed with nut &bolts with locking arrangement. :-\n\n\n\n | BI01010001010000000000000515BI0100001173 | 1 | Each |
| 52 | 52 | Item No. 34 (Contd..)\nIncoming :-\n(a) MCCB 4 pole, 63 Amp 415 Volts, 50 Hz breaking capacity not less than 25 KA with adjustable thermal and adjustable magnetic protection release 415 volts 50Hz complete -01 Nos. \n(d) Digital type Volt meter 0-500 Voltssquare type with selector switch - 01 No.\n(e) Digital type Ammeter 0-600 Amps square type with selector switch - 01 No.\n(f) Wiring complete with copper wire of suitable size \n(g) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.\n(h) CT's 250/5A-3 Nos\n(i) Cable glands brass of suitable size for cable. \nOut going :- \n(a) MCB TPN 16 Amps 415 volts 50Hz with repturing capacity 10 KA complete -02Nos. \n(b) Star direct online starter ,IS 13947-4, On/Off switch with colour code ,current rating 12 Amp, suitable upto 3 HP of overloar relay 4-6 Amp complete-02 Nos \n | BI01010001010000000000000515BI0100001174 | ||
| 53 | 53 | INTERNAL WATER SUPPLY WORKS | BI01010001010000000000000515BI0100001175 | ||
| 54 | 54 | INTERNAL ELECTRIFICATION AND CONDUIT FOR TV/TELEPHONE/INTERCOM/LAN WORKS | BI01010001010000000000000515BI0100001176 | ||
| 55 | 55 | Item No.35 Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, ZHFR/HFFR, PVC insulated and unsheathed stranded cable 1100 volts grade, ISI-694 marked TEC and FIA approved in and including heavy duty, PVC concealed conduit, ISI marked, with and inluding mild steel sunken fabricated with 1.60mm MS sheet concealed in walls boxes suitable for switches / sockets etc with earth dolly duly painted with two coats of anti corrosive paint over a coat of red oxide primer internally, and covered with and including suitable plastic laminated sheet top cover 3mm thick fixed with cadmium plated iron screws for housing the switches, switch sockets outets, fan regulators etc including ZHFR/HFFR PVC insulated,unsheathed stranded copper conductor 1.5 Sq. mm nominal cross sectional area wire as earth continuity conductor upto common earth and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge for the following:- | BI01010001010000000000000515BI0100001177 | ||
| 56 | 56 | (a) One Light/Fan/Bell point controlled by one switch 5Amp (light/fan/exhaust) and regulator | BI01010001010000000000000515BI0100001178 | 423 | Per Point |
| 57 | 57 | (b) Socket outlet, three pin, 5 Amp, on the independent board. | BI01010001010000000000000515BI0100001179 | 106 | Per Point |
| 58 | 58 | (c). Socket outlet, three pin, 5 Amp, on the same board wth other switches. | BI01010001010000000000000515BI0100001180 | 45 | Per Point |
| 59 | 59 | (d) One light point controlled by two, 2 way switches. | BI01010001010000000000000515BI0100001181 | 5 | Per Point |
| 60 | 60 | (e) 2.5 Sq mm cable for 5 Pin , 5/15 Amp. | BI01010001010000000000000515BI0100001182 | 18 | Per Point |
| 61 | 61 | Item No.36 Socket Outlet RJ-11 piano flush type ISI marked with valid CML No. complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001184 | 25 | Each |
| 62 | 62 | Item No.37 TV Socket outlet piano flush type ISI marked with valid CML No. complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001185 | 25 | Each |
| 63 | 63 | Item No.38 Sub-main wiring with 2 single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 4 Sq mm drawing in & including heavy grade FRLS PVC Concealed conduit ISI marked of suitable size with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional 1 run of wire of 4 Sq mm but green in colour for earth DBs and boxes with proper thimbles, complete all as specified and directed by Engineer-in-Charge. Note for payment pupose: 3 run of 4 sqmm submain wiring and PVC Conduit measured as one running meter | BI01010001010000000000000515BI0100001186 | 300 | Running Metre |
| 64 | 64 | Item No.39 Sub-main wiring with 2 single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 6 Sq mm drawing in & including heavy grade FRLS PVC Concealed conduit ISI marked of suitable size ith all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional 1 run of wire of 6 Sq mm but green in colour for earth DBs and boxes with proper thimbles, complete all as specified and directed by Engineer-in-Charge. \nNote for payment pupose: 3 run of 6 sqmm submain wiring and PVC Conduit measured as one running meter | BI01010001010000000000000515BI0100001187 | 150 | Running Metre |
| 65 | 65 | Item No.40 Sub-main wiring with 2 single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 10 Sqmm drawing in & including heavy grade FRLS PVC Concealed conduit ISI marked of suitable size ith all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional 1 run of wire of 10 Sq mm but green in colour for earth DBs and boxes with proper thimbles complete all as specified and directed by Engineer-in-Charge. Note for payment pupose: 3 run of 10 sqmm submain wiring and PVC Conduit measured as one running meter, complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001188 | 50 | Running Metre |
| 66 | 66 | Item No.41 MCB SP, 230volt , 50 Hzs, 40 A, 10 KA , \"C\" series complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001189 | 1 | Each |
| 67 | 67 | Item No.42 MCB SP, 230volt , 50 Hzs, 6 to 32 A, 10 KA , \"C\" series complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001190 | 60 | Each |
| 68 | 68 | Item No.43 MCB SPN 'C' Curve as incommer, 220 volt , 50 Hzs, 20 Amps, 10 KA complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001191 | 3 | Each |
| 69 | 69 | Item No.44 MCB SPN 'C' Curve as incommer, 220 volt , 50 Hzs, 32 Amps, 10 KA complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001192 | 9 | Each |
| 70 | 70 | Item No.45 MCB SPN 'C' Curve as incommer, 220 volt , 50 Hzs, 40 Amps, 10 KA complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001193 | 6 | Each |
| 71 | 71 | Item No.46 MCB SPN 'C' Curve as incommer, 220 volt , 50 Hzs, 50 Amps, 10 KA complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001194 | 3 | Each |
| 72 | 72 | Item No.47 Ceiling fan complete with accessories 230 V,1200 mm sweep. BEE 5 star rated and equivalent latest EER/ISEER rating including connecting with 1.5Sqmm 3 core flexible wire complete all as specified and directed by Engineer-in-Charge. \nMake: Havells ES-505 or equivalent make as mentioned in Appendix 'B', complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001195 | 80 | Each |
| 73 | 73 | Item No.48 Exhaust fans AC single phase 230/ 240 V of size 380 mm sweep 900 RPM with louver including connecting with 1.5Sqmm 3 core flexible wire complete all as specified and directed by Engineer-in-Charge.\nMake: Havells Turbo Force SP or equivalent makes as mentioned in Appendix 'B', complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001196 | 16 | Each |
| 74 | 74 | Item No.49 Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001197 | 80 | Each |
| 75 | 75 | Item No.50 LED bulb 7 watt, 230 volt AC, 50 Hz, Retrofit, B22 base for lamp holder complete all as specified and directed by Engineer-in-Charge. \nMake: Havells Lumeno LED Lamps Cat Part No. LHLDAGUEML8X007 or equivalent makes as mentioned in Appendix 'B', complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001198 | 99 | Each |
| 76 | 76 | Item No.51 LED Surface Mounted Square Downlighter (1’x1’) (Porch Light) made of die cast aluminium housing with high efficiency diffuser, 80 lumen/W system efficacy, complete all as specified and directed by Engineer-in-Charge. \nMake: Phillips Cat Part No SM200C LED16S 6500 PSU OD WH or equivalent makes as mentioned in Appendix 'B', | BI01010001010000000000000515BI0100001199 | 2 | Each |
| 77 | 77 | Item No.52 Socket outlet RJ 45 piano flush type ISI marked with valid CML No. complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001208 | 25 | Each |
| 78 | 78 | Item No.53 Exhaust fans AC single phase 230/ 240 V of size 450 mm sweep 900 RPM with louver complete all as specified and directed by Engineer-in-Charge. \nMake: Havells Turbo Force SP or equivalent makes as mentioned in Appendix 'B'. | BI01010001010000000000000515BI0100001217 | 2 | Each |
| 79 | 79 | Item No.54 Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep 900 RPM with louver complete all as specified and directed by Engineer-in-Charge. \nMake: Havells Turbo Force SP or equivalent makes as mentioned in Appendix 'B'. | BI01010001010000000000000515BI0100001226 | 2 | Each |
| 80 | 80 | Item No.55 MCCB TPN 160 A,with thermal magnetic protection having Ics=ICS 100%, 25 KA, thermal adjustable .8 to 1 in inclusive 08 Nos spreader link as per OEM of MCCB all as per legrand Make Cat No 420047 or equivalent in ABB/Schneider, complete all as specified and directed by Engineer-in-Charge.\nNote: The make of MCCB must be as per that of TPN DB as described in the respective schedule of this CA. | BI01010001010000000000000515BI0100001235 | 1 | Each |
| 81 | 81 | Item No.56 LED luminaries surface mounted prewired 20 watt with high efficiency elegent driver batten indoor complete all as specified.\nMake: Halonix Cat Part No HLB-03-20-CW-AL or equivalent makes as mentioned in Appendix 'B'. | BI01010001010000000000000515BI0100001244 | 235 | Each |
| 82 | 82 | Item No.57 LED luminaries surface mounted prewired 10 watt with high efficiency elegent driver batten indoor complete all as specified.\nMake: Halonix Cat Part No HLB-03-10-CW-AL or equivalent makes as mentioned in Appendix 'B'. | BI01010001010000000000000515BI0100001253 | 70 | Each |
| 83 | 83 | Item No.58 Aesthetically Designed SMD LED Street light luminaires of 45 watts System wattage for energy saving having IP-66 degree of protection, with minimum system efficiency as > 85 % ,made of Pressure die cast aluminum housing powder coated in graphite grey and heat resistant toughened glass with excellent thermal management including PVC cable connector. LEDs should have lens optics and vandal proof prismatic poly carbonate covers for ensurring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120-270 VAC, THD<10%, PF> 95. The fitting should have in built surge protector of 5 KV, including necessary bracket made out of GI pipe with clamp, nuts and bolts for mouting of complete all as specified.\nMake: Crompton Cat Part No LSTP-45-CDL or equivalent makes as mentioned in Appendix 'B'. | BI01010001010000000000000515BI0100001262 | 13 | Each |
| 84 | 84 | Item No.59 Junction box with 6Amps,MCB 'C' curve,IP 66/67 all as per IEC 60529. The Junction box shall be insulated and made out of polycarbonate with glass fiber reinfored.The polycarbonate JB shall be not less then 205x225x112mm suitable for 16/25sqmm cables size with terminals,environment fiendly,recyclable,UV resistant,halogen and silicon free,anti acid and anti corrosive.The gasket material shall be polyurethane and the gasket shall be internally embedded.The JBs shall be complies with requirements shall be internally embedded. The JBs shall be complies with requirements if the standards IEC 60998-1,IEC-60998-2-1,IEC-60670-22.For better safety the polycarbonate encl shall be fire retardant and self-extinguishing in accordance with IEC 60695-2-11.\nMake:- Hensel/Schneider/Rittal | BI01010001010000000000000515BI0100001271 | 6 | Each |
| 85 | 85 | Note:-For the purpose of arriving at lumpsum amount,the amount of credit schedule,Sch'A' Section XI (i.e Rs 36955.00) shall be deducted from the total amount arrived. | BI01010001010000000000000515BI0100001280 |
AI Tender Summary
Tender Timeline
Nov 08, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedDec 14, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 17, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender