Repair Of Upswc Godowns At Sitapur
Tender Value
31.79 Lakhs
Estimated cost
Bid Submission
23 Nov 2019
0 days left
EMD
63600
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sitapur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair Of Upswc Godowns At Sitapur
BOQ
| Name of Work:Repair of Boundrywall,Godown, Office & Construction of Toilets etc at Sitapur | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Boundrywall Work | BI01010001010000000000000515BI0100001112 | ||
| 2 | 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. | BI01010001010000000000000515BI0100001113 | 39.34 | cum |
| 3 | 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | BI01010001010000000000000515BI0100001114 | 1.89 | cum |
| 4 | 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001115 | 6.98 | cum |
| 5 | 5 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) | BI01010001010000000000000515BI0100001116 | 28.49 | sqm |
| 6 | 6 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. | BI01010001010000000000000515BI0100001117 | 11.34 | sqm |
| 7 | 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001118 | 43.39 | cum |
| 8 | 8 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar | BI01010001010000000000000515BI0100001119 | 25.14 | cum |
| 9 | 9 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured):From brick work in cement mortar | BI01010001010000000000000515BI0100001120 | 10.52 | 1000 Nos |
| 10 | 10 | 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) | BI01010001010000000000000515BI0100001121 | 61.32 | sqm |
| 11 | 11 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001122 | 196.9 | sqm |
| 12 | 12 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) | BI01010001010000000000000515BI0100001123 | 258.22 | sqm |
| 13 | 13 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | BI01010001010000000000000515BI0100001124 | 33.67 | cum |
| 14 | 14 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | BI01010001010000000000000515BI0100001125 | 1461.4 | sqm |
| 15 | 15 | Godown Work | BI01010001010000000000000515BI0100001126 | ||
| 16 | 16 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. | BI01010001010000000000000515BI0100001127 | 194.4 | kg |
| 17 | 17 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes | BI01010001010000000000000515BI0100001128 | 2268 | kg |
| 18 | 18 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. | BI01010001010000000000000515BI0100001129 | 458.82 | sqm |
| 19 | 19 | Extra for providing and fixing wind ties of 40x 6 mm flat iron section | BI01010001010000000000000515BI0100001130 | 248.4 | metre |
| 20 | 20 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase | BI01010001010000000000000515BI0100001131 | 173.15 | metre |
| 21 | 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001132 | 99.96 | sqm |
| 22 | 22 | Fixing of bolt by drilling & as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001133 | 216 | No. |
| 23 | 23 | Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. | BI01010001010000000000000515BI0100001134 | 197.4 | kg |
| 24 | 24 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:Asbestos cement sheet | BI01010001010000000000000515BI0100001135 | 163 | sqm |
| 25 | 25 | Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete.Close fitting adjustable ridges | BI01010001010000000000000515BI0100001136 | 10 | metre |
| 26 | 26 | Refixing of old wind tie & as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001137 | 105 | metre |
| 27 | 27 | S/L Tarfelt I.S.I. Mark Krishna or Bengal felt weight per roll 42 kg.under layer of bitumen compound 85/25 approved Quality & as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001138 | 103 | Sqm |
| 28 | 28 | Repair of rolling shutter i/e washing of Shutter by kerosin oil, oiling gressing and tighting of spring, T & P etc Complete & as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001139 | 10 | Nos |
| 29 | 29 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | BI01010001010000000000000515BI0100001140 | 1026.99 | sqm |
| 30 | 30 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001141 | 1026.99 | sqm |
| 31 | 31 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete | BI01010001010000000000000515BI0100001142 | 6144.65 | sqm |
| 32 | 32 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface | BI01010001010000000000000515BI0100001143 | 6433.48 | sqm |
| 33 | 33 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. | BI01010001010000000000000515BI0100001144 | 1026.99 | sqm |
| 34 | 34 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work | BI01010001010000000000000515BI0100001145 | 1469.33 | sqm |
| 35 | 35 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001146 | 4.9 | cum |
| 36 | 36 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001147 | 1.03 | cum |
| 37 | 37 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate | BI01010001010000000000000515BI0100001148 | 51.06 | sqm |
| 38 | 38 | Office Work | BI01010001010000000000000515BI0100001149 | ||
| 39 | 39 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | BI01010001010000000000000515BI0100001150 | 154.77 | sqm |
| 40 | 40 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001151 | 163.51 | sqm |
| 41 | 41 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete | BI01010001010000000000000515BI0100001152 | 195.77 | sqm |
| 42 | 42 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats) | BI01010001010000000000000515BI0100001153 | 208.81 | sqm |
| 43 | 43 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer | BI01010001010000000000000515BI0100001154 | 84.68 | sqm |
| 44 | 44 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. | BI01010001010000000000000515BI0100001155 | 78.83 | sqm |
| 45 | 45 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface | BI01010001010000000000000515BI0100001156 | 86.63 | sqm |
| 46 | 46 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work | BI01010001010000000000000515BI0100001157 | 39.72 | sqm |
| 47 | 47 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) | BI01010001010000000000000515BI0100001158 | 2.16 | sqm |
| 48 | 48 | Supply /Boring 0.75 HP Submersible pump & as per direction of Engineer-in-charge.150' deep. | BI01010001010000000000000515BI0100001159 | 1 | No. |
| 49 | 49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001160 | 20 | metre |
| 50 | 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001161 | 15 | metre |
| 51 | 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 15 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001162 | 10 | metre |
| 52 | 52 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore | BI01010001010000000000000515BI0100001163 | 2 | each |
| 53 | 53 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore | BI01010001010000000000000515BI0100001164 | 1 | each |
| 54 | 54 | Cleanning of old septic tank & as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001165 | 1 | No. |
| 55 | 55 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001166 | 0.23 | cum |
| 56 | 56 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars | BI01010001010000000000000515BI0100001167 | 14.88 | Kg |
| 57 | 57 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | BI01010001010000000000000515BI0100001168 | 70.09 | sqm |
| 58 | 58 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. | BI01010001010000000000000515BI0100001169 | 306.29 | cum |
| 59 | 59 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. | BI01010001010000000000000515BI0100001170 | 200 | per litre |
| 60 | 60 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore | BI01010001010000000000000515BI0100001171 | 3 | each |
| 61 | 61 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001172 | 3.13 | cum |
| 62 | 62 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter | BI01010001010000000000000515BI0100001173 | 6 | metre |
| 63 | 63 | Construction of Toilets | BI01010001010000000000000515BI0100001174 | ||
| 64 | 64 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | BI01010001010000000000000515BI0100001175 | 1.6 | cum |
| 65 | 65 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. | BI01010001010000000000000515BI0100001176 | 9.15 | cum |
| 66 | 66 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | BI01010001010000000000000515BI0100001177 | 1.59 | cum |
| 67 | 67 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001178 | 8.19 | cum |
| 68 | 68 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001179 | 1.54 | cum |
| 69 | 69 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001180 | 0.22 | cum |
| 70 | 70 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers | BI01010001010000000000000515BI0100001181 | 4.92 | sqm |
| 71 | 71 | Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001182 | 11.49 | sqm |
| 72 | 72 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars | BI01010001010000000000000515BI0100001183 | 142.9 | Kg |
| 73 | 73 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001184 | 6.02 | cum |
| 74 | 74 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | BI01010001010000000000000515BI0100001185 | 4.57 | cum |
| 75 | 75 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001186 | 32.08 | kg |
| 76 | 76 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | BI01010001010000000000000515BI0100001187 | 30 | kg |
| 77 | 77 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws | BI01010001010000000000000515BI0100001188 | 3 | sqm |
| 78 | 78 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. | BI01010001010000000000000515BI0100001189 | 4.1 | sqm |
| 79 | 79 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | BI01010001010000000000000515BI0100001190 | 20.14 | sqm |
| 80 | 80 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001191 | 53.94 | sqm |
| 81 | 81 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats) | BI01010001010000000000000515BI0100001192 | 20.82 | sqm |
| 82 | 82 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. | BI01010001010000000000000515BI0100001193 | 44.61 | sqm |
| 83 | 83 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001194 | 6.27 | sqm |
| 84 | 84 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate | BI01010001010000000000000515BI0100001195 | 9.92 | sqm |
| 85 | 85 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameter | BI01010001010000000000000515BI0100001196 | 6 | metre |
| 86 | 86 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter | BI01010001010000000000000515BI0100001197 | 15 | metre |
| 87 | 87 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | BI01010001010000000000000515BI0100001198 | 1 | each |
| 88 | 88 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern | BI01010001010000000000000515BI0100001199 | 2 | each |
| 89 | 89 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore | BI01010001010000000000000515BI0100001200 | 4 | each |
| 90 | 90 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | BI01010001010000000000000515BI0100001201 | 1 | each |
| 91 | 91 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. | BI01010001010000000000000515BI0100001202 | 700 | per litre |
| 92 | 92 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | BI01010001010000000000000515BI0100001203 | 5.76 | sqm |
| 93 | 93 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. | BI01010001010000000000000515BI0100001204 | 1.6 | cum |
| 94 | 94 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | BI01010001010000000000000515BI0100001205 | 1 | Each |
| 95 | 95 | 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) | BI01010001010000000000000515BI0100001206 | 17.11 | sqm |
AI Tender Summary
Tender Timeline
Nov 07, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 25, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender