Repair Replacement Maintenance To Internal Elect Fittings Fixtures Fan Geyser Including Replacement Of Conventional Fittings Into Eel Fittings Of Certain Md Accn Of Jcos Or At Tb I Depot Bn And Md Single Accn Of Offrs At Beg Centre Under Age Em I C Kirkee
Tender Overview
Project Description
Repair Replacement Maintenance To Internal Elect Fittings Fixtures Fan Geyser Including Replacement Of Conventional Fittings Into Eel Fittings Of Certain Md Accn Of Jcos Or At Tb I Depot Bn And Md Single Accn Of Offrs At Beg Centre Under Age Em I C Kirkee
BOQ
| Name of Work : REPAIR, REPLACEMENT & MAINT TO INTERNAL ELECTRICAL FITTINGS AND FIXTURES, FAN AND GEYSER INCLUDING REPLACEMENT OF CONVENTIONAL FITTINGS INTO EEL FITTINGS OF CERTAIN MD ACCN OF JCOs / OR AT TB-I, DEPOT BN AND MD/SINGLE ACCN OF OFFRs AT BEG & CENTRE UNDER AGE E/M-I (C) KIRKEE. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed. | 760 | Point | |
| 2 | 2 | M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed. | 300 | Point | |
| 3 | 3 | M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed. | 430 | Point | |
| 4 | 4 | M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one two way light point controlled by two, two way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed. | 50 | Point | |
| 5 | 5 | M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 16amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket all as specified and directed. | 165 | Point | |
| 6 | 6 | M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. | 120 | RM | |
| 7 | 7 | M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. | 180 | RM | |
| 8 | 8 | M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. | 80 | RM | |
| 9 | 9 | M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. \nNOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. | 430 | RM | |
| 10 | 10 | M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable of size 10.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. \nNOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. | 20 | RM | |
| 11 | 11 | S&F 5 Amp switch piano type single pole one way incl dismentling taking down unsv one all as specified and as directed | 1830 | Each | |
| 12 | 12 | S&F 5 Amp switch piano type single pole two way incl dismentling taking down unsv one all as specified and as directed | 70 | Each | |
| 13 | 13 | S&F bell push piano type one way 240 volt incl dismentling taking down unsv one . all as specified and as directed | 70 | Each | |
| 14 | 14 | S&F socket flush type 6 amps, 5 pin, 230v incl dismentling taking down unsv one all as specified and as directed | 960 | Each | |
| 15 | 15 | S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed | 260 | Each | |
| 16 | 16 | S&F lamp Holder insulated body with back plate for batten fitting incl dismentling taking down unsv one all as specified and as directed | 310 | Each | |
| 17 | 17 | S&F LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips | 670 | Each | |
| 18 | 18 | S&F LED lamp 12 watt, CDL, E-27 cap, (Thread type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips | 10 | Each | |
| 19 | 19 | S&F LED lamp 3 watt, CDL, E-14 cap, (Small thread type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips | 15 | Each | |
| 20 | 20 | S&F ceiling rose surface Bakelite three terminal incl dismentling taking down unsv one all as specified and as directed. | 760 | Each | |
| 21 | 21 | S&F call bell electric, ding dong, AC 240 volt, 50 HZ. incl dismentling taking down unsv one all as specified and as directed. | 70 | Each | |
| 22 | 22 | S&F flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz incl dismentling taking down unsv one all as specified and as directed. | 310 | Each | |
| 23 | 23 | S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4085-87 to 4085-95 of Legrand or equivalent of Schneider/ABB. | 250 | Each | |
| 24 | 24 | S&F MCB, Double Pole, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4086-28 to 4086-36 of Legrand or equivalent of Schneider/ABB\n | 80 | Each | |
| 25 | 25 | S&F MCB, Four Pole, 40 to 63 amps, 415 Volts incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4087-00 to 4087-02 of Legrand or equivalent of Schneider/ABB\n | 22 | Each | |
| 26 | 26 | S&F Sheet metal enclosure two way, incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No-5077 91 to -5077 93 of Legrand or equivalent of Schneider/ABB. | 28 | Each | |
| 27 | 27 | S&F MCB distribution board,Double door, metal enclosure, SPN, 230 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 10 of Legrand or equivalent of Schneider/ABB | 20 | Each | |
| 28 | 28 | S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 11 of Legrand or equivalent of Schneider/ABB | 26 | Each | |
| 29 | 29 | S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts,12 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 12 of Legrand or equivalent of Schneider/ABB | 16 | Each | |
| 30 | 30 | S&F MCB distribution board, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076-70 of Legrand or equivalent of Schneider/ABB | 8 | Each | |
| 31 | 31 | S&F Vertical MCB distribution board, as MCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5077-25 of Legrand or equivalent of Schneider/ABB | 3 | Each | |
| 32 | 32 | S&F Vertical MCB distribution board, as MCCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No-507745 of Legrand or equivalent of Schneider/ABB | 2 | Each | |
| 33 | 33 | S&F Metal plug and socket board with MCB SP 20 amp, 16 KA incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5078 11 of Legrand or equivalent of Schneider/ABB | 25 | Each | |
| 34 | 34 | S&F PVC rectangular switch board of size 300mmx 250mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza. | 30 | Each | |
| 35 | 35 | S&F PVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza. | 55 | Each | |
| 36 | 36 | S&F PVC rectangular switch board of size 175mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza. | 60 | Each | |
| 37 | 37 | S&F PVC rectangular switch board of size 100mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza. | 60 | Each | |
| 38 | 38 | S&F Hylam Sheet 3mm thick on existing concealled MS/CI ractangular or Squar or round box with 04 nos cadmium coated screws and cup washer incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc incl dismentling taking down unsv one | 7 | Sqm | |
| 39 | 39 | S&F Round shaped recess mounted LED Flat panel down lighter, 12 watt (8\"dia), suitable for POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed. Make-Havells , Cat Part No LHEAABP7L1W012or equivalent in Bajaj/Philips/HPL/Havells | 4 | Each | |
| 40 | 40 | S&F Square shaped recess mounted LED slim Flat panel suitable for fixing in aluminium framed ceilling, 36 watt, 2'x2'size, complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed. Make-CG, Cat Part No LCPL-36-CDL (2x2) (Aura) or equivalent in Bajaj/Philips/HPL/Havells | 3 | Each | |
| 41 | 41 | S&F LED tube 20 watt retrofit to existing fluorescent FTL (T-8) fitting surface mounted after dismentling electronic ballast, internal wiring and complete rewiring with 0.5 sqmm copper flexible conductor FRLSHom connector block to one end of Bipi holder and including connecting up to ceiling rose with 0.5 sqmm two core flexible copper conductor cable all as specified and directed. Make-Cat Part No HLPLEDT8PCP20CW HPL or equivalemt in Bajaj/Philips/Crompton Greaves /Havells | 820 | Each | |
| 42 | 42 | S&F industrial box type LED Batten with CRCA body, pre coated with white and prewired suitable for LED tube 1x18/20 watt 4'long incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL, Cat Part No-HLPLEDT801WT or equivelent of Bajaj/Philips/CG/Havells | 640 | Each | |
| 43 | 43 | S&F LED batten tube light, 2'long, 09 watt,CDL 230 Volts ,complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL Cat Part No- HLPT51509PCGCW or equivalemt in Bajaj/Philips/CG/Havells | 40 | Each | |
| 44 | 44 | S&F LED batten tube light, 20 watt, CDL, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL, Cat Part No HPLLEDT5PC20W or equivalemt in Bajaj/Philips/CG/Havells | 370 | Each | |
| 45 | 45 | S&F LED building security light 15 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed. Make-CG, Cat Part No LSTP-15-CDL or equivalent in Bajaj/Philips/HPL/Havells | 30 | Each | |
| 46 | 46 | REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK :-\nM&L for Rewinding of Ceiling fan 1400 mm sweep after dismenting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete. \nNote: 1. Contractor will collect fans from the complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate. 2. Spares require for replacement such as bearing, Bushing, capacitor shall be measured and paid separately as supply & fixing only. 3. Cost of Connector block and capacitor holder shall be inclusive of the quoted rate. | 18 | Each | |
| 47 | 47 | All as per item No- 46 here-in-above but for Ceiling fan 1200 mm sweep | 580 | Each | |
| 48 | 48 | All as per item No- 46 here-in-above but for Exhaust fan 450 mm sweep industrial type. | 2 | Each | |
| 49 | 49 | All as per item No- 46 here-in-above but for Exhaust fan 300 mm sweep industrial type. | 40 | Each | |
| 50 | 50 | All as per item No- 46 here-in-above but for Exhaust fan 300/250 mm sweep domestic type. | 140 | Each | |
| 51 | 51 | S&F ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC. | 840 | Each | |
| 52 | 52 | S&F G.M. Bush bearing for ceiling fan as per existing pattern. | 170 | Each | |
| 53 | 53 | S&F capacitor AC for 230 volts 50 Hz of capacity 1.8 Mfd. | 10 | Each | |
| 54 | 54 | S&F capacitor AC for 230 volts 50 Hz of capacity 2.0/2.25/2.5 Mfd. | 590 | Each | |
| 55 | 55 | S&F capacitor AC for 230 volts 50 Hz of capacity 3.15 Mfd. | 10 | Each | |
| 56 | 56 | S&F capacitor AC for 230 volts 50 Hz of capacity 4.0 Mfd. | 15 | Each | |
| 57 | 57 | Painting of ceiling fan 1200/1400 mm including scrapping, cleaning and removing dust from the blade an body and applying two coat of enamel paint over & one coat of primer all as directed by Engr-in-charge. | 160 | Each | |
| 58 | 58 | Painting of exhaust fan 450 mm industrial type including scrapping, cleaning and removing dust from the blade an body and applying two coat of enamel paint over & one coat of primer all as directed by Engr-in-charge | 40 | Each | |
| 59 | 59 | Painting of exhaust fan 300 mm domestic type including scrapping, cleaning and removing dust from the blade an body and applying two coat of enamel paint over & one coat of primer all as directed by Engr-in-chage | 50 | Each | |
| 60 | 60 | S&F PVC insulated PVC sheathed copper flexible wire multistranded 4sqmm 3 core, ISI marked | 40 | RM | |
| 61 | 61 | S&F in repair thermostat ISI marked suitable for geysers 25 Ltrs to 50 Ltrs Capacity. Make- Bajaj/Venus/Recold all as specified and directed. | 35 | Each | |
| 62 | 62 | S&F in repair fusible plug marked suitable for 25 and 50 ltrs capacity Geysers all as specified and directed. | 30 | Each | |
| 63 | 63 | S&F in repair heating element Marked round/triangular bas, push type or thread type including rubber washers for 1.5/2.0 KW all as specified and directed. | 40 | Each | |
| 64 | 64 | S&F in repair inner water container made of SS, vertical or horizontal type for 25/50 ltr capacity geyser all as specified and directed. | 14 | Each | |
| 65 | 65 | S&F in repair of aparatus plate suitable for vertical/horizontal type Geyser 25 or 50 ltr cap all as specified and directed. | 20 | Each | |
| 66 | 66 | S&F in repair heavy duty PVC connections pipe with brass hexagonal adopters at both side 15mm dia and 450mm long for hot /cold water all as specified and directed. | 25 | Each | |
| 67 | 67 | M&L for testing of earth resistance value of building earth for electrical purpose, using analog/digital earth resistance tester by suitably inserting spikes as per norms and recording earth resistance value of building in presence of MES Rep and User rep and submission of recorded value in form of hard copy duly signed all as specified and directed. | 80 | Each | |
| 68 | 68 | M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion. | 20 | Each |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender