Repair And Renovation Of Paddapukur P . H . E , Kolkata Police ( 1St Phase ) . ( 1St Call )
Tender Value
3.65 Crore
Estimated cost
Bid Submission
28 Nov 2019
0 days left
EMD
7.30 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Paddapukur P.H.E → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair And Renovation Of Paddapukur P . H . E , Kolkata Police ( 1St Phase ) . ( 1St Call )
BOQ
| Name of Work: Repair and renovation of Paddapukur P.H.E,Kolkata Police (1st Phase). | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Civil works | BI01010001010000000000000515BI0100001112 | ||
| 2 | 2 | Dismantling all types of plain cement concrete works stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.\nUpto 150 mm thick a). In ground floor including roof. | BI01010001010000000000000515BI0100001113 | 10.725 | Cu.M. |
| 3 | 3 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a). In ground floor including roof. | BI01010001010000000000000515BI0100001114 | 9.934 | Cu.M. |
| 4 | 4 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m b). In 1st Floor | BI01010001010000000000000515BI0100001115 | 9.934 | Cu.M. |
| 5 | 5 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m c). In 2nd Floor | BI01010001010000000000000515BI0100001116 | 7.834 | Cu.M. |
| 6 | 6 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m d). In 3rd Floor | BI01010001010000000000000515BI0100001117 | 7.511 | Cu.M. |
| 7 | 7 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed\nwithin a lead of 75 m. including stacking of steel bars. a). In ground floor including roof. | BI01010001010000000000000515BI0100001118 | 45.22 | Cu.M. |
| 8 | 8 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed\nwithin a lead of 75 m. including stacking of steel bars. b). In 1st Floor | BI01010001010000000000000515BI0100001119 | 43.5 | Cu.M. |
| 9 | 9 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed\nwithin a lead of 75 m. including stacking of steel bars. c). In 2nd Floor | BI01010001010000000000000515BI0100001120 | 38.2 | Cu.M. |
| 10 | 10 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed\nwithin a lead of 75 m. including stacking of steel bars. d). In 3rd Floor | BI01010001010000000000000515BI0100001121 | 15.533 | Cu.M. |
| 11 | 11 | Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge | BI01010001010000000000000515BI0100001122 | 780.74 | Sq.M. |
| 12 | 12 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. | BI01010001010000000000000515BI0100001123 | 21181 | Sq.M. |
| 13 | 13 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into\ntruck and cleaning the site in all respect as per direction of Engineer in charge | BI01010001010000000000000515BI0100001124 | 1170 | Cu.M. |
| 14 | 14 | Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately). Medium size plant of girth of exposed stem above 75 mm. but not exceeding 150 mm. lift upto 6 mtr. | BI01010001010000000000000515BI0100001125 | 91 | Each |
| 15 | 15 | Welding in M.S. structural work with gas or electric\nTack weld | BI01010001010000000000000515BI0100001126 | 8215.52 | Cm run |
| 16 | 16 | Taking out heavy iron grated door or window (jail pattern or existing) with locking arrangement after cutting out from walls and refixing the same including mending all damages.[Mending charges to be paid separately] | BI01010001010000000000000515BI0100001127 | 32.5 | Sq.M. |
| 17 | 17 | Reparing collapsible gate by cutting out all rivets as necessary reassambling all members including welding pieces of channels, sraightening bent bars and rivetting with new rivets and fitting in position and painting two coats. | BI01010001010000000000000515BI0100001128 | 29.25 | Sq.M. |
| 18 | 18 | Easing and oiling, cleaning collapsible gate and repairing to locking arrangements | BI01010001010000000000000515BI0100001129 | 29.2 | Sq.M. |
| 19 | 19 | Taking out M.S. or W.I. Grills from wooden frame including cutting lugs from masonry wall and refitting the same and mending good damages after repairs. (Excluding the cost of necessary repair of damages) or doing any other necessary works. | BI01010001010000000000000515BI0100001130 | 293 | Each |
| 20 | 20 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) | BI01010001010000000000000515BI0100001131 | 559.78 | Sq.M. |
| 21 | 21 | Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. | BI01010001010000000000000515BI0100001132 | 910 | Sq.M. |
| 22 | 22 | Taking out old iron higes and fitting, fixing the same with new steel screws.\n125 mm. Long butt hinge. | BI01010001010000000000000515BI0100001133 | 1536 | Each |
| 23 | 23 | Scraping and removing greasy soot from walls or ceiling of kitchen or similar smoke affected rooms and preparing the surface. | BI01010001010000000000000515BI0100001134 | 32.5 | Sq.M. |
| 24 | 24 | Repairing crack in wall by cement grouting (1 : 2) including widening the crack on the surface (into V section) cleaning and packing the same with cement mortar (1 : 2) andfinishing off to match with adjacent surface.\n(Cement-69 Kg/100 m) | BI01010001010000000000000515BI0100001135 | 74.783 | %Mtr. |
| 25 | 25 | Anti-termite treatment to the soil under floor with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight including drilling vertically 12mm. dia holes at the junction of floor and wall at 300mm. interval to reach the soil below using hand operated pressure pump to squirt chemical emulsion into the pump to squirt chemical emulsion into the holes at the rate of one litre per hole. The holes shall be sealed after operation to match with the existing floor. The entire work is to be carried out as per specification laid down in para 4.3.1.4 of code I.S.-6313 (Part-III)- 1981. | BI01010001010000000000000515BI0100001136 | 747.5 | Sq.M. |
| 26 | 26 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment] | BI01010001010000000000000515BI0100001137 | 376.4 | Sq.M. |
| 27 | 27 | Epoxy bonding of new concrete to old concrete | BI01010001010000000000000515BI0100001138 | 1882 | Sq.M. |
| 28 | 28 | Patching of damaged concrete surface with polymer concrete (25 mm nominal thick) and curing compounds, initiator and promoter, available in present formulations, to be applied as per instructions of manufacturer and as approved by the Engineer. | BI01010001010000000000000515BI0100001139 | 1882 | Sq.M. |
| 29 | 29 | Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge.(DSR -2016 P-425,V-2) | BI01010001010000000000000515BI0100001140 | 1882 | Sq.M. |
| 30 | 30 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in\n ground floor. | BI01010001010000000000000515BI0100001141 | 91.816 | Sq.M. |
| 31 | 31 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in b). In 1st Floor | BI01010001010000000000000515BI0100001142 | 52.038 | Sq.M. |
| 32 | 32 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in c). In 2nd Floor | BI01010001010000000000000515BI0100001143 | 52.038 | Sq.M. |
| 33 | 33 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in d). In 3rd Floor | BI01010001010000000000000515BI0100001144 | 85.491 | Sq.M. |
| 34 | 34 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In- Charge.\n26.30.1 Upto and including 12mm dia.(DSR P-423,V-2) | BI01010001010000000000000515BI0100001145 | 2314 | Each |
| 35 | 35 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding\ncost of chipping over concrete surface]\nWith 1:6 cement mortar\n20 mm thk Plaster \na). In ground floor | BI01010001010000000000000515BI0100001146 | 598.4 | Sq.m |
| 36 | 36 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding\ncost of chipping over concrete surface]\nWith 1:6 cement mortar\n20 mm thk Plaster b). In 1st Floor | BI01010001010000000000000515BI0100001147 | 598.4 | Sq.m |
| 37 | 37 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding\ncost of chipping over concrete surface]\nWith 1:6 cement mortar\n20 mm thk Plaster \nc). In 2nd Floor | BI01010001010000000000000515BI0100001148 | 514.624 | Sq.m |
| 38 | 38 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding\ncost of chipping over concrete surface]\nWith 1:6 cement mortar\n20 mm thk Plaster \nd). In 3rd Floor | BI01010001010000000000000515BI0100001149 | 478.72 | Sq.m |
| 39 | 39 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 1:6 cement mortar\n15 mm thk Plaster a). In ground floor | BI01010001010000000000000515BI0100001150 | 5306 | Sq.m |
| 40 | 40 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 1:6 cement mortar\n15 mm thk Plaster b). In 1st Floor | BI01010001010000000000000515BI0100001151 | 3942.5 | Sq.m |
| 41 | 41 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 1:6 cement mortar\n15 mm thk Plaster c). In 2nd Floor | BI01010001010000000000000515BI0100001152 | 3085.44 | Sq.m |
| 42 | 42 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 1:6 cement mortar\n15 mm thk Plaster d). In 3rd Floor | BI01010001010000000000000515BI0100001153 | 2914.02 | Sq.m |
| 43 | 43 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 1:4 cement mortar\n10 mm thk Plaster a). In ground floor | BI01010001010000000000000515BI0100001154 | 1080.03 | Sq.m |
| 44 | 44 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 1:4 cement mortar\n10 mm thk Plaster b). In 1st Floor | BI01010001010000000000000515BI0100001155 | 1080.03 | Sq.m |
| 45 | 45 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 1:4 cement mortar\n10 mm thk Plaster c). In 2nd Floor | BI01010001010000000000000515BI0100001156 | 810.02 | Sq.m |
| 46 | 46 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 1:4 cement mortar\n10 mm thk Plaster d). In 3rd Floor | BI01010001010000000000000515BI0100001157 | 765.019 | Sq.m |
| 47 | 47 | Closing gap between door and window frame and jambs with cement mortar (1:3) including removing old mortar (throughout entire surface of contact) and cleaning the joint. (Cement 0.012 Cu.m/100 Mtr.)\n(This item is not payable for new works). | BI01010001010000000000000515BI0100001158 | 2692.2 | Mtr. |
| 48 | 48 | Rendering the Surface of walls and ceiling with White Cement base\nWATER PROOF wall putty of approved make & brand.(1.5 mm thick) | BI01010001010000000000000515BI0100001159 | 5250.72 | Sqm |
| 49 | 49 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)\nTwo Coats\nSolvent based interior grade Acrylic Primer | BI01010001010000000000000515BI0100001160 | 21670.5 | Sq.m |
| 50 | 50 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.\nTwo Coats | BI01010001010000000000000515BI0100001161 | 21670.5 | Sq.m |
| 51 | 51 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the\nEIC.\ntwo coat | BI01010001010000000000000515BI0100001162 | 5813.5 | Sq.m |
| 52 | 52 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.\nb) Premium 100% Acrylic Emulsion\nTwo Coats\nIn Ground Floor: | BI01010001010000000000000515BI0100001163 | 5814.14 | Sq.m |
| 53 | 53 | Red oxide wash of approved shade including cleaning and smoothening surface thoroughly (without specific permission from the Engineer-incharge this item of work must not be done on an old painted surface which has not received such red oxide wash before) :\nTwo coats (on new works only).\nGround Floor | BI01010001010000000000000515BI0100001164 | 149.5 | Sq.m |
| 54 | 54 | Red oxide wash of approved shade including cleaning and smoothening surface thoroughly (without specific permission from the Engineer-incharge this item of work must not be done on an old painted surface which has not received such red oxide wash before) :\nTwo coats (on new works only). b). In 1st Floor | BI01010001010000000000000515BI0100001165 | 137.5 | Sq.m |
| 55 | 55 | Red oxide wash of approved shade including cleaning and smoothening surface thoroughly (without specific permission from the Engineer-incharge this item of work must not be done on an old painted surface which has not received such red oxide wash before) :\nTwo coats (on new works only). c). In 2nd Floor | BI01010001010000000000000515BI0100001166 | 107.6 | Sq.m |
| 56 | 56 | Red oxide wash of approved shade including cleaning and smoothening surface thoroughly (without specific permission from the Engineer-incharge this item of work must not be done on an old painted surface which has not received such red oxide wash before) :\nTwo coats (on new works only). d). In 3rd Floor | BI01010001010000000000000515BI0100001167 | 101.7 | Sq.m |
| 57 | 57 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :\nb) On steel or other metal surface :\nWith super gloss (hi-gloss) -\n(iv) Two coats (with any shade except white)\n | BI01010001010000000000000515BI0100001168 | 496.34 | Sq.m |
| 58 | 58 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :\n(a) On timber or plastered surface :\n(iv) Two coats (with any shade except white) With super gloss( hi-gloss) | BI01010001010000000000000515BI0100001169 | 166.8 | SQM |
| 59 | 59 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. | BI01010001010000000000000515BI0100001170 | 577.3 | Sq.m |
| 60 | 60 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :\nOn timber or plastered surface :\nWith super gloss (hi-gloss) -\nTwo coats (white in shade) | BI01010001010000000000000515BI0100001171 | 410.5 | Sq.m |
| 61 | 61 | Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white\ncement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency].\nWith Chawk Dungri\nArea of each tile exceeding 0.6 sq.m but not excedding 1 sq.m. Gr Floor | BI01010001010000000000000515BI0100001172 | 10.5 | Sq.m |
| 62 | 62 | Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white\ncement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency].\nWith Chawk Dungri\nArea of each tile exceeding 0.6 sq.m but not excedding 1 sq.m b). In 1st Floor | BI01010001010000000000000515BI0100001173 | 21 | Sq.m |
| 63 | 63 | Supplying fitting and fixing 15 to 18 mm thick Marble\nslab/Tile in riser of step or skirting (upto 300 mm ht) over 15mm (avg) thick base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/ Sq.m at back side of marble and jointed with white cement slurry @ 2.2 kg/ Sq.m with necessary pigments including grinding and Granite Polishing.\n[White cement and Pigment to be supplied by the Agency] Gr Floor area each tile exceeding 0.35 sq.m | BI01010001010000000000000515BI0100001174 | 7 | Sq.m |
| 64 | 64 | artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and roun | BI01010001010000000000000515BI0100001175 | 7 | Sq.m |
| 65 | 65 | Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Marble Stone. | BI01010001010000000000000515BI0100001176 | 54.6 | Mtr. |
| 66 | 66 | Extra cost of labour for Marble Stone Floor in treads of Steps. | BI01010001010000000000000515BI0100001177 | 26 | Sq.m |
| 67 | 67 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor\nas per relevant IS codes.\nPakur Variety | BI01010001010000000000000515BI0100001178 | 7.172 | Cum |
| 68 | 68 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Ground Floor\nPakur variety\n In First Floor | BI01010001010000000000000515BI0100001179 | 34.654 | Cu.M. |
| 69 | 69 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Ground Floor\nPakur variety\n In 3rd Floor | BI01010001010000000000000515BI0100001180 | 31.2 | Cu.M. |
| 70 | 70 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Ground Floor\nPakur variety\n In 4th Floor | BI01010001010000000000000515BI0100001181 | 31.2 | Cu.M. |
| 71 | 71 | Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete.\n[Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] Area of each Granite slab 0.6 to 1.0 Square meter.\nGr floor | BI01010001010000000000000515BI0100001182 | 38.62 | Sq.m |
| 72 | 72 | Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with\nadmixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] Area of each Granite slab 0.6 to 1.0 Square meter. \nb). In 1st Floor | BI01010001010000000000000515BI0100001183 | 38.62 | Sq.m |
| 73 | 73 | Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with\nadmixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] Area of each Granite slab 0.6 to 1.0 Square meter. c). In 2nd Floor | BI01010001010000000000000515BI0100001184 | 38.62 | Sq.m |
| 74 | 74 | Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with\nadmixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] Area of each Granite slab 0.6 to 1.0 Square meter. . d). In 3rd Floor | BI01010001010000000000000515BI0100001185 | 38.62 | Sq.m |
| 75 | 75 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.\nWall\nwith polymerised adhesive and Epoxy grout Pointing including spacer- 2 mm ( When Tiles are laid over existing hard ready surface)\nArea of each tile upto 0.09 Sq.m [using adhesive 3 mm\nthick]\n(i) Coloured decorative\nGround Floor | BI01010001010000000000000515BI0100001186 | 150.372 | Sq.m |
| 76 | 76 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.\nWall\nwith polymerised adhesive and Epoxy grout Pointing including spacer- 2 mm ( When Tiles are laid over existing hard ready surface)\nArea of each tile upto 0.09 Sq.m [using adhesive 3 mm\nthick]\n(i) Coloured decorative b). In 1st Floor | BI01010001010000000000000515BI0100001187 | 150.372 | Sq.m |
| 77 | 77 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.\nWall\nwith polymerised adhesive and Epoxy grout Pointing including spacer- 2 mm ( When Tiles are laid over existing hard ready surface)\nArea of each tile upto 0.09 Sq.m [using adhesive 3 mm\nthick]\n(i) Coloured decorative c). In 2nd Floor | BI01010001010000000000000515BI0100001188 | 123.767 | Sq.m |
| 78 | 78 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.\nWall\nwith polymerised adhesive and Epoxy grout Pointing including spacer- 2 mm ( When Tiles are laid over existing hard ready surface)\nArea of each tile upto 0.09 Sq.m [using adhesive 3 mm\nthick]\n(i) Coloured decorative d). In 3rd Floor | BI01010001010000000000000515BI0100001189 | 108.451 | Sq.m |
| 79 | 79 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).\nb) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength >\n1500 N | BI01010001010000000000000515BI0100001190 | 67.152 | Sq.m |
| 80 | 80 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).Sizes-600 mm x600mm x10 mm with breaking strength >1500 N b). In 1st Floor | BI01010001010000000000000515BI0100001191 | 67.152 | Sq.m |
| 81 | 81 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). Sizes-600 mm x600mm x10 mm with breaking strength >1500 Nc). In 2nd Floor | BI01010001010000000000000515BI0100001192 | 65.195 | Sq.m |
| 82 | 82 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). d).Sizes-600 mm x600mm x10 mm with breaking strength >1500 N In 3rd Floor | BI01010001010000000000000515BI0100001193 | 65.195 | Sq.m |
| 83 | 83 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.\n(i) Pakur Variety Gr Floor | BI01010001010000000000000515BI0100001194 | 45.22 | Cu.M. |
| 84 | 84 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.\n(i) Pakur Variety b). In 1st Floor | BI01010001010000000000000515BI0100001195 | 43.5 | Cu.M. |
| 85 | 85 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.\n(i) Pakur Variety c). In 2nd Floor | BI01010001010000000000000515BI0100001196 | 38.2 | Cu.M. |
| 86 | 86 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.\n(i) Pakur Variety d). In 3rd Floor | BI01010001010000000000000515BI0100001197 | 14.95 | Cu.M. |
| 87 | 87 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. \nPakur Variety Gr Floor | BI01010001010000000000000515BI0100001198 | 26.325 | Cu.M. |
| 88 | 88 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. \nPakur Variety b). In 1st Floor | BI01010001010000000000000515BI0100001199 | 11.487 | Cu.M. |
| 89 | 89 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. \nPakur Variety c). In 2nd Floor | BI01010001010000000000000515BI0100001200 | 11.487 | Cu.M. |
| 90 | 90 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. \nPakur Varietyd). In 3rd Floor | BI01010001010000000000000515BI0100001201 | 11.487 | Cu.M. |
| 91 | 91 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4 m\nTor steel/Mild Steel\nSAIL/ TATA/RINL\nGr floor | BI01010001010000000000000515BI0100001202 | 10.156 | M.T. |
| 92 | 92 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4 m\nTor steel/Mild Steel\nSAIL/ TATA/RINL b). In 1st Floor | BI01010001010000000000000515BI0100001203 | 4.35 | M.T. |
| 93 | 93 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.\nFor works in foundation and upto roof of ground floor/upto 4 m\nTor steel/Mild Steel\nSAIL/ TATA/RINL c). In 2nd Floor | BI01010001010000000000000515BI0100001204 | 3.75 | M.T. |
| 94 | 94 | Reinforcement for reinforced concrete work in all sorts of structure \nincluding distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4 m\nTor steel/Mild Steel\nSAIL/ TATA/RINL d). In 3rd Floor | BI01010001010000000000000515BI0100001205 | 3.85 | M.T. |
| 95 | 95 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)\nSteel shuttering or 9 to 12 mm thick approved quality ply board shuttering\nin any concrete work\nGr floor | BI01010001010000000000000515BI0100001206 | 607.151 | Sq.m |
| 96 | 96 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)\nSteel shuttering or 9 to 12 mm thick approved quality ply board shuttering\nin any concrete work b). In 1st Floor | BI01010001010000000000000515BI0100001207 | 382.151 | Sq.m |
| 97 | 97 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)\nSteel shuttering or 9 to 12 mm thick approved quality ply board shuttering\nin any concrete work c). In 2nd Floor | BI01010001010000000000000515BI0100001208 | 382.151 | Sq.m |
| 98 | 98 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)\nSteel shuttering or 9 to 12 mm thick approved quality ply board shuttering\nin any concrete work d). In 3rd Floor | BI01010001010000000000000515BI0100001209 | 382.151 | Sq.m |
| 99 | 99 | a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.\nGrill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtrGrill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.\nGr floor | BI01010001010000000000000515BI0100001210 | 14.482 | Qntl |
| 100 | 100 | a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.\nGrill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtrGrill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. b). In 1st Floor | BI01010001010000000000000515BI0100001211 | 14.482 | Qntl |
| 101 | 101 | a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.\nGrill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. c). In 2nd Floor | BI01010001010000000000000515BI0100001212 | 13.832 | Qntl |
| 102 | 102 | a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground\nfloor. Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. d). In 3rd Floor | BI01010001010000000000000515BI0100001213 | 13.832 | Qntl |
| 103 | 103 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]\nGround Floor | BI01010001010000000000000515BI0100001214 | 9.75 | Sqm. |
| 104 | 104 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] b). In 1st Floor | BI01010001010000000000000515BI0100001215 | 9.75 | Sqm. |
| 105 | 105 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]c). In 2nd Floor | BI01010001010000000000000515BI0100001216 | 9.425 | Sqm. |
| 106 | 106 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] d). In 3rd Floor | BI01010001010000000000000515BI0100001217 | 10.01 | Sqm. |
| 107 | 107 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).\nSal : Malayasian\nGround Floor | BI01010001010000000000000515BI0100001218 | 0.792 | Cu.M. |
| 108 | 108 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).\nSal : Malayasian b). In 1st Floor | BI01010001010000000000000515BI0100001219 | 0.792 | Cu.M. |
| 109 | 109 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).\nSal : Malayasian c). In 2nd Floor | BI01010001010000000000000515BI0100001220 | 0.792 | Cu.M. |
| 110 | 110 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).\nSal : Malayasian d). In 3rd Floor | BI01010001010000000000000515BI0100001221 | 0.582 | Cu.M. |
| 111 | 111 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other\nfittings \n32 mm thick shutters (single leaf)\nin ground floor. | BI01010001010000000000000515BI0100001222 | 55.467 | Sq.m |
| 112 | 112 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other\nfittings \n32 mm thick shutters (single leaf) b). In 1st Floor | BI01010001010000000000000515BI0100001223 | 55.467 | Sq.m |
| 113 | 113 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other\nfittings \n32 mm thick shutters (single leaf) c). In 2nd Floor | BI01010001010000000000000515BI0100001224 | 55.467 | Sq.m |
| 114 | 114 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other\nfittings \n32 mm thick shutters (single leaf) d). In 3rd Floor | BI01010001010000000000000515BI0100001225 | 55.467 | Sq.m |
| 115 | 115 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other\nfittings \n32 mm thick shutters (single leaf) e). In 4th Floor | BI01010001010000000000000515BI0100001226 | 55.467 | Sq.m |
| 116 | 116 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\n (i) 32 mm thick\nIn ground floor. | BI01010001010000000000000515BI0100001227 | 40.131 | Sq.m |
| 117 | 117 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\n (i) 32 mm thick b). In 1st Floor | BI01010001010000000000000515BI0100001228 | 40.131 | Sq.m |
| 118 | 118 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\n(i) 32 mm thick c). In 2nd Floor | BI01010001010000000000000515BI0100001229 | 40.131 | Sq.m |
| 119 | 119 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\n (i) 32 mm thick d). In 3rd Floor | BI01010001010000000000000515BI0100001230 | 20.066 | Sq.m |
| 120 | 120 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to\nsafisfy IS: 4020 door testing performance criteria..\n(i) 66mm x 90mm | BI01010001010000000000000515BI0100001231 | 492.128 | Mtr. |
| 121 | 121 | Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required) | BI01010001010000000000000515BI0100001232 | 3105.13 | SQM |
| 122 | 122 | Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades. | BI01010001010000000000000515BI0100001233 | 497.705 | kg |
| 123 | 123 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately)\n(a) Upto area 2.5 Sq.m | BI01010001010000000000000515BI0100001234 | 302.981 | Sqm |
| 124 | 124 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.\n4mm thick clear glass. | BI01010001010000000000000515BI0100001235 | 304.2 | Sqm |
| 125 | 125 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs,\nsills and soffits.\n50 mm thick | BI01010001010000000000000515BI0100001236 | 32.5 | Sqm |
| 126 | 126 | Wooden venetian/ Louvered valves, fitted and fixed with plated hooks complete\n19mm thick valves.\n1st class best Indian teak. | BI01010001010000000000000515BI0100001237 | 66.43 | Sqm |
| 127 | 127 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.\nIn ground floor. \n3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).\nUsing grey cement\n35 mm. thick\nGr Floor | BI01010001010000000000000515BI0100001238 | 244.67 | Sq.m |
| 128 | 128 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.\nIn ground floor. \n3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).\nUsing grey cement\n35 mm. thick b). In 1st Floor | BI01010001010000000000000515BI0100001239 | 245.76 | Sq.m |
| 129 | 129 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.\nIn ground floor. \n3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).\nUsing grey cement\n35 mm. thick c). In 2nd Floor | BI01010001010000000000000515BI0100001240 | 246.78 | Sq.m |
| 130 | 130 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.\nIn ground floor. \n3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).\nUsing grey cement\n35 mm. thick d). In 3rd Floor | BI01010001010000000000000515BI0100001241 | 243.76 | Sq.m |
| 131 | 131 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. a). In ground floor including roof. | BI01010001010000000000000515BI0100001242 | 244.67 | Sq.M. |
| 132 | 132 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. b). In 1st Floor | BI01010001010000000000000515BI0100001243 | 245.76 | Sq.M. |
| 133 | 133 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. c). In 2nd Floor | BI01010001010000000000000515BI0100001244 | 246.78 | Sq.M. |
| 134 | 134 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. d). In 3rd Floor | BI01010001010000000000000515BI0100001245 | 243.76 | Sq.M. |
| 135 | 135 | Removing old paint from blistered painted surface of steel or other metal by chipping including scraping and cleaning and exposing the original\nsurface. | BI01010001010000000000000515BI0100001246 | 200 | Sq.M. |
| 136 | 136 | Removing thick layers of paint from heavily cracked and blistered painted surface of timber by careful burning with blow lamp including smoothening exposed surface of timber with pumice stone or glass and preparing the same for fresh treatment. | BI01010001010000000000000515BI0100001247 | 295 | Sq.M. |
| 137 | 137 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. | BI01010001010000000000000515BI0100001248 | 616.5 | CUM |
| 138 | 138 | Granular Sub-base with Graded Material (Table:- 400-1) : Plant Mix Method:\nConstruction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of specifications for Road & Bridge Works of MoRT&H (5th Revision). (Page no: 243, item no: 4.08) GRADING-V, G.S.B. (250MM Compacted thickness at Bottom layer) | BI01010001010000000000000515BI0100001249 | 225 | CUM |
| 139 | 139 | Water Bound Macadam Base Course :- Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). Grading-II aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm) | BI01010001010000000000000515BI0100001250 | 225 | CUM |
| 140 | 140 | 80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-200 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of\nsand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge.\n[Note: Subgrade CBR shouldnot be less than 5] (ii) Coloured Decorative | BI01010001010000000000000515BI0100001251 | 900 | SQM |
| 141 | 141 | Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without einforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in- Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compactedand curing the morter joints for atleast 3 days including cost and carriage of all materials complete. | BI01010001010000000000000515BI0100001252 | 278 | RM |
| 142 | 142 | (a) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary. Around pheriferi of boundary wall | BI01010001010000000000000515BI0100001253 | 350 | Mtr |
| 143 | 143 | Supplying fitting and fixing 600 mm (+/- 30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc. (The rate is exclusive of the cost of posts) Around pheriferi of boundary wall\n | BI01010001010000000000000515BI0100001254 | 350 | Mtr |
| 144 | 144 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. for structural member of specified section less than 22.5 kg | BI01010001010000000000000515BI0100001255 | 1.2 | MT |
| 145 | 145 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. | BI01010001010000000000000515BI0100001256 | 181.8 | Sq.M |
| 146 | 146 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : on steel surface with super gloss .two coat with any side except | BI01010001010000000000000515BI0100001257 | 181.8 | Sq.M |
| 147 | 147 | Supplying ready mixed concrete of M25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work, compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier] In ground floor and foundation.\n(ii) With approved concrete pump | BI01010001010000000000000515BI0100001258 | 27.95 | Cum. |
| 148 | 148 | Plumbing & Sanitary\n Labour for dismantling G.I. pipe with fittings.\n25 mm | BI01010001010000000000000515BI0100001259 | 1259.39 | Mtr. |
| 149 | 149 | Labour for dismantling G.I. pipe with fittings. 32 mm | BI01010001010000000000000515BI0100001260 | 1156.9 | Mtr. |
| 150 | 150 | Labour for dismantling G.I. pipe with fittings. 40 mm | BI01010001010000000000000515BI0100001261 | 762.372 | Mtr. |
| 151 | 151 | Labour for dismantling G.I. pipe with fittings. 50 mm | BI01010001010000000000000515BI0100001262 | 1328.34 | Mtr. |
| 152 | 152 | Labour for dismantling G.I. pipe with fittings. 65 mm | BI01010001010000000000000515BI0100001263 | 1328.34 | Mtr. |
| 153 | 153 | Labour for dismantling G.I. pipe with fittings. 80 mm | BI01010001010000000000000515BI0100001264 | 1328.34 | Mtr. |
| 154 | 154 | Labour for dismantling G.I. pipe with fittings. 100 mm | BI01010001010000000000000515BI0100001265 | 1328.34 | Mtr. |
| 155 | 155 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings\n(tested to 21 kg per sq. cm.). \n25 mm dia | BI01010001010000000000000515BI0100001266 | 13 | Each |
| 156 | 156 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.\na). Exposed Work(CPVC Pipes Class-1, SDR-11) 25 mm Dia | BI01010001010000000000000515BI0100001267 | 333.125 | Mtr. |
| 157 | 157 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including\nall specials. No separate payment will be made for accesories, specials.\na). Exposed Work(CPVC Pipes Class-1, SDR-11) 32 mm Dia | BI01010001010000000000000515BI0100001268 | 341.25 | Mtr. |
| 158 | 158 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.\na). Exposed Work(CPVC Pipes Class-1, SDR-11) \n40 mm Dia | BI01010001010000000000000515BI0100001269 | 357.5 | Mtr. |
| 159 | 159 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.\na). Exposed Work(CPVC Pipes Class-1, SDR-11 50 mm Dia | BI01010001010000000000000515BI0100001270 | 341.25 | Mtr. |
| 160 | 160 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (i) 100 mm dia | BI01010001010000000000000515BI0100001271 | 10 | Each |
| 161 | 161 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (iv) 50 mm dia | BI01010001010000000000000515BI0100001272 | 10 | Each |
| 162 | 162 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).v (v) 40 mm dia | BI01010001010000000000000515BI0100001273 | 10 | Each |
| 163 | 163 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (vi) 32 mm dia | BI01010001010000000000000515BI0100001274 | 10 | Each |
| 164 | 164 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (vii) 25 mm dia | BI01010001010000000000000515BI0100001275 | 10 | Each |
| 165 | 165 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\nDouble Socketed 3 Meter Length (a) 75 mm | BI01010001010000000000000515BI0100001276 | 576.623 | Mtr. |
| 166 | 166 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\nDouble Socketed 3 Meter Length (b) 110 mm | BI01010001010000000000000515BI0100001277 | 2313.23 | Mtr. |
| 167 | 167 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992Double socketed 1.2 mtr length (b) 110 mm | BI01010001010000000000000515BI0100001278 | 413.127 | Mtr. |
| 168 | 168 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\nDouble socketed .9 mtr length (b) 110 mm | BI01010001010000000000000515BI0100001279 | 137.943 | Mtr. |
| 169 | 169 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\nDouble socketed .6 mtr length (b) 110 mm | BI01010001010000000000000515BI0100001280 | 275.535 | Mtr. |
| 170 | 170 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\n(B). Fittings Coupler b). 110 mm | BI01010001010000000000000515BI0100001281 | 185 | Each |
| 171 | 171 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\nPlain Tee b). 110 mm | BI01010001010000000000000515BI0100001282 | 195 | Each |
| 172 | 172 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\nPlain Y b). 110 mm | BI01010001010000000000000515BI0100001283 | 221 | Each |
| 173 | 173 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 \nBend 45° b). 110 mm | BI01010001010000000000000515BI0100001284 | 455 | Each |
| 174 | 174 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 \nBend 87.5° b). 110 mm | BI01010001010000000000000515BI0100001285 | 728 | Each |
| 175 | 175 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 \nDoor Bend (T.S.) b). 110 mm | BI01010001010000000000000515BI0100001286 | 117 | Each |
| 176 | 176 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 \nVent Cowl b). 110 mm | BI01010001010000000000000515BI0100001287 | 39 | Each |
| 177 | 177 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\n Pipe clip b). 110 mm | BI01010001010000000000000515BI0100001288 | 1950 | Each |
| 178 | 178 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\n Pipe clip c). 160 mm | BI01010001010000000000000515BI0100001289 | 2600 | Each |
| 179 | 179 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\n 125/110 P Trap With W.C. Ring 75 mm | BI01010001010000000000000515BI0100001290 | 163 | Each |
| 180 | 180 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 \nReducer Tee 110x75mm 75 mm | BI01010001010000000000000515BI0100001291 | 325 | Each |
| 181 | 181 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer incharge. (Payment will be made on centre line measurement of the total pipeline including specials.A). Above Ground a). 75 mm | BI01010001010000000000000515BI0100001292 | 1201.3 | Mtr |
| 182 | 182 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer incharge. (Payment will be made on centre line measurement of the total pipeline including specials.A). Above Ground b). 110 mm | BI01010001010000000000000515BI0100001293 | 1824.26 | Mtr |
| 183 | 183 | Repairing works\nSupplying, fitting and fixing low-down cistern parts.\n(i) Internal fittings for cistern complete of approved make. | BI01010001010000000000000515BI0100001294 | 26 | Each set |
| 184 | 184 | Repairing works\nSupplying, fitting and fixing low-down cistern parts. (ii) Outlet Assembly | BI01010001010000000000000515BI0100001295 | 26 | Each |
| 185 | 185 | Repairing works\nSupplying, fitting and fixing low-down cistern parts. (iii) Intlet Assembly | BI01010001010000000000000515BI0100001296 | 26 | Each |
| 186 | 186 | Repairing works\nSupplying, fitting and fixing low-down cistern parts. (iv) Rubber Kid | BI01010001010000000000000515BI0100001297 | 26 | Each |
| 187 | 187 | Repairing works\nSupplying, fitting and fixing low-down cistern parts. (v) Knob | BI01010001010000000000000515BI0100001298 | 26 | Each |
| 188 | 188 | Repairing works\nSupplying, fitting and fixing low-down cistern parts. (vi) Brackets (pair) | BI01010001010000000000000515BI0100001299 | 26 | Each |
| 189 | 189 | Repairing works\nSupplying, fitting and fixing low-down cistern parts. b). E. W.C. & Anglo-Indian W.C. | BI01010001010000000000000515BI0100001300 | 26 | Each |
| 190 | 190 | Dismantling wash basin with brackets with or without waste fittings. | BI01010001010000000000000515BI0100001301 | 26 | Each |
| 191 | 191 | Refixing wash basin with brackets with or without waste fittings. | BI01010001010000000000000515BI0100001302 | 26 | Each |
| 192 | 192 | Refixing sink with brackets with or without waste fittings. (ii) Above 450 mm and upto 600 mm length | BI01010001010000000000000515BI0100001303 | 26 | Each |
| 193 | 193 | Dismantling pillar cock of wash basin. | BI01010001010000000000000515BI0100001304 | 26 | Each |
| 194 | 194 | Supplying, fitting and fixing shower of approved brand and make.\n(a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand). | BI01010001010000000000000515BI0100001305 | 36 | Each |
| 195 | 195 | (e) Chromium plated double coat Hook(Equivalent to Code No. 35761 & Model - KUBIX of Jaquar or similar). | BI01010001010000000000000515BI0100001306 | 65 | Each |
| 196 | 196 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including\nall specials. No separate payment will be made for accesories, specials.\nb). Concealed Work CPVC Pipes Class-1,SDR-11\n15 mm Dia | BI01010001010000000000000515BI0100001307 | 427.245 | Mtr. |
| 197 | 197 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.\nb). Concealed Work CPVC Pipes Class-1,SDR-11 \n20 mm Dia | BI01010001010000000000000515BI0100001308 | 955.825 | Mtr. |
| 198 | 198 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line includingall specials. No separate payment will be made for accesories, specials.\nb). Concealed Work CPVC Pipes Class-1,SDR-11 \n25 mm Dia | BI01010001010000000000000515BI0100001309 | 427.245 | Mtr. |
| 199 | 199 | (b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar bfrand | BI01010001010000000000000515BI0100001310 | 65 | Each |
| 200 | 200 | (d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). | BI01010001010000000000000515BI0100001311 | 36 | Each |
| 201 | 201 | plain Floor Trap with Top tile & Strainer\n75 mm | BI01010001010000000000000515BI0100001312 | 65 | Each |
| 202 | 202 | Supplying, fitting and fixing 10 litre porcelain low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internnal PVC fittings. White | BI01010001010000000000000515BI0100001313 | 26 | Each |
| 203 | 203 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size | BI01010001010000000000000515BI0100001314 | 26 | Each |
| 204 | 204 | Supplying, fitting and fixing stainless steel sink complete with wastefittings and two coats of painting of C.I. brackets.a). Sink only (ii) 630 mm X 550 mm X 180 mm | BI01010001010000000000000515BI0100001315 | 36 | Each |
| 205 | 205 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (iv) 1050 mm long | BI01010001010000000000000515BI0100001316 | 32 | Each |
| 206 | 206 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. with 'P' Trap(With Vent) | BI01010001010000000000000515BI0100001317 | 26 | Each |
| 207 | 207 | Supplying, fitting and fixing glass shelf with aluminium guard rails.\n(a) Ordinary type with 5.5 mm sheet glass 600 mm X 125 mm | BI01010001010000000000000515BI0100001318 | 52 | Each |
| 208 | 208 | Supplying, fitting and fixing liquid soap container.\n(a) Cromium plated. | BI01010001010000000000000515BI0100001319 | 26 | Each |
| 209 | 209 | Supplying, fitting and fixing soap holder. Fibre Glass | BI01010001010000000000000515BI0100001320 | 26 | Each |
| 210 | 210 | Supplying, fitting and fixing towel rail with two brackets.\nAluminium (iii) 25 mm dia. and 750 mm long | BI01010001010000000000000515BI0100001321 | 39 | Each |
| 211 | 211 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.\n(i) 635 mm X 395 mm X 420 mm | BI01010001010000000000000515BI0100001322 | 13 | Each |
| 212 | 212 | Dismantling G.I. tank including disconnecting pipe connection. | BI01010001010000000000000515BI0100001323 | 13 | Each |
| 213 | 213 | Supplying P.V.C. water storage tank of approved quality with closed top\nwith lid (Black) - Multilayer c). 3000 litre capacity | BI01010001010000000000000515BI0100001324 | 10 | Each |
| 214 | 214 | Labour for hoisting plastic water storage tank.\n(ii) Above 1500 litre upto 5000 litre capacity. (a) Upto 3rd story from G.L. | BI01010001010000000000000515BI0100001325 | 40 | Each |
| 215 | 215 | Labour for punching hole in plastic water storage tank upto 50 m dia | BI01010001010000000000000515BI0100001326 | 39 | Each |
| 216 | 216 | Electrical \nDismantling the existing damaged wiring including switches, distribution bords etc. with all accessories from wall/ roof as directed by the EIC. \n\n | BI01010001010000000000000515BI0100001327 | 84 | item |
| 217 | 217 | S & F 415V 125A TPN Switch fuse Unit with SS enclosure on Angle frame (make L & T) on wall with nuts bolts etc. incl. S & F 3 nos DIN type HRC fuse. | BI01010001010000000000000515BI0100001328 | 6 | nos. |
| 218 | 218 | S & F 415V 63A TPN Switch fuse Unit with SS enclosure on Angle frame (make L & T) on wall with nuts bolts etc. incl. S & F 3 nos DIN type HRC fuse. | BI01010001010000000000000515BI0100001329 | 2 | nos |
| 219 | 219 | supply a& fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required (415V, 100 A , 4X25X5 mm Al bars., 500x150 mm sheet metal box) | BI01010001010000000000000515BI0100001330 | 6 | nos |
| 220 | 220 | Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Nicco/Havells) b) 4 x 25 sq mm | BI01010001010000000000000515BI0100001331 | 50 | mtr |
| 221 | 221 | Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Nicco/Havells) c)2core 10sq. mm | BI01010001010000000000000515BI0100001332 | 221 | mtr |
| 222 | 222 | Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Nicco/Havells) d) 2core 6sq. mm | BI01010001010000000000000515BI0100001333 | 1000 | mtr |
| 223 | 223 | Laying of the following XLPE Al armoured cable incl. 2 x 10 SWG G.I. Earth continuity conductor recessed in wall & mending good the damages to original finish:- (F-3, /5) b) 4 x 25 sq mm | BI01010001010000000000000515BI0100001334 | 50 | mtr. |
| 224 | 224 | Laying of the following XLPE Al armoured cable incl. 2 x 10 SWG G.I. Earth continuity conductor recessed in wall & mending good the damages to original finish:- (F-3, /5) c)2core 10sq. mm | BI01010001010000000000000515BI0100001335 | 221 | mtr |
| 225 | 225 | Laying of the following XLPE Al armoured cable incl. 2 x 10 SWG G.I. Earth continuity conductor recessed in wall & mending good the damages to original finish:- (F-3, /5) d) 2core 6sq. mm | BI01010001010000000000000515BI0100001336 | 1000 | mtr. |
| 226 | 226 | S & F compression type cable gland complete with brass gland, brass ring, rubber ring for dust & moisture proof entry of PVC armoured cable & finishing end of the same as per GS for the b) 4 core 25 sqmm PVC/A cable | BI01010001010000000000000515BI0100001337 | 10 | set |
| 227 | 227 | S & F compression type cable gland complete with brass gland, brass ring, rubber ring for dust & moisture proof entry of PVC armoured cable & finishing end of the same as per GS for the c) 2 core 10 sqmm PVC/A cable | BI01010001010000000000000515BI0100001338 | 56 | set |
| 228 | 228 | S & F compression type cable gland complete with brass gland, brass ring, rubber ring for dust & moisture proof entry of PVC armoured cable & finishing end of the same as per GS for the c) 2 core 6 sqmm PVC/A cable | BI01010001010000000000000515BI0100001339 | 100 | set |
| 229 | 229 | S & F 415V 6-10A perway (2+8 way) SPN MCBDB with SS enclosure double door with IP 42/43 protection with 2 pole 40 Amp isolator as incomer & 8 nos SPMCB C curve 10KA SPMCB’s as outgoing concealed in wall after wall cutting & mending good the damages to original finish including interconnection with suitable size of Cu wire neutral link & earthing attachment (Make Legrand).\n\n\n\n\n\n\n\n\n\n | BI01010001010000000000000515BI0100001340 | 45 | nos |
| 230 | 230 | Distn. wiring in 3 x 1.5 sqmm single core stranded 'FR'\nPVC insulated & unsheathed single core stranded copper wire (Gloster/Finolex/Havells) in 19 mm bore, 3 mm thick polythene pipe (for horizontal & vertical run in wall and celing portion through rigid conduit) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Legrand/Crabtree) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish\n(Ave run 6 mtr ) | BI01010001010000000000000515BI0100001341 | 1200 | PTS |
| 231 | 231 | Distn. wiring in 3 x 1.5 sqmm single core stranded 'FR'\nPVC insulated & unsheathed single core stranded copper wire (Gloster/Finolex/Havells) in 19 mm bore, 3 mm thick polythene pipe (for horizontal & vertical run in wall and celing portion through rigid conduit) complete with all accessories embedded in wall to 5Amp 230V 3 pin flush type plug socket and 5 Amp switch (Make Anchor) a) On board.\n\n | BI01010001010000000000000515BI0100001342 | 150 | pts. |
| 232 | 232 | Distn. Wiring in 22/0.3 (1.5 sqmm) single core stranded ‘FR’ PVC insulated & unshealthed single core stranded copper wire (approved make) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 250V 5A 3 Pin plug point incl. S & F 250V 5A 5 pin flush type plug socket – 2nos & piano key type switch – 2 nos. (modular type) incl. S & F earth continuty wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish; 2X22/0.3 (Ph. & N) and 1X22/0.3 as ECC, Average run 3 mtr (Separate 5A point). | BI01010001010000000000000515BI0100001343 | 100 | nos |
| 233 | 233 | Supply & fixing computer plug board modular type of 12 module GI box with cover plate recessed in wall comprising with the following (Legrand/Cabtree)\na) 6/16A socket & 16A switch --1 set\nb) 6A socket & 6A switch --2 sets\n | BI01010001010000000000000515BI0100001344 | 32 | SET |
| 234 | 234 | Supply & Fixing 240 V, 16 A, 3 pin Modular type Power plug socket (Crabtree) with 16A Modular type socket (Cabtree) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire. | BI01010001010000000000000515BI0100001345 | 116 | SET |
| 235 | 235 | S & drawing different size copper wire partly in polythine pipe embedded in wall & partly in rigid conduit pipe on wall for different power plug & SPN DB etc. a) 2x2.5 sqmm & 1x1.5 sqmm (for power plug\n1) Embeded in wall through 19 mm dia poly pipe. | BI01010001010000000000000515BI0100001346 | 230 | mtr |
| 236 | 236 | S & drawing different size copper wire partly in polythine pipe embedded in wall & partly in rigid conduit pipe on wall for different power plug & SPN DB etc. a) 2x2.5 sqmm & 1x1.5 sqmm (for power plug\n1) on wall through 20 mm dia rigid conduit | BI01010001010000000000000515BI0100001347 | 230 | mtr |
| 237 | 237 | S & drawing different size copper wire partly in polythine pipe embedded in wall & partly in rigid conduit pipe on wall for different power plug & SPN DB etc. b) 2x4 sq.mm & 1x2.5 sq.mm for meter connection.\n1) Embeded in wall through 19 mm dia poly pipe.\n | BI01010001010000000000000515BI0100001348 | 200 | mtr |
| 238 | 238 | S & drawing different size copper wire partly in polythine pipe embedded in wall & partly in rigid conduit pipe on wall for different power plug & SPN DB etc. b) 2x4 sq.mm & 1x2.5 sq.mm for meter connection.\n1) on wall through 20 mm dia rigid conduit\n | BI01010001010000000000000515BI0100001349 | 200 | mtr |
| 239 | 239 | S&F 250V superior type Ding Dong call bell (Anchor 8320) on HW board incl. S&F HW board. | BI01010001010000000000000515BI0100001350 | 42 | nos |
| 240 | 240 | S& F 250V 32A DPIC Main Switch on flat iron frame on wall (Havells Make) as per G.S. | BI01010001010000000000000515BI0100001351 | 42 | nos |
| 241 | 241 | S&F bulk-head fittings (Havells make) incl. S&F 6 Watt LED as per G.S. | BI01010001010000000000000515BI0100001352 | 70 | nos. |
| 242 | 242 | S & F 400wt stepped electronic regulator after board cutting connetion (Modular Step-type) . | BI01010001010000000000000515BI0100001353 | 194 | nos |
| 243 | 243 | S&F decorative bracket fittings (APPROVED MAKE) as per direction of EIC excluding lamp. | BI01010001010000000000000515BI0100001354 | 74 | nos. |
| 244 | 244 | Supply of 4ft. Long 20 watt single LEDTube Light fittings(Make-crompton LTT 8-20-865 , IGP 131 LT 8-16) | BI01010001010000000000000515BI0100001355 | 70 | nos |
| 245 | 245 | Fixing only single/twin fluorescent light fittings complete with all accessories directly on wall/ceiling/ HW round block and suitable size of MS fastener. | BI01010001010000000000000515BI0100001356 | 70 | nos |
| 246 | 246 | Supply of 90 Watt LED street light fitting (make Crompton cat no - LSTP-90-CDL) incl. | BI01010001010000000000000515BI0100001357 | 11 | do |
| 247 | 247 | Supply & fixing 40mm dia GI (ISI-M) pipe of length 1.20 mtr long KMDA type Arm bracket thouroughly welded with 100mm dia 30 cm long vertical jacket with necy. tie support incl. S/F pole cap & painting as derection of the EIC. | BI01010001010000000000000515BI0100001358 | 11 | do |
| 248 | 248 | Earthing the installation by 2” dia G.I.Pipe, 4 SWG G.I.wire,1.5” dia G.I.pipe protection with nut,bolt,washer etc as per GS. | BI01010001010000000000000515BI0100001359 | 20 | set |
| 249 | 249 | S & F of the galvaanized MS flat 25mm x 6mm earth bus bar as per GS. | BI01010001010000000000000515BI0100001360 | 30 | mtr. |
AI Tender Summary
Tender Timeline
Nov 05, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedNov 28, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 30, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender