Defence Research And Development Organisation -DRADO has published Provision Of Maintenance Services For Internal Electrical Water Supply At Iir Seekar Lab At Rci , Hyderabad. Submission Date for this Tender is 20-11-2019. Tanks and Cylinders Tenders in RCI Hyderabad Telangana. Bidders can get complete Tender details and download the document.
NAME OF THE WORK : PROVISION OF MAINTENANCE SERVICES FOR INTERNAL ELECTRICAL WATER SUPPLY AT IIR SEEKAR LAB AT RCI , HYDERABAD. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | i) Operation and Maintenance of Internal Electrical and Water Supply along with all auxillaries by deploying Electrician/ DG Operator- 2 Nos and Helpers - 1 Nos as per the detailed scope of work indicated in Annexure-I to IV, for 01 (One) shift i.e., from 09.00hrs to 19.00hrs, on all working days except Sundays by deploying 03 (Three) man power only, for the work. | item1 | 12 | month |
2 | 1.2 | Comprehensive Annual Maintenance for 2 Nos of Water coolers at IIR Seekar Building along with all auxillaries as per the detailed scope of work indicated in Annexure-I to IV | item2 | 12 | month |
3 | 1.3 | Recharge and Reconditioning of Earth pits | item3 | 50 | Nos |
4 | 1.4 | PART 'II' (DSR ITEMS)\nExecution of items of work covered under CPWD-DSR-2016\n | |||
5 | 2 | PART 'III' (NON DSR ITEMS) | |||
6 | 2.1 | Clearing the blockage of manholes of all sizes and disposing sludge as per direction of Engineer-in-Charge | item4 | 1 | Each |
7 | 2.2 | Clearing the blockage of nahani trap 1 gully trap and disposing of sludge | item5 | 1 | Nos |
8 | 2.3 | Clearing the blockage of drain pipe by roding etc.,till smooth flow of SWG/ RCC pipes of 100mm/ 150mm dia including disposal of sludge | item6 | 1 | Nos |
9 | 2.4 | Removing/taking away settled solid sludge from manhole and disposing the same to a distance exceeding 100m and not exceeding 250m and burning the same (only solid sludge will be measured semi solid liquid sludge shall not be measured | item7 | 1 | Lot |
10 | 3 | Removing 1 taking away sludge from septic tank and disposing the same to a distance exceeding 100m and not exceeding 250m and burning the same as per direction given by Engg. In charge. | |||
11 | 3.1 | 25 Users | item8 | 1 | Each |
12 | 3.2 | 50 Users | item9 | 1 | Each |
13 | 3.3 | Repairs to existing wooden Flush / Panel door shutter after removing hinges and refixing after necessary easing repairs & welding of MS butt hinges to frame etc. all complete | item10 | 1 | Sqm |
14 | 3.4 | Providing brick masonary with available bricks obtained in super structure with cement mortar 1:6 (1 Cement:6 Coarse sand) including additional bricks required if any, curing and scaffolding etc., all complete | item11 | 1 | Cum |
15 | 3.5 | Removing damaged plaster and re doing 18mm water proofing plaster in 2 layer as per standard specification. | item12 | 1 | Sqm |
16 | 3.6 | a) Providing and applying polymer based admixture mixed with cement for waterproofing as per manufacturers specification for external plastered surface at all heights including scaffolding (fosroc of equivalent make) etc all complete including testing | item13 | 1 | Sqm |
17 | 3.7 | b) Providing and applying waterproofing treatment by opening the wider cracks and sealing the cracks, primering the surface with SBR based primer and applying two coats of special resin based polymer modified UV resistance white water based liquid membrane including laying of fibre mesh over the cracks when the first coat is still green etc., complete | item14 | 1 | Sqm |
18 | 3.8 | c) Providing waterproofing for the terrace by liquid membrane treatment method by primering the surface with SBR primer applying two coats of polymer modified bituminous water based liquid membrane including laying of fiber mesh and finally applying two coats of special resin based polymer modified UV resistance white water based liquid membrane etc., complete | item15 | 1 | Nos |
19 | 3.9 | Supplying and fixing 4mm thick pin headed glass with glass putty and glazing pins including cleaning the surface at all heights etc all complete | item16 | 1 | Lot |
20 | 4 | Supplying and fixing 4mm thick plain glass with glass putty and glazing pins including cleaning the surface at all heights etc all complete | item17 | 1 | Nos |
21 | 4.1 | Supplying and fixing glass putty with glazing pins including cleaning the surface etc all complete | item18 | 1 | Nos |
22 | 4.2 | Providing and fixing galvanized wire guage of average width of aperture 1.4mm with wire of dia 0.63mm for doors and windows with necessary teak beading if required all around complete | item19 | 1 | Nos |
23 | 4.3 | Repairs to existing rolling shutter including removing, staraighting strips,refixing, greasing of side chanel, replacing ball bearing if required etc, complete. | |||
24 | 4.4 | a) up to 3.00m height | item20 | 1 | Each. |
25 | 4.5 | b) above 3.00m height | item21 | 1 | Each. |
26 | 4.6 | c) above 3.00m height motor operated | item22 | 1 | Each. |
27 | 4.7 | Removing, making good & refixing existing compound wall grills 800mm high at all heights including scaffolding etc, complete | item23 | 1 | Each. |
28 | 4.8 | Providing and fixing in position precast reinforced cement concrete Slabs including the cost of required centring, shuttering, finishing with 6 mm thick cement plaster 1:3 (1 Cement : 3 Fine sand) on exposed surfaces but excluding the cost of reinforcement with 1 : 2 : 4 (1 Cement : 2 Coarse sand : 4 graded stone aggregated 20 mm nominal size). | item24 | 1 | Cum |
29 | 4.9 | Providing and fixing approved quality bright finished brass cup board or ward robe lock including necessary screw etc, compete. | item25 | 1 | Each |
30 | 5 | Dismentaling & construction of brick masonary manhole with available bricks in cement morter 1:4 (1 cement : 4 coarse sand ), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation with PCC 1:4:8 ( 1 cement 4 coarse sand : 8 greaded tone aggregate 40 mm nominal size ), inside plastering 15 mm thick with cement morter coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) complete including additional bricks if any required & cleaning debries from site. | |||
31 | 5.1 | a) inside size 60 x 60 cm and 60 cm deep excluding C.I Cover | item26 | 1 | Each. |
32 | 5.2 | b) inside size 45 x 45 cm and 60 cm deep excluding C.I Cover | item27 | 1 | Each. |
33 | 5.3 | c) inside size 90 x 80 cm and 60 cm deep excluding C.I Cover | item28 | 1 | Each. |
34 | 5.4 | Removing, repairing and fixing of steel work welded in built up sections I framed work including cutting hosting, fixing in position and applying a priming coat of approved steel primer using structural etc. as required.\n\na) In frames, guard bar, railings, & windows.\n | item29 | 1 | Kg |
35 | 5.5 | Providing and laying reinforcement for RCC work including straighting, cutting,bending, placing in position and binding all comlete.\n\na) Tor steel \n | item30 | 1 | Kg |
36 | 5.6 | Removing plaster, filing gap with screeed, fixing plaster mesh re-doinh plaster to match with existing surface including making good. | item31 | 1 | Sqm |
37 | 5.7 | Removing the existing aluminium door & window shutter repairing and refixing easing, smooth opening and closing. | item32 | 1 | Sqm |
38 | 5.8 | Providing random rubble masonry with old stone (obtained from dismantling) in super structure above plinth with cement mortar 1:6(1 cement : 6 coarse sand) including cast of bond stone - two Each for every one sqm surface area curing and scaffolding etc all complete. | item33 | 1 | Cum |
39 | 5.9 | Removing,repairing, refixing in position old steel work welded in built of section gate including provding two coats of synthetic enamel paint over it and fixing in PCC bed bloc of 1:2:4 mix of size at all heights complete. | item34 | 1 | Kg |
40 | 6 | Providing and laying concrete screed average 6mm to 10mm thick in cement mortar 1:1 mixed with polymer hardening compound of pedilite or equivalent damaged surface of concrete road/ hard standing including necessary cleaning finishing the surface even complete. | item35 | 1 | Sqm |
41 | 6.1 | Desilting of drains upto 1 mtr. Deep, disposal and spreading the same upto a lead of 100 mtrs. | item36 | 1 | Rmt |
42 | 6.2 | Removing existing damaged glazed tiles in dado and redoing with 2mm cement plaster 1:6 (1 cement : 6 coarse sand) to match with existing surface: | item37 | 1 | Sqm |
43 | 6.3 | Removing and repairing hydraulic door closers, making, functional and fixing. | item38 | 1 | Each |
44 | 6.4 | PART 'IV' (SCHEDULE OF CREDIT) | |||
45 | 6.5 | Wooden door shutter of any size, specification and thickness including all fixtures/fitting complete. | item39 | 1 | Each |
46 | 6.6 | Aluminium scarp, like hardware items, channel and other fittings, starps. | item40 | 1 | Kg |
47 | 6.7 | PVC Flush tank low level. | item41 | 1 | Each |
48 | 6.8 | MS Door chowkhat with holdfasts (any size) | item42 | 1 | Each |
49 | 6.9 | Stone boulders (As per stock measurement after Cum allowing 50% for voids | item43 | 1 | Cum |
50 | 7 | LDPE water storage tanks, any capacity | item44 | 1 | Per.Ltr |
51 | 7.1 | C.P Brass Scrap items. | item45 | 1 | Kg |
52 | 7.2 | Scrap hydraulic door closer | item46 | 1 | Each |
53 | 7.3 | PART 'V' (SUPPLY OF ELECTRICAL SPARES) | |||
54 | 7.4 | 63 Amps 35KA TP MCCB | item47 | 1 | Each. |
55 | 7.5 | 100 Amps 35KA TP MCCB | item48 | 1 | Each. |
56 | 7.6 | 125 Amps 35KA TP MCCB | item49 | 1 | Each. |
57 | 7.7 | 250 Amps 35KA TP MCCB | item50 | 1 | Each. |
58 | 7.8 | 400 Amps 50KA TP MCCB | item51 | 1 | Each. |
59 | 7.9 | 638 Amps 50KA TP MCCB | item52 | 1 | Each. |
60 | 8 | 800 Amps 50KA TP MCCB | item53 | 1 | Each. |
61 | 8.1 | Digital Ammeter 96x96 | item54 | 1 | Each. |
62 | 8.2 | Digital voltmeter 96x96 | item55 | 1 | Each. |
63 | 8.3 | Panel indication lamp(R-Y-B) | item56 | 1 | Each. |
64 | 8.4 | Street Light Timer | item57 | 1 | Each. |
65 | 8.5 | Contactor 40Amp(L&T) (Snider) | item58 | 1 | Each. |
66 | 8.6 | 63 Amps ELCB 100MAmps TPN | item59 | 1 | Each. |
67 | 8.7 | 40 Amps ELCB 100MAmps TPN | item60 | 1 | Each. |
68 | 8.8 | 63 Amps MCB TPN | item61 | 1 | Each. |
69 | 8.9 | 40 Amps MCB TPN | item62 | 1 | Each. |
70 | 9 | 32 Amps MCB TPN | item63 | 1 | Each. |
71 | 9.1 | 25 Amps SP MCB | item64 | 1 | Each. |
72 | 9.2 | 16 Amps SP MCB | item65 | 1 | Each. |
73 | 9.3 | 10 Amps SP MCB | item66 | 1 | Each. |
74 | 9.4 | 25 Amps 3pin Metal clad Scoket | item67 | 1 | Each. |
75 | 9.5 | 25 Amps 3pin Metal clad Top | item68 | 1 | Each. |
76 | 9.6 | 32 Amps 5pin Metal clad Scoket | item69 | 1 | Each. |
77 | 9.7 | 32 Amps 5pin Metal clad Top | item70 | 1 | Each. |
78 | 9.8 | 63 Amps 5pin Metal clad Scoket | item71 | 1 | Each. |
79 | 9.9 | 63 Amps 5pin Metal clad Top | item72 | 1 | Each. |
80 | 10 | 40/36 Watts florecentTubes | item73 | 1 | Each. |
81 | 10.1 | 14 Watts florecentTubes | item74 | 1 | Each. |
82 | 10.2 | 13 Watts 2pin PL Lamp | item75 | 1 | Each. |
83 | 10.3 | 11W 2pin PL Lamp | item76 | 1 | Each. |
84 | 10.4 | 9 W 2pin PL Lamp | item77 | 1 | Each. |
85 | 10.5 | 13 Watts CFL Lamp | item78 | 1 | Each. |
86 | 10.6 | 11W CFLamp | item79 | 1 | Each. |
87 | 10.7 | 9 W CFL Lamp | item80 | 1 | Each. |
88 | 10.8 | 125W HPMV Lamp | item81 | 1 | Each. |
89 | 10.9 | 80W HPMV Lamp | item82 | 1 | Each. |
90 | 11 | 150W SV Lamp | item83 | 1 | Each. |
91 | 11.1 | 40/36W Electronic choke | item84 | 1 | Each. |
92 | 11.2 | 40/36W Copper choke | item85 | 1 | Each. |
93 | 11.3 | 4 x 14W Electronic choke | item86 | 1 | Each. |
94 | 11.4 | 13W Electronic choke | item87 | 1 | Each. |
95 | 11.5 | 11W Electronic choke | item88 | 1 | Each. |
96 | 11.6 | 13W Copper choke | item89 | 1 | Each. |
97 | 11.7 | 11W Copper choke | item90 | 1 | Each. |
98 | 11.8 | Electronic Transformer :\n50W Lamp Voltage 230/12V\nShort Circuit and Over Voltage protection | item91 | 1 | Each. |
99 | 11.9 | 6Amps one model Switches(Modulars) | item92 | 1 | Each. |
100 | 12 | 16Amps one model Switches with indicator (Modulars) | item93 | 1 | Each. |
101 | 12.1 | 5Amps 5pin Sockets | item94 | 1 | Each. |
102 | 12.2 | 16Amps 3model 5pin Sockets | item95 | 1 | Each. |
103 | 12.3 | 16Amps 2model 5pin Sockets | item96 | 1 | Each. |
104 | 12.4 | Telephone Scoket RJ11 | item97 | 1 | Each. |
105 | 12.5 | Lan Scoket RJ45 | item98 | 1 | Each. |
106 | 12.6 | One Pair Telephone Cable | item99 | 1 | Rmt |
107 | 12.7 | Electronic Fan Regulator 2 Model (Step type) | item100 | 1 | Each. |
108 | 12.8 | 1 Model plate | item101 | 1 | Each. |
109 | 12.9 | 2 Model plate | item102 | 1 | Each. |
110 | 13 | 3 Model plate | item103 | 1 | Each. |
111 | 13.1 | 4 Model plate | item104 | 1 | Each. |
112 | 13.2 | 6 Model plate | item105 | 1 | Each. |
113 | 13.3 | 8 Model plate | item106 | 1 | Each. |
114 | 13.4 | 4 Model Surface Box | item107 | 1 | Each. |
115 | 13.5 | 3 Model Surface Box | item108 | 1 | Each. |
116 | 13.6 | 105 x 50MM Legrand Tranking with all accessories | item109 | 1 | Rmt. |
117 | 13.7 | 32 x 12.5MM Legrand Tranking with all accessories | item110 | 1 | Rmt. |
118 | 13.8 | 25MM Casing & Caping | item111 | 1 | Rmt. |
119 | 13.9 | 1.5 Sqmm FRLS Copper Wire (90m Coil) | item112 | 1 | Coil. |
120 | 14 | 2.5 Sqmm FRLS Copper Wire (90m Coil) | item113 | 1 | Coil. |
121 | 14.1 | 4 Sqmm FRLS Copper Wire (90m Coil) | item114 | 1 | Coil. |
122 | 14.2 | 6 Sqmm FRLS Copper Wire (90m Coil) | item115 | 1 | Coil. |
123 | 14.3 | 4 Core x 4 sqmm copper flexiwell cable | item116 | 1 | Rmt. |
124 | 14.4 | 1200MM Sweep Ceiling Fan | item117 | 1 | Each. |
125 | 14.5 | 305 Sweep Exhaust Fan | item118 | 1 | Each. |
126 | 14.6 | NS 4Amps Fuse Link | item119 | 1 | Each. |
127 | 14.7 | 20A 3 Pin Plug Top | item120 | 1 | Each. |
128 | 14.8 | 32A 5 Pin Plug Top | item121 | 1 | Each. |
129 | 14.9 | 63A 5 Pin Plug Top | item122 | 1 | Each. |
130 | 15 | 125A 5 Pin Plug Top | item123 | 1 | Each. |
131 | 15.1 | 125A 5 Pin Scoket | item124 | 1 | Each. |
132 | 15.2 | CAT 6 Cable | item125 | 1 | Rmt. |
133 | 15.3 | PART 'VI' (SUPPLY OF WATER SUPPLY ITEMS) | |||
134 | 15.4 | C.P. Brass bib-cock 15mm dia | item126 | 1 | Each. |
135 | 15.5 | C.P. Brass bib-cock 20mm dia | item127 | 1 | Each. |
136 | 15.6 | C.P. Brass stop-cock 20mm dia | item128 | 1 | Each. |
137 | 15.7 | C.P. Brass wash basin cock 15mm dia | item129 | 1 | Each. |
138 | 15.8 | C.P. Brass wash basin cock 20mm dia | item130 | 1 | Each. |
139 | 15.9 | (Note: Quoted amount should not include EPF, ESI, Bonus & GST element on EPF, ESI and Bonus amounts). |