| 1 | 1 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables & foundation of poles , stay assembly and getting out in any type of soil complete all as specified and directed. | 1 | 220 | CUM |
|---|
| 2 | 2 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm each layer ,complete all as specified and directed. | 3 | 138 | CUM |
|---|
| 3 | 3 | Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point ,complete all as specified and directed. | 4 | 82 | CUM |
|---|
| 4 | 4 | M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable and gentally hand ramming and consolidation etc. complete all as specified and directed. Note :- Thickness of sand shall be measured 18 cm thick after punning. | 5 | 65 | CUM |
|---|
| 5 | 5 | M & L for old size sub class ‘B’ bricks, laid in trenches as cable covers / protection complete all as specified and directed. | 6 | 7.17 | PER 1000 Nos |
|---|
| 6 | 6 | Supply and erecting steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts & washers as per IS 2713 (Part-II ) 1980 made out of mild steel tubing, type 410 SP-31 (9.0 metres long) including marking pole No. on pole complete all as specified and shown on drawings and including the following :- | 10 | 12 | EACH |
|---|
| 7 | 6.01 | (a) Excavation in post holes in any types of soil, return filling, well ramming and disposal of surplus soil to a distance not exceeding 50 m from the starting points. | | | |
|---|
| 8 | 6.02 | (b) PCC (1:3:6) type C2 using 40 mm graded stone aggregate as in foundation. | | | |
|---|
| 9 | 6.03 | (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of size 450x450x600 mm including necessary from work and finish the surface even and smooth without using extra cement. | | | |
|---|
| 10 | 6.04 | (d) Painting of poles with one coat of red oxide primer and two coat of aluminum paint ( one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion. | | | |
|---|
| 11 | 6.05 | (e) The portion above coping shall be painted in alternative bands of black and white colour starting with white colour (each band of 30 cm wide) by two coats of super enameled paint upto 1.5 m height | | | |
|---|
| 12 | 7 | Supply and stringing ACSR conductor of any size from LT over head line as directed including fixing to insulators with proper size of binding wire complete all as specified and directed. | 11 | 4 | QTL |
|---|
| 13 | 8 | Dismentling and taking out broken serviceable ACSR conductor from existing poles / dismantled poles / pole structures of any size from LT over head line as directed and keep in safe custody for re-use if found serviseable complete all as specified and directed. | 12 | 6 | QTL |
|---|
| 14 | 9 | Fixing only and stringing ACSR conductor of any size to LT over head line as directe including fixing to insulators with proper size of binding wire complete all as specified and directed. NOTE :- ACSR conductor obtained under item No-12 shall be re-used. | 13 | 2 | QTL |
|---|
| 15 | 10 | Dismentling of old unserviceable earth wire or distributor span, cardle ground etc. complete all as specified and directed. | 15 | 1 | QTL |
|---|
| 16 | 11 | Supply and straining GI earthe wire of 4 MM dia on over head line 9 M pole maintaing proper sag as per IE rule complete all as specified and directed. | 16 | 1 | QTL |
|---|
| 17 | 12 | Supply and Fixing in repair Cardles, Hexagonal / Rectangular, fabricated with galvanised steel wire 4 MM dia complete all as specified and directed. | 17 | 2 | QTL |
|---|
| 18 | 13 | M & L for Restraining of LT over head line single ACSR conductor comprising of any size of conductor aluminium/copper/GI after opening binding wire from insulators and replace binding wire and achieved permissible sag limit of over head line conductor complete all as directed and specified.\nNote - Rate quoted by the contractor shall be deemed to include for cutting/trimming of tree branches wherever touching the over headline around one metre clear of over head line and removing trimmed branches as directed. Nothing extra shall be paid on this account. | 14 | 8000 | RM |
|---|
| 19 | 14 | M & L for stay assembly comprising of 7/10 SWG galvanised stay stranded wire of required length fixed to pole with and including flat iron clamp, bolts, nuts and washers, galvanised 14mm dia, 400mm long stay bow with 20 mm dia 215 cm long stay rod with threaded ends, GI nut & washers GI stay plate 300 x 300 x 6mm thick plate 2 Nos thimble, MS clamp made out of 50 x 6 mm flat iron, loop insulator 90mm x 140mm dia hole, 25mm porcelain complete all as specified and shown in electrical plate No 1 of SSR Part I (2010), including cost of the following :- | 19 | 10 | EACH SET |
|---|
| 20 | 14.01 | (a) Excavation in post holes in any type of soil, returning filling and well ramming including disposal of surplus soil to distance n. exc 50mtrs from starting points. | | | |
|---|
| 21 | 14.02 | (b) PCC (1:3:6) type C2, using 40mm graded stone aggregated as in foundation. | | | |
|---|
| 22 | 15 | M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminium paint over a coat of red oxide primer, complete all as directed including dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as specified and directed. | 21 | 2 | QTL |
|---|
| 23 | 16 | Dismantling and taking out servicable cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as specified and directed. | 22 | 3 | QTL |
|---|
| 24 | 17 | Fixing only cross arms, bracings, supports, clamps and back plates of any size to LT over head line as directe including fixing accessories complete with suitable size complete all as specified and directed.\nNOTE :- Cross arms, bracings, supports, clamps and back plates are obtained under item No-15 shall be re-used. | 23 | 1 | QTL |
|---|
| 25 | 18 | S&F Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for LT size 20 X 15 Cm fix in repairs complete all as specified and directed. | 24 | 25 | EACH |
|---|
| 26 | 19 | Dismantling and taking out servicable insulators of any size and any type from existing poles / dismantled poles / pole structures complete all as specified and directed. | 25 | 155 | EACH |
|---|
| 27 | 20 | Fixing only insulator of any size and any type to LT over head line as directe including fixing accessories complete with suitable sizecomplete all as specified and directed.\nNOTE :- Insulators are obtained under item No. 19 shall be re-used | 26 | 60 | EACH |
|---|
| 28 | 21 | S & F Pin type, porcelain, vitreous, white, brown or green insulator, 100mm height, 65 mm dia for 1100 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut complete all as specified and directed. | 27 | 50 | EACH |
|---|
| 29 | 22 | M&L for Shackle type insulator from LT overhead line and S&F new Shackle type, porcelain, vitreous, white, brown or green insulators 100mm dia and 115 mm height for working pressure 1100 volts including galvanised mild steel strap 31 x 3mm size, washers, 14mm dia insulator bolts, washers & nuts complete all as specified and directed. | 28 | 45 | EACH |
|---|
| 30 | 23 | Cutting & trimming tree branches along LT over head lines after taking all precautions while working on lines such as taking shut down , safety equipments etc . and clearing of area and removing the same from site to a distance not exceeding 50 mtr complete all as specified and directed. \nNOTE: Contractor shall be responsible for cutting of grith of tree branches upto 50 mm dia with the grith of tree branches above 50 mm dia & rate shall be deemed to be unit quated rate. | 30 | 800 | Each branch |
|---|
| 31 | 24 | Removing of old Un used /Damage LT PCC / Steel pole PCC including excavation retureing filling & breaking of PCC foundation & deposited to complete all as directed as directed. | 48 | 12 | EACH |
|---|
| 32 | 25 | Cutting of grass, at sub stations / EM Istallations and surrounding areas etc complete or when and where directed and removing the same from site to a distance not exceeding 50 mtr complete and spreading of bleaching powdwe at the rate 1 kg/1o sq meter for stop the abnomal grouth of grass complete all as specified and directed. | 31 | 1000 | Sqm |
|---|
| 33 | 26 | S & F in repair for LT line PVC Spacers spiral type for the following :- | 32 | | |
|---|
| 34 | 26.01 | Spacer for two wire | 33 | 60 | EACH |
|---|
| 35 | 26.02 | Spacer for three wire | 34 | 110 | EACH |
|---|
| 36 | 26.03 | Spacer for four wire | 35 | 250 | EACH |
|---|
| 37 | 26.04 | Spacer for five wire | 36 | 25 | EACH |
|---|
| 38 | 27 | M&L for Synthetic insulating rubber mat of size 2 m x 1m x 25 mm with ISI mark suitable for 11 KV rating in red colour complete all as specified and directed. | 37 | 4 | EACH |
|---|
| 39 | 28 | Supply and fixing in repair four pole changeover switch onload type with side handle 415 volt AC 50 Hz 320 amps in sheet steel enclosure and Conforming to IS / IEC : 60947 -1&3 complete all as specified & directed. \nMake - L&T/HPL/Havells. | 38 | 1 | EACH |
|---|
| 40 | 29 | Supply and fixing in repair four pole changeover switch disconector with advance neutral 415 volt 50 Hz 200 amps in sheet steel enclosure and Conforming to IS / IEC : 60947 - 3 complete all as specified & directed. \nMake - L & T Cat No -CO22000OSOO Or equivalent model of Siemens/Schneider. | 39 | 2 | EACH |
|---|
| 41 | 30 | Supply and fixing in repair four pole changeover switch disconector with advance neutral 415 volt 50 Hz 100 amps in sheet steel enclosure and Conforming to IS / IEC : 60947 - 3 complete all as specified & directed. \nMake - L & T Cat No -CO11000OSOO Or equivalent model of Siemens/Schneider. | 40 | 3 | EACH |
|---|
| 42 | 31 | Supply and fixing in repair four pole changeover switch disconector with advance neutral 415 volt 50 Hz 200 amps in open execution and Conforming to IS / IEC : 60947 - 3 complete all as spefied & directed. \nMake - L & T Cat No -CO22000OOOA Or equivalent model of Siemens/Schneider. | 41 | 1 | EACH |
|---|
| 43 | 32 | Supply and fixing in repair four pole changeover switch disconector with advance neutral 415 volt 50 Hz 100 amps in open execution and Conforming to IS / IEC : 60947 - 3 complete all as specified & directed. \nMake - L & T, Cat No -CO11000OOOO Or equivalent model of Siemens/Schneider. | 42 | 2 | EACH |
|---|
| 44 | 33 | Supply and fixing in repair switch fuse disconector TPN 415 volt 50 Hz 200 amps in sheet metal enclosure and Conforming to IS / IEC : 60947-3 complete all as specified & directed. \nMake - L & T, Cat no -SK90488 or equivalent model of Siemens/Schneider. | 43 | 2 | EACH |
|---|
| 45 | 34 | Supply and fixing in repair switch fuse disconector TPN 415 volt 50 Hz 100 amps in sheet metal enclosure and Conforming to IS / IEC : 60947-3 complete all as specified & directed. \nMake - L & T, Cat No -SK90485 or equivalent model of Siemens/Schneider. | 44 | 2 | EACH |
|---|
| 46 | 35 | M & L for Painting of steel pole with cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia yellow circle & marking six black & four yellow bends width 15 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable height complete all as specified and directed. | 45 | 150 | EACH |
|---|
| 47 | 36 | M & L for Earthing to OH /Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI wire 4 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES Schedule part-I 2009, GI earth lead wire protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.\nNote : Main earth lead beyond 7.5 meter shall measured and paid saperatly. | 49 | 6 | EACH |
|---|
| 48 | 37 | Ditto all as per above item No - 42 but main earth lead 32 x 6 mm galvanised iron strip complete all as specified and directed. | 50 | 6 | EACH |
|---|
| 49 | 38 | Supply and fixing in repair for Earth continuity conductor or main earthing lead of 4 mm dia galvanized iron or steel wire, buried in ground or fixed to wall complete all as specified and directed. | 51 | 100 | RM |
|---|
| 50 | 39 | Supply and fixing in repair for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall complete all as specified and directed. | 52 | 30 | RM |
|---|
| 51 | 40 | Taking up underground unservicable cable of any size from existing trench including bricks, etc and removing of materials from work site complete all as specified and directed. | 53 | 1270 | RM |
|---|
| 52 | 41 | Supply, laying & testing for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 150 Sqmm nominal cross section x 3.5 core complete all as specified and directed. | 54 | 100 | RM |
|---|
| 53 | 42 | Ditto all as per item No. 41 but Size 95 Sqmm X 3.5 core | 55 | 200 | RM |
|---|
| 54 | 43 | Ditto all as per item No. 41 but Size 50 Sqmm X 3.5 core | 56 | 250 | RM |
|---|
| 55 | 44 | Ditto all as per item No. 41 but Size 25 Sqmm X 3.5 core | 57 | 200 | RM |
|---|
| 56 | 45 | Ditto all as per item No. 41 but Size 16 Sqmm X 4 core | 58 | 200 | RM |
|---|
| 57 | 46 | Ditto all as per item No. 41 but Size 10 Sqmm X 2 core | 59 | 130 | RM |
|---|
| 58 | 47 | Laying or fixing or passing in trenches / on pole / through pipes etc only including connection and testing of XLPE insulated , armoured heavy duty electric power cable with stranded aluminium conductor opf any size complete all as specified and directed.\nNOTE :- Old Cable shall be used obtained from under item No. 40. | 60 | 200 | RM |
|---|
| 59 | 48 | Supply and fixing in repair PVC insulated, stranded aluminium conductor served with inner sheathing PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm dia GI suspension wire of wire 10 Sqmm 2 core,complete all as specified and directed.\n | 62 | 500 | RM |
|---|
| 60 | 49 | Supply and fixing in repair GI tubing, light grade, 40 mm bore with all fitting laid in trenches / pole / wall for protection of cables complete all as specified and directed. | 76 | 30 | RM |
|---|
| 61 | 50 | Supply and fixing in repair GI tubing, light grade, 80 mm bore with all fitting laid in trenches / pole / wall for protection of cables complete all as specified and directed. | 77 | 10 | RM |
|---|