| 1 | 1 | Providing and applying tack coat with catonic bitumen emulsion (RS-1) using emulsion pressure distributor on the prepared bituminous/ granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications. | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1.01 | (i) @ 0.25 kg per sqm (normal bituminous surfaces) | BI01010001010000000000000515BI0100001113 | 40880 | Sqm |
|---|
| 3 | 2 | Bituminous Concrete Providing and laying bituminous concrete using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per clause 507 of specification.Using Batch mix Plant of appropriate capacity and Paver Finisher Hydraustatic with Sensor control. (iv) for Grading-II ( 30-45 mm thickness ) with 60/70 bitumen(VG-30) | BI01010001010000000000000515BI0100001114 | 1496 | Cum |
|---|
| 4 | 3 | Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100 kN static weight to meet requirement as per relevant clause of 400. | BI01010001010000000000000515BI0100001115 | | |
|---|
| 5 | 3.01 | B Hard Shoulders (CBR value >12) | BI01010001010000000000000515BI0100001116 | 1800 | Cum |
|---|
| 6 | 4 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes all complete as per clause 803 of specifications. | BI01010001010000000000000515BI0100001117 | 1717.8 | Sqm |
|---|
| 7 | 5 | Road Delineators\nSupplying and installation of delineators (road way indicatorsas per MORT&H Clause 806. The structure shall be made in roll forming process having height of 80-100 cm above the ground level. Width not less than 100 mm below the ground while being installed buried or pressed in to the ground in confirmation with IRC:79:1981. are as directed by the Engineer painted black with powder coat of minimum 40 microns thickness for protection against corrosion.on top of which Type XI retro reflective sheeting shall be pasted on both sides complying to IRC:79:1981.The delineator should consist of minimum retro reflective unit exposted area of 330 cm2 white color. Full cube corner micro prismatic non-metalic retro reflective sheeting on each side conforming with IRC:67:2012 and meeting the coefficient of reto reflection values as per ASTM D 4956 Type XI table specification. The delineator shall have grooves across the length to make the reflective sheet vandal-proof. | BI01010001010000000000000515BI0100001118 | 480 | Each |
|---|
| 8 | 6 | Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2010 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide clause 801.3.3 fixed over Aluminium composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminium with overall thickness of 4mm and aluminium skin of thickness 0.3 on both side, the ACM shall conform to Table 800-1 of specification and High Intensity Micro Prismatck Grade Sheeting shall conform to Table 800-3 of specification. The printing on the high intensity grade sheeting shall conform to Clause 801.3.7 with water based latex optimized transparent ink as specified by the sheeting manufacturer, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to ground by means of properly designed foundation with M15 grade concrete 450x450x600mm The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts | BI01010001010000000000000515BI0100001119 | | |
|---|
| 9 | 6.01 | i) 90 cm equilateral triangle | BI01010001010000000000000515BI0100001120 | 10 | Each |
|---|
| 10 | 6.02 | ii) 60 cm equilateral triangle | BI01010001010000000000000515BI0100001121 | 10 | Each |
|---|
| 11 | 6.03 | iii) 60 cm circular | BI01010001010000000000000515BI0100001122 | 10 | Each |
|---|
| 12 | 6.04 | iv) 60 cm x 45 cm rectangular | BI01010001010000000000000515BI0100001123 | 10 | Each |
|---|
| 13 | 6.05 | v) 60 cm x 60 cm square | BI01010001010000000000000515BI0100001124 | 10 | Each |
|---|
| 14 | 7 | Direction and Place Identification signs with size more than 0.9 sqm size board. Providing and fixing directional informatory and place indentification retro-reflectorized sign as per IRC:67:2012 made of high intencity Micro-Prismatic Grade cube corner sheeting (Type XI)vide 801.3.4.3 of MORT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminium with overallthickness of 4mm and aluminium skin of thickness 0.3 on both side. The ACM shall conform to Table 6.1 of IRC:67:2012 & table 800-1 of MORT&H specification and high Intensity Micro Prismatic Grade cube corner sheeting shall conform to shall conform to table 6.9 of IRC :67:2012 & TABLE 800-6 OF MORT&H specification In line with clause 6.8 of of IRC :67:2012 & clause 801.3.7 of MORT&H for the directional informatory. Place indentification and other boards. The massage (legends,letters;numbers etc) and borders shall be cut-out form durable transparent overlay film or cut-out from the same reflective sheeting only. Cut-outs shall be from durable transparent overlay materials as specified by the sheeting manufacturer and shall be bonded with the sheeting in the manner specifird by the manufacturer and should be supported on MS sign post of size 75mmX75mmX6mm fixed to ground by means of property designed foundation of dimension 450X450X600mm with M15 grade concrete the ACM sheet shall be fixed to the post with four minimum four number breakaway bolts & supported with a backn support frame of 25mmX25mmX3mm angle 10 years warranty for Retro-Reflective Sheeting from the original sheeting manufacturer as per clause 6.9 of IRC:67:2012 & a certified copy of 3 years outdoor exposure report from an independent test labe as per clause 6.7 of IRC:67:2012 for the product offered shall be submitted by the contractor. | BI01010001010000000000000515BI0100001125 | 8.64 | Sqm |
|---|
| 15 | 8 | Road Markers/Road Stud with Lense Reflector Providing and fixing single mould twin shanked molded Road Markers/Road Stud made of poly carbonate or ABS body & shall support a load of 13635kg.Tested in accordance to ASTM D 4280 & complying to specifications of section -5 of IRC 35-2015 & clause 804 of MORT&H. As per clause 804.2.2 of MORT&H and section-5 IRC 35-2015.The reflecting panels shall consist of number of lenses containing single or dual prismatic internal reflection of the light entering the lens face. The slope or retro reflective surface should be 35+/-5degree to base . The reflective marker shall be fixed to the road surface using the epoxy/adhesives & the procedure recommended by the manufacturer. No nails shall be used to affix the markers so that the do not pose safety hazard on the road. The contractor shall submit a two year replacement warranty for satisfactory filled performance i/c stipulated retro-reflectance of the reflecting panel. | BI01010001010000000000000515BI0100001126 | 2880 | Each |
|---|