Tender For Electrical Works Supply And Erection At Dhm-Design, engineering, manufacture, shop testing, supply, packing and forwarding, transportation, delivery at storage and from storage to site of following :415 V, 200 A, 30KA (1 Sec.) MOVDB - 101 Double front type ( As per Drg No. MEC/23U7/05/E9/006/1081A, SHEET 2 OF 8) Indoor LT MOV Distribution Board, Design, engineering, manufacture, shop testing, supply, packing and forwarding, transportation, delivery at storage and from storage to site of following :415 V, 100 A, 30KA (1 Sec.) MOVDB-102 Double front type ( As per Drg No. MEC/23U7/05/E9/006/1081A, SHEET 2 OF 8) Indoor LT MOV Distribution Board, design, engineering, manufacture, shop testing, supply, packing and forwarding, transportation, delivery at storage and from storage to site of following :415 V, 30 KA single front type indoor LT Power Distribution Board (As per Drg. No.MEC/23U7/05/E9/E/006/1081 sheet 5 of 8), Design, engineering, manufacture, shop testing, supply, packing and forwarding, transportation, delivery at storage and from storage to site of following :40 KVA, 230 V Single Phase, 50HZ, dual redundant industrial type, UPS system suitable for input Power supply voltage of 415 V, TPN, +/-10%, output 230 V +/-1% , AC with solid state voltage stabilizer for bypass supply, ACDB and 30 mins. battery back-up 45 KVAH minimum (Battery type Ni-Cd, C-5 rating and Medium plate thickness ) with including all interconnecting cables among UPS, Rectifier, battery stand, ACDB/DCDB etc.(50 mtr shall be considered between battery bank and UPS panel.30 mtr cable shall be considered between ACDB/DCDB and UPS panel.), Design, engineering, manufacture, shop testing, supply, packing and forwarding, transportation, delivery at storage and from storage to site of following :2.0 KVA, 230 V Single Phase, 50HZ, dual redundant industrial type, UPS system suitable for input Power supply voltage of 415 V, TPN, +/-10%, output 230 V +/-1% , AC with solid state voltage stabilizer for bypass supply, ACDB and 4 hrs. battery back-up 16.2 KVAH minimum (Battery type Ni-Cd, C-5 rating and Medium plate thickness ) with including all interconnecting cables among UPS, Rectifier, battery stand, ACDB/DCDB etc.(50 mtr shall be considered between battery bank and UPS panel.30 mtr cable shall be considered between ACDB/DCDB and UPS panel.), Design, engineering, manufacture, shop testing, Supply of Weather Proof Lighting Panel consisting of 32A FP RCCB as incomer and 8 nos. 6 A MCB DP and 3Nos. 12A DP MCBs out goings complete with indication lamp, timer and contactor etc (LDB-6)