Kiifb Electrification For Sub Registrar Office At Chelanuur In Kozhikode Districtdapuram In Kozhikode District Electrification
Tender Value
5.14 Lakhs
Estimated cost
Bid Submission
11 Nov 2019
0 days left
EMD
12870
Bank guarantee accepted
Document Fee
1220
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
vyttila → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Kiifb Electrification For Sub Registrar Office At Chelanuur In Kozhikode Districtdapuram In Kozhikode District Electrification
BOQ
| Work Name:Construction of Sub Registrar's Office, Chelannur - Estimate for electrification | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Estimate | BI01010001010000000000000515BI0100001113 | ||
| 2 | 2 | od104544/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | BI01010001010000000000000515BI0100001114 | 41 | point |
| 3 | 3 | od104546/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories) Twin Control light point with 6A, plate ceiling rose - Short point | BI01010001010000000000000515BI0100001115 | 1 | point |
| 4 | 4 | od104548/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls,fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single control light point without ceiling rose - Short point | BI01010001010000000000000515BI0100001116 | 20 | point |
| 5 | 5 | od104550/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point | BI01010001010000000000000515BI0100001117 | 19 | point |
| 6 | 6 | od104552/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point | BI01010001010000000000000515BI0100001118 | 2 | point |
| 7 | 7 | od104554/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points | BI01010001010000000000000515BI0100001119 | 12 | each |
| 8 | 8 | od104556/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.5 sqmm green coloured FR wire,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Independent plug - Short point | BI01010001010000000000000515BI0100001120 | 8 | each |
| 9 | 9 | 90.3.20.3 : Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | BI01010001010000000000000515BI0100001121 | 6 | each |
| 10 | 10 | 90.3.21.3 : Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture | BI01010001010000000000000515BI0100001122 | 25 | each |
| 11 | 11 | od104558/2019_2020 : Supply and fixing low glare high efficiency square surface mounted LED flat panel 230V 50Hz Compton make LCDSPLN-S-18-CDL 18 w light fitting complete with all required accessories etc. as required | BI01010001010000000000000515BI0100001123 | 4 | no |
| 12 | 12 | od106691/2019_2020 : Supply and fixing low glare high efficiency square surface mounted LED flat panel 230V 50Hz Compton make LCTLSN-S-36-CDL 36 w light fitting complete with all required accessories etc. as required | BI01010001010000000000000515BI0100001124 | 4 | no |
| 13 | 13 | od104560/2019_2020 : Supply, conveyance, installation, testing and commissioning of LED street light fitting (25 W, ) Crompton make LSTS-25-CDL /equivalent complete with all accessories and lamp etc.pre-wired light fitting of the following types complete with all accessories and lamps etc. in the existing GI pipe and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. | BI01010001010000000000000515BI0100001125 | 4 | no |
| 14 | 14 | od104562/2019_2020 : Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W LED light to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required. | BI01010001010000000000000515BI0100001126 | 5 | no |
| 15 | 15 | od104564/2019_2020 : Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with aluminium shade, 9W LED bulb and giving connection etc as required | BI01010001010000000000000515BI0100001127 | 7 | no |
| 16 | 16 | 90.3.18.1 : Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps | BI01010001010000000000000515BI0100001128 | 8 | metre |
| 17 | 17 | 90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | BI01010001010000000000000515BI0100001129 | 5 | each |
| 18 | 18 | 90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C | BI01010001010000000000000515BI0100001130 | 19 | each |
| 19 | 19 | 90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. | BI01010001010000000000000515BI0100001131 | 7 | each |
| 20 | 20 | od104566/2019_2020 : Supply, conveyance, installation, testing and commissioning of 225mm light duty exhaust fan in metal frame in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. | BI01010001010000000000000515BI0100001132 | 7 | no |
| 21 | 21 | 90.5.1.3 : Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell | BI01010001010000000000000515BI0100001133 | 2 | each |
| 22 | 22 | 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | BI01010001010000000000000515BI0100001134 | 100 | metre |
| 23 | 23 | 1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm | BI01010001010000000000000515BI0100001135 | 50 | metre |
| 24 | 24 | 1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | BI01010001010000000000000515BI0100001136 | 100 | metre |
| 25 | 25 | 1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | BI01010001010000000000000515BI0100001137 | 50 | metre |
| 26 | 26 | 1.17.22 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm | BI01010001010000000000000515BI0100001138 | 20 | metre |
| 27 | 27 | 1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm | BI01010001010000000000000515BI0100001139 | 80 | metre |
| 28 | 28 | 1.18.2 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair | BI01010001010000000000000515BI0100001140 | 30 | metre |
| 29 | 29 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | BI01010001010000000000000515BI0100001141 | 100 | metre |
| 30 | 30 | 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | BI01010001010000000000000515BI0100001142 | 50 | metre |
| 31 | 31 | 1.22.1 : Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.75 mm X 75 mm X 60 mm deep | BI01010001010000000000000515BI0100001143 | 2 | each |
| 32 | 32 | 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | BI01010001010000000000000515BI0100001144 | 14 | each |
| 33 | 33 | 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | BI01010001010000000000000515BI0100001145 | 9 | each |
| 34 | 34 | 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet | BI01010001010000000000000515BI0100001146 | 28 | each |
| 35 | 35 | 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | BI01010001010000000000000515BI0100001147 | 9 | each |
| 36 | 36 | od106695/2019_2020 : Supply and Fixing 20A DP Switch modular switches & accessories in the existing front plates and giving necessary connections as required (Group B) | BI01010001010000000000000515BI0100001148 | 2 | no |
| 37 | 37 | 1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet | BI01010001010000000000000515BI0100001149 | 2 | each |
| 38 | 38 | 1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet | BI01010001010000000000000515BI0100001150 | 1 | each |
| 39 | 39 | 1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | BI01010001010000000000000515BI0100001151 | 12 | each |
| 40 | 40 | 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) | BI01010001010000000000000515BI0100001152 | 7 | each |
| 41 | 41 | 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | BI01010001010000000000000515BI0100001153 | 12 | each |
| 42 | 42 | 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) | BI01010001010000000000000515BI0100001154 | 5 | each |
| 43 | 43 | 1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) | BI01010001010000000000000515BI0100001155 | 3 | each |
| 44 | 44 | 90.9.2.1 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid | BI01010001010000000000000515BI0100001156 | 30 | metre |
| 45 | 45 | 90.9.2.2 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider | BI01010001010000000000000515BI0100001157 | 20 | metre |
| 46 | 46 | 90.9.2.3 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree | BI01010001010000000000000515BI0100001158 | 2 | each |
| 47 | 47 | 90.9.2.4 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree | BI01010001010000000000000515BI0100001159 | 2 | each |
| 48 | 48 | 90.9.2.5 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree | BI01010001010000000000000515BI0100001160 | 2 | each |
| 49 | 49 | 90.9.2.7 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat cross | BI01010001010000000000000515BI0100001161 | 2 | each |
| 50 | 50 | 90.9.2.8 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap | BI01010001010000000000000515BI0100001162 | 4 | each |
| 51 | 51 | 90.9.2.11 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer | BI01010001010000000000000515BI0100001163 | 20 | each |
| 52 | 52 | 90.9.2.12 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box | BI01010001010000000000000515BI0100001164 | 2 | each |
| 53 | 53 | 90.9.2.13 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box | BI01010001010000000000000515BI0100001165 | 10 | each |
| 54 | 54 | od106693/2019_2020 : Supplying & drawing Cat 6 UTP 24AWGSolid cable to relevant standards through the existing conduit and giving connections as required | BI01010001010000000000000515BI0100001166 | 200 | metre |
| 55 | 55 | od104570/2019_2020 : Supply, testing and installation of Jack Cat6 Keystone UTP with Collapsible Shutter-White Make - D Link NKJ-C6WHI1B21 | BI01010001010000000000000515BI0100001167 | 14 | no |
| 56 | 56 | od104572/2019_2020 : Supply, testing and installation of Face Plate-Single(Keystone jack,square) Make - D Link NFP-OWHI11 | BI01010001010000000000000515BI0100001168 | 14 | no |
| 57 | 57 | od104574/2019_2020 : Supply, testing and installation of Back Box Make - D Link NBB-011 | BI01010001010000000000000515BI0100001169 | 14 | no |
| 58 | 58 | 90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) | BI01010001010000000000000515BI0100001170 | 1 | each |
| 59 | 59 | 90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) | BI01010001010000000000000515BI0100001171 | 1 | each |
| 60 | 60 | 2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door | BI01010001010000000000000515BI0100001172 | 4 | each |
| 61 | 61 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | BI01010001010000000000000515BI0100001173 | 30 | each |
| 62 | 62 | 2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral | BI01010001010000000000000515BI0100001174 | 4 | each |
| 63 | 63 | 2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | BI01010001010000000000000515BI0100001175 | 6 | each |
| 64 | 64 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001176 | 1 | each |
| 65 | 65 | od104576/2019_2020 : Supply and installation of 25 A four pole mini break isolator suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required | BI01010001010000000000000515BI0100001177 | 1 | no |
| 66 | 66 | od104578/2019_2020 : Supply and installation of 25 A double pole mini break isolator suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required | BI01010001010000000000000515BI0100001178 | 4 | no |
| 67 | 67 | od104580/2019_2020 : Supply and installation of 40 A, 4 pole, 30 mA RCCB for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 in the existing enclosure and giving connections as required | BI01010001010000000000000515BI0100001179 | 1 | no |
| 68 | 68 | od104582/2019_2020 : Supply and installation of 25 A, 4 pole, 30 mA RCCB for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 in the existing enclosure and giving connections as required | BI01010001010000000000000515BI0100001180 | 1 | no |
| 69 | 69 | od104584/2019_2020 : Supply and installation of 25 A, 2 pole, 30 mA RCCB for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 in the existing enclosure and giving connections as required | BI01010001010000000000000515BI0100001181 | 4 | no |
| 70 | 70 | 2.16 : Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001182 | 4 | each |
| 71 | 71 | 90.12.6.40 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm | BI01010001010000000000000515BI0100001183 | 20 | metre |
| 72 | 72 | 90.12.6.41 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm | BI01010001010000000000000515BI0100001184 | 25 | metre |
| 73 | 73 | 90.12.24.4 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm | BI01010001010000000000000515BI0100001185 | 25 | each |
| 74 | 74 | 90.12.24.5 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.16 sq mm | BI01010001010000000000000515BI0100001186 | 25 | each |
| 75 | 75 | 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) | BI01010001010000000000000515BI0100001187 | 2 | set |
| 76 | 76 | 9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) | BI01010001010000000000000515BI0100001188 | 2 | set |
| 77 | 77 | od104586/2019_2020 : Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for 4sqmm-16 sq mm sizes of cables with 12 mm wide x 1 mm thick clip as required. | BI01010001010000000000000515BI0100001189 | 4 | no |
| 78 | 78 | od104588/2019_2020 : Supply and drawing bare earthing conductors of size3.15 mm copper conductor (10 SWG) along with wiring/ cables and giving connection as required. | BI01010001010000000000000515BI0100001190 | 100 | metre |
| 79 | 79 | 5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | BI01010001010000000000000515BI0100001191 | 2 | set |
| 80 | 80 | od104590/2019_2020 : Supply and laying bare earthing conductors of size3.15 mm copper conductor (10 SWG) laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil). | BI01010001010000000000000515BI0100001192 | 20 | metre |
| 81 | 81 | od104594/2019_2020 : Supply and providing test joint for the earthing system using 2 Nos of 2x25x3mm of GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. | BI01010001010000000000000515BI0100001193 | 0.6 | metre |
| 82 | 82 | od104596/2019_2020 : Supplying , threading , laying and jointing of 20mm dia. 'B' class GI pipe with all required accessories in ground in the existing trench as protective covering to earth leads. | BI01010001010000000000000515BI0100001194 | 5 | per metre |
| 83 | 83 | od104598/2019_2020 : Supply and providing 25 x 6 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required | BI01010001010000000000000515BI0100001195 | 20 | no |
| 84 | 84 | od104600/2019_2020 : Supply and providing 25 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required | BI01010001010000000000000515BI0100001196 | 20 | no |
| 85 | 85 | od104602/2019_2020 : Supply and providing 12 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required | BI01010001010000000000000515BI0100001197 | 20 | no |
| 86 | 86 | od104604/2019_2020 : Supply of superior quality copper earth socket of size 3.15 mm (10 SWG) earth conductor including crimping etc. as required. | BI01010001010000000000000515BI0100001198 | 10 | no |
| 87 | 87 | od104606/2019_2020 : Supply and providing 25 x 3 mm GI strip earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. | BI01010001010000000000000515BI0100001199 | 10 | no |
| 88 | 88 | 2.1.2 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N | BI01010001010000000000000515BI0100001200 | 1 | each |
| 89 | 89 | od104608/2019_2020 : \"Supply and Installation / Fixing / Provision of Outdoor type HENSEL make (600X300x214 mm Mi 2410) suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with complete tamper proof SEALING facility. \" | BI01010001010000000000000515BI0100001201 | 1 | no |
| 90 | 90 | od104610/2019_2020 : Supply and fixing 2 -80A, DIN type fuse link of size 000 in the existing meter board and giving connections etc. | BI01010001010000000000000515BI0100001202 | 3 | no |
| 91 | 91 | od104612/2019_2020 : Supply and fixing 63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter board and giving connections etc. | BI01010001010000000000000515BI0100001203 | 1 | no |
| 92 | 92 | od104614/2019_2020 : Supply and fixing 63 A, 415 V, DIN type fuse base in the existing meter board and giving connections etc. | BI01010001010000000000000515BI0100001204 | 3 | no |
| 93 | 93 | od104616/2019_2020 : Supply, testing and installation of single phase 1/2 HP mono block open well pump (CRI / Texmo) | BI01010001010000000000000515BI0100001205 | 1 | Day |
| 94 | 94 | od104618/2019_2020 : Supply and providing starter suitable for 1 HP open well pump set | BI01010001010000000000000515BI0100001206 | 1 | no |
| 95 | 95 | od104620/2019_2020 : Supply and providing 1hp open well single phase motor pump set | BI01010001010000000000000515BI0100001207 | 1 | no |
| 96 | 96 | 90.6.6.3 : Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm | BI01010001010000000000000515BI0100001208 | 50 | metre |
| 97 | 97 | 90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size | BI01010001010000000000000515BI0100001209 | 30 | metre |
| 98 | 98 | 2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. | BI01010001010000000000000515BI0100001210 | 1 | each |
| 99 | 99 | od104622/2019_2020 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. | BI01010001010000000000000515BI0100001211 | 1 | no |
| 100 | 100 | od104624/2019_2020 : Supply & providing First Aid Chart duly framed and placed ina conspcious location for clear vision | BI01010001010000000000000515BI0100001212 | 1 | no |
| 101 | 101 | od104626/2019_2020 : Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required. | BI01010001010000000000000515BI0100001213 | 1 | no |
| 102 | 102 | od104628/2019_2020 : Painting letters or figures of size 2.50 cm, 4 cm or 5 cm height with enamel paint as identification mark to SB, DB, panel board etc as required | BI01010001010000000000000515BI0100001214 | 50 | no |
AI Tender Summary
Tender Timeline
Nov 01, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 14, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender