Road Transport and Highways Government Departments Closing in 0 days TDR #22305997

Upgradation Of Road From Chawmanu To Govindabari Road Via 32 Kilo (T21)/ Length - 32.164 Km / (Package No-Tr-04-05 P2) Including 1(One) Ls Bridge Under Chawmanu Block

Issued by Government Departments · Chawmanu, Tripura
Tender Value
58.46 Crore
Estimated cost
Bid Submission
19 Nov 2019
0 days left
EMD
1.16 Crore
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chawmanu → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Upgradation Of Road From Chawmanu To Govindabari Road Via 32 Kilo ( T21 ) / Length - 32.164 Km / ( Package No-Tr-04-05 P2 ) Including 1 ( One ) Ls Bridge Under Chawmanu Block

BOQ

Name of Work: Upgradation of road from Chawmanu to Govindabari road via 32 kilo (T21)/ Length - 32.164 km / (Package No-TR-04-05 P2) including 1(one) LS Bridge under Chawmanu block
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Road Works including Cross Drainage
22Clearing Grass and Removal of Rubbish
33Clearing grass and removal of rubbish up to a distance of 30 m outside the periphery of the area as per Technical Specification Clause 201.\n By manual means16.04hectare
44Cutting of Trees
55Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201.--- Lead upto 100 m.
66Girth above 600 mm to 900 mm2Nos
77Girth above 900 mm to 1800 mm17Nos
88Girth above 1800 mm to 2700 mm2Nos
99Dismantling of Structures
1010Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding whenever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and upto a lead of 1000 m as per Technical Specification Clause 202.\nBy Manual Means \n- Cement Concrete60.72Cum
1111Dismantling Brick/Tile Work as per Technical Specification No. 202
1212Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry including disposal of unserviceable material and stacking the serviceable material with all lift and upto a lead of 1000 m as per Technical Specification Clause 202\n- Cement Mortar39.35Cum
1313Removing all types of Hume pipes
1414Removing all types of Hume pipes and stacking within a lead of 1000 m excluding Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202 .\n
1515(a) Upto 600mm dia Hume Pipe22.5m
1616(a) Above 600mm to 900mm dia Hume Pipe103.5m
1717(a) Above 900mm dia Hume Pipe31.5m
1818Setting out
1919Setting Out (As per drawing enclosed) with Reference benchmark 1 no. , working benchmark 4nos. per km and near all drainage structure and bridges and Reference Pillars on both sides of the formation width Burjes @50m interval using PCC with jhama brick aggregate for all class of soil including marking of centre line, setting out curves and recording of levels etc. by Surveyor32.164km
2020Excavation in Cutting in soil by manual means with lead upto 50 m
2121Excavation in Roadway cutting in soil by using manual means and carrying of cut earth to embankment site with all lifts and lead upto 50 m as per Technical Specification Clause 302.3.46915.7Cum
2222Excavation in soil with Dozer with lead upto 100 m.
2323Excavation for roadway in soil by mechanical means with Dozer including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3140747Cum
2424Excavation in soil using Hydraulic Excavator and Trippers with disposal upto 1000 m.
2525Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections and transporting to the embankment location with all lifts and lead upto 1000 m as per Technical Specification Clause 302.3281494Cum
2626Construction of Embankment with Materials Obtained from Roadway Cutting
2727Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
2828For spreading within 100m123541Cum
2929Construction of Subgrade and Earthen Shoulders
3030Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site , spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.160109.4Cum
3131Compacting original ground supporting subgrade / sub-base
3232Loosening of the ground upto a level of 300 mm below the subgrade / sub-base level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.97296.1Sqm
3333Granular Sub-base with Well Graded Material ( Table 400.1 ) using Jhama Brick Aggregate
3434Construction of granular sub-base by providing well graded material ( Jhama Brick Aggregate , as per Table 400.1 ), spreading in uniform layers with tractor with attachments on prepared surface, mixing by mix in place method with rotavator at OMC, applying and brooming sand to fill up the interstices of coarse aggregate, watering and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.\nFor Grading - I Material ( jhama brick aggregate )14016.1Cum
3535Wet Mix Macadam [ WMM]
3636Providing, laying, spreading and compacting stone aggregates to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer ( Pug Mill ), carriage of mixed materials by tipper to site, laying in uniform layers in sub-base / base course on a well prepared sub-base and compacting with smooth wheel roller of three wheel 80-100 kN static roller to proper grade and camber, achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and as per Technical Specification Clause 406.27780.6Cum
3737Prime coat
3838(i) Low Porosity\nProviding and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.20 kg/sqm using mechanical means as per Technical Specification Clause 502.179913Sqm
3939Tack coat
4040Providing and applying tack coat with bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503179913Sqm
414120 mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/ modified bitumen) Binder
4242Providing , laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base , including mixing in a suitable plant, laying and rolling with a three wheel 80 - 100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C or Type D as per Technical Specification Clause 508.\nCase-I By Manual Means-\nBitumen VG-30179913Sqm
4343Seal Coat
4444Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A or Type B or Type C or Type D as per Technical Specification Clause 510\nA. By Manual Means\nCase-IV: Type D (with fine sand)\nBitumen VG-30179913Sqm
4545Road side Pucca Drains
4646Construction of road side pucca drain with M10 ( 1:3:6 with jhama brick aggregate) to specified lines, grades, levels and dimensions as per approved design and Technical Specification Clause 307, 1606. Excavated material to be used in embankment at site.
4747Trapezoidal drain ( top clear width 600 mm, bottom clear width 300 mm and clear depth of 400 mm\n(i) in ordinary soil15000m
4848Surface Drains
4949Construction of unlined surface drains of average cross-sectional area 0.4 sqm in ordinary soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3 m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.\n(i) Surface drain in ordinary soil\n- By Manual Means11020m
5050Traffic Signs and Road Appurtenances
5151Retro-reflectorised Traffic Signs
5252Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate ) 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawings and Technical Specification Clause 801
5353a) with 900 mm equilateral triangle aluminium sheeting350Nos
5454b) with 600 mm circular aluminium sheeting35Nos
5555Kilometre Stone (with RCC M15 Grade using Jhama brick aggregate):\n Reinforced cement concrete M15 grade ( using jhama brick aggregate ) kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703.
56565th Kilometre Stone (precast)6Nos
5757Ordinary Kilometre Stone (Precast)33Nos
5858Construction of 200 Metre Stone (Precast)128Nos
5959Providing and Fixing \"Logo\" of PMGSY Project
6060Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25 mm x 5 mm size on back on edges. The lower plate will be welded with MS angle iron frame of 25 mm x 25 mm x 5 mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75 mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete (using Jhama brick aggregate) M-15 grade blocks of 450 mm x 450 mm x 600 mm , 600 mm below ground level. The top most diamond plate will be welded to middle plate by 47 mm x 47 mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.12Each
6161Providing and Fixing “Citizen’s information Board”
6262Providing and fixing of typical Citizens' Information board with Logo as per MORD specifications and drawing. Two MS Plates of 2.0 mm thick, duly welded with MS flat iron 50 mm x 5 mm size on back on edges. The flat iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 76.1 mm OD (horizontal) and 2 Nos. 76.1 mm OD (Vertical) steel tube posts { as per IS : 1161 - 1979, Medium Class } duly embedded in cement concrete (using jhama brick aggregate) M-15 grade blocks of 600 mm x 600 mm x 750 mm , 750 mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube and flats will be painted with primer and two coats of epoxy paint as per drawing and specification Clause 1701 and Annexure 1700.1\n- Board \"A\"2Nos
6363Protection work- Retaining Wall
6464Excavation of Structures - A. Without dewatering
6565Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.\nIn ordinary soil --Upto 3 m depth\n2455.92Cum
6666Providing concrete for plain concrete ( using jhama brick aggregate ) in open foundations complete including formwork as per drawings & technical specifications Clauses 802, 803, 900, 1202 and 1203.-P.C.C grade M 10 ( using jhama brick aggregate )\n(i) Nominal mix 1:3:6491.18Cum
6767Construction of toe walls for protection of slopes as per Drawing and technical specifications Clause 1302.5\n-Brick masorny in cement mortar 1:4 in case of brick pitching4428.93Cum
6868Pointing with cement mortar (1:3) on brickwork as per drawing & technical specification Clauses 613.3 & 1204370.46Sqm
6969Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or PVC pipe ( 110 mm OD of 6.0 Kg/cm2 pressure ) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7.4961Nos
7070Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.81984.58Cum
7171Providing PCC M 20 (with jhama brick aggregate) architectural coping on the top of wing wall, return wall etc. complete including formwork as per drawing & technical specification Clauses 615, 710 & 1204.3.111654m
7272CD works
7373Foundation
7474Excavation of Structures - A. Without dewatering\nEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.\nIn ordinary soil --Upto 3 m depth\n4199.73Cum
7575Providing concrete for plain concrete ( using jhama brick aggregate ) in open foundations complete including formwork as per drawings & technical specifications Clauses 802, 803, 900, 1202 and 1203.\nPCC Grade M-15 (using jhama brick aggregate)\nNominal mix 1:2.5:5617.81Cum
7676Brick masorny work in cement mortar in foundation completed excluding pointing & plastering as per drawing & technical specifications Clauses 600, 1202 & 1203.\n- Brick masonry in 1:4 cement mortar1727.02Cum
7777Substructure
7878Brick masonry work in cement mortar in substructure complete excepting pointing & plastering, as per drawing & technical specification Clauses 602, 603, 604, 1202 and 1204 \n- Brick masonry in 1:4 cement mortar1030.22Cum
7979Plain/reinforced cement concrete in substructure complete including formwork as per drawings & technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204.\nRCC Grade M-25 \n-For height upto 5 m1068.65Cum
8080Supplying, fitting & placing TMT bar reinforcement (Fe415) in substructure completed as per drawings & technical specification Clauses 1002, 1005, 1010 and 1202115.94t
8181Pointing with cement mortar (1:3) on brickwork as per drawing & technical specification Clauses 613.3 & 1204125.23Sqm
8282Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or PVC pipe ( 110 mm OD of 6.0 Kg/cm2 pressure ) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7.1502Nos
8383Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.81138.24Cum
8484Providing PCC M 20 (with jhama brick aggregate) architectural coping on the top of wing wall, return wall etc. complete including formwork as per drawing & technical specification Clauses 615, 710 & 1204.3.11679.68m
8585Backfilling behind abutment, wing wall & return wall complete as per drawings & technical specification Clause 1204.3.8\n - Sandy material987.98Cum
8686Superstructure
8787Providing & laying reinforced cement concrete (using fine sand) in superstructure as per drawings & technical specifications Clauses 800, 900, 1205.4 & 1205.5\nRCC Grade M-25 \n-For height upto 5 m292.59Cum
8888Supplying, fitting, & placing TMT bar reinforcement in superstructure complete as per drawing & technical specifications Clauses 1002, 1010 & 120229.34t
8989Construction of R.C.C railing of M 25 grade(using fine sand) in cast-in-situ with 20 mm nominal size aggregate, true to line & grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.356m
9090Providing and fixing in position Drainage spouts complete as per drawing & technical specifications Clause 120940Nos
9191Providing bituminous wearing coat comprising of 20 mm thick premix carpet with seal coat Type D (with fine sand ) for culverts as per drawing & technical specifications Clauses 1206.2 and 5001070.15Sqm
9292Protection work- in CD
9393Excavation of Structures - A. Without dewatering\nEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.\nIn ordinary soil --Upto 3 m depth\n497.46Cum
9494Brick masorny work in cement mortar in foundation completed excluding pointing & plastering as per drawing & technical specifications Clauses 600, 1202 & 1203.\n- Brick masonry in 1:4 cement mortar116.42Cum
9595Providing and laying flooring laid over cement concrete (using jhama brick aggregate) bedding complete as per drawing and technical specification Clause 1303.\n- Cement concrete (using jhama brick aggregate) blocks cast in situ grade M15 ( size 400 mm x 400 mm x 150 mm ) over cement concrete ( with M10) bedding of 150 mm thick282.52Sqm
9696Providing concrete for plain concrete ( using jhama brick aggregate ) in open foundations complete including formwork as per drawings & technical specifications Clauses 802, 803, 900, 1202 and 1203.\nPCC Grade M-10 (using jhama brick aggregate)\nNominal mix 1:3:619.17Cum
9797Bridge Work: Long Span Bridges
9898Foundation
9999Excavation for structures
100100Without dewatering.\nEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.\n Ordinary Soil
101101- Upto 3 m depth782.74Cum
102102- 3 m to 6 m depth82.38Cum
103103Bored Cast-in-Situ piles 1200 mm dia , M-35 grade ( using fine sand ) RCC pile excluding reinforcement complete as per drawing and technical specification and removal of excavated earth with all lifts and lead upto 1000 m.504m
104104Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & technical specifications Clauses 802, 803, 900, 1202 and 1203.\nPCC Grade M-15\n Nominal mix 1:2.5:535Cum
105105Cement Concrete for Reinforced Concrete ( using fine sand ) in Pile Cap excluding reinforcement complete as per drawing and MoRTH technical specification.\nRCC Grade M-25 - using concrete mixer385.56Cum
106106Supplying, fitting & placing TMT bar reinforcement in foundation complete as per drawings & technical specifications Clauses 1000 & 1202104.52t
107107Providing steel liner 10mm thick for curbs and 6mm thick for piles including fabricating and setting out as per detailed drawing24.86t
108108Routine load test including supply of all tools & tackles required for testing, supply of kentledge, making all arrangement for testing, erection of kentledge, recording data analysing the data.1Nos
109109Substructure
110110Plain/reinforced cement concrete in substructure complete including formwork as per drawings & technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204.\nRCC Grade M-25
111111- Upto 3 m depth184.77Cum
112112- For height above 5 m upto 10 m92.81Cum
113113Supplying, fitting & placing TMT bar reinforcement (Fe415) in substructure completed as per drawings & technical specification Clauses 1002, 1005, 1010 and 120241.64t
114114Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or PVC pipe ( 110 mm OD of 6.0 Kg/cm2 pressure ) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7124Nos
115115Backfilling behind abutment, wing wall & return wall complete as per drawings & technical specification Clause 1204.3.8\n - Sandy material214.02Cum
116116Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.892.34Cum
117117Supplying, fitting & fixing in position true to line & level elastomeric bearing conforming to IRC:83 (Part-II) Section IX complete including all accessories as per drawings & technical specification Clause 1207.1311040cu.cm.
118118Supplying, fitting & fixing in position true to line & level elastomeric bearing conforming to IRC : 83 ( Part-II) Section IX complete including all accessories with additional steel fixtures as per drawings & technical specification with all lifts and lead upto 1000 m.138330cu.cm.
119119Superstructure
120120Plain / Reinforced cement concrete in superstructure including all formworks required as per drawings & MoRT&H technical specifications Clauses 1500, 1700, 2100. (including centering, shuttering, staging etc. but excluding reinforcement ) \nRCC Grade M-25 \n - For T-beam & slab superstructure
121121- Height upto 5 m191.36Cum
122122Supplying, fitting & placing HYSD bar reinforcement in superstructure complete as per drawings & MoRT&H technical specification Clauses 1600.38.27t
123123Construction of RCC railing of M 30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings ( No. SD / 202 ), including all formworks required and MoRT&H Technical Specification Clause 2703, 1500, 1600, 1700. (including centering, shuttering, staging etc. and reinforcement )107.54m
124124Providing and placing in position drainage Spouts complete as per drawing ( SD / 205 ) and MoRT&H Technical Specification Clause 515, 2705.18Nos
125125PCC M15 Grade leveling course below approach slab complete including all formworks required as per drawings and MoRT&H Technical Specification Clause 2700.7.69Cum
126126Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawings and MoRT&H Technical Specification Clause 2704, 1500, 1600, 1700.15.9Cum
127127Providing and laying cement concrete (using fine sand) wearing course M 30 grade including reinforcement complete as per drawings & technical specifications Clauses 800, 900 & 1206.330.16Cum
128128Strip Seal Expansion Joint\nProviding and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer / supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation as per drawings and MoRT&H Technical Specification Clause 2607.33.8m
129129Filler Joint
130130Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawings and MoRT&H Technical Specification Clause 2605.16.9m
131131Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawings and MoRT&H Technical Specification Clause 2605..16.9m
1321325 Year Routine Maintenance after Construction
1331331st Year Routine Maintenance32.164Km
1341342nd Year Routine Maintenance32.164Km
1351353rd Year Routine Maintenance32.164Km
1361364th Year Routine Maintenance32.164Km
1371375th Year Routine Maintenance32.164Km

AI Tender Summary

OUR REF NO 22305997
AUTHORITY Government Departments
TENDER VALUE 58.46 Crore
LAST DATE 19-11-2019
Authority
Authority Name Pradhan Mantri Gram Sadak Yojana
Work Description Upgradation Of Road From Chawmanu To Govindabari Road Via 32 Kilo ( T21 ) / Length - 32.164 Km / ( Package No-Tr-04-05 P2 ) Including 1 ( One ) Ls Bridge Under Chawmanu Block
Basic Detail
Tender No TR0405 P2
Bidding Type Tender
Location
City Chawmanu
State Tripura
Key Dates
Publish Date 30 Oct 2019
Submission Date 19 Nov 2019
Open Date 19 Nov 2019
Finance
Tender Value 58.46 Crore
Tender Fee 10000
EMD 1.16 Crore
Exemption Not Available
Document List
221BC3EF-17E3-4ED0-A449-3107817F9C34.html
Tendernotice_1.pdf
SBDDNIT12REVISEDWBRRPII.pdf
BOQ_148910.xls
8205540_4151_04112019.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 19, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

221BC3EF-17E3-4ED0-A449-3107817F9C34.html

pdf

Tendernotice_1.pdf

pdf

SBDDNIT12REVISEDWBRRPII.pdf

xls

BOQ_148910.xls

pdf

8205540_4151_04112019.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders