Housing Urban and Rular Development Government Departments Closing in 0 days TDR #22298887

Construction Of Multi Level Car Parking Cum Commercial Complex At Thampanoor Construction Of Multi Level 2 Wheeler And Car Parking Cum Commercial Complex At Thampanoor Thiruvananthapuram . The Project Comprises Of 5 Floors With Ground Floor For Four Whee

Issued by Government Departments · thiruvanthapuram, Kerala
Tender Value
16.39 Crore
Estimated cost
Bid Submission
21 Nov 2019
0 days left
EMD
5 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
thiruvanthapuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Multi Level Car Parking Cum Commercial Complex At Thampanoor Construction Of Multi Level 2 Wheeler And Car Parking Cum Commercial Complex At Thampanoor Thiruvananthapuram . The Project Comprises Of 5 Floors With Ground Floor For Four Wheeler Parking 1St 2Nd And 3Rd For Two Wheeler Parking And 4Th Floor Fo

BOQ

Name of Work: MLCP CUM COMMERCIAL COMPLEX , THAMPANOOR
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11CIVIL WORKSitem1
21.01Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soilitem22205.54Cum
31.02Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soilitem3670.931Cum
41.03Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.item41146.45Cum
51.04Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc.complete ( Measurements to be taken of the face area timbered):Depth exceeding 1.5 m but exceeding 3mitem5296.891sqm
61.05Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc.complete ( Measurements to be taken of the face area timbered):Depth exceeding 3 m but not exceeding 4.5 mitem69.016sqm
71.06Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soilitem71694.88sqm
81.07Supplying and filling with Crushed sand under floors, including watering, ramming consolidating and dressing etc. completeitem8206.707Cum
91.08Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos / Lindane emulsifiable concentrate of 20%item93840Litre
101.09Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentrationitem101210.72sqm
111.1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)item11124.998Cum
121.11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)item12129.253Cum
131.12Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)item134.59Cum
141.13Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations,footings, bases for columnsitem14153.432sqm
151.14Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).item1535.266sqm
161.15Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.item1635.266sqm
171.16Extra for laying concrete in or under water and or liquid mud including cost of pumping or bailing out water and removing slush etc. complete. Note for item No. 4.15 : - The quantity will be calculated by multiplying the depth measured from the sub-soil water level upto centre of gravity of concrete under subsoil water level with quantity of concrete in cum executed under the sub-soil water. The depth of centre of gravity shall be reconed correct to 0.10 m 0.05 m or more shall be taken as 0.10 m and less than 0.05 m ignored.item1788.032Cum
181.17Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.item18246.4sqm
191.18Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concreteitem19769.013sqm
201.19Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.item203354.29sqm
211.2Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs,landings, balconies and access platformitem215478.84sqm
221.21Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,girders bressumers and cantileversitem225252.35sqm
231.22Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings )except spiral - staircases)item23295.914sqm
241.23Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers,Abutments, Posts and Strutsitem242139.11sqm
251.24Centering and shuttering including strutting, etc. and removal of form for:Arches, domes, vaults up to 6m spanitem2564.034sqm
261.25Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or moreitem26320938Kg
271.26Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or moreitem27251931Kg
281.27Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth levelitem28395.963Cum
291.28Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V levelitem29634.524Cum
301.29Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work,using fly ash and cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- in charge. Note:- (1) Cement content considered in this item is @330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately. (2) Fly ash conforming to grade I of IS:3812 (Part-1) only be used as part replacement of OPC as per IS: 456. Uniform blending with cement to be ensured in accordance with clause 5.2 and 5.2.1 of IS: 456-2000 in the items of BMC and RMC.All works up to Plinth levelitem30318.791Cum
311.3Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).item31318.791Cum
321.31Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work,using fly ash and cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- in charge. Note:- (1) Cement content considered in this item is @330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately. (2) Fly ash conforming to grade I of IS:3812 (Part-1) only be used as part replacement of OPC as per IS: 456. Uniform blending with cement to be ensured in accordance with clause 5.2 and 5.2.1 of IS: 456-2000 in the items of BMC and RMC.All works above plinth & up to floor V levelitem321274.76Cum
331.32Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS: 1838,including cost of primer, sealing compound in expansion joints.item332883.6cm depth per 100 m
341.33Providing and fixing sheet covering over expansion joints with iron screws as per design.Aluminium fluted strips 3.15 mm thick150 mm wideitem34336.24metre
351.34Providing wire mesh in recessed/column /beam wall joints including making good the surface etc complete.item35552.792sqm
361.35Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM1:6 ( 1 cement : 6 coarse sand ) etc completeitem3618.669Cum
371.36Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc completeitem37443.385Cum
381.37Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc completeitem38487.039Cum
391.38Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)item39105.236Cum
401.39Stone tile work for wall cladding upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand), including pointing with matching colour to tile with an admixture of pigment to match the stone shade.8 mm thick (mirror polished and machine cut edge)Granite stone of any colour and shadeitem401270.37sqm
411.4Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-incharge.a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.item41355.857sqm
421.41Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite workitem42441metre
431.4262 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate,6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.item434632.8sqm
441.43Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.item444632.8sqm
451.44Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.item45868.72sqm
461.45Providing and laying Vitrified anti skid floor tiles of size 300x300 mm (thickness to be specified by the manufacturer),with water absorption less than 0.08% and conforming to IS: 15622, of approve make, in colours and shades, laid on 20 mm thick cement mortar 1:4(1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including grouting the joints with white cement and matching pigment etc.complete.item4680.872sqm
471.46Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.item47218.287sqm
481.47Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Ordinary cement without any pigmentitem48365.537sqm
491.48Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks,lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour,design& pattern.item49480.783sqm
501.49Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by weldingitem504884.45Kg
511.5Extra labour for additional ornamental works for making MS grill for required openings including all rates etc complete as per the direction of Engineer in Charge.item5170.394sqm
521.51Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top coveritem5243.201sqm
531.52Providing and fixing ball bearing for rolling shutters.item538No
541.53Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksitem54972.925Kg
551.54Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)item552341.19Kg
561.55Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level,suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit.item56770.127sqm
571.56Providing and fixing powder coated aluminium work for false ceiling ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws,aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge.item573080.51Kg
581.57Finishing roof tile (Pressed clay tile) with Roof coat paint of approved make (Premium class exterior paint) including all rates etc complete as per the direction of engineering charge.(The rates are including all scaffolding works).item58380.491sqm
591.58Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on RCC roof top etc complete as per the direction of Engineer in charge.item59299.685sqm
601.5912 mm cement plaster of mix:1:4 (1 cement : 6 fine sand).Internal Plasteringitem607154.63sqm
611.6Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plasteritem61533.668sqm
621.6112 mm cement plaster of mix:1:4 (1 cement : 6 fine sand).-External Plasteringitem627097.37sqm
631.629 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc completeitem639156.59sqm
641.6318 mm thick plain cement mortar band in cement mortar 1:4 ( 1 cement : 4 fine sand):Raised Banditem64500meter length per cm
651.6418 mm thick plain cement mortar band in cement mortar 1:4 ( 1 cement : 4 fine sand):Moulded Banditem65500meter length per cm
661.65Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.item663436.64sqm
671.66Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.item676225.71sqm
681.67Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primeritem6816620sqm
691.68Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)item696778.33sqm
701.69Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new workitem7016620sqm
711.7Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new workitem71383.662sqm
721.71Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)item72611.2sqm
731.72Finishing with Epoxy paint of 3mm thick coat (one coat primer, 2mm screed and 1mm finishing coat ) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete workitem734613.27sqm
741.73Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)item7437.512cum
751.74Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.item75210.827Cum
761.75Demolishing R.B. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.item76118.231Cum
771.76Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge.item77180.752sqm
781.77Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortaritem7878.601Cum
791.78Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats,architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and belowitem7915Each
801.79Providing and fixing white vitreous china pedestal type European closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete.item8020Each
811.8Providing and fixing wash basin with sensor type unit of approved make and size , 32 mm C.P. brass waste of standard pattern, including painting of fittings and fix over granite slab, cutting and making good the walls / granite plat form wherever require:ect as per the direction of engineer in chargeitem817Each
821.81Providing and fixing Urinal systems 580x380x350 or nearest size of approved make with sensor of size (W 130 x H 130 x D 72 mm) with all fixtures automatic flushing cistern, with fittings, standard size C.P.brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS standares, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre PVC. automatic flushing cisternitem824Each
831.82Supplying and fixing approved quality white vitreous china urinal division plate of size 900 mm x 450mm including cost and conveyance of all material, labour charge, lead, lift, all taxes etc. complete as directed by the Engineer-in-Charge.item834No
841.83Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.item8420No
851.84Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.item8527No
861.85Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.item867Each
871.86Providing and fixing toilet paper holder:Vitreous chinaitem8720no
881.87Providing and fixing brass stop cock of approved quality :15 mm nominal boreitem885Each
891.88Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.item8927No
901.89Providing and fixing CP Hand rail in dissabled toilets of approved make including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.item908Each
911.9Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal boreitem9151Each
921.91Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, Collar and bush approved quality and colour .15 mm nominal bore with 30 cm lengthitem9231Each
931.92Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal boreitem9320Each
941.93Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal boreitem945Each
951.94Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal boreitem953Each
961.95Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.item9696No
971.96Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal boreitem974Each
981.97Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2item98120metre
991.98Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2item9940metre
1001.99Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2item10040metre
1012Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10Kgf/cm2- External work- Exposed on wallitem10150metre
1022.01Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wallitem102150metre
1032.02Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wallitem10390metre
1042.03Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2item104120metre
1052.04Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes.110 mm diameteritem105360metre
1062.05Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansionBend 87.5°.110 mm benditem10648Each
1072.06Providing and fixing unplasticised- PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length,including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete.110 mmitem107360No
1082.07Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.item10824Each
1092.08Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wallitem10940metre
1102.09Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching,refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2item110150metre
1112.1Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2item11130metre
1122.11Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansionShoe (Plain)110 mm Shoeitem11224Each
1132.12Providing and fixing CP brass concealed floor trap of 110 mm outer dia(multi trap) including CP cockroach free floor grating with cup etc including cost and conveyance of all materials, labour charges,sundries etc complete as directed by the Engineer- in-charge at all levelsitem11323Each
1142.13Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.waste fittings complete.Semi rigid pipe32 mm diaitem1147Each
1152.14Providing and laying cement concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design:150 mm diameter S.W. pipeitem11530metre
1162.15Providing and laying cement concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design:100 mm diameter S.W. pipeitem116100metre
1172.16Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5item1175Each
1182.17Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x 90 cm and 90 cm deep including C.I. cover with frame ( heavy duty ) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg ( weight of cover 108 kg and weight of frame 100 kg)With common burnt clay F.P.S. ( non modular) bricks of class designation 7.5item1186Each
1192.18Providing and fixing in position Pre-cast SFRC manhole cover and frame heavy duty of required shape and approved quality.Rectangular shape 600x600 mm internal dimensionsitem11912Each
1202.19Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber etc.: for water connection below 80 mm dia nominal boreitem1201Each
1212.2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)item1212871.6Kg
1222.21For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)item1222672.14Kg
1232.22Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thicknessitem12340Each
1242.23Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm),with necessary accessories and screws etc. complete.item1248No
1252.24Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. completeitem12563Each
1262.25Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick:Float glass panes4 mm thick glass paneitem126169.43sqm
1272.26Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick:5.5mm thick glass paneitem12775.241sqm
1282.27Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sidesitem12856.43sqm
1292.28Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/Gypsum work by providing weather/structuralnon sag elastomeric PU sealant over backer rod of approved quality as perarchitectural drawings and direction of Engineer-in-charge complete,complying to ASTM C920, DIN 18540-F & ISO 11600Upto 10 mm depth and 10 mm widthitem129906.001metre
1302.29Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mmitem13088No
1312.3Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mmitem13188No
1322.31Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete:125 mmitem132176No
1332.32Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-charge Extruded section profile size 48x40 mmitem13374.25metre
1342.33Providing and fixing to existing door frames30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (±0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineerin-charge.item13423.626sqm
1352.34Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/ top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer - in-charge.200 x 19 x 1.9 mmitem13572No
1362.35Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/ top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer - in-charge.300 x 19 x 1.9 mmitem136102No
1372.36Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS : 3614 (Part - II), tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer -in-charge (panneling to be paid for separately).item13737.8sqm
1382.37Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excludeditem13881metre
1392.38Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqmitem139438.158sqm
1402.39Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm.item14069.809sqm
1412.4Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.item141100.367sqm
1422.41Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade - I ( hessian based self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea- sized gravel spread at 6 cubic diameter per square metre including preparation of surface but excluding grading complete with:Bitumen felt ( hessian base) type 3 grade I conforming to IS : 1322item142761.723sqm
1432.42Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thickitem1431526.47sqm
1442.43Providing and fixing of Corner guard for protecting column, made with thermo e polymer, Size : width 82mm X 82 mm and an average height 800mm with outer wall thickness of 3mm and supporting beams thickness 5mm having proven tensile strength 55kg per cm, elongation 50%, hardness 70±5 shore – A ,with excellent UV resistance and water resistance including two or more PVC reflector strip of 18mm x3mm on the top of profile. The profile will fixed with 6mm steel anchor fastener etc. complete as per the direction of Engineer in Charge.item144400Each
1452.44Supply and fixing of Polycarbonate convex mirror, with strong convex mirrors stronger than glass made up of unbreakable polycarbonate mirrors, highly reflective mirrors have 130 degree of viewing angle.Viewing distance should not be less than 15metre. The bracket system on the backside is used to mount it on the pole it also has an option of separate wall mounting bracket for indoor use and option of floor mounting bracket / stand for outdoor use and also most suitable for blind turns the industry of application includes all construction sites etc complete including all rates as per the direction of engineer in charge.item1454Each
1462.45Supply and Fixing High Quality Rubber polymer End cap 50mm thick (Heavy duty) made of synthetic imported polymer material, abrasion resistance, impact resistance, tear resistance and longer life, weight 16 kg per metre, colour: yellow & black size: square piece 350 x 250 x 50 mm capacity not less than minimum of 50 including all rates etc complete as per the direction of engineer in charge.item1464Each
1472.46Supply and Fixing High Quality Rubber polymer speed breakers 50mm thick (Heavy duty) made of synthetic imported polymer material, abrasion resistance, impact resistance, tear resistance and longer life, weight 16 kg per metre, colour: yellow & black size: square piece 350 x 250 x 50 mm capacity not less than minimum of 50 including all rates etc complete as per the direction of engineer in charge.item14771.15RM
1482.47Supplying and fixing high quality rubber wheel stopper of approved make, standard size and required colour including all rates etc complete as per the direction of engineer in charge.item14842Each
1492.48Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)Complete as per designitem14942Each
1502.49Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Concrete Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes, etc complete as per the direction of engineer in charge.item150115sqm
1512.5Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified,excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth, pile top chipping with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).750mm dia pilesitem151478.8metre
1522.51Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified,excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth, pile top chipping with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).600mm dia pilesitem1524488.75metre
1532.52Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc.complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityInitial testitem1532Per Test
1542.53Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc.complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityRoutine testitem1545Per Test
1552.54Integrity testing of pile using Low Strain / Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge. Note:- The inclusion of the above item in the schedule of work shall be judiciously decided by the technical sanctioning authority,keeping in view the quality control, type of soil strata & importance of the project.item1555Per Test
1563ELECTRICAL WORKSitem156
1573.01Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireitem1571500Metre
1583.02Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group Aitem15860Point
1593.03Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wireitem1592000Metre
1603.04Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wireitem160600Metre
1613.05Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group Aitem161660Point
1623.06Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switchitem162150Each
1633.07Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)item16330Each
1643.08Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)item16415Each
1653.09Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).item16566Each
1663.1Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.item16666Each
1673.11Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. lCDitem16714Each
1683.12Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415volts \"C\" curve TP MCB complete with connections, testing and commissioning etc. as required.item1685Each
1693.13Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.item16970Each
1703.14Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm aluminium stripitem170180Metre
1713.15Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm aluminium stripitem171200Metre
1723.16Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.item17210Each
1733.17Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.item17370Metre
1743.18Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.item17411Set
1753.19Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)item175500Metre
1763.2Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)item176150Metre
1773.21Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)item177565Metre
1783.22Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper stripitem178110Metre
1793.23Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper stripitem17960Metre
1803.24Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)item180230Metre
1813.25Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)item18114Each
1823.26Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)item18240Each
1833.27Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)item18348Each
1843.28Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thicknessitem184200Metre
1853.29Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thicknessitem1855Nos
1863.3Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thicknessitem1866Nos
1873.31Supplying and installing following size of perforated pre-painted M.S. cable trays reducers withperforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.200 mm width X 50 mm depth X 1.6 mm thicknessitem1873Nos
1883.32Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)item18870Sqm
1893.33Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etcitem1893Sqm
1903.34Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheetitem190150Metre
1913.35Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)item1919Metre
1923.36Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.item1922600Cum Cm
1933.37Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel without block reactor.item1931Each
1943.38Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.15 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel without block reactor.item1943Each
1953.39Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheetitem19540Metre
1963.4Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel boarditem19665Kg
1973.41Supply and providing copper earth bus in the panel boarditem197900Cum Cm
1983.42Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OLitem19812Nos
1993.43Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SCitem1993Nos
2003.44Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SCitem2002Nos
2013.45Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SCitem2011Nos
2023.46Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SCitem2021Nos
2033.47Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single poleitem203260Each
2043.48Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 ampsitem20415Each
2053.49Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple poleitem20516Each
2063.5Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 ampsitem2067Each
2073.51Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 ampsitem20710Each
2083.52Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 ampsitem2082Each
2093.53Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 ampsitem20912Each
2103.54Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 ampsitem2107Each
2113.55Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 ampsitem2111Each
2123.56Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.item2122Each
2133.57S & F Motor starters of the following ratingsSemiautomatic star delta starter for 5 to 7.5HP motoritem2133Each
2143.58Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)item21413Each
2153.59Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)item2159Each
2163.6Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mmitem216250Metre
2173.61Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 16 sq mmitem21730Metre
2183.62Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 185 sq mmitem21850Metre
2193.63Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mmitem219480Metre
2203.64Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mmitem220130Metre
2213.65Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 95 sq mmitem221105Metre
2223.66Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 120 sq mmitem22225Metre
2233.67Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mmitem22350Metre
2243.68Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 240 sq mmitem22435Metre
2253.69Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 400 sq mmitem22525Metre
2263.7Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)item22610Set
2273.71Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm)item2272Set
2283.72Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:240 sq. mmitem2282Each
2293.73Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)item22920Set
2303.74Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)item2306Set
2313.75Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)item2312Set
2323.76Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)item2322Set
2333.77Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)item2334Set
2343.78Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)item2342Set
2353.79Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)item2352Set
2363.8Supply, Installation, Testing & Commissioning of 20 W, system efficacy >100lm/W, Integral Surface Mounted Device (SMD), IP 66, LED Bi-directional Wall Light with housing made with Extruded Aluminum, for better heat dissipation.Product comprising of LED with 3000K. LED make shall be of Cree/Osram/Nichia/Ever light/Samsung. Fixtures should have tough ended glass with 22°Beam. The luminaire shall have IP66 protection. The LED shall be compliant with Useful L70 life of >50000 Hrs. LED Driver shall be Isolated type, Constant Voltage topology driver in metal enclosure with IP 66 Protection. Driver efficiency should be 85% & proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3 KV internal surge protection. LED driver shall have output short circuit & over voltage protection inbuiltitem23670Each
2373.81Supply and Installation of LED outdoor wall light, 15W with Aluminium pressure Die cast housing ,diffuser, Toughened glass cover with IP67 protection, High efficiency LED mounted on aluminium heat sink for effective heat dissipation, Electronic driver duly wired up to terminal block. CRI >70,Temperature range- 0 to 50DegC, Driver efficiency>85%, Power factor>0.95, THD<10%, Colour Temperature- 2700K, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. and System efficacy>100lm/Witem23740Each
2383.82Supply and Installation of outdoor type LED bulkhead luminaire 10w, with Hight Transmittivity Diffuser for better light output and uniform light distribution without glare. Driver and accessories are pre-wired for easy installation and long service.CRI>70, LED efficacy 100lm/W, including accessories and giving connections as required.item23812Each
2393.83Supply and Installation of Slim panel Surface mounted LED downlighter 18W, with housing made up of die cast aluminium for better heat management. Hight Transmittivity Diffuser for better light output and uniform light distribution without<br>glare. Driver and accessories are pre wired for easy installation and long service.CRI>70, LED efficacy 100lm/W,item239495Each
2403.84Supply, conveyance, installation, testing and commissioning of 82.5kVA Diesel Generator set with integral acoustic enclosure as per CPCB Norms with AMF control panel with accessories s per technical details given below,1.Engine a)Make of engine – Kirloskar/Cummins/ b)Type f Engine – Diesel Engine c)No. of Cylinders – As per Standards d)Method of Cooling –Water cooled with radiator e)Design – Suitable for Generator operation 2.Standard accessories with diesel engine a)Flywheel to suit flexible coupling b)Close Coupling c)Air Cleaner d)Radiator with fan provided with fan guard e)Fuel Pump f)Fuel Filter g)Lubricating Oil Filter h)Exhaust Silencer i)Exhaust Muffler j)Battery charger 3.Engine Instrument Panel a)Starting switch with key or button b)Lubricating oil pressure gauge c)Water temperature gauge d)RPM indicator with hour meter e)Battery charging ammeter 4.Safety controls for Engine a)Trip for low lubricating oil pressure b)Trip for high water temperature 5.Alternator(Brushless) a)Make –Kirloskar/Stamford/KEL b)Type – Self exited and selfregulated c)Capacity – 82.5kVA /66KW @0.8 PF d)System Voltage –415V e)Frequency – 50Hz f)Insulation – Cass F/H, the alternator should confirm to IS4722.6.Fuel Tank Suitable size built in type integrated with acoustic enclosure. Fuel connection shall be done as per standards.7.BatterySuitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufacturers requirement.8.Automatic battery charger Solid state phase indication lamp for supply ON/OFF with HRC protection.9.Standard Control Panel as per Kerala Electrical Inspectorate requirements with 125A 4 pole MCCB and accessories such as multi-function meter and separate energy meter etc. with 36 months comprehensive maintenance warranty from date of commssioningitem2401Each
2413.85Supply, conveyance, testing and commissioning of 250kVA Unitised Sub Station.HT portion shall consists of:1 No, 350 MVA 630A Air Circuit breaker suitable for 3 phase, 3 wire. 50 Hz system with HT HRC Fuses of appropriate rating with earth switch inter lock with main switch and mechanical ON/OFF indication.Shunt trip coil for the remote operation of the load break Switch with necessary Earth fault potection relay etc.1 Nos. 0-12 KV (or nearest range) Volt Meter with Selector Switch 3 Nos. 0-10 A (or nearest range) Ammeter Necessary Cast resin type CT & PT for connecting Ammeter and volt Metre. For 250kVA transformer Transformer portion 1 No 250kVA, 11KV/433V, 50 HZ Delta/Star connecting, cast resin insulated,copper wound transformer. Laser scribed core shall be used. Class F insulation level shall be maintained. OFF load tap changing facility shall be incorporated so as to achieve tap positions of +/-2.5%x4. Temperature scanner with trip mechanism and annuciator shall be provided. The transformer shall conform to IEC 726 and IS 11171/1985 re-affirmed in 1991. The LT Portion shall be provided with 1No 630 A, 4 pole, 50kA microprocessor-based MCCB with adjustable OL, SC. All interconnections from HT Load Break Switch to transformer and transformer to LT breaker shall be given using electrolytic copper bus bar insulated with heat shrink sleeves and tinned at the points of contacts. All internal earth connections are to be given as per standards.Necessary provision shall be made for giving cable connection of H.T side as well as on L.T side.Phase barriers and shrouding as per standards has also be given. Adequate provision shall be made for LT side, CT energy meter for Audit purposes.The enclosure shall fabricated using 2mm MS sheet and shall comply with IP 20 standards and shall be powder coated after seven tank processing and phosphating. The USS shall be installed as per the directions of Engineer in charge.item2411Each
2423.86Supply and Installation of 12KV Ring Main Unit, Outdoor Type with enclosure,Rated short time withstand(main and earth) 20 kA 3 seconds, 630A continuos,rated current, Normal ambient temperature 25 °C to + 40 °C, IP 67 Rated High voltage live parts, SF6 tank, 300 mm2 three core or 500 mm2 single core maximum cable size, fuses confirming to IEC 60282-1, DIN 43625,item2421Each
2433.87Earthing with GI Earth plate 1200mm x 1200mm x 12 mm thick including accessories and providing masonry enclosure with coer plate having locking arrangement and watering pipe of 2.7m longetc with charcoal/coke and salt as requireditem2435Each
2443.88Supply and Installation of LED Bush/Spike 15W light with Aluminium pressure Die cast housing ,diffuser, Toughened glass cover with IP67 protection, High efficiency LED mounted on aluminium heat sink for effective heat dissipation,Electronic driver duly wired up to terminal block. CRI >70,Temperature range- 0 to 50DegC, Driver efficiency>85%, Power factor>0.95, THD<10%, Colour Temperature- 3000K, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard and System efficacy>100lm/Witem24420Each
2453.89Supply, laying and termination of one number A2XFY / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.3C 185sq.mmitem24535Metre
2463.9Supply and Installation of LT cable route marker, cast Iron, spike and inscription L.T Cableitem2467Each
2473.91Supply and fixing of 3 phase, 4 wire, 110V (L-L), -/1A CT or -/5A CT, accuracy class 0.2, TOD Meter in existing metering provision.item2471Each
2483.92Supply and Fixing of exhaust pipe for DG using MS C Class pipe of 80 mm dia including accessories and clamping etc.item24820Metre
2493.93Supply and fixing of Control wiring with 1.5 sq.mm PVC insulated copper wire in the existing panels and giving connections as required.item24925Metre
2503.94Supply and fixing of 800A, 4 pole, 50kA, Electrical draw out type microprocessor-based ACB with Overload, Instantaneous short circuit, delayed short circuit and ground fault protection in the existing panel and giving connections as required.item2501Each
2513.95Supply and fixing of 25 x 3 mm brass bolt with hexagonal/ square head, nut and washer.item251100Each
2523.96Supply and fixing of 12 x 3mm brass bolt with hexagonal/square head, nut and washer.item252100Each
2533.97Supply and installation of 8 stage intelligent power factor 440V, 5A/1A, IPFCitem2531Each
2543.98Supply and Fixing of 2.00mm thick, 3.3kV, 2m x 1m, Synthetic Eastomeric Fire Retardant Insulation Sheet.item25416Each
2553.99Supply and Installation of IP 65 rated polycarbonate empty enclosure for accommodating test joint of lightning protectionitem25510Each
2564SITC of 3 phase Multi-Function meter to read: V, A, F, class 1 including accessories and giving connections as requireditem2564Each
2574.01SF of 240/220 V, LED (22.5 mm dia ) Pilot lamp with integral circuit, terminal block, including connection etc. as required. - Red/yellow/Green / Blue / Orange colouritem25712Each
2584.02SF of Current Transformer , with all necessary support in existing panel including connection etc. as required . - from 200 / 5 to 400/5 Ratio , 10 VA , class 1 accuracyitem25816Each
2594.03Supply and Installation of 7.5 HP Centrifugal monoblock pump, min. discharge 600LPM, 15m head. 440V, B class insulation, IP55 protection, Cast Iron/ Bronze/ Stainless steel Impeller, with cast iron delivery casing, Cast Iron Motor Body, with carbon steel/ stainless steel Pump Shaft, with Mechanical seal for ingress protectionitem2592Each
2604.04Painting of letters/figures of sizes 2.5, 4cm or 5cm height using synthetic enamel paint.item260250Each
2614.05Charges for copying of electrical drawings in A3 sheet for submission to concerned authorities.item261150Each
2624.06Charges for preparing First Copy of electrical drawings in A3 sheet for submission to concerned authoritiesitem26210Each
2634.07Charges for getting Energization Sanction from KSELB/KSEB ( Actuals will be reimbursed upon submission of original reciept)item2631L S
2644.08Supply, Installation, Testing and Commissioning of 1 Nos 8 Passenger Lift, Gearless lift (Machine room less)Technical Specification:1)Type of Lift Passenger lift-Gearless. 2) Load /Persons 544 Kg/8 persons Lift.3) Rated Speed 1M/Sec.4)Travel 16Mtr (Approx.).5)No .of Floor and entrance Ground + 4 upper Floors –5 Openings.6)No.of Floor Served 5 Floors.7) Method of control Microprocessor based V3F with ARD system.8)Location of Machine Room Machine room less.9)Size of Lift well 1950 mm x 1850 mm.10) Car entrance As per IS.11)Levelling Accuracy As per IS.12)Car door Opening As per IS.13)Drive Variable voltage variable frequency (V3F).14)Operation Simplex full selective collective control with ON/OFF switch.15)Construction of design and Vandal proof stainless steel finish cabinet with scratch proof stainless Furnishing of car body work Steel door, stainless steel mirror finish ceiling, Stainless steel 6mm Flooring, fan with timer cut-off, push to talk, LED display, LED light, Handrail and floor announcement system.16) Landing entrance Automatic center opening Vandal proof stainless steel sliding door as per ISS with provision for mechanical opening key for emergency with full length infra red light curtains and stainless steel framed ½ glass door.17)Call and Position indicators Up/down direction & position Dot Matrix LED indication shall be provided at all Landings.18)Electric Supply 1) Light 230V/50Hz/Single phase 2 wire system 2) 415V/50Hz/ 3 phase 4 wire system.19) Infra-red door opening system To be provide for entire length of the door.20)Automatic Rescue Device Provide automatic rescue device with an electronic controller powered by 4 Nos.12V 24 AH dry free maintenance batteries. The rescue operation should act with In 10 seconds of power failure .21) Regulation 350V – 450V (SMPS based).22) Indication in the car a) Car Position b) Call indicator c) Door close/open push button d) Emergency stop button e) Flush mounted switch for fan and light f) Nonstop button g) Battery operated emergency lamp with rechargeable batteries h) Battery operated alarm bell i) Intercom wiring with one master unit with two slaves j) Fireman’s switch at main lobby k) Auto attendant control (inside the car). 23) Winding handle Manual winding handle for use in emergency .24) Safeties a) Over Speed governor, operated safety gear b) Buffers c) Motor over load protection d) Phase reversal protection e) Other safeties as per ISS f) Single phase preventer g) Final Limit switch.25) Levelling Automatic levelling at all landing as per ISS.26)Guarantee Company shall carry out free maintenance during warranty period of 36 months which also include a)Cleaning lift equipment b)lubrication of all moving parts.c)Replacing of lubricating oil when required d)Checking and adjusting contacts e)Replacing fusible item alarm etc.f)Recharging batteries in case of drain/renewing batteries.g)Replacing /rewinding of all defective parts of the lift including motors and V3F unit.27)Control Panel Control Panel will be dust and vermin proof of sheet metal enclosure.28)Announcement System To provide lift announcement system.29)Tests At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over.30)Scope of work:- a) Supply of lift materials.b) Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing /altering civil works in lift entrance/pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, cutting pockets and grounding pockets for the guide rails, grouting boxes for control units, correction of wall opening in the front side of the wall by additional brick work or cutting existing brick work.C) Scaffolding.d) Door frames.e) Supporting steel.f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account. g) Intercom facilities with one master and two slaves. h) Battery operated alarm.i) Obtaining scheme approval as well as energization certificate from the electrical Inspectorate including preparation of necessary drawing for the same. Necessary fee shall remitted to the Inspectorate by the firm for which no refund will be made from the department including taking insurance for one vear as per new lift rule. j) Supply of book let with complete details of maintenance schedule and control diagram.k) Giving training to department staff for attending trouble shooting. l) Free servicing for 36 months after handing overitem2641Each
2654.09Supply, Installation, Testing and Commissioning of 1 Nos 15 Passenger Bed Lift, Gearless lift (Machine room less)Technical Specification:1)Type of Lift Passenger lift-Gearless.2)Load /Persons 1020 Kg/15 persons Bed Lift.3)Rated Speed 1M/Sec.4)Travel 16Mtr (Approx.).5)No .of Floor and entrance Ground + 4 upper Floors –5 Openings.6)No.of Floor Served 5 Floors.7)Method of control Microprocessor based V3F with ARD system.8)Location of Machine Room Machine room less.9)Size of Lift well 3000 mm x 1850 mm.10)Car entrance As per IS.11)Levelling Accuracy As per IS.12)Car door Opening As per IS.13)Drive Variable voltage variable frequency (V3F).14)Operation Simplex full selective collective control with ON/OFF switch.15)Construction of design and Vandal proof stainless steel finish cabinet with scratch proof stainless Furnishing of car body work Steel door, stainless steel mirror finish ceiling. Flooring, fan with timer cut-off, push to talk, LED display, LED light, Handrail and floor announcement system.16)Landing entrance Automatic center opening Vandal proof stainless steel sliding door as per ISS with provision for mechanical opening key for emergency with full length infra red light curtains and stainless steel framed ½ glass door.17)Call and Position indicators Up/down direction & position Dot Matrix LED indication shall be provided at all Landings.18)Electric Supply .1) Light 230V/50Hz/Single phase 2 wire system.2) 415V/50Hz/ 3 phase 4 wire system.19) Infra-red door opening system To be provide for entire length of the door.20)Automatic Rescue Device Provide automatic rescue device with an electronic controller powered by 4 Nos.12V 24 AH dry free maintenance batteries. The rescue operation should act with In 10 seconds of power failure.21)Regulation 350V – 450V (SMPS based).22)Indication in the car a) Car Position. b) Call indicator.c) Door close/open push button.d) Emergency stop button.e) Flush mounted switch for fan and light.f) Nonstop button.g) Battery operated emergency lamp with rechargeable batteries.h) Battery operated alarm bell.i) Intercom wiring with one master unit with two slaves.j) Fireman’s switch at main lobby.k) Auto attendant control (inside the car).23)Winding handle Manual winding handle for use in emergency.24)Safeties a) Over Speed governor, operated safety gear.b) Buffers.c) Motor over load protection.d) Phase reversal protection.e) Other safeties as per ISS.f) Single phase preventer.g) Final Limit switch.25)Levelling Automatic levelling at all landing as per ISS.26)Guarantee Company shall carry out free maintenance during warranty period of 36 months which also include.a)Cleaning lift equipment.b)lubrication of all moving parts.c)Replacing of lubricating oil when required.d)Checking and adjusting contacts.e)Replacing fusible item alarm etc.f)Recharging batteries in case of drain/renewing batteries.g)Replacing /rewinding of all defective parts of the lift including motors and V3F unit.27)Control Panel Control Panel will be dust and vermin proof of sheet metal enclosure.28)Announcement System To provide lift announcement system.29)Tests At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over.30)Scope of work:- a) Supply of lift materials. b) Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing /altering civil works in lift entrance/pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, cutting pockets and grounding pockets for the guide rails, grouting boxes for control units, correction of wall opening in the front side of the wall by additional brick work or cutting existing brick work.c)Scaffolding.d) Door frames.e)Supporting steel.f)Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account.g)Intercom facilities with one master and two slaves.h) Battery operated alarm.i)Obtaining scheme approval as well as energization certificate from the electrical Inspectorate including preparation of necessary drawing for the same. Necessary fee shall remitted to the Inspectorate by the firm for which no refund will be made from the department including taking insurance for one vear as per new lift rule. j) Supply of book let with complete details of maintenance schedule and control diagram.k)Giving training to department staff for attending trouble shooting.l) Free servicing for 36 months after handing overitem2651Each
2664.1KSEB CHARGES FOR HT SUPPLY (Amount to be Reimbursed submition of Actual receipt)item2661L S
2675Fire Fighting and Fire Alarmitem267
2685.01Supply,installation and commissioning of Electrical fire fighting pumps of split case type with pressure gauge on delivery side & compound gauge on<br>suction side of 40HP, 2280 LPM 50m head, gland packed,stainless steel shaft high efficiency volute type with cast iron casing, bronze impeller, pump connected<br>with flexible stainless steel couplings to a squirrel cage induction motor totally enclosed fan cooled (TEFC) type of suitable HP, with a supply condition of 415V, 3 phase, 50 Hz, foot mounted type, including installation of all accessories as per the functional requirements of OEM.item2682Each
2695.02Supply,installation and commissioning of Diesel fire fighting pumps (stand by pump) of split case type of 38HP, 2280 LPM , 50m head, gland packed, stainless steel<br>shaft high efficiency volute type with cast iron casing,bronze impeller, pump connected with flexible couplings to a squirrel cage induction motor, 4Cylinder, water cooled with radiator cooling, vertical inline engine with a supply condition 12 V battery with rechargable adaptor, foot mounted type, including installation of all accessories, with Fuel Tank of storage capacity to run 8 hour continuosly complete with all interconnections with copper piping complete with all necessary accessories as requireditem2691Each
2705.03Supply, installation, testing & commissioning of electrically operated mono-block terrace pump of 7.5HP, 900 LPM@ 20m Head high efficiency volute type with cast iron casing, etc Totally Enclosed Fan Cooled (TEFC) type with a supply condition of 415V 50 Hz foot mounted typeitem2701Each
2715.04Supply, installation, testing and commissioning of jockey pump of inline vertical pump of 5HP,180 LPM 50m head, mechanical seals, stainless steel shaft high efficiency volute type with stainless steel casing,stainless steel impeller, pump connected with cross coupled to a squirrel cage induction motor totally<br>enclosed fan cooled (TEFC) type of suitable HP, with a supply condition of 415V, 3 phase, 50 Hz,including installation of all accessories as per<br>the functional requirements of OEM.item2712Each
2725.05Supply and providing Class C Heavy Duty MS pipe with all required specials and fasteners support etc complete of size 200mm.item272100Metre
2735.06Supply and providing Class C Heavy Duty MS pipe with all required specials and fasteners support etc complete of size 150mmitem273280Metre
2745.07Supply and providing Class C Heavy Duty MS pipe with all required specials and fasteners support etc complete of size 100mm.item274200Metre
2755.08Supply and providing Class C Heavy Duty MS pipe with all required specials and fasteners support etc complete of size 80mmitem275200Metre
2765.09Supply and providing Class C Heavy Duty MS pipe with all required specials and fasteners support etc complete of size 65mm.item276250Metre
2775.1Supply and providing Class C Heavy Duty MS pipe with all required specials and fasteners support etc complete of size 50mm.item277200Metre
2785.11Supply and providing Class C Heavy Duty MS pipe with all required specials and fasteners support etc complete of size 40mmitem278200Metre
2795.12Supply and providing Class C Heavy Duty MS pipe with all required specials and fasteners support etc complete of size 32mmitem279150Metre
2805.13Supply and providing Class C Heavy Duty MS pipe with all required specials and fasteners support etc complete of size 25mm.item280700Metre
2815.14Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)item2818Sqm
2825.15Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.item2820.2Sqm
2835.16Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheetitem28320Metre
2845.17Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)item2841Metre
2855.18Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.item285600Cum cm
2865.19Supply and providing copper earth bus in the panel boarditem286200Cum cm
2875.2Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.200A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SCitem2871Nos
2885.21Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OLitem2884Nos
2895.22Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SCitem2892Nos
2905.23Supply and Installation of following starter in the fire panel. DOL Starter for .25 to 7.5 HP Motoritem2903Each
2915.24Supply and Installation of following equipment in the fire panel. Soft Starter for 40HP motor.item2912Each
2925.25Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mmitem292600Metre
2935.26Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clampitem29330Metre
2945.27Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clampitem29430Metre
2955.28Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)item29512Set
2965.29Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)item2962Set
2975.3Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mmitem29715Metre
2985.31Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)item29812Set
2995.32Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)item29930Each
3005.33Supply and fixing of Control wiring with 1.5 sq.mm PVC insulated copper wire in the existing panels and giving connections as required.item30020Metre
3015.34Supply and fixing of 25 x 3 mm brass bolt with hexagonal/ square head, nut and washer.item30150Each
3025.35Supply and fixing of 12 x 3mm brass bolt with hexagonal/square head, nut and washeritem30250Each
3035.36SITC of Multifunction Metre to read V,A,F,3 Phase accuracy class 1.item3031Each
3045.37Supply and fixing of 100W PA Amplifier including accessories and giving connections as required.item3041Each
3055.38Supply and fixing of Microphone for intelligible, crisp and bright sound suitable for all types of PA applications supplied with quick detachable holder with 3 pin professional XLR connector & 6 mtrs, twin core shielded low noise cable.item3051Each
3065.39SITC of CO2 type fire extinguisher with 4.5kg capacity complete with installation brackets with ISI Mark IS 15222item3066Each
3075.4SITC of DCP type fire extinguisher with brackets and supports etc, 5 Kg.item30740Each
3085.41SITC of Double-headed Hydrant valve with stainless steel coupling 63mm dia confirming to IS 5290 with cap and chain as required.item30815Each
3095.42SITC of Hose Cabinet - Singleitem30915Each
3105.43SITC of Hose Reel confirming to IS 884 30mt longitem31015Each
3115.44Supply and fixing of CP Hose with accessories as required.item31115Each
3125.45SITC of Air Cushion Vessel made of mild steel of 250mm dia with automatic air release cock, 25mm dia drain valve and shut off. The vessel shall be 120cm in height. etc complete.item3121Each
3135.46SITC of Smoke detectors with solid stage design, indicating lamp, mounting base etc.item31345Each
3145.47SITC of Heat detectors with solid stage design, indicating lamp, mounting base, etc.item3144Each
3155.48SITC of single-acting Air Release Valve with screwed inlet 25mm dia.item3152Each
3165.49SITC of flow switch on sprinkler distribution header on each floor and shall be connected to the fire alarm panel.item3165Each
3175.5Supply and installation of the following sizes of cast iron Foot Valve with Strainer to the Pump Sets complete with Bolts, nut, and gasket if any as required.- 150mm diaitem3172Each
3185.51SITC of Butterfly Valve, 80mm diaitem3185Each
3195.52SITC of Butterfly Valve,100 mm diaitem3196Each
3205.53SITC of Butterfly Valve, 150mm diaitem3202Each
3215.54SITC of Non-Return Valve, 100mm diaitem3213Each
3225.55SITC of Non-Return Valve, 150mm diaitem3222Each
3235.56SITC of Branch pipe 63mm diaitem32315Each
3245.57Supply and fixing Pressure switch with IP32 enclosure protectionitem3244Each
3255.58Supply and fixing of Pressure gauge in the existing system as required.item3254Each
3265.59Supply and fixing of 4-way fire brigade inlet, 63mm dia.item3262Each
3275.6Supply and fixing of Up-right type Sprinkler Bulb having temparature rating of 68 deg. C complete as requireditem327259Each
3285.61Supply and fixing of Sprinkler bulb, Pendant type 20mm dia breakable at 68 degrees celcius.item32899Each
3295.62Supply and fixing of Manual call point break glass type with hammer and chain as required.item32915Each
3305.63Supply and fixing of Hooter for audio alarm as required.item33015Each
3315.64Supply and providing Glow Sign Boards of 3mm PVC foam board of size not less than 12''x4'' as required.item33148Each
3325.65Supply and providing Assembly point boards of 3mm PVC foam board size not less than 16''16'' as required.item3321Each
3335.66Supply and fixing Fire Escape Route size not less than 16''x16'' as required.item33310Each
3345.67Supply and Installation of control panel for fire system with display alarm etc complete with provision for public address as requied, 6 zone.item3341Each
3355.68SITC of LED Indicator lamps for 230/415V- red, green, orange color in the existing panel as requireditem3353Each
3365.69SITC of 200/5A, 5VA,Accurancy class 1,resin cast metering CTitem3361Each
3375.7Supply and fixing of 2 core 1 sq.mm audio cable for the PA system in the existing conduit, including giving connections as required.item337350Metre
3385.71Supply and fixing of fire alarm system copper cable, 2 Core 1.5 sq.mm along existing PVC conduit and giving connections as required.item338600Metre
3395.72Supply and Installation of 8W, 150mm ceiling-mounted speaker for PA system including giving connections as required.item33915Each
3405.73Supply and providing emergency fire escape lighting system consisting 2 nos lamp, 7AH battery charging unit, ext sign display etc in MS enclosure.item34063Each
3415.74Copying charges of Fire Drawings per A3 Sheet additional copies.item34190Each
3425.75Charges for preparation of Fire Drawings in A3 sheet first copy.item34215Each
3435.76Charges to be paid in the Fire Department for FIRE NOC. ( Actuals will be reimbursed upon producing original receipt)item3436000Sqm

AI Tender Summary

OUR REF NO 22298887
AUTHORITY Government Departments
TENDER VALUE 16.39 Crore
LAST DATE 21-11-2019
Authority
Authority Name Smart City Thiruvananthapuram Limited
Work Description Construction Of Multi Level Car Parking Cum Commercial Complex At Thampanoor Construction Of Multi Level 2 Wheeler And Car Parking Cum Commercial Complex At Thampanoor Thiruvananthapuram . The Project Comprises Of 5 Floors With Ground Floor For Four Wheeler Parking 1St 2Nd And 3Rd For Two Wheeler Parking And 4Th Floor Fo
Basic Detail
Tender No SCTL/PRJ/232/2019/MPMM/RFP/01
Bidding Type Tender
Location
City thiruvanthapuram
State Kerala
Key Dates
Publish Date 30 Oct 2019
Submission Date 21 Nov 2019
Open Date 23 Nov 2019
Finance
Tender Value 16.39 Crore
Tender Fee 15000
EMD 5 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
MLCPSCOPEOFWORK1.pdf
MLCPSCOPEOFWORK2.pdf
8ED27D24-CC29-4F8A-AAB0-D09C6EEB9FB2.html
contract.pdf
BOQ_432920.xls
itb.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 23, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

MLCPSCOPEOFWORK1.pdf

pdf

MLCPSCOPEOFWORK2.pdf

html

8ED27D24-CC29-4F8A-AAB0-D09C6EEB9FB2.html

pdf

contract.pdf

xls

BOQ_432920.xls

pdf

itb.pdf

Disclaimer