| 1 | 1 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm, FRLS PVC insulated, copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-B | BI01010001010000000000000515BI0100001113 | 4 | Points |
|---|
| 2 | 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCconduit as required i) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | BI01010001010000000000000515BI0100001116 | 20 | Mtr. |
|---|
| 3 | 3 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.i) 2 Pair | BI01010001010000000000000515BI0100001119 | 14 | Mtr. |
|---|
| 4 | 4 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.. (i) 20 MM | BI01010001010000000000000515BI0100001120 | 6 | Mtr. |
|---|
| 5 | 5 | Supplying and Fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. i) 180 mm X 100 mm X 60 mm deep | BI01010001010000000000000515BI0100001123 | 2 | Each |
|---|
| 6 | 6 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. i) 5/6 amps switch | BI01010001010000000000000515BI0100001124 | 4 | Each |
|---|
| 7 | 7 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required ii) 3 pin 5/6 amp socket outlet | BI01010001010000000000000515BI0100001125 | 4 | Each |
|---|
| 8 | 8 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required. | BI01010001010000000000000515BI0100001129 | 2 | Each |
|---|
| 9 | 9 | Supplying,installation,testing & commissioning of Wall mounted Fan 450 MM suitable for single phase AC, complete with all acessries connection etc as required. (Make-Crompton model WMHiFlo LG 18\" or its equivalent of Havells/Usha/Bajaj) | BI01010001010000000000000515BI0100001142 | 2 | Each |
|---|
| 10 | 10 | Supplying and fixing PVC batten/ angle holder along with inverter bulb of 09 Watt with 4 hours back up including connection etc. as required. Make- Anchor/Havells for holder and Halonix | BI01010001010000000000000515BI0100001199 | 2 | Each |
|---|
| 11 | 11 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required | BI01010001010000000000000515BI0100001152 | 2 | Each |
|---|
| 12 | 12 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | BI01010001010000000000000515BI0100001190 | 10 | Each |
|---|
| 13 | 13 | Supplying of 2 x 16 sq. mm XLPE insulated and PVC sheathed armored cable aluminium conductor 1.1 KV grade conf. to IS : 7098( Part 1)/ 1998 Havells/ L&T make | BI01010001010000000000000515BI0100001165 | 340 | Mtr. |
|---|
| 14 | 14 | Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Upto 35 sq. mm | BI01010001010000000000000515BI0100001169 | 240 | Mtr. |
|---|
| 15 | 15 | Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Upto 35 sq. mm | BI01010001010000000000000515BI0100001171 | 50 | Mtr. |
|---|
| 16 | 16 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. i) Upto 35 sq. mm | BI01010001010000000000000515BI0100001172 | 30 | Mtr. |
|---|
| 17 | 17 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. i) Upto 35 sq. mm | BI01010001010000000000000515BI0100001174 | 20 | Mtr. |
|---|
| 18 | 18 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of XLPE insulated and PVC sheathed aluminum conductor cable of 1.1 KV grade as required. i) 2 X 16 sq. mm(22mm) | BI01010001010000000000000515BI0100001178 | 4 | Each |
|---|
| 19 | 19 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required. i) 50 mm dia | BI01010001010000000000000515BI0100001183 | 30 | Mtr. |
|---|