| 1 | 1 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm, FRLS PVC insulated, copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-B | BI01010001010000000000000515BI0100001113 | 28 | Points |
|---|
| 2 | 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FRLS PVC insulated copper onductor single core cable for loop earthing as required. | BI01010001010000000000000515BI0100001114 | 20 | Mtr. |
|---|
| 3 | 3 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper onductor single core cable for loop earthing as required. | BI01010001010000000000000515BI0100001115 | 10 | Mtr. |
|---|
| 4 | 4 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCconduit as required i) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | BI01010001010000000000000515BI0100001116 | 77 | Mtr. |
|---|
| 5 | 5 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.i) 2 Pair | BI01010001010000000000000515BI0100001119 | 56 | Mtr. |
|---|
| 6 | 6 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.. (i) 20 MM | BI01010001010000000000000515BI0100001120 | 24 | Mtr. |
|---|
| 7 | 7 | Supplying and Fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. i) 75 mm x 75 mm x 60 mmm deep | BI01010001010000000000000515BI0100001122 | 8 | Each |
|---|
| 8 | 8 | Supplying and Fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.ii) 180 mm X 100 mm X 60 mm deep | BI01010001010000000000000515BI0100001123 | 16 | Each |
|---|
| 9 | 9 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. i) 5/6 amps switch | BI01010001010000000000000515BI0100001124 | 32 | Each |
|---|
| 10 | 10 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required ii) 3 pin 5/6 amp socket outlet | BI01010001010000000000000515BI0100001125 | 32 | Each |
|---|
| 11 | 11 | Supplying and Fixing following piano type switch/socket on the existing switch box/cover including connections etc as required. iii) Telephone socket outlet | BI01010001010000000000000515BI0100001127 | 8 | Each |
|---|
| 12 | 12 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.\n\n | BI01010001010000000000000515BI0100001128 | 4 | Each |
|---|
| 13 | 13 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required. | BI01010001010000000000000515BI0100001129 | 12 | Each |
|---|
| 14 | 14 | Supplying,installation,testing & commissioning of Wall mounted Fan 450 MM suitable for single phase AC, complete with all acessries connection etc as required. (Make-Crompton model WMHiFlo LG 18\" or its equivalent of Havells/Usha/Bajaj) | BI01010001010000000000000515BI0100001142 | 12 | Each |
|---|
| 15 | 15 | Supplying and fixing PVC batten/ angle holder along with inverter bulb of 09 Watt with 4 hours back up including connection etc. as required. Make- Anchor/Havells for holder and Halonix | BI01010001010000000000000515BI0100001199 | 16 | Each |
|---|
| 16 | 16 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) i) 6 way, Double door | BI01010001010000000000000515BI0100001147 | 5 | Each |
|---|
| 17 | 17 | Supplying and fixing 5 amps to 32 amps rating, 240 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i) Single Pole, 'C' series | BI01010001010000000000000515BI0100001149 | 20 | Each |
|---|
| 18 | 18 | Supplying and fixing 5 amps to 32 amps rating, 240 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ii) Single pole and neutral (32 amp) | BI01010001010000000000000515BI0100001150 | 5 | Each |
|---|
| 19 | 19 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required | BI01010001010000000000000515BI0100001152 | 4 | Each |
|---|
| 20 | 20 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | BI01010001010000000000000515BI0100001190 | 10 | Each |
|---|
| 21 | 21 | Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonary enclosure with cover plate, having locking arrangement and watering pipe etc. with charcoal or coke and salt as reqd. | BI01010001010000000000000515BI0100001153 | 5 | Set. |
|---|
| 22 | 22 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | BI01010001010000000000000515BI0100001154 | 10 | Mtr. |
|---|
| 23 | 23 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | BI01010001010000000000000515BI0100001155 | 40 | Mtr. |
|---|
| 24 | 24 | Supplying of 3.5 x 50 sq. mm XLPE insulated and PVC sheathed armored cable aluminium conductor 1.1 KV grade conf. to IS : 7098( Part 1)/ 1998 Havells/ L&T make | BI01010001010000000000000515BI0100001164 | 120 | Mtr. |
|---|
| 25 | 25 | Supplying of 2 x 16 sq. mm XLPE insulated and PVC sheathed armored cable aluminium conductor 1.1 KV grade conf. to IS : 7098( Part 1)/ 1998 Havells/ L&T make | BI01010001010000000000000515BI0100001165 | 600 | Mtr. |
|---|
| 26 | 26 | Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Upto 35 sq. mm | BI01010001010000000000000515BI0100001169 | 500 | Mtr. |
|---|
| 27 | 27 | Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 35 sq. mm and upto 95 sq. mm | BI01010001010000000000000515BI0100001170 | 90 | Mtr. |
|---|
| 28 | 28 | Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Upto 35 sq. mm | BI01010001010000000000000515BI0100001171 | 50 | Mtr. |
|---|
| 29 | 29 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. i) Upto 35 sq. mm | BI01010001010000000000000515BI0100001172 | 30 | Mtr. |
|---|
| 30 | 30 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. ii) Above 35 sq. mm and upto 95 sq. mm | BI01010001010000000000000515BI0100001173 | 10 | Mtr. |
|---|
| 31 | 31 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. i) Upto 35 sq. mm | BI01010001010000000000000515BI0100001174 | 20 | Mtr. |
|---|
| 32 | 32 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. ii) Above 35 sq. mm and upto 95 sq. mm | BI01010001010000000000000515BI0100001175 | 20 | Mtr. |
|---|
| 33 | 33 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of XLPE insulated and PVC sheathed aluminum conductor cable of 1.1 KV grade as required. i) 2 X 16 sq. mm(22mm) | BI01010001010000000000000515BI0100001178 | 4 | Each |
|---|
| 34 | 34 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of XLPE insulated and PVC sheathed aluminum conductor cable of 1.1 KV grade as required. iv)3½ X 50 sq. mm (32mm) | BI01010001010000000000000515BI0100001182 | 4 | Each |
|---|
| 35 | 35 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required. i) 50 mm dia | BI01010001010000000000000515BI0100001183 | 30 | Mtr. |
|---|
| 36 | 36 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required. ii) 100 mm dia | BI01010001010000000000000515BI0100001184 | 10 | Mtr. |
|---|
| 37 | 37 | SITC of outdoor type double door distribution panel made out of 2 mm thick CRCA Sheet of size 800 mm x 600 mm x 300 mm deep having 125 amp 4 nos aluminium bus bar and following accessories mounted thereon. The panel shall be openable from front side and also consists of angle iron frame of size 600 mm x 300 mm with 4 legs of 600 mm long made out of 35 x 35 x 4 mm thick angle iron. The inside and outside painting should be done with super quality Smoke grey synthetic enamelled paint with two or more coats. i) MCCB 4 pole 125 Amps 25 KA, 415 volts 50 Hz of L&T/ Havells/ Siemens/ C&S Make - 1 No ii) 63 Amps Double pole MCB 'C' Series 10 KA ( Make L&T/ Havells/ Siemens/ C&S ) - 4 Nos. iii) 63 Amps TPN MCB 'C' Series 10 KA ( Make L&T/ Havells/ Siemens/ C&S ) - 1 Nos. | BI01010001010000000000000515BI0100001186 | 1 | Each |
|---|