BOQ
| Name of Work: Provn of Solar security lights for every fifth pole of 167 MH, Online Continuous effluent monitoring system (OCEMS) and CCTV at 200 KLD MBBR type STP of Damtal, Geysers in Md Accn at 2 ASD and Certain revenue and minor works under GE(South) Pathankot. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | M&L for submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed. | 715 | RM | |
| 2 | 2 | M&L for submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed. | 350 | RM | |
| 3 | 3 | Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element,rust proof ABS body etc complete all as specified and directed. | 68 | Each | |
| 4 | 4 | Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed. | 68 | Each | |
| 5 | 5 | M&L for GI tubing medium grade of 15 mm dia with all fittings fixed to walls in concealed tubing and making good the surface with existing specifications complete all as specified and directed. | 145 | RM | |
| 6 | 6 | S&F PVC connection 15 mm size with PTMT nuts of length 450 mm ISI Marked complete all as specified and directed. | 136 | Each | |
| 7 | 7 | S&F angle valve, brass chromium plated screwed down high pressure with handle screwed both ends for iron pipe or for union of 15 mm dia of ISI Marked complete all as specified and directed. | 136 | Each | |
| 8 | 8 | S&F bib taps brass chromium plated with capstan head screwed down high pressure, with or without lettered Hot or Cold of size 15mm dia of ISI Marked complete all as specified and directed. | 68 | Each | |
| 9 | 9 | S&F distribution board sheet metal enclosure which is shock, rust, dust and impact proof, with internally embedded high grade gasket , double door with IP-54 1K-09 protection suitable for MCCB as incommer upto 100 Amps rating and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed. (Incoming MCCB and Outgoing MCB will be measured separately and paid seperately). | 6 | Each | |
| 10 | 10 | S&F MCCB 100 Amps current carrying capacity 16 KA , AC 415 Volts three pole complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections complete all as specified and directed. | 6 | Each | |
| 11 | 11 | Supply & Fix sheet metal enclosure DB's ( grouted in walls) double door type IP-43,1K-09 single pole and neutral for MCB's 08 ways with 200 Amps 240 volts rated bus bar complete all as specified and directed. | 44 | Each | |
| 12 | 12 | M&L 6 to 32 Amps MCB SP ( ISI Marked) 50 C/S 10 KA 'C' series complete all as specified and directed. | 264 | Each | |
| 13 | 13 | S&F MCB 6 to 32 Amp SPN 50 C/S 10 KA 'C' series complete all as specified all as directed. | 46 | Each | |
| 14 | 14 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for poles or laying of cables including getting out in any type of soil complete all as specified and directed. | 169 | Cum | |
| 15 | 15 | All as per item No 14 here in before but exc 1.5 mtr or part there of in depth beyond 1.5 mtr depth complete all as specified and directed. | 1 | Cum | |
| 16 | 16 | Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer in any type of soil complete all as specified and directed. | 105 | Cum | |
| 17 | 17 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 65 | Cum | |
| 18 | 18 | M&L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) complete all as specified and directed. Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid. | 43 | Cum | |
| 19 | 19 | Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed. | 4480 | Each | |
| 20 | 20 | Supply, laying, commissioning and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmmx 3.5 Core complete all as specified and directed. \nNote: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch. | 385 | RM | |
| 21 | 21 | Supply, laying, commissioning and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmmx 3.5 Core complete all as specified and directed. \nNote: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch. | 340 | RM | |
| 22 | 22 | Supply and fixing GI tubing light grade 40 mm dia size ISI marked with requisite fittings laid in trenches or crossing roads/paths/culverts/along poles/walls complete all as specified and directed. | 18 | RM | |
| 23 | 23 | Supply, installing, testing and commissioning of LT feeder pillar box factory made oudoor type, double door, slopy canopy, fabricated out of 3.15mm thick CRCA sheet with angle iron base frame made of 65 x 65 x 6mm ,45 cm height, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC duly powder coated after under going a rigorous metal treatment process of seven tank or nine tank process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete and including provn of the following:- Note: The panel shall be as per CPRI certificate. Note : PCC is deemed to be included in quoted rate :- (a) MCCB 4 pole 415 volts 3 phase 160 to 200 Amp 25 KA -01 No , Thermal magnetic release, Ics = 100% Icu and adjustable overload setting 80 % to 100%, (b) Two Nos spare compartments suitable for 160 Amps rated MCCB with busbar connections. (c) Digital Ammeter 0 to 1000 Amps rated, square type of size 96x96 mm, class 1.0, CT operated with selector switch. (d) Digital Voltameter 0 to 500 V , square type of size 96x96 mm, class 1.0 with selector switch.(e) Busbar links for cable connections. (f) TPN busbar of rating 300 Amps. (g) LED Indicator lamps R,Y,B -01 Set ( Set of three) | 4 | Each | |
| 24 | 24 | M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISImarked)of size 15mm for protection of GI earth wire 4 mm dia including PCC with 1:2:4 type B1 using 20mm graded crushed stone aggregate CI frame and cover of angle iron 40x40x6mm with lugs 2 nos and handle 6mm dia MS bar made to shape GI light grade20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, charcoal and common salt filling with fixing arrangment , funnel, wire meshand earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Metres , all as per electrical plate No- 3 of SSR Pt -I to earth test point all as speciied or indicated including testing on completion complete all as specified and directed. | 21 | Each | |
| 25 | 25 | Material and labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing) complete all as specified and directed. | 6 | Each Set | |
| 26 | 26 | M&L for Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 matching with the surroundings complete all as specified and directed. | 1 | Cum | |
| 27 | 27 | Material, labour, testing & commissioning of cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 sqmm 3½ or 4 core with working voltage 1100 volts complete all as specified and directed. | 5 | Each | |
| 28 | 28 | Material, labour, testing & commissioning of cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 70 Sqmm to 150 sqmm 3½ or 4 core with working voltage 1100 volts complete all as specified and directed. | 6 | Each | |
| 29 | 29 | M&L for point wiring with PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge (Phase Neutral and earth wire shall be provided in standard colour code R,Y,B for phase, Black for neutral green for earth wire). \nNote In ceiling Portion surface conduit wiring shall be carried out. \n | |||
| 30 | 30 | One fan point or bell point controlled by one switch SP one way 230 Volts. | 2 | Per \nPoint | |
| 31 | 31 | M&L for switch Piano flush type single pole one way 5/6 Amp complete all as specified and directed. | 2 | Each | |
| 32 | 32 | M&L for ceiling rose 2-3 terminal size 65x20mm complete all as specified and directed. | 2 | Each | |
| 33 | 33 | S&F Ventilation fan AC sinlge phase 230/240 volts of size 250 mm sweep having plastic body with louvre including connecting to ceiling rose complete all as specified and directed. | 2 | Each | |
| 34 | 34 | Supply, laying, commissioning and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmmx 4 Core complete all as specified and directed. \nNote: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch. | 43 | RM | |
| 35 | 35 | Supply & fixing Solar smart intergreted Solar LED Street light fitting (All in one type) with built in Mono Crystalline Panel, lithium ion battery (LiFePO4), MPPT charger controller, PIR sensor with colour temp 600-6500 K with minimum 40 W capacity LED light fittings with hybrid switch, Mono crystalline solar panel of capacity 48W+ 4W (mono), PIR sensor, IP65, 12.8V, 27 Ah lithium ion (LiFePo4) battery inbuilt in fitting, MPPT charge controller with efficiency > 90%, CRI > 70, autonomy for minimum 2 days, charging time 1 day, suitable for working temperatures -10 Degree C to +55 Degree C, fixed on 9.0 meter steel tubular pole/RCC pole complete all as directed & specified. Note: The rate is inclusive of fitting, battery, controller etc complete. The GI pipe bracket along with clamps, steel tubular pole and PCC foundation will be measured and paid separately. | 14 | Each | |
| 36 | 36 | M&L for bracket for street light fitting made out of 50 mm bore pipe light grade GI tube 1.2 Meter length bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and directed. | 14 | Each | |
| 37 | 37 | Supply and erection in vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (9.00 metres long) all as specified duly factory painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required all as specified and directed.Note : PCC in foundation, coping, Earth work ( Excavation, Returning & refilling and removal) will be measured and paid separately under relative items of Schedule. | 9 | Each | |
| 38 | 38 | M&L for Plain cement concrete (1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as in foundation for poles mass concretes or in any indicated positions etc complete all as specified and directed. | 11 | Cum | |
| 39 | 39 | M&L for Plain cement concrete (1:2:4) type B-1 (Using 20 mm graded stone aggregate) for coping of poles including form work complete all as specified and directed. | 1 | Cum | |
| 40 | 40 | M&L for GI pipe light grade 50 mm dia with all fittings for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection complete all as specified and directed. | 9 | RM | |
| 41 | 41 | Supply, install, testing & commissioning of ONLINE WATER QUALITY MONITORING ANALYZER (ONLINE CONTINUOUS EFFLUENT MONITORING SYSTEM) all as per CPCB & PPCB norms for 200 KLD MBBR type STP at Damtal(9 Core ZW) with following specifications all as specified and directed. Model: UV300 Make: Tethys Instruments or equivalent approved by PPCB/CPCB\n | 1 | Each Job | |
| 42 | 42 | (a) COD, BOD & TSS measurement by UV absorbance method\n(Sample scan between 180 to 800nm), (b) pH measurement by electrochemical method, (c) Power Supply: 90-264 VAC 50/60 Hz, (d) Screen: Colour TFT LCD 640 X 480 pixels with LED backlight,resistive touch screen and with touch screen display. (e) Enclosure: Stainless steel with epoxy coating, IP65, (f) Measurement Range: COD: 0 - 500 ppm,(g) BOD: 0 - 200 ppm,(h) TSS: 0 - 1500 ppm (j)pH: 0 - 14. (k) Flow Meter: Upto 1” line size (l) 5 Years year Software plan Included in quoted rate with the following scope:\n(i) Design, engineering & amp; supply for the quoted system as per the technical specification and as per CPCB/State Pollution Board (PPCB) guidelines .(ii) Power for AC powered hardware where required. (iii) Internet connectivity up to Analyzer. (iv) Sample Line up to Analyzer \n(v) Lab inspection, report of sample.(vi) Supply, laying, testing & commissioning of Cable complete as per site requirement for commisioning the equipment and making it operational alongwith necessary cable tray/ fabrication etc complete\n | |||
| 43 | 43 | Note: The quoted rate shall be deemed to be inclusive of the following :- | |||
| 44 | 44 | (a) The system should comply all the clauses mentioned in the directions given by CPCB/ State PPCB and \" THE WATER(PREVENTION AND CONTROL OF POLLUTION) ACT, 1974 AND AMENDMENTS THEREON \" .(b) The requirement for Online Effluent Quality Monitoring Station (OCEMS) shall be suitable for measurements of BOD, COD, pH and TSS. OCEMS station should have facility to communicate real time measurement data of all parameters as described in detail in the following section to State PCB (PPCB) & CPCB.(c) The necessary sample, power supply and drain port near analyzer location shall be provided at STP Damtal.\n(d). The quoted rate inclusive of complete set up and system required for provision of RS232 or RS485 output port with further data transfer from Analyzer to State PCB (PPCB) & CPCB. \n | |||
| 45 | 45 | The complete detailed specification of Online Effluent Quality Monitoring Station (OCEMS) as per mentioned below:- | |||
| 46 | 46 | (a) Analyzer Type : Cabinet Type & Multi – Parameter (b) Make & Model : Model: UV300 Make: Tethys Instruments or equivalent approved by PPCB/CPCB.(c) Measuring Principle : COD, BOD & TSS measurement by UV absorbance method (Sample scan between 180 to 800nm) & pH measurement by electrochemical method. (d) Measuring Range :COD: 0 – 500 mg/l,BOD: 0 – 500 mg/l , TSS: 0 – 1500 mg/l,pH 0 to 14.(e) Operating pressure,Temperature & Flow : To be specified/confirmed by OEM/tenderer.(f) Flow Cell Diameter – minmum and above 10 mm. (g) Enclosure protection: IP65, stainless steel with epoxy coating. (h) Communication : RS232 or RS485 output. USB port required for USB / pen drive connection. (j) Memory: 5000 records with date and time. (k) Display: Color TFT, LCD, LED backlight Resistive touch screen. It should have touch screen display. (l) Measuring time / Response time: 5 Sec\n(m) Measuring Cycle: Continuous | |||
| 47 | 47 | (n Power Supply: 90 – 264 VAC 50/60 Hz. UPS of minimum 880 VA capacity with 12 V 200 AH tubular battery shall be provided and quoted rate is deemed to be included in quoted rate.All control/power cables along with cable tray, terminations, laying, testing & commissioning is deemed to be included in the quoted rate. \n(p) Cleaning Method : Automatic, Analyzer should have facility to start cleaning cycle automatically as per user defined time interval\n(q) Calibration requirement\n(i) Zero Calibration: Should have auto zero calibration facility,\nAnalyzer should have facility to start auto zero calibration as per\ndefined time interval.\n(ii) Span Calibration: Should be perform as per laboratory\nmeasurement data.\n(r) UV Light Source: Xenon Flash Lamp having life more than 10 years. (r) USB Port: Analyzer should have USB port for download store measurement data. | |||
| 48 | 48 | (s) Multiplexing Facility: Analyzer should have built-in multiplexing facility to add various sample stream minimum up to six – which allow user to connect additional sample stream to meet future compliance requirement, if any, without any cost.(t) Expandability of measurement :(i) Analyzer should have capability to add parameters like Color and other parameters as below:\ni. Oil in Water : Measurement Technique by UV Fluorescence\nii. Chlorine: by Colorimetertric measurement.\niii. TDS, Conductivity, ORP: Electrochemical Sensor\niv. Dissolved Oxygen: Measurement Technique – Optical\n(u) Additional Requirement: Should have robust flow cell which allows very high level of suspended solid without clogging and also suitable for highly corrosive effluent water. | |||
| 49 | 49 | The System should comply with the following:- | |||
| 50 | 50 | (a) Should provide continuous measurement of data for long period of time, at the\nmonitoring site of interest, without skilled staff being required to perform the analysis.(b) All the major steps in traditional analysis like sample collection, preservation,transportation, sample pre – treatment, calibration, reagent addition and sample analysis procedures should be automated.(c) In case of sudden disturbance in the system, compared to conventional methods the on-line analyzer should provide timely information for taking immediate corrective /preventive steps.\n(d). Should be capable of operating unattended over prolonged period of time.(e) Should produce analytically valid results with precision and repeatability. | |||
| 51 | 51 | (f) Should be robust and rugged, or optimal operation under extreme environmental conditions, while maintaining its calibrated status.\n(g) Should have data validation facility with features to transmit raw and validated data to central server.’\n(h) Should have Remote system access from central server provisioning log file access.\n(j) Should have provision for Multi-server data transmission from each station without intermediate PC or plant server.\n(k) Should have provision to send system alarm to central server in case any changes made in configuration or calibration.\n(l) Should have provision to record all operation information in log file.\n(m) For each parameter there should be provision for independent analysis, Validation, Calibration & data transmission. | |||
| 52 | 52 | (n) Must have provision of a system memory (non-volatile) to record data for at least on year of continuous operation.\n(p). Should have provision of plant level data viewing and retrieval with selection of Ethernet, wireless, Modbus & USB.\n(q) The correlation / interpretation factor for estimating COD and BOD using UV- visible Absorption Technique shall be regularly authenticated / validated and details provided.\n(r) Record of calibration and validation should be available on real time basis on central server from each location / parameter.\n(s) Record of online diagnostic features including sensor status should be available in database for user friendly maintenance.\n(t) Expandable program to calculate parameter load daily, weekly or monthly basis for future evaluation with flow rate signal input.\n(u) Parameter Validation: Each parameter should be validated with reference to standard laboratory analysis from PBTI (Punjab Biotechnology Incubator) Lab or PPCB Lab as directed , and known standards.The quoted rate inclusive for the same.\n(v) Parameter Allowed Variability: The relative difference between online and laboratory measurements has to be between.\na. COD Accuracy + 10%\nb. BOD Accuracy + 10%\nc. pH Accuracy + 0.2 pH\nd. TSS Accuracy +/- 10% | |||
| 53 | 53 | Reporting: The ONLINE CONTINUOUS EFFLUENT MONITORING SYSTEM) supplier/ tenderer have to provide link with central server at CPCB and State PCB (PPCB) with latest software to view the data in graphical / tabular format as per suitability and also to compare the date features. One minute date average must be transmitted / retrieved to servers every 30 minutes. In the event of transmission loss the time stamped data in the data logger memory must be transmitted to fill form the last transmission break with a stamp of time delay. The software should have two way communications, so that data from the system can be seen whenever desired and remote of controller/data logger can be taken to visualize the immediate status of the system. | |||
| 54 | 54 | Data Management: Considering the heterogeneity of real time monitoring systems, real time data should be submitted to CPCB and State PCB (PPCB) as per their requirement by supplier/tenderer.\ni. The software should give alarm, in case of the concentration of parameter exceeds the prescribed norms by 10% continuously.\nii. The supplier should facilitate data transmission on behalf of STP Damtal of GE(South) Pathankot. The supplier should ensure at least 85% data availability from the system installed. iii. The supplier shall link with server of PPCB / CPCB for transferring data from the real time system. iv. The supplier shall make provisions to provide data continuously at least 04 locations in State PCB (PPCB), RO/DO of CPCB and to Department as directed directly from the analyzers.\nv. In case of system requiring pumping of samples, the supplier /tenderer has to ensure that dilution of sample is not possible and in case of any dilution, the system gives alarm.\nvi. The supplier should regularly cross check the data obtained from real time system with that of the samples collected manually and analyze/test the sample from PBTI (Punjab Biotechnology Incubator) Lab or PPCB Lab as directed and revalidate the factor for interpolation / extrapolation of COD/ BOD values essential for generating better quality data. The supplier / tenderer should take responsibility of establishing co-relation factor. | |||
| 55 | 55 | (i) Certificate : The analyzer should have TUV/MCERT/USEPA\nCertification. (ii) CE Certificate : CE, EN61010-1, EN61326. (iii) Compliance to International Standards & Methods: Standard Method 5910 (Standard methods for the examination of water and waste water) DIN 38404 C3\n(iv) Standard supply :(a) Analyzer for the measurement of COD, BOD, TSS & pH, (b) Free Standing panel. (c) Sample pump, (d) upto120 meter sample tubing for drawing sample up to\nanalyzer pump, (e) PC for plant with necessary software for data acquisition and storage, (f) Data acquisition system with software for transmission of data to CPCB & State PCB (PPCB).(g)Operation & Maintenance manual. (h) Manufacturer test certificate.\n | |||
| 56 | 56 | Warranty for a period of 3 years from the date of\ncommissioning including minimum one service visit for every four months excluding breakdown calls. \n | |||
| 57 | 57 | Delivery One month from the date of receipt of work order/ acceptance and erection One month from the date of supply of equipment and\ncompletion of prerequisites as per norms of PPCB/CPCB complete.\n | |||
| 58 | 58 | Commissioning 15 days from the date of completion of erection | |||
| 59 | 59 | The total job shall be completed in all respects within three months of period. Any delay may lead to penalty charges in the form of FDR from PPCB and the same shall be beared by the tenderer on no cost basis without any claim from department. The Contractor shall submit 3% FDR in addition to performance gaurantee before acceptance in regard of timely completion of job as per norms of PPCB/CPCB | |||
| 60 | 60 | The rate quoted deemed to be inclusive of Supply & laying of 10mm sample line with min 1 bar pressure up to Analyzer,Supply, installation & laying of UPS & UPS power supply cable up to Analyzer,Drain facility near Analyzer,Necessary arrangement for mounting of Analyzer,Any Civil/ Structural/ Fabrication, Modem & other connected accessories complete as per CPCB/PPCB norms . | |||
| 61 | 61 | Supply, install, testing and commissioning of MCCB 3 Pole, 415 V, fixed type, 12 to 63 Amps with breaking capacity 16 KA in sheet steel enclosure complete all as specified and directed. | 1 | Each | |
| 62 | 62 | Fixing , installing, testing and commissioning of security survelliance (CCTV) system consisting of the following :-\na) Night Vision Indoor HD 2.0MP Dome Camera, 20 Mtrs IR, 3.6MM (Including complete Accessories) -01 Set.(b) Night Vision Outdoor 2.0MP HD Bullet Camera, 30 Mtrs IR, 3.6MM (Including complete Accessories) -02 Set.(b) Co-axial CCTV Copper Cable with 2 Core DC Power Cable - Approx 125 Rm. (c) CONDUIT PVC Pipe/PVC Casing/HDPE Conduit Pipe with all accessories - Approx 125 RM.(d) CCTV 08 CH Power Supply with Voltage Controller & Surge Protector -01 Set.(e) 4 CH 2.0MP HD Digital Video Recorder, 1 Sata support Upto 6 TB, Mobile & Remote Monitoring system -01 Set. (f) CCTV 1 Tera Byte Surveillance Grade Hard Disk -01 Nos. (g) CCTV-UPS with Auto Power Restart & Inbuilt Battery -01 Set (h) 18.5\" LED Monitor With HD Reoslution -01 Set (j) CCTV Rack 4U with 250MM Tray, Cooling Fan & Power Manager -01 set (k) wireless mouse for DVR/NVR (USB to USB cable) -01 Set | 1 | Each\n Job | |
| 63 | 63 | Note : (a) The quoted rate inclusive of conduit PVC pipe/ casing/HDPE conduit, necessary T&P, connecting items such as ferrules/lugs,insulation tape etc. | |||
| 64 | 64 | Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender