Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #22272392

Internal And External Electrification Of Wsa Cafeteria With Pc Dingaamb Kathua Internal And External Electrification Of Wsa Cafeteria With Pc Dinga Amb Kathua

Issued by Local Bodies · KATHUA, Jammu And Kashmir
Tender Value
5.12 Lakhs
Estimated cost
Bid Submission
30 Oct 2019
0 days left
EMD
10240
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
KATHUA → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Internal And External Electrification Of Wsa Cafeteria With Pc Dingaamb Kathua Internal And External Electrification Of Wsa Cafeteria With Pc Dinga Amb Kathua

BOQ

Name of Work:- INTERNAL & EXTERNAL ELCTRIFICATION OF WSA(cafeteria with PC) DINGAAMB, KATHUA
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Point wiring in PVC conduit with modular type switch point with 1.5sqmm wiring for light point/fan point/call bell point with 1.5 sqmm FRPVC insulated copper conductor cable in recessed/surface with modular type switch, modular plate and earthing the point with 1.5 sqmm FRPVC,insulated copper conductor single core cable etc. as required . (anchor,havells,v-guard) Group a10pt
22Point wiring in PVC conduit with modular type switch point with 1.5sqmm wiring for light point/fan point/call bell point with 1.5 sqmm FRPVC insulated copper conductor cable in recessed/surface with modular type switch, modular plate and earthing the point with 1.5 sqmm FRPVC,insulated copper conductor single core cable etc. as required . (anchor,havells,v-guard) Group b25pt
33Point wiring in PVC conduit with modular type switch point with 1.5sqmm wiring for light point/fan point/call bell point with 1.5 sqmm FRPVC insulated copper conductor cable in recessed/surface with modular type switch, modular plate and earthing the point with 1.5 sqmm FRPVC,insulated copper conductor single core cable etc. as required . (anchor,havells,v-guard) Group c30pt
44Wiring for circuit/sub main along with earth wire wit following sizes of FRPVC insulated copper conductor ,single core cable in surface/recessed medium class PVC conduit as required(anchor,havells,v-guard) 2x2.5sqmm+1x2.5sqmm earth wire200RMT
55Wiring for circuit/sub main along with earth wire wit following sizes of FRPVC insulated copper conductor ,single core cable in surface/recessed medium class PVC conduit as required(anchor,havells,v-guard) 2x4 sqmm+1x4 sqmm earth wire150RMT
66Supplying and fixing following size/modular GI box along with modular base and cover plate for modular switches in recess etc. required(anchor,havells,v-guard)\n3 modules(100mm*75mm)\n20Nos
77Supplying and fixing following size/modular GI box along with modular base and cover plate for modular switches in recess etc. required(anchor,havells,v-guard)\n6 module(200mm*75mm)\n10Nos
88Supplying and fixing following size/modular GI box along with modular base and cover plate for modular switches in recess etc. required(anchor,havells,v-guard) 12 module(200mm*150mm)\n10Nos
99Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc.as required 5/6 amp swit (anchor,havells,v-guard\n20Nos
1010Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc.as required 15/16 amp. Switch (anchor,havells,v-guard\n18Nos
1111Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc.as required 3 pin 5/6 amp socket outlet (anchor,havells,v-guard\n20Nos
1212Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc.as required 6 pin 15/16 amp socket outlet (anchor,havells,v-guard\n18Nos
1313Supplying and fixing stepped type electronic fan regulator in the existing modular plate switch box including connection but excluding modular plate etc. as required(anchor,havells,v-guard10Nos
1414Supplying and fixing modular blanking plate on the existing modular plate and switch box20Nos
1515Supplying and fixing of single pole and neutral,sheet teel,MCB distribution board,240 volt on the surface/recess complete with tinned cippler bus bar,neutral bus bar,earth bar din bar,inter connection,powder painted including earhting as required \n2+ 12way ,single door(anchor,havells,v-guard\n4Nos
1616Supplying and fixing 5 Amp to 32 Amp rated 240/415 volt c curve miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commission etc. as required. Single pole24Nos
1717Supplying and fixing 5 Amp to 32 Amp rated 240/415 volt c curve miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commission etc. as required. Double pole(anchor,havells,v-guard4Nos
1818Earthing with copper earth plate 600mm*600mm*3mm thick including 25mm *5mm copper strip on surface or in recesses for connection, accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc.wit charcoal /coke and salt as required3Nos
1919Supplying and fixing of ,noiseless with heavy duty motor,metallic body, 3 blade exhaust fan of 230 mm ,including ceiling rose for connection as per site requirement ISI mark,Crompton, havell,usha,bajaj2Nos
2020Supplying and fixing of ceiling fan with motor speed of 380 rpm,power consumption of 78watt,number of speed settings 5,white colour,1200mm blade sweep as per site requirement ISI mark havell,usha,bajaj10Nos
2121SITC of pvc insulated and pvc sheathead XLPE aluminium armoured underground single core cable of 16 sqmm for each phase R,Y,B(anchor,havells,v-guard150Nos
2222SITC of insulated piercing connector (IPC) for taking connection from phase and neutral underground cable30Nos
2323SITC of galvanized tubular 05 meter pole of 4.8mm thick,80mm (3 inch) diameter from base of pole to 3 meter up ward and 2.5 inch diameter from 3meter to top of pole along with base plate of MS sheet of 8mm thick with four numbers of appropriate hole for fixing G.I pole with foundation bolts,fitted with 150 watt led street light,Including cost of pvc insulated pvc sheathed XLPE aluminium armoured underground single core cable of 16 sqmm cable for each phaseR,Y,B, including excavation of size (.9m*.9m*1m) reinforced cement concrere 1:2:4(cement:coarse sand:graded stone),centerin and shuttering uoto plinth level,steel reinforced of diameter 12mm,length 90cm of 20 kg and backfilling,including chemical earthing of each pol etc. as per site requirement, DP/SPN of 10-32 amp and DB box for each pole,2.5 SQM double core copper cable and other change of requirement as direction of engineer incharge and charges as per site requirement.\nMake of pole jindal,parkash,surya,vardhman,oswal\nMake of cable anchor,havells,v-guard\nMake of light wipro,havells,bajaj\n10Nos
2424SITC of galvanized tubular 1.5 meter pole of 4.8mm thick,50mm (2 inch) diameter from base of pole to top of pole along with base plate of MS sheet of 6mm thick with four numbers of appropriate hole for fixing G.I pole with foundation bolts,fitted with,fitted with 25 watt yellow ornamental light , Including cost of pvc insulated pvc sheathed XLPE aluminium armoured underground single core cable of 10 sqmm cable for each phaseR,Y,B, chemical earthing of each pole , excavation of size (.45m*.45m*.5m) reinforced cement concrere 1:2:4(cement:coarse sand:graded stone),centerin and shuttering uoto plinth level,steel reinforced of diameter 12mm,length 90cm of 10 kg and backgfilling,including chemical earthing of each pol etc. as per site requirement,DP/SPN of 10-32 amp and DB box for each pole, 2.5 SQM double core copper cable and other change of requirement as direction of engineer incharge and charges as per site requirement.\nMake of pole jindal,parkash,surya,vardhman,oswal\nMake of cable anchor,havells,v-guard\nMake of light wipro,havells,bajaj\n20Nos
2525SITC of pvc insulated aluminium single core cable of 10 sqmm for each phase (anchor,havells,v-guard100Mtr
2626SITC of 18 WATT white colour ,4feet led tube as per site requirement ISI mark syska,havell,usha,bajaj22Nos
2727SITC of round white /yellow led concealed light of 5watt along with concealed box as per site requirement ISI mark Philips ,havell,,bajaj30Nos

AI Tender Summary

OUR REF NO 22272392
AUTHORITY Local Bodies
TENDER VALUE 5.12 Lakhs
LAST DATE 30-10-2019
Authority
Authority Name Lakhanpur-Sarthal Development Authority
Work Description Internal And External Electrification Of Wsa Cafeteria With Pc Dingaamb Kathua Internal And External Electrification Of Wsa Cafeteria With Pc Dinga Amb Kathua
Basic Detail
Tender No e- NIT No 09 of 2019-20
Bidding Type Tender
Location
City KATHUA
State Jammu And Kashmir
Key Dates
Publish Date 26 Oct 2019
Submission Date 30 Oct 2019
Open Date 31 Oct 2019
Finance
Tender Value 5.12 Lakhs
Tender Fee 1000
EMD 10240
Exemption Not Available
Document List
396B14CD-6EA1-4B5F-921C-6782512018D3.html
BOQ_157552.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 01, 1900
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 31, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

396B14CD-6EA1-4B5F-921C-6782512018D3.html

xls

BOQ_157552.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders