}

Rendering Services For Operation And Maintenance Of Central Ac Plant , Including Allied Services At 3 Ac , 4 Ac And 5 Ac Plant Inside Depot Area At Aa Banar , Rendering Services For Operation/ Effective Functioning And Upkeeping Of Central Ac Plant 150 Tr Capacity With Stand By Dg Set 380 Kva And Indoor Substation With 500 Kva Transformer And Ocb Of 400 Amp Capacity , Ac Plant Comprising Of 3 Nos Compressor Unit Each Not Less Than 75 Ton Two Units To Work At A Time One Unit As Relief Cum Standby , Condensor And Chillers Water Pump Sets , Cooling Towers Two Nos , Control Panels , Make Up Tank , Chiller Water Line , Ahu And Connected Ducting System In Each Building For Storage Accn Msl Shed 1 To 5 Of 2 Ac And 3 Ac Inside Depot Area In Three Shift Per Day ( Each Shift Of 8 Hrs ) To Maintain The Desired Inside Condition Of Sheds , Security Thereof Round The Clock And Maintain Record Of Daily Operation And Upkeeping Works All As Directed By Eng-In-Charge . Note: The Operat, BANAR-Rajasthan

Military Engineer Services has published Rendering Services For Operation And Maintenance Of Central Ac Plant , Including Allied Services At 3 Ac , 4 Ac And 5 Ac Plant Inside Depot Area At Aa Banar , Rendering Services For Operation/ Effective Functioning And Upkeeping Of Central Ac Plant 150 Tr Capacity With Stand By Dg Set 380 Kva And Indoor Substation With 500 Kva Transformer And Ocb Of 400 Amp Capacity , Ac Plant Comprising Of 3 Nos Compressor Unit Each Not Less Than 75 Ton Two Units To Work At A Time One Unit As Relief Cum Standby , Condensor And Chillers Water Pump Sets , Cooling Towers Two Nos , Control Panels , Make Up Tank , Chiller Water Line , Ahu And Connected Ducting System In Each Building For Storage Accn Msl Shed 1 To 5 Of 2 Ac And 3 Ac Inside Depot Area In Three Shift Per Day ( Each Shift Of 8 Hrs ) To Maintain The Desired Inside Condition Of Sheds , Security Thereof Round The Clock And Maintain Record Of Daily Operation And Upkeeping Works All As Directed By Eng-In-Charge . Note: The Operat. Submission Date for this Tender is 01-11-2019. Industrial Gases Tenders in BANAR Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

22198261
Rendering Services For Operation And Maintenance Of Central Ac Plant , Including Allied Services At 3 Ac , 4 Ac And 5 Ac Plant Inside Depot Area At Aa Banar , Rendering Services For Operation/ Effective Functioning And Upkeeping Of Central Ac Plant 150 Tr Capacity With Stand By Dg Set 380 Kva And Indoor Substation With 500 Kva Transformer And Ocb Of 400 Amp Capacity , Ac Plant Comprising Of 3 Nos Compressor Unit Each Not Less Than 75 Ton Two Units To Work At A Time One Unit As Relief Cum Standby , Condensor And Chillers Water Pump Sets , Cooling Towers Two Nos , Control Panels , Make Up Tank , Chiller Water Line , Ahu And Connected Ducting System In Each Building For Storage Accn Msl Shed 1 To 5 Of 2 Ac And 3 Ac Inside Depot Area In Three Shift Per Day ( Each Shift Of 8 Hrs ) To Maintain The Desired Inside Condition Of Sheds , Security Thereof Round The Clock And Maintain Record Of Daily Operation And Upkeeping Works All As Directed By Eng-In-Charge . Note: The Operat
Open Tender
NCB
Rajasthan
Banar
01-11-2019

Tender Details

Corrigendum - Rendering Services For Operation And Maintenance Of Central Ac Plant , Including Allied Services At 3 Ac , 4 Ac And 5 Ac Plant Inside Depot Area At Aa Banar , Rendering Services For Operation/ Effective Functioning And Upkeeping Of Central Ac Plant 150 Tr Capacity With Stand By Dg Set 380 Kva And Indoor Substation With 500 Kva Transformer And Ocb Of 400 Amp Capacity , Ac Plant Comprising Of 3 Nos Compressor Unit Each Not Less Than 75 Ton Two Units To Work At A Time One Unit As Relief Cum Standby , Condensor And Chillers Water Pump Sets , Cooling Towers Two Nos , Control Panels , Make Up Tank , Chiller Water Line , Ahu And Connected Ducting System In Each Building For Storage Accn Msl Shed 1 To 5 Of 2 Ac And 3 Ac Inside Depot Area In Three Shift Per Day ( Each Shift Of 8 Hrs ) To Maintain The Desired Inside Condition Of Sheds , Security Thereof Round The Clock And Maintain Record Of Daily Operation And Upkeeping Works All As Directed By Eng-In-Charge . Note: The Operator Will Be Responsible For Running Of Fire Fighting Installations At 3 Ac Area Including Six Nos Centrifugal/Submersible Pumps Sets Of Any Capacity Including Running Of Shallow Well Submersible Pump Sets For Fire Fighting Sump As And When Required . The Operator Will Also Be Responsible For Checking Of Fire Hydrants With Users With Proper Supply Of Water To Fire Hydrants In 2 Ac , 3 Ac Area . ( 3 Ac , Ac Plant ) , Rendering Services For Operation/ Effective Functioning And Upkeeping Of Central Ac Plant 200 Tr Capacity With Stand By Dg Set 500 Kva And Indoor Substation With 630 Kva Transformer And Vcb Of 400 Amp Capacity , Ac Plant Comprising Of 3 Nos Compressor Unit Each Not Less Than 100 Ton Two Units To Work At A Time One Unit As Relief Cum Standby , Condensor And Chillers Water Pump Sets , Cooling Towers Two Nos , Control Panels , Make Up Tank , Chiller Water Line , Ahu And Connected Ducting System In Each Building For Storage Accn Msl Shed 6 To 9 Of 3 Ac Inside Depot Area In Three Shift Per Day ( Each Shift Of 8 Hrs ) To Maintain The Desired Inside Condition Of Sheds , Security Thereof Round The Clock And Maintain Record Of Daily Operation And Upkeeping Works All As Directed By Eng-In-Charge . ( 4 Ac , Ac Plant ) , Rendering Services For Operation/ Effective Functioning And Upkeeping Of Air Cooled Central Ac Plant 60 Tr Capacity With Stand By Dg Set 60 Kva And Indoor Substation With 250 Kva Transformer And Vcb Of 400 Amp Capacity , Ac Plant Comprising Of 3 Nos Compressor Unit Each Not Less Than 30 Ton Two Units To Work At A Time One Unit As Relief Cum Standby , Condensor And Chillers Water Pump Sets , Control Panels , Chiller Water Line , Ahu And Connected Ducting System In Each Building For 5 Ac Inside Depot Area In Three Shift Per Day ( Each Shift Of 8 Hrs ) To Maintain The Desired Inside Condition Of Sheds , Security Thereof Round The Clock And Maintain Record Of Daily Operation And Upkeeping Works All As Directed By Eng-In-Charge . , Rendering Services For Operation/ Effective Functioning & Up Keeping Of Static Fire Fighting Water Distribution System Of Pocket ( A ) 3 Ac , Msl Sheds Of 4Ac , Pinaka Complex , Smerch Complex , Amn Disposal Area , Akash Complex Area At Inside Depot Area Fad , Aa Banar Under Ge Banar In One Shift Of Eight Hours As Per Schedule Provided / As Directed Time To Time By Engr In Charge For Distribution Of Water And For Rectification Of Complaints In The Area . , Rendering Services Person Shall Be Liaise With Pump Houses For Smooth Functioning Of Distribution System . , Note For Item No 1 To 4 :- , ( I ) Cleaning Of Complete Ac Plant I . E Cleaning Of Chiller Unit , Pump , Motor And Pipe Lines , Electric Panels Board Surrounding Area Of Plant Daily And Cleaning Of Complete Ahu Room , Cleaning Of Supply And Return Grill , Cleaning Of Cooling Tower ( On Monthly Basis ) , ( Ii ) Monitoring And Controlling Of All Refrigent Control System To Achieve Desired Inside Temperature And Pressure Of Water And Refrigerent Gas . , ( Iii ) Monitoring And Operation Of All Ahu Connected With Ac Plant . , ( Iv ) Promptly Attending And Rectification Of Fault/Breakdown Inside And Outside Of Ac Plant As And When Occurs And Same Shall Be Intimate To Je/Age Concern . . , ( V ) Promptly Attending And Rectification Of Fault/Breakdown Inside And Outside Of Ac Plant As And When Occurs And Same Shall Be Intimate To Je/Age Concern . . , ( Vi ) Maintaining Shut Down/Break Down Records Register . , ( Vii ) Security Of Installation Round The Clock . , ( Viii ) Maintaining Records For Temperature , Pressure And Humidity Etc All As Directed . , ( Ix ) Unserviseability Of Any Part/Plant Will Be Reported Immediately To Je E/M Or Engr-In-Charge . , ( X ) Quoted Rates Are Deemed To Include Maintaining Records Of Operation , Providing Stationery Requirements For Maintaining Records Of Plants And Equipments . , ( Xi ) Contractor Should Provide Uniform And Shoes Twice During The Contract To The Employees . , ( Xii ) Contractor Quoted Rates Are Deemed To Incl Torches , Safety Equipments , Measuring Tools , Trademan Tools As Per Site Requirements .

Key Value

Document Fees
INR 500 /-
EMD
INR 58500.0 /-
Tender Value
INR 29.20 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail