| 1 | 1 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . | 32.1 | | |
|---|
| 2 | 1.1 | 70.00 Sq. mm.4 Core armoured U.G. cable | 32.1.4.8 | 60 | Metre |
|---|
| 3 | 1.12 | 120.00 Sq. mm.4 Core armoured U.G. cable | 32.1.4.10 | 160 | Metre |
|---|
| 4 | 2 | Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 2 mm thick conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. | 5.3 | | |
|---|
| 5 | 2.1 | With 3 x 4 sq. mm. + earth continuity with 2x 2.5 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | 5.3.2 | 160 | Metre |
|---|
| 6 | 2.2 | With 3 x 10 sq. mm. + earth continuity with2x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | 5.3.4 | 50 | Metre |
|---|
| 7 | 3 | Supplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised, powder painted single door surface mounting vertical TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar up to 125A and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. | 15.21 | | |
|---|
| 8 | 3.1 | ABB, Schneider MG, legrand, Hager make) | 15.21.1 | | |
|---|
| 9 | 3.12 | 4 way TPN (4+12) double door | 15.21.1.1 | 2 | Each |
|---|
| 10 | 4 | Supplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised, powder painted double door IP-43 surface mounting vertical TPN MCB DB incorporated with bas-bar up to 250A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. | 15.22 | | |
|---|
| 11 | 4.1 | ABB, Schneider MG, legrand, Hager make) | 15.22.1 | | |
|---|
| 12 | 4.12 | 4 way TPN (4+12) double door | 15.22.1.1 | 2 | Each |
|---|
| 13 | 5 | Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. | 16.6 | | |
|---|
| 14 | 5.1 | B Series (Schneider MG, legrand, Hager make) | 16.6.1 | | |
|---|
| 15 | 5.12 | 6 to 32 | 16.6.1.1 | 2 | Each |
|---|
| 16 | 6 | Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. | 16.8 | | |
|---|
| 17 | 6.1 | 100/300mA sensitivity 4P RCCB\n(ABB, Schneider MG, legrand, Hager make) | 16.8.2 | | |
|---|
| 18 | 6.12 | 100A | 16.8.2.5 | 1 | Each |
|---|
| 19 | 7 | Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. | 16.16 | | |
|---|
| 20 | 7.1 | 25 KA 415V 50 Hz 4P MCCB \n(Schneider, legrand, Siemens, Indo Asian make) | 16.16.1 | | |
|---|
| 21 | 7.12 | 100A | 16.16.1.6 | 1 | Each |
|---|
| 22 | 8 | Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. | 16.17 | | |
|---|
| 23 | 8.1 | 35/36 KA 415V 50 Hz 4P MCCB \n(Schneider, legrand, Siemens make) | 16.17.1 | | |
|---|
| 24 | 8.12 | 250A | 16.17.1.2 | 1 | Each |
|---|
| 25 | 9 | Erection of metallic pole of following length in cement concrete\n1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40\nmm nominal size) foundation including excavation and refilling\netc. as required. | DSR 11.3 | | |
|---|
| 26 | 9.1 | Above 6.5 metre and upto 8.0 metre | DSR 11.3.2 | 4 | Each |
|---|
| 27 | 9.2 | Above 8.0 metre and upto 10.0 metre | DSR 11.3.3 | 1 | Each |
|---|
| 28 | 10 | Hot Dip galvanised octagonal pole 8 metre hieght with base plate welded at bottom | M.R | 4 | Each |
|---|
| 29 | 11 | Hot Dip galvanised octagonal pole 10 metre hieght with base plate welded at bottom | M.R. | 1 | Each |
|---|
| 30 | 12 | 150 Watt Flood LED light | MR | 8 | Each |
|---|
| 31 | 13 | Round bracket ( To be mount on pole) Suitable for mounting upto 4 No. of 150 Watt LED light | M.R.. | 1 | Each |
|---|