| 1 | 1 | building maintenance | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.001 | 15.31 : Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. | BI01010001010000000000000515BI0100001114 | 550.48 | sqm |
|---|
| 3 | 1.002 | 10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001115 | 2940.64 | kilogram |
|---|
| 4 | 1.003 | od219735/2019_2020 : Providing and fixing Aluminium sheet roofing accessories 0.45 mm or nearestand polyster top coat 15-18 microns using self drilling /self tapping screws etc complete<br> | BI01010001010000000000000515BI0100001116 | 215 | per metre |
|---|
| 5 | 1.004 | od219736/2019_2020 : Providing and fixing aluminium Trafold sheet pre coated (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.45 mm or nearest available thickness,total coated 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and thickness with zinc coating 120 grams per sqm as per IS: 277, inpolyester top coat 15-18 microns. Sheet should have protective guard film of 25microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge.The sheet shall be fixed using self drilling /self tapping screws of size (5.5x55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curvedsurfaces, excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required. | BI01010001010000000000000515BI0100001117 | 677.257 | sqm |
|---|
| 6 | 1.005 | 14.43 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | BI01010001010000000000000515BI0100001118 | 2269.7 | sqm |
|---|
| 7 | 1.006 | 14.53.1 : Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work | BI01010001010000000000000515BI0100001119 | 2253.5 | sqm |
|---|
| 8 | 1.007 | 11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | BI01010001010000000000000515BI0100001120 | 21.6 | sqm |
|---|
| 9 | 1.008 | 11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. | BI01010001010000000000000515BI0100001121 | 19.5 | sqm |
|---|
| 10 | 1.009 | 14.54.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work | BI01010001010000000000000515BI0100001122 | 134.925 | sqm |
|---|
| 11 | 1.01 | 21.5 : Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ). | BI01010001010000000000000515BI0100001123 | 60 | kg |
|---|
| 12 | 1.011 | 50.12.4.1 : Providing and fixing false ceiling with 7.5 mm thick PVC plain panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete (aluminium frame work shall be paid separately) | BI01010001010000000000000515BI0100001124 | 111.601 | sqm |
|---|
| 13 | 1.012 | od219885/2019_2020 : Providing and fixing PVC door | BI01010001010000000000000515BI0100001125 | 2 | each |
|---|
| 14 | 1.013 | 17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | BI01010001010000000000000515BI0100001126 | 1 | each |
|---|
| 15 | 1.014 | 17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid | BI01010001010000000000000515BI0100001127 | 1 | each |
|---|