Tender For Design Develop Testing Installation And Commissioning Of Scada At Control Room And Signal Data Sharing With Hpcl Plt Terminal As Per Oisd 214 At Pune Bp, Pune BP-Maharashtra

Indian Oil Corporation Limited-IOCL has published Tender For Design Develop Testing Installation And Commissioning Of Scada At Control Room And Signal Data Sharing With Hpcl Plt Terminal As Per Oisd 214 At Pune Bp. Submission Date for this Tender is 25-10-2019. SCADA Tenders in Pune BP Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

22122362
Tender For Design Develop Testing Installation And Commissioning Of Scada At Control Room And Signal Data Sharing With Hpcl Plt Terminal As Per Oisd 214 At Pune Bp
Open Tender
Indian
Maharashtra
Pune BP
25-10-2019

Tender Details

Tender For Design Develop Testing Installation And Commissioning Of Scada At Control Room And Signal Data Sharing With Hpcl Plt Terminal As Per Oisd 214 At Pune Bp

Key Value

Document Fees
Refer document
EMD
INR 36905.0 /-
Tender Value
INR 36.90 Lakhs /-

BOQ Items

Name of Work: Design, Develop, Testing, Installation and commissioning of SCADA at Control Room and Signal/Data Sharing with HPCL PLT Terminal as per OISD-214 at Pune BP
Sl. No. Item Description Item Code / Make Quantity Units
1 2 Supply of Multi Pair Armoured Copper Signal Cables - 1.1 KV - PVC insulated, inner sheathed armoured overall FRLS, HR, PVC Sheathed and shielded signal cables. The cables shall be as per the specifications given elsewhere in the tender document
2 2.1 Two Pair 1.5 Sq MM Copper Signal Cable BI01010001010000000000000515BI0100001113 400 M
3 2.2 Four Pair 1.5 Sq MM Copper Signal Cable BI01010001010000000000000515BI0100001114 600 M
4 2.3 Six Pair 1.5 Sq MM Copper Signal Cable BI01010001010000000000000515BI0100001115 400 M
5 3 Supply of 1.1 KV LT XPLE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as per IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables.
6 3.1 4 core 2.5 sq mm Armoured copper cable BI01010001010000000000000515BI0100001117 600 M
7 4 Supply of Six Core Optical Fibre Cable - Armoured BI01010001010000000000000515BI0100001118 1700 M
8 5 Supply of FLP Pressure Transmitters without local display. Make: Yokogawa / Emerson - Range 0 to 25 Kg / sq cm BI01010001010000000000000515BI0100001119 6 EA
9 6 Supply of FLP Solenoid coils (24 V DC / 230 V AC ) with 3/2 pneumatic valves for opening and closing the air operated ROVs. BI01010001010000000000000515BI0100001120 6 EA
10 7 Supply of Engineering Workstation having 42" HD LED monitor display at control room. • Intel® Core™ i7 Processor or better configuration • 16GB RAM / 2TB HDD or better configuration • 2GB Graphics Card or better configuration The work station shall be compatible and suitable for operation of SCADA - Proficy Ifix 150 Tag. All the software must be licensed of latest version for single user for life time. System should be accessible over existing LAN also. BI01010001010000000000000515BI0100001121 1 EA
11 8 Supply, Installation and commissioing of of 32 inches or above LED screen in CPM's cabin. The screen shall be the duplication of the SCADA screen available at IOCL Control Room. The distance between the control room and the CPM's cabin is about 60 RM. The supply of required cables, connecters shall be in the scope of this item only. BI01010001010000000000000515BI0100001122 1 EA
12 9 Design, procurement, supply, Installation & Commissioning & Testing of PLC along with suitable modules for providing at LPG Pump House inside FLP Enclosure of suitable size so that there is no overheating during the functioning. Supply and providing suitable size FLP enclosure for PLC and AI/ DI converters and any other equipment as required for the purpose of signal transfer from Bullets to PLC at LPG Pump House, shall be in the scope of this item without any extra cost to the Corporation. Pressure, Temp, Levels, Opening closing indication of ROVs, MFM Signal of flow, pressure ETC Shall be transfer in PLC. iNCLUDING lpg Pump operation indication BI01010001010000000000000515BI0100001123 1 EA
13 10 Design, procurement, supply, programming and installation, Commissioning &Testing of LED (HMI) display of size 12" or above in FLP enclosure with glass for display viewing with all the accessories, connectors, double compression FLP glands etc complete. The data being captured by PLC located at LPG Pump House, i.e. PLC No.1 should be displayed in this LED Display. BI01010001010000000000000515BI0100001124 2 LS
14 11 Installation and commissioning of FLP Pressure transmitters including supply of requires size FLP double compression glands. BI01010001010000000000000515BI0100001125 6 EA
15 12 Design, procurement, supply and installation of PLC at IOCL Control Room (PLC No.2 as per schematic drawing and scope of works) along with required modules Ethernet converter, all the accessories / equipment and weather and vermin proof enclosure for the signals being received from LPG PH (PLC No.1) and HPCL Control Room (PLC No.4) and PLC No.-3 already installed in IOCL Control Room for ROVs. The combined signals from PLC No.1 and PLC No.2 to be provided in SCADA IFIX 150 Tag . Installation and commissioning of SCADA shall be in the scope of Contractor. The scope of providing the signal in the required protocol for the SCADA lies with this item The PLC along with the accessories shall be installed in successful bidder supplied weather / vermin proof enclosure BI01010001010000000000000515BI0100001126 1 EA
16 13 Design, procurement, supply, installation, testing and commissioning the ROV open / close operation system with required time delay with respect to open / close time of valve on HPCL main line. The system should operate under the instruction of PLC No.3. The programming shall be as per the instructions of Chief Plant Manager. Item also includes laying of cables on GI cable trays supplied by the contractor and termination of cables with FLP Glands with all required FLP JBs near manifold / apron of bullet area. IOCL shall supply the cables and Limit Switch (Which are mentioned under separate item in this SOR). The other material such as cable trays, FLP Glands, FLP JBS etc, as required shall be supplied by the contractor without any cost to IOCL. BI01010001010000000000000515BI0100001127 1 EA
17 14 Excavation and backfilling of earth for underground cable laying for trench width and depth as mentioned below. Work involves leveling the bed, providing sand cushion, brick protection and back filling after laying the cables, earth strip etc. finishing the top after consolidation and removing the surplus soil from the site of erection as per specification, drawing and directing of the site in-charge. Supply of fine river sand and class-B bricks of approximate size 10"x5"x3" are included the scope of contractor. The item also includes supply and providing cable route markers at every 30 metre interval and bends. BI01010001010000000000000515BI0100001128
18 14.1 300 mm Wide x 750 mm Depth BI01010001010000000000000515BI0100001129 1400 M3
19 15 Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from stores to site, unpacking, erection, dressing including supply and fixing of aluminium tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid vertically on walls / column / structures etc., GI bolts, nuts and washers complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables
20 15.1 4Cx2.5 sqmm (2XWY) BI01010001010000000000000515BI0100001131 600 M
21 15.2 Six Core Optical Fibre Cable - Armoured BI01010001010000000000000515BI0100001132 1700 M
22 15.3 Signal Cables of all sizes BI01010001010000000000000515BI0100001133 1300 M
23 16 Supply and laying of the following sizes of B class GI pipes for cable protection and also for making entry to the cable to the cable duct complete with couplers and bends including sealing of the pipe to make cable entry water proof. Pipe shall be as per IS 1239 Part 1. Item also includes excavation in all types of soils, driveways, roads / clamping the pipes on walls etc., as per the instruction of Engineer In Charge. Supply and laying of PCC for laming good the excavated surface shall be paid extra in separate item. BI01010001010000000000000515BI0100001134
24 16.1 50 mm dia with wall thk- 3.6mm BI01010001010000000000000515BI0100001135 150 M
25 16.2 80 mm dia with wall thk- 4.0mm BI01010001010000000000000515BI0100001136 40 M
26 16.3 100 mm dia with wall thk- 4.5mm BI01010001010000000000000515BI0100001137 40 M
27 17 Plain Cement Concrete in 1(cement) :2 (sand) :4 (coarse aggregate) for making good the broken PCC / Road fro laying cables / pipes / trays etc. BI01010001010000000000000515BI0100001138 4 M3
28 18 Programming and Commissioning the entire system of the signal transfer / sharing and displays as per the scope given in the technical bid. Scope to include installation, programming and commissioning of all the 3 PLCs (2 new 1 existing) as per the requirement of Chief Plant Manager. The system as a whole should work in tandem. The item also includes preparation and submission of circuit drawing of the entire system as per the scope of this tender, including the signal / power cables, internal circuit of the PLC connected terminal boxes, panels, ROV connections etc complete. The successful bidder to hand over all software licenses, keys etc of all the PLCs, Softwares etc. BI01010001010000000000000515BI0100001139 1 EA
29 19 Supply Installation and Commissioing of SCADA - Proficy Ifix 150 Tag Software in Control ROOM BI01010001010000000000000515BI0100001140 1 EA
30 20 supply of Transmitter for Rochesture Gauge (Level Gauge) of 100 MT LPG Bullets .Bullet No. 1,2&3 BI01010001010000000000000515BI0100001141 3 EA
31 21 Installation & commissioning of Transmitters on Rochesture Gauges of Bullet No.-1,2&3 BI01010001010000000000000515BI0100001142 1 JOB
32 22 supply of FLP Temprature Transmitter BI01010001010000000000000515BI0100001143 7 EA
33 23 Installation of Temp Transmitter including FLP cable Gland BI01010001010000000000000515BI0100001144 7 EA
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail