Military Engineer Services-MES has published Repairs To Flooring Rolling Shuttering And Steel Gates Bird Proofing Roofs In Tech Area At Afs Jorhat Under Ge Af Jorhat. Submission Date for this Tender is 31-10-2019. Flooring Work Tenders in GE (AF) JORHAT Assam. Bidders can get complete Tender details and download the document.
Name of Work: REPAIRS TO FLOORING, ROLLING SHUTTERING AND STEEL GATES, BIRD PROOFING, ROOFS IN TECH AREA AT AFS JORHAT UNDER GE (AF) JORHAT | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of cement concrete in ground floor and paving n.exc. 15cm thick below or above ground level complete all as specifed and as directed by Engr-in-Charge. | 102 | Cum | |
2 | 2 | Dismantling of tiles of any description or thickness on wall and floor complete all as specifed and as directed by Engr-in-Charge. | 558 | Sqm | |
3 | 3 | M&L Hardcore or gauge not exceeding 63mm of broken stone deposited spread levelled in layers n.exc 15 cm thick watered and rammed to a true surface complete all as specifed and as directed by Engr-in-Charge. | 11.3 | Cum | |
4 | 4 | M&L for 75 mm thick cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in plinth protcetion and courtyard, laid in slope 1:40, finished cement surfaces even and smooth with out using extra cement complete all as specifed and as directed by Engr-in-Charge. | 150 | Sqm | |
5 | 5 | M&L 100mm thick PCC 1:2:4 type B2 (using 40mm graded aggregate) as in sub base under flooring and hardstanding complete all as specifed and as directed by Engr-in-Charge. | 380 | Sqm | |
6 | 6 | M&L 50 mm thick PCC 1:2:4 type B1 (using 20mm graded aggregate) as in flooring complete all as specifed and as directed by Engr-in-Charge. | 50 | Sqm | |
7 | 7 | M&L for vitrified coloured designer tiles, 10 mm thick square/rectangular) polished, area of each tiles exc .18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed 20 mm thick in cement mortar (1:6) complete all as specifed and as directed by Engr-in-Charge. | 205 | Sqm | |
8 | 8 | M&L for vitrified coloured designer tiles, 10 mm thick square/rectangular) polished, area of each tiles exc .18 sqm but not exceeding 0.38 sqm, as in skirting/dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed 15 mm thick in cement mortar (1:4) complete all as specifed and as directed by Engr-in-Charge. | 23 | Sqm | |
9 | 9 | M&L for non skid ceramic coloured tiles premium quality 300 x 300 x 7mm thick in floors set and jointed in cement slurry and pointed in coloured cement to match over a screed bed of 20mm thick in CM 1:6 complete all as specifed and as directed by Engr-in-Charge. | 20 | Sqm | |
10 | 10 | M&L for glazed ceramic coloured Tiles, 300X200X7/300x350x7/250x250x7mm in size, set on vertical Surfaces such as Skirting, Dado, etc,over and including 15 mm thick screed bed in cement mortar 1:6 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specifed and as directed by Engr-in-Charge. | 75 | Sqm | |
11 | 11 | M&L Glazed coloured Chequered Cement Concrete Tiles 300X300X25mm/200x200x25mm thick, Set and Jointed in Neat Cement Slurry with Grey Cement and Pigment over and including Screed Bed 20 mm thick in Cement Mortar (1:6) as in Path, complete all as specifed and as Directed by Engr-in-Charge. | 115 | Sqm | |
12 | 12 | M&L coloured machine pressed precast concrete intelocking paver block 60mm thickness any shape and size confirming to IS 15658-2006 of M-35 grade with grey cement and no pigment, including 100mm thick sand cushioning under the paver, complete all as specifed and as Directed by Engr-in-Charge. | 70 | Sqm | |
13 | 13 | Taking down Cement Plaster, any description on Brick Walls or on Concrete Surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specifed and as Directed by Engr-in-Charge. | 330 | Sqm | |
14 | 14 | Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, keep Serviceable Bricks in Safe Custody for re-use, complete all as specifed and as Directed by Engr-in-Charge | 5 | Cum | |
15 | 15 | M&L for Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 metre mean Radius, built in Cement Mortar 1:6, complete all as specifed and as Directed by Engr-in-Charge. | 5 | Cum | |
16 | 16 | M&L for rendering 15mm thick in Cement Mortar 1:6 on fair faces of brick work or concrete surfaces, plastered surfaces finishing even and smooth without using extra cement, complete all as specifed and as directed by Engr-in-Charge. | 180 | Sqm | |
17 | 17 | M&L for rendering 15mm thick in Cement Mortar 1:4, finishing Plastered Surfaces even and smooth without using extra cement, complete all as specifed and as directed by Engr-in-Charge. | 150 | Sqm | |
18 | 18 | M & L for preparing newly plastered surface of wall and applying tow coats of oil emulsion distempering over a coat of premer complete all as specifed and as Directed by Engr-in-Charge. | 100 | Sqm | |
19 | 19 | M & L for preparing newly plastered surface of wall and applying two coats of cement base paint over a coat of premer complete all as specifed and as Directed by Engr-in-Charge. | 150 | Sqm | |
20 | 20 | Demolition of Cement Concrete (reinforced) of any description, not exc. 150mm thickness (above or below Ground Level) and removing the same from Site(s), complete all as specifed and as directed by Engr-in-Charge. | 5 | Cum | |
21 | 21 | M&L for Reinforced Cement Concrete type B-1, 1:2:4 (using 20 mm Graded Stone Aggregate) in Lintels, Cills, Seismic and other Similar Bands, Copings, Bed Plates, etc.complete all as specifed and as directed by Engr-in-Charge. | 5 | Cum | |
22 | 22 | M&L for mild steel TMT bar 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends binding with and including mild steel wire not less then 0.9 mm dia or securing with clips quality conforming etc.complete all as specifed and as Directed by Engr-in-Charge. | 45 | Kg | |
23 | 23 | M&L for formwork to sides and soffits of floor or floor or roof beams, beam haunchings, girders, bresummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc also splays between floors and beams etc.complete all as specifed and as Directed by Engr-in-Charge. | 20 | Sqm | |
24 | 24 | Dismantling structural steel work including doors, gates but excluding framed fruss etc. complete all as specifed and as Directed by Engr-in-Charge. | 14 | Qtl | |
25 | 25 | M&L for joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specifed and as Directed by Engr-in-Charge. | 700 | Kg | |
26 | 26 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging\ndoor fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete confirming to FE-410W(Grade E-250) quality A complete all as specifed and as Directed by Engr-in-Charge. | 600 | Kg | |
27 | 27 | S & F Mild steel, plain, black sheet 1.60mm thick in hearths;covering to door shut ters; covering to door chowkats (frames);chullah hoods; water tanks; water troughs; ducts; urinal troughs and unnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required and complete all as specifed and as Directed by Engr-in-Charge. | 12 | Sqm | |
28 | 28 | S&Fmild steel articles such as bands, straps, supports or stays for rain water,holdfasts etc conforming to Fe 290 Gde- E-165 complete all as specifed and as Directed by Engr-in-Charge. | 10 | Kg | |
29 | 29 | M & L PCC(1:2:4) type B 1 using 20mm graded stone aggregate as in holdfast including formwork complete all as specifed and as Directed by Engr-in-Charge. | 0.3 | Cum | |
30 | 30 | M&L for preparing new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint(first quality) over a coat of primer complete all as specifed and as Directed by Engr-in-Charge. | 70 | Sqm | |
31 | 31 | M&L for preparing old steel surfaces of any description , over 10 cm width or girth and applying one coat of synthetic enamel paint(first quality) complete all as specifed and as Directed by Engr-in-Charge. | 150 | Sqm | |
32 | 32 | S/F of sheet glass 3 mm thick ordinary glass with oil putty in square n.exc 0.5 sq.m in each pane including hacking out old glass complete all as specifed and as directed by Engr-in-Charge. | 5 | Sqm | |
33 | 33 | S&F stainless Steel Wire Cloth, 0.36mm nominal dia of Wire and average width of aperture 1.4 mm and fixed with Tinned Tacks of Mild Steel Wire Stapes, fixing and repair etc, complete all as specifed and as Directed by Engr-in-Charge. | 10 | Sqm | |
34 | 34 | S&F in repairs Steel Water Tubing 15mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation including Taking up or down unserviceable Steel Water Tubing with Fittings and Connections, etc, complete all as specifed and as Directed by Engr-in-Charge. | 30 | RM | |
35 | 35 | S/F in repair 15 mm bib taps CP fancy type with crutch with butter fly handle, screwed for iron pipe or brass ferrule, complete all as specifed and as Directed by Engr-in-Charge. | 5 | Each | |
36 | 36 | S&F in repairs Pillar Taps 15mm Bore, Cast Copper Alloy with Capstan Heads, Chromium Plated, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ with long screwed Shanks and Fly-Nuts, screwed for Iron Pipe and fixed-in-repairs, complete all as specifed and as Directed by Engr-in-Charge | 2 | EACH | |
37 | 37 | S/F in repair 10 litres cap PVC low level valve less symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and flushing pipe, complete all as specifed and as Directed by Engr-in-Charge | 4 | Each | |
38 | 38 | S/F in repair Vitreous China wash basin, white, flat back size 580x450 mm including brackets, waste pipe etc complete all as specifed and as Directed by Engr-in-Charge | 2 | Each | |
39 | 39 | S & Fixed in repair Vitreous China Squatting Pan ‘ORISSA’ Pattern, size 580X440 mm White, with ‘P’ or ‘S’ Trap, Integral Foot Rest, providing Joints between Flush Pipe and Socket of WC Pan (excluding Flushing Cistern and Flush Pipe), fixing with and including provision of 150mm thick Lime Concrete Bedding including Taking out unservice able WC Pan and connected Items, complete all as specifed and as Directed by Engr-in-Charge | 2 | Each Job | |
40 | 40 | S&F in repair Towel rail 450 mm long of PTMT fixed with and including chromium plated brass screw and wooden/plastic cleats complete all as specifed and as Directed by Engr-in-Charge | 6 | Each | |
41 | 41 | Supply and fix in repairs 600x450 mm level edge mirror selected quality glass, mounted on 6mm thick AC building boards or commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers, complete all as specifed and as Directed by Engr-in-Charge | 3 | Each | |
42 | 42 | M&L 150 mm thick PCC 1:2:4 type B2 (using 40mm graded aggregate) as in sub base under flooring and hardstanding all as specified and directed. | 50 | Sqm | |
43 | 43 | M&L 40 mm thick PCC 1:2:4 type B1 (using 20mm graded aggregate) as in flooring finishing cement mortar even and smooth complete all as specifed and as Directed by Engr-in-Charge | 50 | Sqm | |
44 | 44 | M& L for hardcore of brick bats of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specifed and directed | 12 | Cum | |
45 | 45 | M&L for cement concrete 150mm thick in foundations, filling and mass-concrete type D2, 1:4:8 (using 40mm graded aggregate) including emolition of cement concrete in ground floor and paving n.exc. 15cm thick below or above ground level complete all as specifed and as Directed by Engr-in-Charge | 7.5 | cum | |
46 | 46 | Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade of glazed of choice colour over 25mm thick sand filling complete all as specifed and as Directed by Engr-in-Charge | 50 | Sqm | |
47 | 47 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including nainital or similar pattern roof complete all as specifed and as Directed by Engr-in-Charge | 395 | Sqm | |
48 | 48 | S &F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specifed and as Directed by Engr-in-Charge | 300 | Sqm | |
49 | 49 | S &F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specifed and as Directed by Engr-in-Charge | 15 | Sqm | |
50 | 50 | S/F Galvanised corrugated mild steel sheeting with rectangular corrugation having grade of zinc coating 275, side lap, fixed with L-type or J type or cranked hook bolts and washers in roofs, walls etc class 8 type 0.80 mm thick complete all as specifed and as Directed by Engr-in-Charge | 60 | Sqm | |
51 | 51 | S/F 0.80 mm thick plain galvanized PGI sheets having grade of zinc coating 275, in ridges, hips ,vally gutters, etc class 8 complete all as specifed and as Directed by Engr-in-Charge | 20 | Sqm | |
52 | 52 | M & L for preparation of new plastered decorated concrete surfaces on walls over 10cm width or girth and applying two coats of acrylic base exterior paint over a coat of primer as per manufacture instructions ( camaflouge type) of each irregular shaped area painting with difference tint( as approved by GE) complete all as specifed and as Directed by Engr-in-Charge | 80 | Sqm | |
53 | 53 | M & L for preparation of old plastered decorated concrete surfaces on walls over 10cm width or girth and applying one coats of acrylic base exterior paint over a coat of primer as per manufacture instructions ( camaflouge type) of each irregular shaped area painting with difference tint (as approved by GE)\nNote:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ. | 870 | Sqm |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy