| 1 | 1 | M & L for checking & repairing Street lights/flood lights/tower lights/highmast lights & other connected work as directed in tech area daily and repairing of lights found unserviceable during checking or as per directed by JE/Engr-in-Charge/men on complaint cell including rectification of fault of cable/lights etc by deploying skilled Electrician, helper with all tools & plants, ladder, gaskets safety arrangements and including providing minor materials like insulation tap and connected material by contractor to make light almost 100% serviceable complete all as specified and directed.\nNOTES :-\n(i) Rate quoted shall deemed to be included for required minor material like insulation tap/repairing of junction box with lugs etc.\n(ii) Items like Driver for LED and other items other than mentioned above paid separately.\n(iii) Contractor shall provide labour everyday at site and as per direction of Engr-in-Charge. | | 800 | Each Job |
|---|
| 2 | 2 | Supply only Driver for LED lights of make Havells/Bajaj/Philips/CG/Wipro/C&S or as per existing make for the following capacity :- | | | |
|---|
| 3 | 2.01 | Driver for 30 to 60 watts LED | | 30 | Each |
|---|
| 4 | 2.02 | Driver for 70 to 80 watts LED | | 50 | Each |
|---|
| 5 | 2.03 | Driver for 90 to 120 Watts LED | | 50 | Each |
|---|
| 6 | 2.04 | Driver for 120 to 200 Watts LED Flood light | | 15 | Each |
|---|
| 7 | 3 | Taking down old unserviceable light fitting any type, description and capacity at any height complete all as specified and directed | | 110 | Each |
|---|
| 8 | 4 | Supply and fixing connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium housing LED Street light luminaires with IP-66 70/72 Watt LED as light source suitable for pole dia 54 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed | | 20 | Each |
|---|
| 9 | 5 | Supply and fixing connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 90 Watt LED with high power LED as light source suitable for pole dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed | | 25 | Each |
|---|
| 10 | 6 | Supply and fixing, connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 120 Watt LED with high power LED as light source suitable for pole dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed | | 15 | Each |
|---|
| 11 | 7 | Supply and fixing energy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP-66 flood light 120 watt capacity with high power LEDs as light source including making connection with three core PVC insulated and PVC sheathed copper conductor cable complete all as specified and directed. | | 20 | Each |
|---|
| 12 | 8 | Supply and fixing energy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP-66 flood light 150 watt capacity with high power LEDs as light source including making connection with three core PVC insulated and PVC sheathed copper conductor cable complete all as specified and directed. | | 20 | Each |
|---|
| 13 | 9 | Supply and fixing energy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP-66 flood light 200 watt capacity with high power LEDs as light source including making connection with three core PVC insulated and PVC sheathed copper conductor cable complete all as specified and directed. \nMake:- Bajaj/Havells or equivalent in Philips/Wipro | | 15 | Each |
|---|
| 14 | 10 | Supply and fixing in repair PVC insulated and PVC sheathed twin core Copper conductor of size 1.5 Sqmm for connecting from bus bar box to street light fittings/ OH line to street light fitting complete all as specified and directed. | | 400 | RM |
|---|
| 15 | 11 | Taking down old unserviceable power contactor/timer/MCCB of any type , any description and capacity complete all as specified and directed | | 5 | Each |
|---|
| 16 | 12 | Supply & fixing of Automatic Street Light Switch for 3-phase Load of 12 KW using Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS) for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux* level. Required Illuminance Level for Switching ON is = 30 Lux and for Switching OFF = 10 Lux. The Sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. The Sensor along with suitable Power Contactors with 3 nos. Contactors, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 32-40 Amps each. Circuit wiring (Copper) of min.10 sq.mm and Auto-Manual selection option (Sensor By-Pass) should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP-66. \nMake & Model No. SWADEEP-VMS-12KW3P/Havells or equivalent as approved by GE. | | 3 | Each |
|---|
| 17 | 13 | Supply & fixing of Automatic Street Light Switch for 3-phase Load of 08 KW using Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS) for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux* level. Required Illuminance Level for Switching ON is = 30 Lux and for Switching OFF = 10 Lux. The Sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. The Sensor along with suitable Power Contactors with 3 nos. Contactors, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 20-32 Amps each. Circuit wiring (Copper) of min.10 sq.mm and Auto-Manual selection option (Sensor By-Pass) should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP-66. \nMake & Model No. SWADEEP-VMS-8KW3P/Havells or equivalent as approved by GE. | | 2 | Each |
|---|
| 18 | 14 | Supply and fixing in replacement MS Junction boxes of size 300mm X 300mm X 150mm depth, fabricated with 2.00mm thick MS sheets duly painted with two coats of synethic enamelled paint over a coat of red oxide primer fixed on Lt Pole with 2 Nos MS Clamps of 25 x 5mm FI and nut, bolt, washers including 4 Nos Aluminium bus bars 100Amps on insulators and 1 No of MCB 10 Amp and locking arrangement with steel sliding bolts including disconnecting and reconnecting cables with suitable lugs complete. | | 90 | Each job |
|---|
| 19 | 15 | Supplying, fabricating, fixing in position cross arms, bracings, supports, clamps and back plates, fabricated from structural steel section any type /size /shape incl nuts, bolts, washers, welding, bending hot or cold, drilling holes for bolts, in any shape or size as required at site, including painting with two coats of aluminium paint over a coat of red oxide primer including taking down complete all as specified and directed. | | 1 | Qtl |
|---|
| 20 | 16 | Dismantling of GI light bracket 40mm dia of any description complete all as specified and directed. | | 50 | Each |
|---|
| 21 | 17 | S&F GI pipe light grade bracket 40mm dia, 1.5m long bent to shape as required for fixing of street lights on poles/walls including nuts, bolts, washers , Clamps (02 sets) of suitable size complete all as specified and directed. | | 50 | Each |
|---|
| 22 | 18 | Design, fabricate, supply, install, test and commissioning of factory made floor mounted LT cubical panel board Out door type (double door) made out of 3.15mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opening and locking arrangement 415Volts, 3 phase, 50 Hz having aluminium bus bar of capacity 500 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit current with stand minimum 85 KA for one second complete connection from bus bar to breakers with suitable copper cable , panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc. The panel board shall be powder coated and red oxided primed. \nThe panel board shall be fabricated from the reputed CPRI approved firm and shall be suitable to accommodate and supply and fixing of the following complete all as specified and directed :-\n(A) Incoming :-\n(a) MCCB 4P, 250, 36KA Adjustable type - 01 No \n(b) Digital type Ammeter Flush mounted of size 96 mmx96 mm 3 phase 0-500 Amps with Suitable ratio CT's and selector switch, aux supply 230 volt AC - (01) no, \n(c) Digital type Voltmeter Flush mounted of size 96 mmx96 mm 3 phase 0-500 volts with selector switch, aux supply 230 volt AC - (01) no, \n(d) Indicating lamps for three phases - Qty 1 set of 3 Nos \n(B) Out going :- \n(a) MCCB 4P, 160A, 25KA Adjustable type -01 Nos\n(b) MCCB 4P, 100A, 25KA Adjustable type -02 Nos\n(c) MCCB 4P, 63A, 16KA Adjustable type -02 Nos | | 1 | Each Job |
|---|