| 1 | 1 | Excavation in trenches in soft loose soil not exceeding 1.5 m deep and not exceeding 1.5 m width and getting out including forming bottom surface for laying cables/pipes all as specified and directed. | | 700 | Cum |
|---|
| 2 | 2 | Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm thick after the cables are laid, jointed & tested complete all as specified and directed | | 420 | Cum |
|---|
| 3 | 3 | Removing of surplus excavated soil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified. | | 280 | Cum |
|---|
| 4 | 4 | Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. | | 220 | Cum |
|---|
| 5 | 5 | Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed. | | 17 | Per 1000 Nos |
|---|
| 6 | 6 | Laying only old retrieved serviceable bricks for cable protection with axis of the bricks perpendicular to the axis of the cable of any description as obtained from dismantling of the cable complete all as specified and directed. | | 5 | Per 1000 Nos |
|---|
| 7 | 7 | M&L boring of holes under road, pavement, hard standing by manually depth not less than 75 cm for insertion of GI Pipe of size 80 mm bore light grade for short length complete all as specified and directed. \nNote :- GI pipe 80 mm dia light grade shall be measured and paid separately under relevant item of Schedule 'A'. | | 50 | RM |
|---|
| 8 | 8 | Supply and fixing of GI Pipe 80 mm dia light grade for cable protection complete all as specified and directed. Make:- Jindal/Tata | | 50 | RM |
|---|
| 9 | 9 | Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any description, any size and in any position complete including taking down protection pipe etc all as specified and directed for the following size of cables :-\n | | | |
|---|
| 10 | 9.01 | 10 Sqmm to 35 Sqmm of any core | | 600 | RM |
|---|
| 11 | 9.02 | 50 Sqmm to 95 Sqmm 3.5 Core | | 850 | RM |
|---|
| 12 | 9.03 | 120 Sqmm to 185 Sqmm 3.5 Core | | 600 | RM |
|---|
| 13 | 9.04 | 240 Sqmm to 400 Sqmm 3.5 Core\nNote for item No 9.01 to 9.04:1.Excavation and earth work will be measured and paid separately under relevant item of Sch 'A'.\n2. Contractor shall attend the complaint within 12 hours and rectify the same in maximum 24 hours only. | | 600 | RM |
|---|
| 14 | 10 | Re-laying, jointing and testing of serviceable retrieved LT cable from item No. 1 above (after thorough inspection of cable) XLPE / PVC insulated, armoured, heavy duty, aluminum conductor cable 1100 Volts grade of any description, laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :- \n | | | |
|---|
| 15 | 10.01 | 10 Sqmm to 35 Sqmm any core | | 300 | Per RM |
|---|
| 16 | 10.02 | 50 Sqmm to 95 Sqmm 3½ core | | 350 | Per RM |
|---|
| 17 | 10.03 | 120 Sqmm to 185 Sqmm 3½ core | | 300 | Per RM |
|---|
| 18 | 10.04 | 240 Sqmm to 400 sqmm 3½ core\n | | 200 | Per RM |
|---|
| 19 | 11 | Supply, Laying & connecting cable 1100 Volts grade, stranded aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cable of following sizes conforming to IS 7098 (Part-I) amended upto date complete all as specified and directed.\n | | | |
|---|
| 20 | 11.01 | 16 Sqmm x 4 core | | 300 | Per RM |
|---|
| 21 | 11.02 | 50 Sqmm x 3.5 core | | 250 | Per RM |
|---|
| 22 | 11.03 | 95 Sqmm x 3.5 core | | 250 | Per RM |
|---|
| 23 | 11.04 | 150 Sqmm x 3.5 core | | 300 | Per RM |
|---|
| 24 | 11.05 | 240 Sqmm x 3.5 core | | 200 | Per RM |
|---|
| 25 | 11.06 | 400 Sqmm x 3.5 core\nNote for Item No 11.01 to 11.06 :- (i). Lugs/Glands/saddles of suitable size required for fixing of cables in panels/junction boxes /on walls shall be included in the item rate.\n(ii) Cable path indicators shall be provided at every 50 mtr intervals of the cable is deemed to included in the item rate. | | 200 | Per RM |
|---|
| 26 | 12 | Supplying, fixing, jointing and testing for provision of straight through joints Heat shrinkable type, suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cables all as specified and directed. \n | | | |
|---|
| 27 | 12.01 | 10 Sqmm to 16 Sqmm any core | | 5 | Each |
|---|
| 28 | 12.02 | 25 Sqmm to 50 Sqmm 3½ core | | 8 | Each |
|---|
| 29 | 12.03 | 70 - 150Sqmm 3½ core | | 8 | Each |
|---|
| 30 | 12.04 | 185 -240 Sqmm 3½ core | | 8 | Each |
|---|
| 31 | 12.05 | 300-400 Sqmm 3½ core | | 8 | Each |
|---|
| 32 | 13 | Labour only for checking and disconnecting the cable from both ends, testing the serviceability of cable and reconnecting the same complete all as specified and directed of following sizes:- | | | |
|---|
| 33 | 13.01 | 10 Sqmm to 25 Sqmm any core | | 15 | Each Job |
|---|
| 34 | 13.02 | 35 Sqmm to 70 Sqmm 3½ core | | 15 | Each Job |
|---|
| 35 | 13.03 | 95 Sqmm to 150 Sqmm 3½ core | | 15 | Each Job |
|---|
| 36 | 13.04 | 185 Sqmm to 240 sqmm 3½ core | | 10 | Each Job |
|---|
| 37 | 13.05 | 300 Sqmm to 400 sqmm 3½ core | | 10 | Each Job |
|---|
| 38 | 14 | Disconnecting the electric connections, removing the old unserviceable bus bar box of any description and in any position complete all as specified and directed. | | 5 | Each |
|---|
| 39 | 15 | M&L bus bar box outdoor type made out of 3.15 mm thick MS sheet, 3 phase, 4 wire, 415 Volts AC supply, outdoor cubical type, dust and vermin proof, floor block mounting type suitable for outdoor applications of size 600mmx600mmx450mm, using 40mm x 40mm x 5 mm angle iron frame with shutter and locking arrangement painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer(internally and externally)for box, height above ground 600mm and grouted 300 mm below ground, legs of frame shall be grouted in PCC 1:2:4 (size 300x300x300mm block) and complete including 40mmx10mm-04 nos 500mm long aluminium busbar fixed on insulators with proper colour coding, all as specified and directed. | | 5 | Each Job |
|---|