Dairy Statutory Bodies & Commissions/Committees Closing in 0 days TDR #22103281

Tender For Cable Tray & Accessories Including Cable Trays, Clamps, Cable Glands, Lugs, Cable Route Markers, Identification Tags, Gi Conduits, Etc. , Earthing System Consisting Of Earthing Pit, Earthing Conductors, And All Earthin

Issued by Statutory Bodies & Commissions/Committees · , Multi State
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Oct 2019
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Multi State
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Cable Tray & Accessories Including Cable Trays, Clamps, Cable Glands, Lugs, Cable Route Markers, Identification Tags, Gi Conduits, Etc. , Earthing System Consisting Of Earthing Pit, Earthing Conductors, And All Earthing Accessories. As Per Requirement , Refrigeration Plant Instruments & Controls As Per Requirement Ammonia Leak Detection System As Per Requirement Safety Accessories As Per Requirement Ammonia As Per Requirement Refrigerent, Oil And Other Consumables With Freon & Charging Hose. As Per Requirement Dismantling Of Existing Compressors ( Kc402 Nos. & Kc202 Nos. ) As Per Requirement Service Cover For One Year As Per Requirement Amm. Reciprocating Compressor ( 5Sst / + 40Sdt ) High Stagewith Motor, Oil Separator, Oil Filters, Drive Motor And Softstarter, Complete With All Associated Accessories Minimum 2, 34, 000 Kcals / Hr For Each Compressor, Operating At 5° 40°C Sdt Amm. Reciprocating Compressor ( 5Sst / + 40Sdt ) High Stagewith Motor, Oil Separator, Oil Filters, Drive Motor And Softstarter, Complete With All Associated Accessories Minimum 1, 17, 000 Kcals / Hr For Each Compressor, Operating At 5° 40°C Sdt Chilled Water Pump Vertical Inline Pumps Of Ss Parts Capacity 70 M3 / Hr At 35 Mwc Pipes, Valves & Fittings For Refrigerant, Oil & Safety Etc. Including Copper Tubing For Package Type Units. Suitable The System Pipes, Valves & Fittings For Water, Drain Etc. Including Accessories For Cooling Water Suitable For The System Insulation Of Floor For Cold Store ? Curd Cold Store1 Curd Precooling Room, Incubation Room And Airlock. Conventional Insulation For Puf Slabs In Two Layers Layer Having 40 Mm Thick ) Of 80Mm Thickness Insulation Of Ceiling / Walls With Prefab Panels For Cold Store Curd Cold Store1 & 2, Curd Precooling Room, Incubation Room And Airlock. Preengineered Prefabricated Sandwiched Rigid Poly Urethane Panel ( Both Side Pcgi ) Thickness Insulation Of Ceiling / Walls With Prefab Panels For Cold

AI Tender Summary

OUR REF NO 22103281
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 31-10-2019
Authority
Authority Name National Dairy Development Board
Work Description Tender For Cable Tray & Accessories Including Cable Trays, Clamps, Cable Glands, Lugs, Cable Route Markers, Identification Tags, Gi Conduits, Etc. , Earthing System Consisting Of Earthing Pit, Earthing Conductors, And All Earthing Accessories. As Per Requirement , Refrigeration Plant Instruments & Controls As Per Requirement Ammonia Leak Detection System As Per Requirement Safety Accessories As Per Requirement Ammonia As Per Requirement Refrigerent, Oil And Other Consumables With Freon & Charging Hose. As Per Requirement Dismantling Of Existing Compressors ( Kc402 Nos. & Kc202 Nos. ) As Per Requirement Service Cover For One Year As Per Requirement Amm. Reciprocating Compressor ( 5Sst / + 40Sdt ) High Stagewith Motor, Oil Separator, Oil Filters, Drive Motor And Softstarter, Complete With All Associated Accessories Minimum 2, 34, 000 Kcals / Hr For Each Compressor, Operating At 5° 40°C Sdt Amm. Reciprocating Compressor ( 5Sst / + 40Sdt ) High Stagewith Motor, Oil Separator, Oil Filters, Drive Motor And Softstarter, Complete With All Associated Accessories Minimum 1, 17, 000 Kcals / Hr For Each Compressor, Operating At 5° 40°C Sdt Chilled Water Pump Vertical Inline Pumps Of Ss Parts Capacity 70 M3 / Hr At 35 Mwc Pipes, Valves & Fittings For Refrigerant, Oil & Safety Etc. Including Copper Tubing For Package Type Units. Suitable The System Pipes, Valves & Fittings For Water, Drain Etc. Including Accessories For Cooling Water Suitable For The System Insulation Of Floor For Cold Store ? Curd Cold Store1 Curd Precooling Room, Incubation Room And Airlock. Conventional Insulation For Puf Slabs In Two Layers Layer Having 40 Mm Thick ) Of 80Mm Thickness Insulation Of Ceiling / Walls With Prefab Panels For Cold Store Curd Cold Store1 & 2, Curd Precooling Room, Incubation Room And Airlock. Preengineered Prefabricated Sandwiched Rigid Poly Urethane Panel ( Both Side Pcgi ) Thickness Insulation Of Ceiling / Walls With Prefab Panels For Cold
Basic Detail
Tender No NDDB//19-20/ET/67
Bidding Type Tender
Location
City
State Multi State
Key Dates
Publish Date 11 Oct 2019
Submission Date 31 Oct 2019
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
e3e06e73-2598-4bdd-bf21-2aa633d62487.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 01, 1900
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 31, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

e3e06e73-2598-4bdd-bf21-2aa633d62487.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender