Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #22050269

Repairs/Replacement To Roof Treatment And Cleaning Of Oh Tanks Of Certain Bldgs In South Area At Nasirabad Repairs/Replacement To Roof Treatment And Cleaning Of Oh Tanks Of Certain Bldgs In South Area

Issued by Statutory Bodies & Commissions/Committees · Nasirabad, Rajasthan
Tender Value
13.50 Lakhs
Estimated cost
Bid Submission
01 Nov 2019
0 days left
EMD
27000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nasirabad → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repairs/Replacement To Roof Treatment And Cleaning Of Oh Tanks Of Certain Bldgs In South Area At Nasirabad Repairs/Replacement To Roof Treatment And Cleaning Of Oh Tanks Of Certain Bldgs In South Area

BOQ

Name of Work: REPAIRS/REPLACEMENT TO ROOF TREATMENT & CLEANING OF OH TANKS OF CERTAIN BLDGS IN SOUTH AREA AT NASIRABAD
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Taking down existing unserviceable treatment of any description including cement plaster/cement concrete of any thickness from roof surface cleaning of roof surfaces and preparing it for further treatment and removing rubbish from the site up to 50mtrs complete all as specified and directed.BI01010001010000000000000515BI01000011191300SQM
22Demolition of cement concrete (unreinforeced) of any description & in any position not otherwise specifically provided for complete all as specified and directed.BI01010001010000000000000515BI01000011201.5CUM
33M & L for cutting out cracks to 'V' section in existing roofs or terracing, cleaning out and filling solidly with hot mixture of bitumen and clean dry sand (1:1) by weight complete all as specified and directed.BI01010001010000000000000515BI0100001121150RM
44M&L for screeding 10mm thick in CM 1:4 mixed with water proofing compound @ 3% by weight of cement on fair faces of RCC /stone patti roof surface finished fair & even without using extra cement even complete all as spescified and directed.BI01010001010000000000000515BI01000011221300SQM
55Supply only liquid water proofing compound complete all as spescified and directed.BI01010001010000000000000515BI010000112310litre
66M & L for five layered roof treatment with APP modified polymeric water proofing membrane, 2mm thick having centre core not less than 100 micron high molecular high density polythylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 micron HMHDPE film weight not less than 3 Kg/ Sqm applied with bonding material using blown type bitumen Grade 85/25 @ 1.20 Kg/ Sqm over bitumen primer conforming to IS- 3384 @ 0.40 Kg/ Sqm with final coat of bonding bitumen grade 85/25 @ 1.20 Kg/ Sqm over APP membrane with all overlaps complete all as specified and directed.BI01010001010000000000000515BI01000011241300SQM
77Material and labour for 40mm thick (average consolidated thickness) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate laid in slope as in padding, finished even and smooth on existing slope including provision of 'V' shaped groove 6mm wide and 10mm deep at 0.6metre interval or parts thereof, both ways on top of PCC padding and filled with mastic bitumen of (1:1) proportion complete all as specified and directed.BI01010001010000000000000515BI01000011251300SQM
88M & L for coved filled in PCC (1:3:6) type C-1 using 20 mm graded stone aggregate at junction of roof and parapet wall / mumty / other vertical space and applying a coat of bituminous primer conforming to IS-3384 @0.30 litre/Sqm complete all as specified and directed.BI01010001010000000000000515BI01000011261.5CUM
99Disconnecting existing tank of capacity 500 litre, keeping aside (or lowering if required) for repairs, cleaning etc and hoisting it required, reconnecting and refixing in position complete all as specified and directed.BI01010001010000000000000515BI010000112760EACH
1010All as per item No 9.00 here-in-before but 1000 litre capacityBI01010001010000000000000515BI010000112825EACH
1111Dismantling stone slabs in roofs, suspended floors, chajjas, landing etc of any thickness, jointed in any mortar complete all as specified and directedBI01010001010000000000000515BI01000011294X SQM
1212M & L 40mm thick sand stone slab, set & jointed on joints in CM 1:4 including 25mm thick PCC 1:2:4 type, B-0, using 12.5mm graded crushed stone aggregate (for providing bottom cover to PVC tank) complete all as specified and directed.BI01010001010000000000000515BI010000113030SQM
1313All as per Sl Item No 12.00 here in before but except stone slab.\nNOTE: Serviceable stone slab retrieved vide Sl Item No 11.00 shall be reused.BI01010001010000000000000515BI010000113110SQM
1414Taking up or down steel tubing and connection 15mm bore keeping aside for reuse or removing to store complete all as specified and directed.BI01010001010000000000000515BI0100001132130RM
1515All as per item No. 14.00 here-in-before but 20mm boreBI01010001010000000000000515BI0100001133110RM
1616All as per item No. 14.00 here-in-before but 25mm diaBI01010001010000000000000515BI010000113480EACH
1717Supply and fix mild steel water tubing 15 mm dia galvanised medium grade including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid on floors including testing complete all as specified and as directed.BI01010001010000000000000515BI010000113590RM
1818All as per item No. 17.00 here-in-before but 20mm diaBI01010001010000000000000515BI010000113680RM
1919All as per item No. 17.00 here-in-before but 25mm boreBI01010001010000000000000515BI010000113770RM
2020Fixing only old GI tubing 15mm bore to walls, ceiling or laid in floor including necessary cleaning, cutting, screwing and new fittings such as elbow, Tee, union, socket, reducer etc of following sizes complete all as specified and directed.\nNote: Serviceable GI tubing retrieved vide Sl Item No.14.00 shall be reusedBI01010001010000000000000515BI010000113840RM
2121All as per item No. 20.00 here-in-before but 20mm bore.\nNote: Serviceable GI tubing retrieved vide Sl Item No.15.00 shall be reusedBI01010001010000000000000515BI010000113930RM
2222All as per item No.20.00 here-in-before but 25mm bore.\nNote: Serviceable GI tubing retrieved vide Sl Item No.16.00 shall be reusedBI01010001010000000000000515BI010000114010RM
2323Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.BI01010001010000000000000515BI01000011412.5CUM
2424M & L for brick work of flyash bricks of old size built in CM (1:6) straight or curred on plan exc 6 m mean radius complete all as specified and directed.BI01010001010000000000000515BI01000011422.5CUM
2525Taking down cement or cement lime plaster on stone/brick wall, ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.BI01010001010000000000000515BI010000114360SQM
2626M & L for rendering in cement mortar (1:4), 10mm thick on Conc/ brick masonry surfaces finished fair and even complete all as specified and directed.BI01010001010000000000000515BI010000114480SQM
2727M & L for 15mm thick rendering in CM (1:4) on stone masonry external surfaces of wall finished even and smooth complete all as specified and directed.BI01010001010000000000000515BI010000114560SQM
2828Dismantling of rain water pipes of bore 100mm, AC/PVC, set in cement mortar complete all as specified and directed.BI01010001010000000000000515BI010000114650RM
2929S & F 110mm bore PVC (SWR) rain water pipe, single socket in any length with rubber ring joints fixed to walls or laid in floors / trenches complete all as specified and directed.BI01010001010000000000000515BI010000114740RM
3030All as per Sl Item No 29.00 here in before but except pipe.\nNOTE: Serviceable pipe retrieved vide Sl Item No 28.00 shall be reused.BI01010001010000000000000515BI010000114810RM
3131S & F stack clamp out of 50 x 3mm flat iron and 16mm dia round iron stays fixed to pipe of bore 110mm complete all as specified and directed.BI01010001010000000000000515BI010000114910EACH
3232S & F PVC (SWR) bends any radius of 110mm bore complete all as specified and directed.BI01010001010000000000000515BI01000011506EACH

AI Tender Summary

OUR REF NO 22050269
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 13.50 Lakhs
LAST DATE 01-11-2019
Authority
Authority Name Military Engineer Services
Work Description Repairs/Replacement To Roof Treatment And Cleaning Of Oh Tanks Of Certain Bldgs In South Area At Nasirabad Repairs/Replacement To Roof Treatment And Cleaning Of Oh Tanks Of Certain Bldgs In South Area
Basic Detail
Tender No 8833/E8
Bidding Type Tender
Location
City Nasirabad
State Rajasthan
Key Dates
Publish Date 04 Oct 2019
Submission Date 01 Nov 2019
Open Date 04 Nov 2019
Finance
Tender Value 13.50 Lakhs
Tender Fee 500
EMD 27000
Exemption Not Available
Document List
General_Pages_8833.pdf
27985C32-7919-4C90-9AF5-F715C80E6816.html
BOQ_322644.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 04, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 01, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 04, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

General_Pages_8833.pdf

html

27985C32-7919-4C90-9AF5-F715C80E6816.html

xls

BOQ_322644.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders