Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #22036954

Provision Of 10 Kva Silent Generator Set For Assembly Hall At Rms Chail , 48V Dc Smps ( 150Amps ) And 10Kva Ups For Network Spectrun ( Nfs ) Equipment At Ascon Node Shimla Of 571 Sub Gp And Special Repair For Replacement Of Unsv Earthing Of Switch Gea

Issued by Statutory Bodies & Commissions/Committees · JUTOGH, Himachal Pradesh
Tender Value
25.60 Lakhs
Estimated cost
Bid Submission
17 Oct 2019
0 days left
EMD
51200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
JUTOGH → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

provision Of 10 Kva Silent Generator Set For Assembly Hall At Rms Chail , 48V Dc Smps ( 150Amps ) And 10Kva Ups For Network Spectrun ( Nfs ) Equipment At Ascon Node Shimla Of 571 Sub Gp And Special Repair For Replacement Of Unsv Earthing Of Switch Gear Equipme

BOQ

Name of Work: PROVN OF 10 KVA SILENT GENERATOR SET FOR ASSEMBLY HALL AT RMS CHAIL,48V DC SMPS (150AMPS) AND 10KVA UPS FOR NETWORK SPECTRUN (NFS) EQUIPMENT AT ASCON NODE SHIMLA OF 571 SUB GP AND SPECIAL REPAIR FOR REPLACEMENT OF UNSV EARTHING OF SWITCH GEAR EQUIPMENT AT MAIN RECEIVING STATION AND CONNECTED PANELS AT JUTOGH CANTT UNDER GE JUTOGH.
S. No.Item DescriptionItem Code / MakeQuantityUnits
11Supplying, installation, testing and commissioning of Eco Friendly, silent, diesel driven Generating set of 10 KVA/8 KW at 0.8 power factor or nearest higher size, 415/440 volts AC, 3 phase, 50 Hz, 4 wire, 0.8 power factor, directly coupled alternator and engine, water cooled common base platform with floor mounted fuel tank incl excavation, PCC in foundation, anti vibration pads/dampers and standard control panel as per manufacturer's instructions complete all as specified comprising by providing the following accessories:-1Job
21.01Engine/Prime Mover:- Eco friendly for emission and noise (CPCB NORMS COMPLIANCE) Diesel engine confirming to BS standard developing suitable BHP @ 1500 RPM, turbocharged after cooling complete under NTP condition, with a provision for 10% over load for one hour on 12 hours running with the following:-
31.02Fly wheel with starter ring for generating set.
41.03Dry type air filter.
51.04Lubricant oil cooler assembly with accessories.
61.05Exhaust Air manifold.
71.06Exhaust silencer
81.07Alternator:- Brushless type, suitable for direct coupling to engine, self excited, self regulated with fast response thyristor type electronic automatic voltage regulator for output voltage within desired limits (± 1%) Dynamically balanced 415/440 volts, AC, 3 Phase, 50 Hz, 4Wire, 0.8 PF lagging 10 KVA or nearest size on higher side, 1500 RPM, star connected (4 wire ), screen protected drip proof enclosures, air cooled with radial fan mounted on rotor, with insulation class F/H all as per BS-2613, IS 4722 with following accessories:-
91.08MS frame suitable for mounting of engine and alternator.
101.09Fuel tank of suitable capacity for 8 to 12 hrs continuous running complete with fuel gauge, inlet/outlet connections, drain plug etc. to be mounted on suitable angle iron frame or grouted on wall as per manufacturer’s instructions.
111.112 Volts DC battery of suitable capacity as per manufacturer's instructions SMF type with copper leads and terminal lugs of suitable size.
121.11Set of AVM pads fitted on Base Frame.
131.12Hand rotary type fuel pump connected with heavy duty pipe upto the tank.
141.13Adequate ventilation to meet air requirement for combustion and heat removal with a provn of a blower.
151.14Provn of light inside the canopy.
161.15ACCOUSTIC ENCLOSURE suitable for DG set shall be as Under:-
171.16Fabricated out of CRCA sheet of suitable thickness. Polyester based powder coated internally and externally with lockable type door handle. All nuts, bolts and hardware shall be zinc coated
181.17Sheet metal components shall be hot dip seven tanks pretreated.
191.18Doors with EPDM gaskets.
201.19Soundproofing with high quality rock wool/mineral wool confirming to IS 8183, of 50 mm thickness and density 96kg/cubic meter coverd with fiber glass cloth and perforated powder coated sheet, specially designed attenuators (sound controller) at air entry and exit of the container. Noise level shall not exceed 75 dB A at 1 m distance as per CPCB Norms.
211.2Emergency stop push button outside the container.
221.21AUTOMATIC MAINS FAILURE PANEL :- AMF panel for 10 KVA/8KW DG Set fabricated out of sheet steel factory made suitable for floor mounting hinged from panel for easy accessibility with suitable rated bus bar internal wiring and with provision for connecting incoming/outgoing leads with the following accessories :-
231.22HRC fuse of proper rating for both incoming and suitable capacity MCCB for outgoing with setting range 70 to 100 %
241.23Auxiliary contactors of suitable capacity with timer (on delay)
251.24Voltmeter digital with selector switch
261.25Ammeter digital with selector switch
271.26Frequency meter digital with selector switch
281.27Power factor meter digital type
291.28KWH meter electronic digital type
301.29Two sets of indicator lamp 6 Nos LED Type for main and DG indication
311.3Master switch for auto/manual/test/off
321.31One set of lamps for indicating \"load on set\" \"load on mains\" set fails to start\" low oil pressure\" high cylinder tamp\" \" battery low\"
331.32Alarm/Hooter
341.33Battery charger connected to main supply to charge battery comprising by providing the following :-
351.34DC ammeter & voltmeter digital type
361.35Charge rate selection for tricle or high charge
371.36Indicator lamp for battery
381.37Set for easily accessible control fuses
391.38Set for relays to auto-start the engine on main failure and low voltage.
401.39Emergency triping device
411.4Foundation:- PCC foundation as per manufacturer’s design/instructions Gen Set. for
421.41MAKES :-
431.42Engine: Mahindra & Mahindra model No 2185 GM C2 or equivalent of Sudhir / Kirloskar Green/ Cummins
441.43ALTERNATOR:- Kirloskar Green / Crompton /Stamford/Jyoti/Cummins
451.44ACOUSTIC ENCLOSURE :- KIRLOSKER GREEN/Cummins or equivalent of Greaves cotton or Cummins or Rustonor, as per manufacturer’s recommendations.
461.45Notes :- Entire DG SET shall be procured from authorized original equipment manufacturer of M/s Kirlosker / Cummins /Mahindra & Mahindra
471.46The components i.e. engine, alternator, panel etc. of DG set shall be of one manufacturer only
481.47The components of the DG set shall not be more than six months old at the time of procurement.
492Supply and laying XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts grade of size 25 Sq mm , 4core cross sectional area, laid in trenches or ducts or under road or fixed on wall/pole incl connecting/jointing with lugs and testing all as specified and directed .200Rm
503All as per Srl item No 2.00 above but 16 Sqmm 4 Core.100Rm
514M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench , under and over cable complete all as specified and as directed.\nNote : Punned thickness of sand shall be measured6.21Cum
525M&L for old bricks slightly over burnt (kiln burnt) sub class 'B' bricks, best quality, locally available , laid flat, dry, laid in trenches along the length of cable transversely with width equal to length of brick for cable protection complete all as specified and directed.480Each
536Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm dia, conforming to IS, of approved colour complete with fittings for cable protection, laid in trenches/ fixed to wall/pole complete all as specified and directed. Make: Dura line /Finolex/Tele Rex65Rm
547All as per Srl item No 06.00 above but 50mm dia.30Rm
558S&F to walls/poles or laying in ground, under plinth/crossing walls etc GI pipe, light grade incl sealing ends with compound and teak wood bushes for ends, of size 50 mm dia complete all as specified and directed.12Rm
569Supply ,Install Testing & Commissioning of self supporting outdoor type totally enclosed LT panel Board CPRI approved of size not less than 1.2 x1.0 x 0.6m compartmentalised design, dust and varmin proof, suitable for 440 Volt, 3 phase, 4 wire system made out of 3.0mm thick CRCA sheet and built upon rigid frame work having front and rear hinged doors with neoprene rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Chromium plated and nuts, bolts ;and washers etc. The panel shall be painted with two coats of red oxide primer and final finish of synthetic enamelled grey paint and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification, including incoming/outgoing cable holes at the bottom. The Panel shall be embedded with 50 x 5 mm MS Angle Iron frame and 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 (using 40mm graded aggregate) complete all as specified and directed by Engr in charge and comprising the following.1Each
579.01Copper bus bar (40 x 10 mm) - 04 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.
589.02ON Load changeover switch 63 Amps 4 pole 415 volt C-line type duly connected to bus bar -01 No.
599.03MCCB 63 Amps ,415 volt ,25 KA breaking capacity 4 pole with thermal magnetic release duly connected to bus bar as in coming -01 No.
609.04Voltmeter 0-500 Volt Digital with selector switch - 01 Nos
619.05Ammeter 0 to 200 Amps Digital with CTs and selector switch - 02 Nos (Main and Gen set supply)
629.06LED indicating lamps with holder for main supply indication RYB-03 set (03 Nos) .
639.07Instrument fuse holder, fused 4 amps - 03 Nos
649.08OUTGOING
659.09MCCB for 16 to 100 amps ,3 pole, 415 volt , 25 kA breaking capacity duly connected to bus bar as out going -02 Nos
669.1Note: All Internal connection of MCCB from bus bar made by using suitable size copper bar of rated capacity.
6710S&F VTPN prewired distribution board TPN-DPX 125 MCCB incl one No MCCB 125 Amps as incomer and suitable SPN/TP MCBs as outgoing double door type sheet metal enclosure 415V with 200 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable for 4 way complete all as specified and as directed. Make: Legrand IP-54-IK-09 Cat No. 607770 or equivalent of ABB/Seimens/Hager\nNote : Rates of MCCB and MCB SPN/SP/TP shall deemed to be included in the quoted rate.1Each
6811S & F in repairs copper strip of size 32 x 6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified and directed.180Rm
6912M&L for concealed point wiring in PVC conduit with PVC insulated and unsheathed, single core cable of size 1.5 sqmm stranded copper conductor, FRLS, 1100 Volt grade, drawn into existing PVC rigid conduit of any dia and make with and incl 1.5 Sqmm unsheathed green colour stranded copper conductor cable, FRLS, for continuous earth wire terminated in M.S. sunken terminal boxes 1.20mm thick of suitable size covered with 2.60 mm thick plastic laminated sheet (hylam brand) white laminated sheet cover of suitable size for mounting switches/sockets/ regulators etc complete all as specified & directed, for the following :-
7012.01One light/fan/bell point controlled by one, one way switch on independent board.20Per Point
7112.02One socket outlet, 3/5 pin, 5 amp on same board with other switches with 2.5 Sqmm main and earth wire.5Per Point
7212.03One socket outlet, 3/5 pin, 5 amp on independent board with 2.5 Sqmm cable as main and earth wire15Per Point
7312.04One socket outlet 3/5 pin, 15 Amps with FRLS cable 4.0 Sqmm stranded copper conductor as main and earth wire on independent board.15Per Point
7413S&F bell push, piano, flush type, 5 Amps, 230 volts, SP, one way complete all as specified and directed.40Each
7514S&F socket outlet multipurpouse, suitable for 5 pin, 6 Amp, 230 volts, flush type complete all as specified and directed.20Each
7615S&F Sheet metal enclosure for MCBs, double door, single pole and neutral, 230 volts,12way with 200 Amps rated bus bar complete all as specified and directed \nMake-Legrand Cat Part No. 607711or equivalent of ABB/Seimens/Hager2Each
7716S&F MCB, Single Pole and neutral, of capacity 06 to 40 Amps, 415 volts, complete all as specified and directed.\nMake-Legrand /Seimens/ABB/Hager.8Each
7817S&F MCB, SP, of capacity 6 to 40 Amps, 415 volts, complete all as specified and directed \nMake-Legrand /Hager/ABB/Seimens20Each
7918S&F switch & socket combination 15 Amps, flush type, 230 Volts , AC complete all as specified and directed. Make:- Havells Cat part No AHETOFW204 or equivalent of Anchor/ Indoasian (ISI) Marked.15Each
8019M&L for submain wiring with two single core cable of size 6.0 sqmm PVC insulated FRLS stranded copper conductor and one single core green PVC insulated 6.0 sqmm FRLS stranded copper conductor earth continuity cable drawn through by providing non metallic PVC rigid conduit conduit of 25 mm dia incl all accessories & fixing arrangement complete all as directed.\nNote : 2 runs of main cable, one run of earth cable and conduit will be measured as one unit ie. 1 RM60Rm
8120Taking down unservicable earthing materials of any type and description14Each
8221M & L for earthing complete with galvanised steel earth plate 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised Steel earth wire 4mm as earthing lead by means of bolts, nuts, cheek nut and washers of galvanised iron or steel besides at all joints as shown in Electrical Plate No-3 of SSR Part I and incl excavation and earth work in any type of soil, GI pipe 15 mm dia, light grade protection pipe, charcoal filling, common salt ,PCC 1:3:6 type CI using 20 mm graded stone aggregate in chamber, MS angle iron frame 40x40x6mm and RCC cover 40mm thick (1:2:4) type B-1 using 20mm dia graded stone aggregate reinforced with 6mm dia round bars @ 75 mm c/c both ways with MS handle 12mm dia, CI funnel and wire mesh, 20mm bore med grade pipe for watering and connected to earth Test point incl testing complete all as specified and directed1Each
8322All as per Srl Item No. 21.00 but copper earth plate of size 60cmx60cmx6mm and copper strip of size 32x6 mm.14Each
8423All as per Srl Item No. 21.00 but copper earth plate of size 60cmx60cmx3.15mm and copper strip of size 20x3 mm.6Each
8524Supply, installation, testing and commissioning of SMPS 48 Volts DC with 150A capacity and 1 hour back up at mains failure, complete with AC input voltage 90V to 300V, single phase, input frequency 50Hz + 2 Hz, Output 48V DC nominal, Auto Foat: 52.8V DC (Float voltage), Auto Charge: 57.0V DC (Boost Votage), load voltage toerance 44.4V (Under Voltage) and 60V DC (Over voltage), output current Limit (150amps), Protection: DC Output high voltage overload/ short Circuit input surge protection with alarm facility complete with following:- Make: For SMPS:- APC (schneider)/ Siemens/ Partner/ Aplab/ AE/ Statcon Electronics India Ltd./ Vertiv/ Altech/ Delta.\nMake For VRLA BATTERY:- Exide/ Amron/ Tata/ Amco.\nNote:- Cost of VRLA Battery of required capacity shall be included in quoted rates.1Each Job
8624.01First stage conversion: Power factor correction alongwith HF filter and input AC Voltage rectification and conversion in high voltage DC.
8724.02Second stage conversion: Rectified high voltage DC is stored in capacitors. High voltage DC is then converted into a very high frequency AC (20 KHz and higher). Conversion of high voltage DC to high frequency AC is achived by means of very powerful and ultra fast semiconductor switching devices. High frequency AC is stepped down to the required level by means of small frequency transformer. Stepped down AC is rectified by ultra high speed diodes to DC of desired voltage and filtered by means of high frequency filters and pure DC voltage is stored in capacitors.
8824.03Protection of DC Output high voltage over load/ short circuit input surge protection, soft start circuit input surge protection, soft start facility, over temperature16 indications (LED) mains ON, Float, Boost 17 Alarms (Visual) DC output over voltage, under voltage DC output, over load, module fail function.
8925Supply, Installation, testing and commissioning of on line uninterrupted power supply system three phase input and output capacity not less than 10KVA at full load condition i.e. 14.8 Amps at each phase (RYB)with one hour irrespective of input voltage current incl neutral failure system and neutral genration type complete with battery for 1hours min backup with following :- Make:- For UPS:- APC (schneider)/ Siemens/ Partner/ Aplab/ AE/ V-Guard/ Unitech Power Solution/ Vertiv/ Delta/ Microtek\nMake For VRLA BATTERY:- Exide/ Amron/ Tata/ Amco.\nNote: - (i) Cost of VRLA Battery of required capacity shall be included in quoted rates.\n(ii) Cost of cable tray, conduit of suitable size shall be included in quoted rate.1Each
9025.01Double conversion on line, continuous voltage & frequency regulation, high power density, wide input voltage range, user replaceable batteries, built-In-automatic & manual by pass, fast recharge time, cold/ soft start, IGBT ( Insulated- Gate Bipolar Transistor) based with isolation transformer, lightening and surge protection in built, sine wave output, emergency power off facility, alarms and indicators, power cut software.
9125.02Note for Item No 25 & 26: - All incoming and outgoing copper conductor cable as per required size, foundation as per manufacturer guidelines, thimble, lugs and making good to the disturbed surface are incl in the quoted rates.
9226Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in Soft/ loose soil for foundation of poles, cables, stay etc and getting out complete all as specified and directed.16Cum
9327All as per Srl Item No 26.00 but in hard/ dense soil.4Cum
9428Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.7.99Cum
9529Returning filling in trenches incl spreading, leveling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and directed..12.01Cum
9630M&L for PCC 1:4:8, type D2 ( using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.0.4Cum
9731M&L for RCC 1:2:4,Type B1,(Nominal mix) (using 20mm graded crushed stone aggregate) as in foundation, including raft footing,etc complete all as specified and directed.2.05Cum
9832M & L for brick work, with sub class 'B', bricks kiln well burnt, old size bricks, straight or curved on plan exc 6 m in mean radius, built in cement mortor (1: 6) complete all as specified and as directed .2.73Cum
9933M & L for hard core of gauge not exc 63mm of broken stone / boulders, deposited , spread, levelled, watered and well rammed to the true surface in layers n exc 15cm thickness complete all as specified and directed.0.68Cum
10034M&L for 75mm thick PCC 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in sub base under floors, finished even and fair to receive top finish complete all as specified and directed.9Sqm
10135M&L for 100mm thick plain cement concrete 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in flooring, finished even and smooth without using extra cement complete all as specified and directed.9Sqm
10236M&L for PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in bed blocks, coping, plinth courses water trough etc using necessary form work with slightly rounded or chamfered angles and finishing the surfaces smooth complete all as specified & directed.0.15Cum
10337All as per Srl Item No 36.00 but type C-2 1:3:6 (using 20mm graded aggregate).0.65Cum
10438M&L for RCC 1:1.5:3,Type A1,(Nominal mix) (using 20mm graded crushed stone aggregate) as in columns,pillars etc complete all as specified and directed.0.66Cum
10539M&L for use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or batter, rough finished, complete all as specified and directed.19.75Sqm
10640M&L for use and waste of form work to sides of pillars, posts, struts, columns etc on square, rectangular, rough finished surface complete all as specified and directed.11.6Sqm
10741M & L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or stone surfaces, finishing surface even or smooth w/o using extra cement in patches at any height complete all as specified and directed9.72Sqm
10842M & L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finishing surface even and smooth w/o using extra cement in patches at any height complete all as specified and directed10.54Sqm
10943M & L for preparation of newly plastered or unplastered surfaces of walls etc and applying two coats of oil bound distemper over one coat of chalk whitening primer complete all as specified and directed. Note : Tint and shade as approved by GE.9.72Sqm
11044M & L for preperation of newly plastered wall surfaces and applying two coats of cement based paint over one coat of cement alkali primer complete all as specified . Note:- Colour and shade will be approved by GE.10.54Sqm
11145S&F structural steel roof trusses (framed), trussed purlins, posts, crane gantries, rails and fastening and heavy bracket framing (Beam, tee , anfle, channel or flat sections) incl distance places cleats etc. complete all as specified and directed.181.63Kg
11246S & F TMT bars 10mm dia and over, cut to length, bent to shape required incl cranking bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire not less than 0.9 mm dia or securing with clips complete all as specified and directed.159.33Kg
11347All as per Srl item No 46.00 above but 5mm dia and over upto and incl 10mm dia as in stirups, spacers and binders.67.54Kg
11448S&F mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barrel iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 grade 165 complete all as specified and directed.280Kg
11549S & F mild steel plate work ( plain or chequered) channels, square cut or notched (ordinery and counter sunk) forming holes, without any attachment Fe 410W (Gde E250) quality A complete all as specified and directed.4.4Kg
11650S&F 1.00mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.2.52Sqm
11751M&L for welded steel wire fabric weight n exc 4 kg per sqm fixed to steel with welding or wood members complete all as specified and directed.79Kg
11852M&L for preparation of new or previously untreated surfaces of iron or steel of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed36.42Sqm
11953S & F pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick of approved colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping hard steel screws with washers complete as specified and directed. Note: Colour and size will approved by GE19.36Sqm
12054S&F 100 mm long medium weight mild steel butt hinges complete all as specified and directed.6Each
12155S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed.1Each
12256S&F for bands, straps, supports or stays for rainwater, ventilating pipes, incl bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.2Kg

AI Tender Summary

OUR REF NO 22036954
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25.60 Lakhs
LAST DATE 17-10-2019
Authority
Authority Name Military Engineer Services
Work Description provision Of 10 Kva Silent Generator Set For Assembly Hall At Rms Chail , 48V Dc Smps ( 150Amps ) And 10Kva Ups For Network Spectrun ( Nfs ) Equipment At Ascon Node Shimla Of 571 Sub Gp And Special Repair For Replacement Of Unsv Earthing Of Switch Gear Equipme
Basic Detail
Tender No GE/JUT-03/2019-20
Bidding Type Tender
Location
City JUTOGH
State Himachal Pradesh
Key Dates
Publish Date 03 Oct 2019
Submission Date 17 Oct 2019
Open Date 19 Oct 2019
Finance
Tender Value 25.60 Lakhs
Tender Fee 500
EMD 51200
Exemption Not Available
Document List
Tendernotice_1.pdf
tenderdocument1.pdf
BOQ_322258.xls
tenderdocument2.pdf
AC9F3FF1-9F49-431F-9497-86FB9C7A897F.html
tenderdocument3.pdf
NIT.pdf
tenderdocuments.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 03, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 17, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 19, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

tenderdocument1.pdf

xls

BOQ_322258.xls

pdf

tenderdocument2.pdf

html

AC9F3FF1-9F49-431F-9497-86FB9C7A897F.html

pdf

tenderdocument3.pdf

pdf

NIT.pdf

pdf

tenderdocuments.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders